Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical radioisotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of low intensity X-ray imaging devices (Lixiscope)

Radioisotopic sources were used to excite the LIXISCOPE in preliminary experimental attempts to evaluate the usefulness of this instrument for industrial and medical applications. The characteristics of the LIXISCOPE when excited by x-ray produced by conventional electrically powered x-ray generators were studied. The optimum x-ray spectrum was determined and the mode of operation of the generator, which yields satisfactory LIXISCOPE images of medical and industrial specimens was investigated.

Ferguson, G. A.↗

Sulfur-functionalized solid-phase materials for the selective separation of arsenic and selenium

Radioactive arsenic (As) isotopes are of growing interest for applications in nuclear medicine, national security, and environmental research. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have focused on aqueous harvesting of selenium-72,73 ( 72,73 Se) and their daughter isotopes, arsenic-72,73 ( 72,73 As), which are particularly valuable for medical applications and nuclear data studies, respectively. Both conventional isotope production and harvesting methods require chemical separations to purify radioactive As from parent and co-produced Se radioisotopes. While several solid-phase separation methods for As and Se exist, many depend on complex oxidation state control or highly acidic conditions. This study presents results for sulfur-based solid-phase materials selected to enable uptake at lower acidity and eliminate the need for intricate redox chemistry. Specifically, the performance of three covalently bound sulfur-based ligands were evaluated: (1) thiophenol-polystyrene, (2) propanethiol-silica, and (3) thiourea-silica. Uptake characteristics—including distribution coefficients (Dw), kinetics, and column separation behavior—were assessed using 75 Se and 73 As in hydrochloric (HCl) acid and nitric (HNO 3 ) solutions. The resins demonstrated high-yield (>95%) and high-purity As recovery across a range of HCl concentrations. Comparable results in HNO 3 were achieved when combined with anion exchange chromatography. Furthermore, the potential application of these materials for medical isotope generators was also investigated through ligand stability and repeated elution studies. Overall, sulfur leaching from the resins was negligible at the concentrations relevant for these separations but increased with higher acid concentrations.

Arsenic↗

Low-Temperature Electronic Components Being Developed

In many future NASA missions, such as deep space planetary exploration and the Next Generation Space Telescope, electrical components and systems must operate reliably and efficiently in extremely low temperature environments. Most modern electronic components cannot operate below moderately low operating temperatures (-40 to -55 C). The low-temperature electronics program at the NASA Lewis Research Center is focusing on the development and characterization of low-temperature components and the integration of the developed devices into demonstrable very low-temperature (-200 C) power systems such as dc-dc converters. Such low-temperature electronics will not only tolerate hostile environments but also will reduce system size and weight by eliminating radioisotope heating units, thereby reducing launch cost, improving reliability and lifetime, and increasing energy densities. Low-temperature electronic components will also have a great influence on terrestrial applications such as medical instrumentation, magnetic levitation transportation systems, and arctic and antarctic exploration. Lewis researchers are now performing extensive evaluations of commercially available as well as custom-made devices. These include various types of energy storage and signal capacitors, power switching devices, magnetic and superconducting materials, and primary lithium batteries, to name a few.

Patterson, Richard L.↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗

Measuring the metastatic potential of cancer cells

Cancer cells must secrete proteolytic enzymes to invade adjacent tissues and migrate to a new metastatic site. Urokinase (uPA) is a key enzyme related to metastasis in cancers of the lung, colon, gastric, uterine, breast, brain, and malignant melanoma. A NASA technology utilization project has combined fluorescence microscopy, image analysis, and flow cytometry, using fluorescent dyes, and urokinase-specific antibodies to measure uPA and abnormal DNA levels (related to cancer cell proliferation) inside the cancer cells. The project is focused on developing quantitative measurements to determine if a patient's tumor cells are actively metastasizing. If a significant number of tumor cells contain large amounts of uPA (esp. membrane-bound) then the post-surgical chemotherapy or radiotherapy can be targeted for metastatic cells that have already left the primary tumor. These analytical methods have been applied to a retrospective study of biopsy tissues from 150 node negative, stage 1 breast cancer patients. Cytopathology and image analysis has shown that uPA is present in high levels in many breast cancer cells, but not found in normal breast. Significant amounts of uPA also have been measured in glioma cell lines cultured from brain tumors. Commercial applications include new diagnostic tests for metastatic cells, in different cancers, which are being developed with a company that provides a medical testing service using flow cytometry for DNA analysis and hormone receptors on tumor cells from patient biopsies. This research also may provide the basis for developing a new 'magic bullet' treatment against metastasis using chemotherapeutic drugs or radioisotopes attached to urokinase-specific monoclonal antibodies that will only bind to metastatic cells.

