Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mechanical loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Retrospective Analysis of Inflight Exercise Loading and Physiological Outcomes

Astronauts perform exercise throughout their missions to counter the health declines that occur as a result of long-term exposure to weightlessness. Although all astronauts perform exercise during their missions, the specific prescriptions, and thus the mechanical loading, differs among individuals. For example, inflight ground reaction force data indicate that subject-specific differences exist in foot forces created when exercising on the second-generation treadmill (T2) [1]. The current exercise devices allow astronauts to complete prescriptions at higher intensities, resulting in greater benefits with increased efficiency. Although physiological outcomes have improved, the specific factors related to the increased benefits are unknown. In-flight exercise hardware collect data that allows for exploratory analyses to determine if specific performance factors relate to physiological outcomes. These analyses are vital for understanding which components of exercise are most critical for optimal human health and performance. The relationship between exercise performance variables and physiological changes during flight has yet to be fully investigated. Identifying the critical performance variables that relate to improved physiological outcomes is vital for creating current and future exercise prescriptions to optimize astronaut health. The specific aims of this project are: 1) To quantify the exercise-related mechanical loading experienced by crewmembers on T2 and ARED during their mission on ISS; 2) To explore relationships between exercise loading variables, bone, and muscle health changes during the mission; 3) To determine if specific mechanical loading variables are more critical than others in protecting physiology; 4) To develop methodology for operational use in monitoring accumulated training loads during crew exercise programs. This retrospective analysis, which is currently in progress, is being conducted using data from astronauts that have flown long-duration missions onboard the ISS and have had access to exercise on the T2 and the Advanced Resistive Exercise Device (ARED). The specific exercise prescriptions vary for each astronaut. General exercise summary metrics will be developed to quantify exercise intensities, volumes, and durations for each subject. Where available, ground reaction force data will be used to quantify mechanical loading experienced by each astronaut. These inflight exercise metrics will be investigated relative to changes in pre- to post-flight bone and muscle health to identify which specific variables are related with improved or degraded physiological outcomes. The information generated from this analysis will fill gaps related to typical bone loading characterization, exercise performance capability, exercise volume and efficiency, and importance of exercise hardware. In addition, methods for quantification of exercise loading for use in monitoring the exercise programs during future space missions will be explored with the intent to inform exercise scientists and trainers as to the critical aspects of inflight exercise prescriptions.

Ploutz-Snyder, L. L.↗

Selected Contribution: Skeletal muscle focal adhesion kinase, paxillin, and serum response factor are loading dependent

This investigation examined the effect of mechanical loading state on focal adhesion kinase (FAK), paxillin, and serum response factor (SRF) in rat skeletal muscle. We found that FAK concentration and tyrosine phosphorylation, paxillin concentration, and SRF concentration are all lower in the lesser load-bearing fast-twitch plantaris and gastrocnemius muscles compared with the greater load-bearing slow-twitch soleus muscle. Of these three muscles, 7 days of mechanical unloading via tail suspension elicited a decrease in FAK tyrosine phosphorylation only in the soleus muscle and decreases in FAK and paxillin concentrations only in the plantaris and gastrocnemius muscles. Unloading decreased SRF concentration in all three muscles. Mechanical overloading (via bilateral gastrocnemius ablation) for 1 or 8 days increased FAK and paxillin concentrations in the soleus and plantaris muscles. Additionally, whereas FAK tyrosine phosphorylation and SRF concentration were increased by < or =1 day of overloading in the soleus muscle, these increases did not occur until somewhere between 1 and 8 days of overloading in the plantaris muscle. These data indicate that, in the skeletal muscles of rats, the focal adhesion complex proteins FAK and paxillin and the transcription factor SRF are generally modulated in association with the mechanical loading state of the muscle. However, the somewhat different patterns of adaptation of these proteins to altered loading in slow- vs. fast-twitch skeletal muscles indicate that the mechanisms and time course of adaptation may partly depend on the prior loading state of the muscle.

