Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MgH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

In situ observation on hydrogenation of Mg-Ni films using environmental transmission electron microscope with aberration correction

In situ transmission electron microscopy (TEM) was performed to observe the hydrogenation of Mg-Ni films in a hydrogen atmosphere of 80–100 Pa. An aberration-corrected environmental TEM with a differential pumping system allows us to reveal the Angstrom-scale structure of the films in the initial stage of hydrogenation: first, nucleation and growth of Mg{sub 2}NiH{sub 4} crystals with a lattice spacing of 0.22 nm in an Mg-rich amorphous matrix of the film occurs within 20 s after the start of the high-resolution observation, then crystallization of MgH{sub 2} with a smaller spacing of 0.15 nm happens after approximately 1 min. Our in situ TEM method is also applicable to the analysis of other hydrogen-related materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compensation and hydrogen passivation of magnesium acceptors in β-Ga 2 O 3

Magnesium-doped gallium oxide may be utilized as a semi-insulating material for future generations of power devices. Spectroscopy and hybrid functional calculations were used to investigate defect levels in Czochralski-grown β-Ga 2 O 3 . Substitutional Mg dopants act as deep acceptors, while substitutional Ir impurities are deep donors. Hydrogen-annealed Ga 2 O 3 :Mg shows an IR peak at 3492 cm –1 , assigned to an O-H bond-stretching mode of a neutral MgH complex. As a result, despite compensation by Ir and Si and hydrogen passivation, high concentrations of Mg (10 19 cm –3 ) can push the Fermi level to mid-gap or lower.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical Zeeman spectroscopy of the (0, 0) A {sup 2}Π-X {sup 2}Σ{sup +} band system of magnesium hydride

The Zeeman effect on lines in the (0, 0) A {sup 2}Π-X {sup 2}Σ{sup +} band system of a cold molecular beam sample of magnesium hydride, MgH, has been recorded at high resolution (FWHM ≅60 MHz) and analyzed. The lines associated with the lowest rotational levels are detected for the first time. The field-free spectrum was analyzed to produce spectroscopic parameters for the A {sup 2}Π (v = 0) state. The experimentally observed magnetic tuning of the low-rotational spectral features at field strengths comparable to those found in sunspots is accurately modeled by assuming that the electronic spin and orbital magnetic g-factors, g{sub S} and g{sub L} , of the A {sup 2}Π and X {sup 2}Σ{sup +} states are 2.002 and 1.000, respectively, and g {sub l} is –0.0023 for the X {sup 2}Σ{sup +}.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an ADC radiation tolerance characterization system for the upgrade of the ATLAS LAr calorimeter

ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydride-based thermal energy storage

Abstract The potential and research surrounding metal hydride (MH) based thermal energy storage is discussed, focusing on next generation thermo-chemical energy storage (TCES) for concentrated solar power. The site availability model to represent the reaction mechanisms of both the forward and backward MH reaction is presented, where this model is extrapolated to a small pilot scale reactor, detailing how a TCES could function/operate in a real-world setting using a conventional shell & tube reactor approach. Further, the important parameter of effective thermal conductivity is explored using an innovative multi-scale model, to providing extensive and relevant experimental data useful for reactor and system design. Promising high temperature MH material configurations may be tuned by either destabilisation, such as using additions to Ca and Sr based hydrides, or by stabilisation, such as fluorine addition to NaH, MgH 2 , or NaMgH 3 . This versatile thermodynamic tuning is discussed, including the challenges in accurately measuring the material characteristics at elevated temperatures (500 –700 °C). Attention to scale up is explored, including generic design and prototype considerations, and an example of a novel pilot-scale pillow-plate reactor currently in development; where materials used are discussed, overall tank design scope and system integration.

