Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement by laser beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Digital laser-beam deflection sensor

Sensor automatically and accurately measures the two-dimensional deflection angles of a laser beam to provide closed-loop servomechanism control of laser beam directivity.

Fowler, V. J.↗

Saturation of fluorescence in flames with a Gaussian laser beam

The method of saturated fluorescence for measuring species concentrations in flames is usually performed with laser beams that do not provide a constant intensity distribution across the focal volume. Because of the intensity distribution across the beam, the fluorescence signal does not depend on laser power or intensity in the same manner as for uniform illumination. This leads to anomolous apparent saturation intensities. In the following, the effect is considered for atomic fluorescence. Relations for the fluorescence signal under two common excitation geometries are derived and uncertainty relations used to consider the benefits of high laser intensity.

Daily, J. W.↗

Simultaneous transmission/absorption photometry of particle-laden filters from wildland fires during the Biomass Burning Observation Project (BBOP) field campaign

Transmissivity and absorptivity measurements were carried out simultaneously in the visible (wavelength of 532 nm) at laboratory conditions using particle-laden filters obtained from a three-wavelength particle/soot absorption photometer (PSAP). Here, the particles were collected on filters from wildland fires over the Pacific Northwest during the Department of Energy Biomass Burning Observation Project (BBOP) field campaign in 2013. The objective of this investigation was to apply this measurement approach, referred to as simultaneous transmission/absorption photometry (STAP), to estimate the aerosol extinction coefficient from actual field-campaign filter aerosol, and compare results with the PSAP. The STAP approach offers several advantages over the PSAP, including estimation of the extinction coefficient from temperature measurements (avoiding the complexities associated with filter reflectivity/scattering measurements), as well as determination of the filter optical properties and filter effects on particle absorption (resulting in particle absorption enhancement). The experimental arrangement included a laser probe beam impinging normal to the particle-coated surface of a vertically mounted filter, and a thermocouple placed flush in the middle of (and in thermal contact with) the filter uncoated back surface. With this simple arrangement, the transmissivity and absorptivity were determined simultaneously at a given laser beam wavelength. The measurement repeatability was better than 0.3 K (95% confidence level) for temperature and 0.4 mW for laser power. The limit of detection for the extinction coefficient was estimated to be (8–12) Mm -1 (95% confidence level) at about 1.9 mW laser power. The extinction coefficient was determined through measurement of both PSAP blank and exposed filters. Filters were obtained from nine different aircraft flights conducted during the BBOP campaign, representing different flight patterns, days, stages of burning, landscapes, and wildland fires. The STAP extinction coefficient matched the darkness of the filter coating, however the PSAP-filter results did not follow the same order. Although there were differences in transmissivity between the two techniques, the estimated values for absorption coefficient were in good agreement.

54 ENVIRONMENTAL SCIENCES↗

Beam Profile Measurements Utilizing an Amplitude Modulated Pulsed Fiber Laser at PIP2IT

Fermilab is undertaking the development of a new 800 MeV superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a warm front-end generating 2 mA of 2.1 MeV H⁻ followed immediately by a series of superconducting RF cryomodules to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize laser-based monitors to obtain beam profiles via photoionization. This paper will present the results of transverse and longitudinal beam profile measurements using a prototype profile monitor that was tested with 2.1 MeV H⁻ beam at the PIP-II Injector Test (PIP2IT) accelerator. This prototype profile monitor utilizes a high repetition rate fiber laser and fiber optic transport into the PIP2IT enclosure. In addition, results will be shown of narrow-band electron detection from amplitude modulated laser pulses.

43 PARTICLE ACCELERATORS↗

Line spread instrumentation for propagation measurements

A line spread device capable of yielding direct measure of a laser beam's line spread function (LSF) was developed and employed in propagation tests conducted in a wind tunnel to examine optimal acoustical suppression techniques for laser cavities exposed to simulated aircraft aerodynamic environments. Measurements were made on various aerodynamic fences and cavity air injection techniques that effect the LSF of a propagating laser. Using the quiescent tunnel as a control, the relative effect of each technique on laser beam quality was determined. The optical instrument employed enabled the comparison of relative beam intensity for each fence or mass injection. It was found that fence height had little effect on beam quality but fence porosity had a marked effect, i.e., 58% porosity alleviated cavity resonance and degraded the beam the least. Mass injection had little effect on the beam LSF. The use of a direct LSF measuring device proved to be a viable means of determining aerodynamic seeing qualities of flow fields.

