Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Margin”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reduced OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

07 ISOTOPE AND RADIATION SOURCES↗

A margin based approach to determining sample sizes via tolerance bounds.

This paper proposes a tolerance bound approach for determining sample sizes. With this new methodology we begin to think of sample size in the context of uncertainty exceeding margin. As the sample size decreases the uncertainty in the estimate of margin increases. This can be problematic when the margin is small and only a few units are available for testing. In this case there may be a true underlying positive margin to requirements but the uncertainty may be too large to conclude we have sufficient margin to those requirements with a high level of statistical confidence. Therefore, we provide a methodology for choosing a sample size large enough such that an estimated QMU uncertainty based on the tolerance bound approach will be smaller than the estimated margin (assuming there is positive margin). This ensures that the estimated tolerance bound will be within performance requirements and the tolerance ratio will be greater than one, supporting a conclusion that we have sufficient margin to the performance requirements. In addition, this paper explores the relationship between margin, uncertainty, and sample size and provides an approach and recommendations for quantifying risk when sample sizes are limited.

Newcomer, Justin T.↗

The Role of Margin in Link Design and Optimization

Link analysis is a system engineering process in the design, development, and operation of communication systems and networks. Link models that are mathematical abstractions representing the useful signal power and the undesirable noise and attenuation effects (including weather effects if the signal path transverses through the atmosphere) that are integrated into the link budget calculation that provides the estimates of signal power and noise power at the receiver. Then the link margin is applied which attempts to counteract the fluctuations of the signal and noise power to ensure reliable data delivery from transmitter to receiver. (Link margin is dictated by the link margin policy or requirements.) A simple link budgeting approach assumes link parameters to be deterministic values typically adopted a rule-of-thumb policy of 3 dB link margin. This policy works for most S- and X-band links due to their insensitivity to weather effects. But for higher frequency links like Ka-band, Ku-band, and optical communication links, it is unclear if a 3 dB link margin would guarantee link closure. Statistical link analysis that adopted the 2-sigma or 3-sigma link margin incorporates link uncertainties in the sigma calculation. (The Deep Space Network (DSN) link margin policies are 2-sigma for downlink and 3-sigma for uplink.) The link reliability can therefore be quantified statistically even for higher frequency links. However in the current statistical link analysis approach, link reliability is only expressed as the likelihood of exceeding the signal-to-noise ratio (SNR) threshold that corresponds to a given bit-error-rate (BER) or frame-error-rate (FER) requirement. The method does not provide the true BER or FER estimate of the link with margin, or the required signalto-noise ratio (SNR) that would meet the BER or FER requirement in the statistical sense. In this paper, we perform in-depth analysis on the relationship between BER/FER requirement, operating SNR, and coding performance curve, in the case when the channel coherence time of link fluctuation is comparable or larger than the time duration of a codeword. We compute the "true" SNR design point that would meet the BER/FER requirement by taking into account the fluctuation of signal power and noise power at the receiver, and the shape of the coding performance curve. This analysis yields a number of valuable insights on the design choices of coding scheme and link margin for the reliable data delivery of a communication system - space and ground. We illustrate the aforementioned analysis using a number of standard NASA error-correcting codes.

Cheung, K.↗

Society of Surgical Oncology–American Society for Radiation Oncology Consensus Guideline on Margins for Breast-Conserving Surgery With Whole-Breast Irradiation in Stages I and II Invasive Breast Cancer

Purpose: To convene a multidisciplinary panel of breast experts to examine the relationship between margin width and ipsilateral breast tumor recurrence (IBTR) and develop a guideline for defining adequate margins in the setting of breast conserving surgery and adjuvant radiation therapy. Methods and Materials: A multidisciplinary consensus panel used a meta-analysis of margin width and IBTR from a systematic review of 33 studies including 28,162 patients as the primary evidence base for consensus. Results: Positive margins (ink on invasive carcinoma or ductal carcinoma in situ) are associated with a 2-fold increase in the risk of IBTR compared with negative margins. This increased risk is not mitigated by favorable biology, endocrine therapy, or a radiation boost. More widely clear margins than no ink on tumor do not significantly decrease the rate of IBTR compared with no ink on tumor. There is no evidence that more widely clear margins reduce IBTR for young patients or for those with unfavorable biology, lobular cancers, or cancers with an extensive intraductal component. Conclusions: The use of no ink on tumor as the standard for an adequate margin in invasive cancer in the era of multidisciplinary therapy is associated with low rates of IBTR and has the potential to decrease re-excision rates, improve cosmetic outcomes, and decrease health care costs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