25 ENERGY STORAGE↗

Generation and Validation of the iKp1289 Metabolic Model for Klebsiella pneumoniae KPPR1

Klebsiella pneumoniae has a reputation for causing a wide range of infectious conditions, with numerous highly virulent and antibiotic-resistant strains. Metabolic models have the potential to provide insights into the growth behavior, nutrient requirements, essential genes, and candidate drug targets in these strains. Here we develop a metabolic model for KPPR1, a highly virulent strain of K. pneumoniae. We apply a combination of Biolog phenotype data and fitness data to validate and refine our KPPR1 model. The final model displays a predictive accuracy of 75% in identifying potential carbon and nitrogen sources for K. pneumoniae and of 99% in predicting nonessential genes in rich media. We demonstrate how this model is useful in studying the differences in the metabolic capabilities of the low-virulence MGH 78578 strain and the highly virulent KPPR1 strain. For example, we demonstrate that these strains differ in carbohydrate metabolism, including the ability to metabolize dulcitol as a primary carbon source. Our model makes numerous other predictions for follow-up verification and analysis.

bacteria↗

Divergent synthesis routes and superconductivity of ternary hydride MgSiH 6 at high pressure

We predict a new ternary hydride MgSiH6 under high pressures, which is a metal with an ionic feature and takes on a simple cubic structure with space group Pm-3 above 250 GPa. Our first-principles calculations show that the cubic MgSiH 6 is a potential high-temperature superconductor with a superconducting transition temperature T c of ~ 63 K at 250 GPa. Further analysis suggests that phonon softening along mainly Γ-X and Γ-M directions induced by Fermi surface nesting plays a crucial role in the high-temperature superconductivity. Herein we propose the “triangle straight-line method” which provides a clear guide to determine the specific A + B → D type formation routes for ternary hydrides of the Mg-Si-H system and it effectively reveals two divergent paths to obtain MgSiH6 under high pressures: MgH 2 + SiH 4 → MgSiH 6 and MgSi + 3H 2 → MgSiH 6 . This method might be applicable to all ternary compounds, which will be very significant for further experimental synthesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistically averaged molecular dynamics simulations of hydrogen diffusion in magnesium and magnesium hydrides

Magnesium has a different crystal structure from its dihydride with hydrogenation leading to a phase transition from the hexagonal closely packed Mg into a tetragonal α-MgH 2 rutile type structure. Such materials exhibit complex hydrogen uptake and release kinetics because hydrogen diffusivities significantly change when the crystal structure changes. To provide a foundational understanding of (de)hydrogenation kinetics that is applicable to all stages of the reaction, we performed statistically averaged molecular dynamics simulations to derive hydrogen diffusivities as a function of temperature and hydrogen content for both magnesium and magnesium hydride. Furthermore, our studies confirm that hydrogen diffusivities in magnesium hydride are much lower than in magnesium, in agreement with experimental data. Additionally, we observe that in either magnesium or magnesium hydride, higher hydrogen compositions result in reduced diffusivities. The latter was not revealed by prior experiments, which were conducted at fixed hydrogen composition. Finally, we discover a non-Arrhenius behavior in magnesium hydride. The physical origin of this behavior is also discussed.

36 MATERIALS SCIENCE↗

Hydrogen passivation of calcium and magnesium doped β-Ga 2 O 3

Calcium and magnesium doped beta-phase gallium oxide (β-Ga 2 O 3 ) single crystals were Czochralski grown in an iridium crucible and subsequently annealed in hydrogen at ~800° C. IR spectroscopy was used to investigate the roles of Mg and Ca dopants as well as H and Ir impurities. An IR peak at 3492 cm -1 was previously assigned to an O-H bond-stretching mode of a MgH complex in hydrogen-annealed Ga 2 O 3 :Mg and an IR peak at 3541 cm -1 is tentatively assigned to a similar mode in a CaH complex for H annealed Ga 2 O 3 :Ca. An IR peak at 5148 cm -1 is attributed to the presence of Ir 4+ when magnesium is present. Excitation with several different wavelengths used to confirm the position of the Ir level within the band gap. Our results suggest that isolated substitutional Ca dopants are less effective as deep acceptors than Mg. Polarization dependence of the iridium IR spectra is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-441: Comparison of Dose Distributions for Spot-Scanned Pencil-Beam and Scattered-Beam Proton Treatments of Ocular Tumors