NASA Discipline Musculoskeletal↗

Temporal gradients in shear stimulate osteoblastic proliferation via ERK1/2 and retinoblastoma protein

Bone cells are subject to interstitial fluid flow (IFF) driven by venous pressure and mechanical loading. Rapid dynamic changes in mechanical loading cause transient gradients in IFF. The effects of pulsatile flow (temporal gradients in fluid shear) on rat UMR106 cells and rat primary osteoblastic cells were studied. Pulsatile flow induced a 95% increase in S-phase UMR106 cells compared with static controls. In contrast, ramped steady flow stimulated only a 3% increase. Similar patterns of S-phase induction were also observed in rat primary osteoblastic cells. Pulsatile flow significantly increased relative UMR106 cell number by 37 and 62% at 1.5 and 24 h, respectively. Pulsatile flow also significantly increased extracellular signal-regulated kinase (ERK1/2) phosphorylation by 418%, whereas ramped steady flow reduced ERK1/2 activation to 17% of control. Correspondingly, retinoblastoma protein was significantly phosphorylated by pulsatile fluid flow. Inhibition of mitogen-activated protein (MAP)/ERK kinase (MEK)1/2 by U0126 (a specific MEK1/2 inhibitor) reduced shear-induced ERK1/2 phosphorylation and cell proliferation. These findings suggest that temporal gradients in fluid shear stress are potent stimuli of bone cell proliferation.

NASA Discipline Cell Biology↗

On local total strain redistribution using a simplified cyclic inelastic analysis based on an elastic solution

Strain redistribution corrections were developed for a simplified inelastic analysis procedure to economically calculate material cyclic response at the critical location of a structure for life prediction purposes. The method was based on the assumption that the plastic region in the structure is local and the total strain history required for input can be defined from elastic finite element analyses. Cyclic stress-strain behavior was represented by a bilinear kinematic hardening model. The simplified procedure has been found to predict stress-strain response with reasonable accuracy for thermally cycled problems but needs improvement for mechanically load cycled problems. This study derived and incorporated Neuber type corrections in the simplified procedure to account for local total strain redistribution under cyclic mechanical loading. The corrected simplified method was exercised on a mechanically load cycled benchmark notched plate problem. Excellent agreement was found between the predicted material response and nonlinear finite element solutions for the problem. The simplified analysis computer program used 0.3 percent of the CPU time required for a nonlinear finite element analysis.

Hwang, S. Y.↗

On local total strain redistribution using a simplified cyclic inelastic analysis based on an elastic solution

Strain redistribution corrections were developed for a simplified inelastic analysis procedure to economically calculate material cyclic response at the critical location of a structure for life prediction purposes. The method was based on the assumption that the plastic region in the structure is local and the total strain history required for input can be defined from elastic finite element analyses. Cyclic stress-strain behavior was represented by a bilinear kinematic hardening model. The simplified procedure has been found to predict stress-strain response with reasonable accuracy for thermally cycled problems but needs improvement for mechanically load cycled problems. This study derived and incorporated Neuber type corrections in the simplified procedure to account for local total strain redistribution under cyclic mechanical loading. The corrected simplified method was exercised on a mechanically load cycled benchmark notched plate problem. Excellent agreement was found between the predicted material response and nonlinear finite element solutions for the problem. The simplified analysis computer program used 0.3 percent of the CPU time required for a nonlinear finite element analysis.

Hwang, S. Y.↗

Probabilistic Assessment of Adaptive Space Truss Configurations for Thermal Buckling Resistance

A three-bay, cantilever truss of a type typically used in space structures, is probabilistically evaluated to configure adaptive/smart/intelligent behavior for resisting thermal buckling. This buckling is due to nonuniform thermal loads and a combination of these loads with applied loads and moments (mechanical loads). For each behavior the scatter (ranges) in buckling loads and member axial forces are probabilistically determined. Sensitivities associated with uncertainties in the structural and material variables that describe the truss, as well as scatter in mechanical and thermal loads, are determined for different probabilities. The relative magnitude of these sensitivities are used to identify significant truss variables that control/classify the truss behavior and cause it to respond as an adaptive/smart/ intelligent structure. Results show that the probabilistic buckling loads increase for adaptive and intelligent truss classifications, with a substantial increase for intelligent trusses. Similarly, the probabilistic member axial forces decrease for each truss classification.

Pai, Shantaram S.↗

Mechanical Unloading Effects Hematopoiesis and Subsequent Red Blood Cell Life Cycle Evaluated at Singe Cell Resolution