Morrison, Dennis R.↗

Gamma Spectroscopy Detector Candidates and Radioisotope Identification Algorithms for Use in National Security Applications

In 2006, the United States Congress mandated for the Department of Homeland Security (DHS) to screen all cargo containers to protect against terrorist acts and ensure the safety and security of the nation. Containers are screened by gamma and neutron detectors to ensure threat material is not smuggled into the country. However, because commerce is radioactive, detecting the presence of radioactive materials is not sufficient in ensuring the safety and security of the nation. Radioactive materials must also be identified in real time, thus distinguishing threat sources (Uranium-235 and Plutonium-230) from non-threat sources (kitty litter, pot ash, medical isotopes). Screening cargo containers can be considered a two-step process (1) alerting to the presence of radioactive material when gamma counts exceed a threshold setting, and (2) once alerted, identifying the type of radioactive material, which is done by collecting a gamma spectra and analyzing it with an analysis tool/algorithm. For this reason, it is important to evaluate not only emerging technology in neutron and gamma detection, but also investigate new advances in algorithm development for radioisotope identification (RIID). New candidates in detection and on-board algorithm analysis might offer opportunities to make the scanning, detection, and identification process more efficient while still ensuring the health and safety of the public. This research will investigate emerging technology in radiation detection focused on gamma spectroscopy capabilities and RIID algorithms for DHS applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Development of radiopharmaceuticals for targeted alpha therapy: Where do we stand?

Targeted alpha therapy is an oncological treatment, where cytotoxic doses of alpha radiation are locally delivered to tumor cells, while the surrounding healthy tissue is minimally affected. This therapeutic strategy relies on radiopharmaceuticals made of medically relevant radionuclides chelated by ligands, and conjugated to targeting vectors, which promote the drug accumulation in tumor sites. This review discusses the state-of-the-art in the development of radiopharmaceuticals for targeted alpha therapy, breaking down their key structural components, such as radioisotope, targeting vector, and delivery formulation, and analyzing their pros and cons. Moreover, we discuss current drawbacks that are holding back targeted alpha therapy in the clinic, and identify ongoing strategies in field to overcome those issues, including radioisotope encapsulation in nanoformulations to prevent the release of the daughters. Lastly, we critically discuss potential opportunities the field holds, which may contribute to targeted alpha therapy becoming a gold standard treatment in oncology in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JSC Toxicology Web Site

Data on chemical and biological materials to be flown in the pressurized volumes of habitable spacecraft, including the International Space Station (ISS), are needed by JSC toxicologists to assess the toxicity and assign hazard levels. This document defines submission schedules and establishes requirements for the types and format of these data. JSC 27472 Rev A is a major revision of JSC 25607, "Requirements for Submission of Test Sample-Materials Data for Shuttle Payload Safety Evaluations", dated October 1994, which was subsequently re-issued (September 1996) with a new document number, JSC 27472, but with the same title and date and no revisions. The revisions in the present document have been necessitated by the recent introduction of a two-step process (described in this document) for verification of data for flight materials and by the anticipated needs of the ISS. The requirements -for data submission apply to items which contain liquids, gases, gels, greases, powders/ particulates, radioisotopes, or biological materials and are located in the habitable pressurized volume of ISS or U.S. operated spacecraft. These include, but are not limited to, science payloads, government furnished equipment (GFE), risk mitigation experiments (RmEs), development test objectives (DTOs), detailed supplementary objectives (DSOs), life science experiments, and medical studies.

Garcia, Hector D.↗

System and process for purification of astatine-211 from target materials

A new column-based purification system and approach are described for rapid separation and purification of the alpha-emitting therapeutic radioisotope 211At from dissolved cyclotron targets that provide highly reproducible product results with excellent 211At species distributions and high antibody labeling yields compared with prior art manual extraction results of the prior art that can be expected to enable enhanced production of purified 211At isotope products suitable for therapeutic medical applications such as treatment of cancer in human patients.