Purpose: To study the cross-field and depth dose profiles of spot-scanned pencil beam configurations for the treatment of ocular tumors and to compare their performance to a simulated scattered beam. Methods: Dose distributions in a cubic water phantom were compared for beams that passed through a final 24mm diameter aperture to deposit maximum dose at 2.4cm depth. The pencil-beam spots formed a hexagonally-packed ring with a center-to-center spacing of 4mm. The protons exited the nozzle with energy 95.5MeV, traversed a 4.5cm water-equivalent range shifter, and travelled either 42.5cm or 100cm to the phantom surface. The aperture-to-phantom distance (APD) was 5.7cm to allow room for eye-tracking hardware. A configuration with APD=0 was also tested. The scattered beam was generated with energy 159MeV, passed through 127mm of Lexan, exited the final aperture, and travelled 5.7cm to the phantom surface. This latter configuration is comparable to the MGH single scattered beamline. All beams were modelled with TOPAS1.0-beta6 compiled with GEANT4.9.6p2. Results: The modeled scattered beam produced a distal fall-off along the central axis of zd90%-zd10%=3.6mm. For the pencil beam, the zd90%-zd10% was 1.6mm in all configurations. The scattered beam's cross-field penumbra at depth of maximum dose was r90%- r10%=1.9mm. For the spot-scanned configuration with the range-shifter-tophantom distance (RsPD) of 100cm, similar cross-field profiles were achieved with r90%-r10%=2.0mm. At shorter RsPD of 42.5cm, the crossfield penumbras were 5.6mm and 7.7mm for APD=0cm and APD=5.7cm, respectively. Conclusion: For proton treatments employing a range shifter, the cross-field and central axis dose profiles depend on the quality of the original beam, the size of the range shifter, the distance from the range shifter exit to the patient, and the distance from the final aperture to the patient. A spot-scanned pencil beam configuration can achieve cross-field penumbras equal to a scattered beam and superior distal gradients.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-07: The Radiological Physics Center (RPC): 45 Years of Improving Radiotherapy Dosimetry

Purpose: The RPC, established in 1968 has contributed to the development, conduct, and QA of NCI funded multi-institutional cooperative group clinical trials and institutions, primarily in the USA/Canada and 242 other countries, participating in trials. Methods: The RPC QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program included: 1) remote TLD/OSLD audit of machine output, 2) on-site dosimetry review visits, 3) credentialing for advanced technologies, and 4) review of patient treatment records. The RPC presented and published their findings to the radiation oncology community. Results: The number of institutions monitored by the RPC increased from around 1200 in the late 90s, to ∼2000 in 2013. There were over 4000 megavoltage therapy machines and ∼28,000 therapy beams in the 1991 institutions monitored by the RPC by the end of 2013. Within the 14,000 photon, electron and proton beam outputs remotely monitored with TLD/OSLD annually, between 10-20% of the institutions have one or more beams outside the RPC 5% criterion. Dosimetry site visits to photon and proton centers continue to result in 2-4 recommendations affecting key dosimetry parameters that impact patient treatment times. One in four patient treatment records reviewed by the RPC have their dose data corrected by >5% before trial groups use them for outcomes analysis. Twelve of fourteen clinically active proton centers are approved to participate in NCI funded clinical trials. The RPC published 222 peer reviewed articles since 1972. Conclusion: Findings from the RPC suggest that human errors continue to play a role in radiotherapy discrepancies and without the RPC independent QA program, the number of undetected errors and time elapsed before their discovery would have been greater. Work supported by MGH C06 CA059267 and grants CA10953, CA081647 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-214: Re-Thinking the Useful Clinical Beam Energy in Proton Therapy: An Opportunity for Cost Reduction