Red blood cell formation or erythropoiesis in the bone marrow and exit into circulation are known to be affected by mechanical loading. Specifically, space anemia is a condition observed during prolonged microgravity unloading in which the red blood cell (RBC) mass in circulation is reduced. However, the mechanisms causing space anemia are yet to be clearly established, but may include increased hemolysis of RBC in circulation, decreased RBC production or a combination of both factors. The presentation of space anemia is comparable to chronic anemia conditions associated with aging, disuse, and poor health. Molecular dysregulation in the RBC's life cycle is poorly defined and is a significant concern in the context of disuse anemia as mechanotransduction significantly alters of gene expression, protein synthesis and cell signaling pathways. Our study analyzes mouse single cell RNA sequencing libraries from the bone marrow, circulating blood, and spleen and integrates the RBC lineage populations from the tissues into a RBC life cycle atlas. This study also probes how age at time of spaceflight contributes to the molecular signature of space anemia. The overarching objective of the study is to develop a mechanistic understanding of space anemia and translate the findings to a better understanding of aging, disuse, and poor health-related anemia to defining the role of mechanical loading in health and devise potential therapeutic interventions. Important findings of our study are: 1) that mechanical unloading in microgravity alters the proportion of developmental RBC lineage cells, skewing toward progenitor, indicating that fewer RBCs may be present in blood; 2) that late reticulocyte number is elevated in the bone marrow of older animals, suggesting a failure to enter circulation; and 3) that the molecular signature of the circulating RBCs is not significantly altered in microgravity. However, expression markers for eryptosis and erythrophagocytosis are elevated in circulating and spleen RBCs, suggesting spaceflight may shorten the lifetime of RBCs after exit from the marrow. In conclusion our results suggest early stages of erythropoiesis proliferation and differentiation in the marrow are key factors in space anemia and mechanical loading may be a necessary step of RBC entry in circulation.

blood↗

Thermal-Structural Analysis of PICA Tiles for Solar Tower Test

Thermal protection materials used in spacecraft heatshields are subjected to severe thermal and mechanical loading environments during re-entry into earth atmosphere. In order to investigate the reliability of PICA tiles in the presence of high thermal gradients as well as mechanical loads, the authors designed and conducted solar-tower tests. This paper presents the design and analysis work for this tests series. Coupled non-linear thermal-mechanical finite element analyses was conducted to estimate in-depth temperature distribution and stress contours for various cases. The first set of analyses performed on isolated PICA tile showed that stresses generated during the tests were below the PICA allowable limit and should not lead to any catastrophic failure during the test. The tests results were consistent with analytical predictions. The temperature distribution and magnitude of the measured strains were also consistent with predicted values. The second test series is designed to test the arrayed PICA tiles with various gap-filler materials. A nonlinear contact method is used to model the complex geometry with various tiles. The analyses for these coupons predict the stress contours in PICA and inside gap fillers. Suitable mechanical loads for this architecture will be predicted, which can be applied during the test to exceed the allowable limits and demonstrate failure modes. Thermocouple and strain-gauge data obtained from the solar tower tests will be used for subsequent analyses and validation of FEM models.

Agrawal, Parul↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage, and with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage. In combination with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

Effects of Cyclic Loading on Mechanical Behavior of 24S-T4 and 75S-T6 Aluminum Alloys and SAE 4130 Steel

An investigation was conducted to determine the effects of cyclic loading on the mechanical behavior of 24S-T4 and 75S-T6 aluminum alloys and SAE 4130 steel. Specimens of the three materials were subjected to various numbers of prior fatigue cycles both below and above the fatigue limits. Special slow-bend tests were employed to show the effects of prior cycles of fatigue stressing on the transition temperature to brittle fracture for SAE 4130 steel and on the energy-absorption capacity of the aluminum alloys. Micrographic studies were made to observe and measure crack formation and propagation and additional special tests were conducted to supplement the results of the slow-bend tests. These included Charpy impact tests, mirohardness surveys, tension tests, and fretting-corrosion studies.

STEELS↗

Structural Modeling of an Osteoblast Subjected to Hypergravity Loading

Osteoblasts, the bone-forming cells, are sensitive to altered mechanical loads such as those induced by fluid shear forces and cyclic uniaxial tension and compression. The cytoskeleton is thought to play an important role in a cell's response to mechanical loading and to coordinate cell shape changes. While some theoretical calculations indicate that a cell should not be able to respond to relatively small changes in gravity given the magnitude of forces exerted by intracellular components, osteoblasts have been shown to respond to microgravity. In this study, we investigated whether an osteoblast can sense a constant hypergravity acceleration of 10G. We asked if this load changes the shape of an osteoblast, and if engineering modeling accurately predicts the shape change. We modeled a cell by representing it as a series of axisymmetric shell structures. To test this model empirically, we performed experiments with cultured osteoblasts to measure changes in cell shape resulting from hypergravity loading.