Bailey, W. H., Jr.↗

Laboratory measurements of forward and backward scattering of laser beams in water droplet clouds

Many aspects of the forward and backward scattering in dense water droplet clouds were studied using a laboratory scattering facility. This system is configured in a lidar geometry to facilitate comparison of the laboratory results to current lidar oriented theory and measurements. The backscatter measurements are supported with simultaneous measurements of the optical density, mass concentration, and droplet size distribution of the clouds. Measurements of the extinction and backscatter coefficients at several important laser wavelength have provided data on the relationship between these quantities for laboratory clouds at .633, 1.06, and 10.6 microns. The polarization characteristics of the backscatter of 1.06 microns were studied using several different types of clouds. More recently, the laboratory facility was modified to allow range-resolved backscatter measurements at 1.06 microns. Clouds made up of 3 layers, each with its own density, can be constructed. This allows the study of the effect of cloud inhomogeneity on the forward and backscatter.

Smith, R. B.↗

Phase stability of injection-locked beam of semiconductor lasers

An experiment on the phase stability of an injection locked beam was done by using AlGaAs semiconductor lasers. The coherence of two beams from master and slave lasers was measured by interference between the beams in the Twymann-Green interferometer. The phase change of the output beam of the slave laser as a function of the driving current was measured in a Mach-Zehnder interferometer consisting of the master and slave lasers, and a value of 2.5 radians/mA was obtained.

Kwon, Jin Hyuk↗

Laser measuring system for wire-wrapped frame assemblies

The laser measuring system is designed to automatically measure and record the distances between small diameter wires on a wire wrapped grid frame assembly to an accuracy of 0.00635 mm (0.00025 in.). The system utilizes a helium-neon gas laser beam as the measuring instrument with a remote interferometer and retroreflector, a light source and photodetector to detect the wire positions, in conjunction with recording, display and printout units. The laser measuring system is utilized to perform precise automatic measurements for wire application machines or as an automatic feedback device for positioning wires and/or to adjust them for out of tolerance conditions.

Etzel, J. G.↗

Multi-Beam Surface Lidar for Lunar and Planetary Mapping

Surface lidar techniques are now being demonstrated in low Earth orbit with a single beam of pulsed laser radiation at 1064 nm that profiles the vertical structure of Earth surface landforms along the nadir track of a spacecraft. In addition, a profiling laser altimeter, called MOLA, is operating in elliptical Martian orbit and returning surface topography data. These instruments form the basis for suggesting an improved lidar instrument that employs multiple beams for extension of sensor capabilities toward the goal of true, 3-dimensional mapping of the Moon or other similar planetary surfaces. In general the lidar waveform acquired with digitization of a laser echo can be used for laser distance measurement (i.e. range-to-the-surface) by time-of-flight measurement and for surface slope and shape measurements by examining the detailed lidar waveform. This is particularly effective when the intended target is the lunar surface or another planetary body free of any atmosphere. The width of the distorted return pulse is a first order measure of the surface incidence angle, a combination of surface slope and laser beam pointing. Assuming an independent and absolute (with respect to inertial space) measurement of laser beam pointing on the spacecraft, it is possible to derive a surface slope with-respect-to the mean planetary surface or its equipotential gravity surface. Higher-order laser pulse distortions can be interpreted in terms of the vertical relief of the surface or reflectivity variations within the area of the laser beam footprint on the surface.

Bufton, Jack L.↗

Limitations of signal averaging due to temporal correlation in laser remote-sensing measurements

Laser remote sensing involves the measurement of laser-beam transmission through the atmosphere and is subject to uncertainties caused by strong fluctuations due primarily to speckle, glint, and atmospheric-turbulence effects. These uncertainties are generally reduced by taking average values of increasing numbers of measurements. An experiment was carried out to directly measure the effect of signal averaging on back-scattered laser return signals from a diffusely reflecting target using a direct-detection differential-absorption lidar (DIAL) system. The improvement in accuracy obtained by averaging over increasing numbers of data points was found to be smaller than that predicted for independent measurements. The experimental results are shown to be in excellent agreement with a theoretical analysis which considers the effect of temporal correlation. The analysis indicates that small but long-term temporal correlation severely limits the improvement available through signal averaging.