Purpose: We conducted a retrospective study of the useful clinical proton beam energy based on the beam range data of patients treated over the last 10 years at Massachusetts General Hospital Proton Therapy Center. Methods: Treatment field information were collected for all patients treated over the last 10 years (2005–2015) in the two gantry treatment rooms at MGH. The beam ranges for these fields were retrieved and categorized per treatment site. The 10 prostate patients that required the highest beam range (lateral fields) were selected. For these patients, anterior oblique beams (30–40 degrees) were simulated in a planning system to obtain the required beam ranges including the margins for potential range uncertainties. Results: There were a total of 4033 patients, treated with combined total of 23603 fields. All treatment indications were considered with the exception of ocular tumors generally treated in a fixed beam room. For all non-prostate treatments (21811 fields), only 5 fields for 4 patients (1-pancreas, 1-lumbar chordoma, 2-spine mets) required beam range greater than 25 cm. There were 446 prostate patients (1792 fields), with the required beam range from 22.3 to 29.0 cm; 386 of them had at least one of their lateral beam range greater than 25 cm. For the 10 prostate patients with highest lateral beam ranges (26 to 29 cm), their treatment with anterior oblique beams would drop the beam ranges below 25 cm (17.3 to 18.5 cm). Conclusion: if prostate patients are treated with anterior fields only, the useful maximum beam range is reduced to 25 cm. Thus a proton therapy system with maximum beam energy of 196 MeV is sufficient to treat all tumors sites with very rare exceptions (<0.1%). Designing such PT system would reduce the cost of proton therapy for hospitals and patients and increase the accessibility to the treatment.

60 APPLIED LIFE SCIENCES↗

Hydrogenation of the nanopowders that form in a carbon-helium plasma stream during the introduction of Ni and Mg

Composite nanoparticles consisting of magnesium, nickel, and carbon atoms are studied both theoretically and experimentally. The calculations performed in terms of the density functional theory show that the jump frequency of hydrogen atoms in nickel-containing magnesium hydride increases substantially near impurity nickel atoms; as a result, the rate of hydrogen absorption by magnesium also increases. Nickel on the magnesium surface is shown to be absorbed via an island growth mechanism. Composite Mg-C, Ni-C, and Mg-Ni-C powders are produced by plasmachemical synthesis in a carbon-helium plasma stream. Hydrogen is introduced into a chamber during synthesis. It is found by X-ray photoelectron spectroscopy and thermogravimetric analysis that, among these three composites, only Mg-Ni-C contains magnesium fixed in the MgH{sub 2} compound. The process of such 'ultrarapid' hydrogenation of magnesium, which occurs in the time of formation of composite nanoparticles, can be explained by the catalytic action of nickel, which is enhanced by a high temperature. Scanning electron microscopy micrographs demonstrate the dynamics of the dehydrogenation of Mg-Ni-C composite nanoparticles in heating by an electron beam.

36 MATERIALS SCIENCE↗

Theoretical Studies of Hydrogen Storage Alloys

Theoretical calculations were carried out to search for lightweight alloys that can be used to reversibly store hydrogen in mobile applications, such as automobiles. Our primary focus was on magnesium based alloys. While MgH 2 is in many respects a promising hydrogen storage material, there are two serious problems which need to be solved in order to make it useful: (i) the binding energy of the hydrogen atoms in the hydride is too large, causing the release temperature to be too high, and (ii) the diffusion of hydrogen through the hydride is so slow that loading of hydrogen into the metal takes much too long. In the first year of the project, we found that the addition of ca. 15% of aluminum decreases the binding energy to the hydrogen to the target value of 0.25 eV which corresponds to release of 1 bar hydrogen gas at 100 degrees C. Also, the addition of ca. 15% of transition metal atoms, such as Ti or V, reduces the formation energy of interstitial H-atoms making the diffusion of H-atoms through the hydride more than ten orders of magnitude faster at room temperature. In the second year of the project, several calculations of alloys of magnesium with various other transition metals were carried out and systematic trends in stability, hydrogen binding energy and diffusivity established. Some calculations of ternary alloys and their hydrides were also carried out, for example of Mg 6 AlTiH 16 . It was found that the binding energy reduction due to the addition of aluminum and increased diffusivity due to the addition of a transition metal are both effective at the same time. This material would in principle work well for hydrogen storage but it is, unfortunately, unstable with respect to phase separation. A search was made for a ternary alloy of this type where both the alloy and the corresponding hydride are stable. Promising results were obtained by including Zn in the alloy.