Globus, Ruth K.↗

A Novel Bone Marrow Single Cell Atlas of Mechanotransduction in Microgravity, Normal Gravity, Exercise, and Hindlimb Unloading for WT and CDKN1A-Null Regenerative Mice

Mechanical loading of adult stem cell progenitors is a key factor in modulating their proliferation, differentiation, and tissue regenerative potential, with loading generally promoting tissue formation and unloading mediating tissue loss. To address the role of mechanotransduction in maintaining stem cell-based tissue regenerative health, we generated a single cell transcriptomic atlas mapping responses of femur bone marrow mesenchymal and hematopoietic lineages to a range of altered mechanical loading conditions, both in WT B1629SF2/J mice as well as the p21/CDKN1A-null regenerative mice. We selected the femur marrow compartment as a model because of the diversity and high numbers of stem cell progenitor stages present, and because it undergoes static and cyclic hydrostatic pressure loading associated with weight-bearing and ambulation. Our study included normally loaded mice at 1g, unloading in microgravity during spaceflight as well as tail suspension hindlimb unloading, and voluntary running wheel exercise. Basal, one-year natural aging, and habitat controls were also conducted. Overall, the atlas encompasses 18 different experimental conditions with N=3 mice per condition and includes more than 500,000 single cell expressomes. Key specific findings include: increased mature reticulocyte populations in aging and unloading mice compared to active mice; greater hematopoietic and mesenchymal differentiating progenitors cluster identification in CDKN1A-null samples, especially the exercise model; distinct pseudotime cell trajectory shifts in the hematopoietic lineage for spaceflight and unloaded mice; and shifts in monocytic cell populations toward osteoclastic bone degenerative lineages in unloading and spaceflight samples. Overall mechanical loading shows increased marrow progenitor population differentiation while unloading is associated with increased CDKN1A expression and maintenance of marrow population stemness. Deletion of CDKN1A appears to remove a negative check on progenitor lineages commitment to differentiation. Finally, the Bone Marrow Mechanotransduction Single Cell Atlas will serve as a reference tool for studying marrow regenerative responses across a range of mechanical environments as they relate to CDKN1A status.

single-cell↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

Nonlinear response of boron/aluminum angleplied laminates under cyclic tensile loading: Contributing mechanisms and their effects

The nonlinear response of boron/aluminum angleplied laminates subjected to cyclic loads was investigated. A procedure is outlined and criteria are proposed which can be used to assess the nonlinear response. The procedure consists of testing strategically selected laminate configurations and analyzing the results using composite mechanics. Results from the investigation show the contributions to nonlinear behavior are from: premature random fiber breaks where the ply orientation angle is small relative to the load direction, ply relative rotation at intermediate values of the ply orientation angle, and nonlinear aluminum matrix behavior at large values of the orientation angle. Premature fiber breaks result in progressively more compliant material; large ply relative rotations result in progressively stiffer material; and pronounced matrix nonlinear behavior results in no significant change in the stiffness of the initial load portion.

Chamis, C. C.↗

Nonlinear response of boron/aluminum angleplied laminates under cyclic tensile loading - Contributing mechanisms and their effects

The nonlinear response of boron/aluminum angleplied laminates subjected to cyclic loads was investigated. A procedure is outlined and criteria are proposed which can be used to assess the nonlinear response. The procedure consists of testing strategically selected laminate configurations and analyzing the results using composite mechanics. Results from the investigation show the contributions to nonlinear behavior are from: premature random fiber breaks where the ply orientation angle is small relative to the load direction, ply relative rotation at intermediate values of the ply orientation angle, and nonlinear aluminum matrix behavior at large values of the orientation angle. Premature fiber breaks result in progressively more compliant material; large ply relative rotations result in progressively stiffer material; and pronounced matrix nonlinear behavior results in no significant change in the stiffness of the initial load portion.

Chamis, C. C.↗

Alterations in gut transport of minerals and in binding proteins during simulated weightlessness

The structural components of the skeleton develop and are maintained in a 1 g environment, shaped by the mechanical load to which they are constantly exposed. Altering such a mechanical load by reducing the gravitational force imposed on the system, as in space flight, has profound effects on the skeleton and permits an exploration of the molecular events which regulate normal skeletal homeostasis. The objective was to determine whether simulated weightlessness reduced intestinal calcium transport, and if so, to determine the molecular mechanisms for such an effect. A nonstressful tail suspension in which the rats gained weight normally while suspended was used to simulate weightlessness. A significant change in intestinal calcium transport was not demonstrated. However, a cyclic change in bone formation with suspension was shown. Based on these observations, the objective changed to determination of the hormonal regulation of bone formation during simulated weightlessness.

Bikle, D. D.↗