Menyuk, N.↗

NASA Tech Briefs, January 2003

Topics covered include: Optoelectronic Tool Adds Scale Marks to Photographic Images; Compact Interconnection Networks Based on Quantum Dots; Laterally Coupled Quantum-Dot Distributed-Feedback Lasers; Bit-Serial Adder Based on Quantum Dots; Stabilized Fiber-Optic Distribution of Reference Frequency; Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System; Ladar System Identifies Obstacles Partly Hidden by Grass; Survivable Failure Data Recorders for Spacecraft; Fiber-Optic Ammonia Sensors; Silicon Membrane Mirrors with Electrostatic Shape Actuators; Nanoscale Hot-Wire Probes for Boundary-Layer Flows; Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing; Efficient Coupling of Lasers to Telescopes with Obscuration; Aligning Three Off-Axis Mirrors with Help of a DOE; Calibrating Laser Gas Measurements by Use of Natural CO2; Laser Ranging Simulation Program; Micro-Ball-Lens Optical Switch Driven by SMA Actuator; Evaluation of Charge Storage and Decay in Spacecraft Insulators; Alkaline Capacitors Based on Nitride Nanoparticles; Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells; Software for a GPS-Reflection Remote-Sensing System; Software for Building Models of 3D Objects via the Internet; "Virtual Cockpit Window" for a Windowless Aerospacecraft; CLARAty Functional-Layer Software; Java Library for Input and Output of Image Data and Metadata; Software for Estimating Costs of Testing Rocket Engines; Energy-Absorbing, Lightweight Wheels; Viscoelastic Vibration Dampers for Turbomachine Blades; Soft Landing of Spacecraft on Energy-Absorbing Self-Deployable Cushions; Pneumatically Actuated Miniature Peristaltic Vacuum Pumps; Miniature Gas-Turbine Power Generator; Pressure-Sensor Assembly Technique; Wafer-Level Membrane-Transfer Process for Fabricating MEMS; A Reactive-Ion Etch for Patterning Piezoelectric Thin Film; Wavelet-Based Real-Time Diagnosis of Complex Systems; Quantum Search in Hilbert Space; Analytic Method for Computing Instrument Pointing Jitter; and Semiselective Optoelectronic Sensors for Monitoring Microbes.

Source record↗

Development of far infrared attenuation to measure electron densities in cw pin discharge lasers

A two beam attenuation technique was devised to measure electron densities 10 to the 9th power to 10 to the 11th power cm/3 resolved to 1 cm, in a near atmospheric COFFEE laser discharge, using 496 micrometer and 1,220 micrometer radiations from CH3F, optically pumped by a CO2 laser. A far infrared generator was developed which was suitable except for a periodic intensity variation in FIR output deriving from frequency variation of the pump radiation.

Babcock, R. V.↗

Laser beam hydrocarbon detector

Portable instrument passes light from helium-neon laser at a wavelength of 3.39 microns through the atmosphere being monitored and measures attenuation of the laser beam. Since beam attenuation is due almost exclusively to absorption of radiation by hydrocarbons, a quantitative measure of their concentration is available.

Beam, B. H.↗

Automatic Alignment of Displacement-Measuring Interferometer

A control system strives to maintain the correct alignment of a laser beam in an interferometer dedicated to measuring the displacement or distance between two fiducial corner-cube reflectors. The correct alignment of the laser beam is parallel to the line between the corner points of the corner-cube reflectors: Any deviation from parallelism changes the length of the optical path between the reflectors, thereby introducing a displacement or distance measurement error. On the basis of the geometrical optics of corner-cube reflectors, the length of the optical path can be shown to be L = L(sub 0)cos theta, where L(sub 0) is the distance between the corner points and theta is the misalignment angle. Therefore, the measurement error is given by DeltaL = L(sub 0)(cos theta - 1). In the usual case in which the misalignment is small, this error can be approximated as DeltaL approximately equal to -L(sub 0)theta sup 2/2. The control system (see figure) is implemented partly in hardware and partly in software. The control system includes three piezoelectric actuators for rapid, fine adjustment of the direction of the laser beam. The voltages applied to the piezoelectric actuators include components designed to scan the beam in a circular pattern so that the beam traces out a narrow cone (60 microradians wide in the initial application) about the direction in which it is nominally aimed. This scan is performed at a frequency (2.5 Hz in the initial application) well below the resonance frequency of any vibration of the interferometer. The laser beam makes a round trip to both corner-cube reflectors and then interferes with the launched beam. The interference is detected on a photodiode. The length of the optical path is measured by a heterodyne technique: A 100- kHz frequency shift between the launched beam and a reference beam imposes, on the detected signal, an interferometric phase shift proportional to the length of the optical path. A phase meter comprising analog filters and specialized digital circuitry converts the phase shift to an indication of displacement, generating a digital signal proportional to the path length.

Halverson, Peter↗

Laser Pyrometer For Spot Temperature Measurements

Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

Elleman, D. D.↗

Monte Carlo Study of Imaging Plate Response to Laser-Driven Aluminum Ion Beams

We measured the response of BAS-TR imaging plate (IP) to energetic aluminum ions up to 222 MeV, and compared it with predictions from a Monte Carlo simulation code using two different IP response models. Energetic aluminum ions were produced with an intense laser pulse, and the response was evaluated from cross-calibration between CR-39 track detector and IP energy spectrometer. For the first time, we obtained the response function of the BAS-TR IP for aluminum ions with a kinetic energy as high as 222 MeV. On close examination of the two IP response models, we confirm that the exponential model fits our experimental data better. Moreover, we find that the IP sensitivity in the exponential model is nearly constant in this energy range, suggesting that the response function can be determined even with little experimental data.

Won, Junho↗