08 HYDROGEN↗

Reversible Hydrogen Storage Materials – Structure, Chemistry, and Electronic Structure

To understand the processes involved in the uptake and release of hydrogen from candidate light-weight metal hydride storage systems, a combination of materials characterization techniques and first principle calculation methods have been employed. In addition to conventional microstructural characterization in the transmission electron microscope, which provides projected information about the through thickness microstructure, electron tomography methods were employed to determine the three-dimensional spatial distribution of catalyst species for select systems both before and after dehydrogenation. Catalyst species identification as well as compositional analysis of the storage material before and after hydrogen charging and discharging was performed using a combination of energy dispersive spectroscopy, EDS, and electron energy loss spectroscopy, EELS. The characterization effort was coupled with first-principles, electronic-structure and thermodynamic techniques to predict and assess meta-stable and stable phases, reaction pathways, and thermodynamic and kinetic barriers. Systems studied included: NaAlH 4 , CaH 2 /CaB 6 and Ca(BH 4 ) 2 , MgH 2 /MgB 2 , Ni-Catalyzed Magnesium Hydride, TiH 2 -Catalyzed Magnesium Hydride, LiBH 4 , Aluminum-based systems and Aluminum.

08 HYDROGEN↗

Healthcare Energy End-Use Monitoring

NREL partnered with two hospitals (MGH and SUNY UMU) to collect data on the energy used for multiple thermal and electrical end-use categories, including preheat, heating, and reheat; humidification; service water heating; cooling; fans; pumps; lighting; and select plug and process loads. Additional data from medical office buildings were provided for an analysis focused on plug loads. Facility managers, energy managers, and engineers in the healthcare sector will be able to use these results to more effectively prioritize and refine the scope of investments in new metering and energy audits.

30 DIRECT ENERGY CONVERSION↗

Production of Medically Important Radionuclides 52 Mn and 90 Nb

Over the final reporting period of this project, we at MGH finalized our effort on Project 2: Production and Characterization of 90 Nb which, as per our previous report led us to an interesting application of mass spectrometry in radiometal chemistry. Overall, our research has developed parameters and procedures for delivering high 90 Nb for preclinical and translational applications by initializing the cyclotron targetry and separation chemistry for delivering 90 Nb in a chemical form suitable for subsequent development of 90 Nb-based PET radiotracers, and most recently we have published on the mass spectrometry applications described in the present report. We have been working with MSKCC (PI Jason Lewis) on the 90 Nb methodology and have had input from UAB (PI Suzy Lapi). An in-person meeting was held during the upcoming funding period with 2 PIs who are co-organizing the Radiochemistry Symposium (Lapi and Vasdev) and Program Director Dr. Ethan Balkin, during the ACS National Meeting in March 2018, and 2 PIs (Lewis and Vasdev) co presented in at the World Federation of Nuclear Medicine and Biology at a symposium sponsored by the Australian Nuclear Sciences and Technology Organisation, where they are both collaborating, in Melbourne, Australia in April 2018. Future projects and collaborations are under discussion with the Lapi lab to focus on new applications of 76 Br chemistry, and a new collaboration has already resulted with the Lewis lab on 18 F radiochemistry that employ iodonium ylide based precursors developed in the Vasdev lab, for clinical production of [ 18 F]MFBG. It is noteworthy that the PI has now relocated to the University of Toronto and has 2 cyclotrons (IBA Cyclone and Scanditronix MC-17) that will also be used to explore new 11 C-radiochemistry including [ 11 C]CO.

07 ISOTOPE AND RADIATION SOURCES↗