O'Hara, Matthew J.↗

System and process for purification of Astatine-211 from target materials

A new column-based purification system and approach are described for rapid separation and purification of the alpha-emitting therapeutic radioisotope 211 At from dissolved cyclotron targets that provide highly reproducible product results with excellent 211 At species distributions and high antibody labeling yields compared with prior art manual extraction results of the prior art that can be expected to enable enhanced production of purified 211 At isotope products suitable for therapeutic medical applications such as treatment of cancer in human patients.

O'Hara, Matthew J.↗

Locoregional Treatment of Glioblastoma With Targeted α Therapy: [213Bi]Bi-DOTA–Substance P Versus [225Ac]Ac-DOTA–Substance P—Analysis of Influence Parameters

Background Glioblastoma (GB) is the most malignant primary brain tumor. Therefore, introduction of new treatment options is critically important. The aim of this study was to assess local treatment with α emitters [ 213 Bi]Bi-DOTA–substance P (SP) and [ 225 Ac]Ac-DOTA-SP. Methods Treatment was performed as salvage therapy in patients with recurrent primary and secondary GB. [ 213 Bi]Bi-DOTA-SP with injected activity 1.85 GBq per cycle was used in 20 primary (48.2 ± 11.8 years old) and in 9 secondary (38.8 ± 10.8 years old) GB patients and [ 225 Ac]Ac-DOTA-SP in 15 primary (45.1 ± 9.9 years old) and in 6 secondary (37.8 ± 6.4 years old) GB patients with a dose escalation scheme (10, 20, and 30 MBq). Results Local treatment with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP was well tolerated with only few adverse effects. There was no statistically significant difference between [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP groups in survival parameters. For primary GB, survival parameters of patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows(in months): progression-free survival time, 2.7 versus 2.4; OS-d (overall survival from time of diagnosis to death from any cause), 23.6 versus 21.0; OS-t (overall survival from the start of treatment to death from any cause), 7.5 versus 5.0; and OS-r (overall survival from recurrence in primary tumors to death from any cause), 10.9 versus 12.0. Survival parameters of secondary GB patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows (in months): progression-free survival time, 5.8 versus 2.4; OS-d, 52.3 versus 65.0; OS-t, 16.4 versus 16.0; and OS-c (overall survival from conversion into secondary GB multiforme to death from any cause), 18.4 versus 36.0. Conclusions The similarity results of 213 Bi or 225 Ac may suggest that the local treatment of brain tumors can be greatly simplified. The experience to date shows that local radioisotope treatment of brain tumors requires further dosimetry studies, taking into account the complexity of biological processes.

Radiology, Nuclear Medicine & Medical Imaging↗

Progress in Development of Methods in Bone Densitometry

The effects of weightlessness and decreased activity on the astronaut's musculoskeletal system during prolonged space flight, missions are of concern to NASA. This problem was anticipated from the knowledge that human subjects lose significant quantities of calcium from the skeleton during periods of bedrest, immobilization, and water immersion. An accurate method of measurement of the changes in mineral content of the skeleton is required not only in the space program but also in the biological, medical, and dental fields for mineral metabolism studies and for studying various pathological conditions of the skeleton and teeth. This method is a difficult one requiring the coordinated efforts of physiologists, biophysicists, radiologists, and clinicians. The densitometry methods reported in this conference which have been used or are being developed include X-ray, beta excited X-rays, radioisotopes, sonic vibration, and neutron activation analysis Studies in the Gemini, Biosatellite, and Apollo flights use the X-ray bone densitometry method which requires making X-rays before and after the flights. An in-flight method of bone densitometry would be valuable, and use of radioisotope sources has been suggested. Many advances in bone densitometry have been made in the last five years, and the urgency of the requirement makes this working conference timely and valuable. In such a rapidly developing field with investigators working independently in a variety of scientific disciplines, a working conference is of great value in exchanging information and ideas, critically evaluating approaches and methods, and pointing out new research pathways.

DENSITOMETER↗

Towards the Stable Chelation of Radioantimony(V) for Targeted Auger Theranostics

Abstract Antimony‐119 ( 119 Sb) is one of the most attractive Auger‐electron emitters identified to date, but it remains practically unexplored for targeted radiotherapy because no chelators have been identified to stably bind this metalloid in vivo. In a departure from current studies focused on chelator development for Sb(III), we explore the chelation chemistry of Sb(V) using the tris‐catecholate ligand TREN‐CAM. Through a combination of radiolabeling, spectroscopic, solid‐state, and computational studies, the radiochemistry and structural chemistry of TREN‐CAM with 1XX/nat Sb(V) were established. The resulting [ 1XX Sb]Sb–TREN‐CAM complex remained intact for several days in human serum, signifying high stability under biological conditions. Finally, the first in vivo single photon emission computed tomography and positron emission tomography imaging studies were carried out using 117 Sb, the diagnostic analogue of 119 Sb. These studies revealed marked differences in the uptake and distribution of activity in mice administered unchelated [ 117 Sb]Sb(OH) 6 – versus [ 117 Sb]Sb–TREN‐CAM, suggesting that 117 Sb is largely retained by TREN‐CAM over the time course of the study. Collectively, these findings demonstrate the most physiologically stable complex of no‐carrier‐added 1XX Sb yet reported, offering new promise for the clinical implementation of radioantimony in nuclear medicine. Our results also establish the feasibility of 117 Sb as an elementally matched partner to 119 Sb for theranostic applications.

Olson, Aeli P. [Department of Medical Physics Univ↗

Production of GMP-Compliant Clinical Amounts of Copper-61 Radiopharmaceuticals from Liquid Targets

PET imaging has gained significant momentum in the last few years, especially in the area of oncology, with an increasing focus on metal radioisotopes owing to their versatile chemistry and favourable physical properties. Copper-61 (t1/2 = 3.33 h, 61% β+, Emax = 1.216 MeV) provides unique advantages versus the current clinical standard (i.e., gallium-68) even though, until now, no clinical amounts of 61Cu-based radiopharmaceuticals, other than thiosemicarbazone-based molecules, have been produced. This study aimed to establish a routine production, using a standard medical cyclotron, for a series of widely used somatostatin analogues, currently labelled with gallium-68, that could benefit from the improved characteristics of copper-61. We describe two possible routes to produce the radiopharmaceutical precursor, either from natural zinc or enriched zinc-64 liquid targets and further synthesis of [61Cu]Cu-DOTA-NOC, [61Cu]Cu-DOTA-TOC and [61Cu]Cu-DOTA-TATE with a fully automated GMP-compliant process. The production from enriched targets leads to twice the amount of activity (3.28 ± 0.41 GBq vs. 1.84 ± 0.24 GBq at EOB) and higher radionuclidic purity (99.97% vs. 98.49% at EOB). Our results demonstrate, for the first time, that clinical doses of 61Cu-based radiopharmaceuticals can easily be obtained in centres with a typical biomedical cyclotron optimised to produce 18F-based radiopharmaceuticals.

Fonseca, Alexandra I. (ORCID:000000031924178X)↗

A Brief Overview of Radiochemistry: Californium-252: Unique and Versatile Man-made Radioisotope

This chapter summarizes radiochemistry and its applications with a focus on areas where computational science can be beneficial. This is presented for a target audience of computational scientists and chemists, and the general public who are interested in radiochemistry topics that may benefit from the use of computational methods. Past, present, and future applications of radiochemistry are presented along with a brief examination of the field’s workforce. Discussions of the current state of several radiochemistry specialty areas are also included. These discussions generally exemplify topics that are readily amenable to computational tools. Topics discussed include medical uses for radioactive materials and related computational needs; the current and future trends in the separations of the f-block elements; production and uses of Californium-252; and the need for exascale computing to solve current problems in the chemistry of Americium and Plutonium.

Ezold, Julie↗

Data for training and testing radiation detection algorithms in an urban environment

The detection, identification, and localization of illicit nuclear materials in urban environments is of utmost importance for national security. Most often, the process of performing these operations consists of a team of trained individuals equipped with radiation detection devices that have built-in algorithms to alert the user to the presence nuclear material and, if possible, to identify the type of nuclear material present. To encourage the development of new detection, radioisotope identification, and source localization algorithms, a dataset consisting of realistic Monte Carlo-simulated radiation detection data from a 2 in. × 4 in. × 16 in. NaI(Tl) scintillation detector moving through a simulated urban environment based on Knoxville, Tennessee, was developed and made public in the form of a Topcoder competition. The methodology used to create this dataset has been verified using experimental data collected at the Fort Indiantown Gap National Guard facility. Realistic signals from special nuclear material and industrial and medical sources are included in the data for developing and testing algorithms in a dynamic real-world background.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