As-Loaded Criticality Margin Assessment of Dual-Purpose Canisters Using UNF-ST&DARDS

A novel assessment has been completed in this paper to determine the previously unquantified and uncredited criticality margin available in as-loaded commercial spent nuclear fuel (SNF) canisters. This assessment was performed as part of a broader effort to assess issues and uncertainties with storage, subsequent transportation, and final disposal of SNF canister systems. Detailed analyses crediting the burnup, initial enrichment, and postirradiation cooling time of actual SNF inventory were performed for 554 SNF canisters stored at 23 commercial reactor sites to determine realistic criticality safety margins. These detailed analyses were automated by the Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS), a comprehensive, integrated data and analysis tool. Calculated, uncredited criticality margins (Δk eff ) with respect to the safety analysis results range from 0 to almost 0.30 Δk eff for normal storage and transportation cases. Calculated eigenvalues (k eff ) range from 0.72 to 1.11 assuming a degraded neutron absorber disposal condition, and they range from 0.94 to 1.20 assuming a degraded basket disposal condition. Calculations with NaCl present in the moderator (which is possible for certain disposal geologies) were used to demonstrate the possibility for subcriticality for degraded cases with a k eff above 0.98 with freshwater. The methods used to calculate k eff for the canisters analyzed in this work are discussed in detail. The results demonstrate that, for the majority of canisters analyzed here, significant uncredited safety margin is available that could be used to compensate for uncertainties in the SNF assembly and canister internal components. These uncertainties are associated with long-term storage and subsequent transportation and disposal. Results also suggest that the inherent margins associated with how canisters are loaded could support future changes in licensing SNF storage and transportation systems to directly or indirectly credit the margins associated with actual SNF characteristics. Finally, ongoing research continues to gather additional data to quantify uncredited safety margins for SNF canisters loaded at other nuclear reactor sites and to explore potential methods for applying this uncredited margin.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Inherent Safety Margins in Loaded Commercial Spent Nuclear Fuel Casks

We completed a novel assessment to determine the unquantified and uncredited safety margins (i.e., the difference between the licensing basis and as-loaded calculations) available in as-loaded spent nuclear fuel (SNF) casks. This assessment was performed as part of a broader effort to assess issues and uncertainties related to the continued safety of casks during extended storage and transportability following extended storage periods. Detailed analyses crediting the actual as-loaded cask inventory were performed for each of the casks at three decommissioned pressurized water reactor (PWR) sites to determine their characteristics relative to regulatory safety criteria for criticality, thermal, and shielding performance. These detailed analyses were performed in an automated fashion by employing a comprehensive and integrated data and analysis tool—Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). Calculated uncredited criticality margins from 0.07 to almost 0.30 Δk eff were observed; calculated decay heat margins ranged from 4 to almost 22 kW (as of 2014); and significant uncredited transportation dose rate margins were also observed. The results demonstrate that, at least for the casks analyzed here, significant uncredited safety margins are available that could potentially be used to compensate for SNF assembly and canister structural performance related uncertainties associated with long-term storage and subsequent transportation. The results also suggest that these inherent margins associated with how casks are loaded could support future changes in cask licensing to directly or indirectly credit the margins. Work continues to quantify the uncredited safety margins in the SNF casks loaded at other nuclear reactor sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrating Safety Assessment Methods using the Risk Informed Safety Margins Characterization (RISMC) Approach

Safety is central to the design, licensing, operation, and economics of nuclear power plants (NPPs). As the current light water reactor (LWR) NPPs age beyond 60 years, there are possibilities for increased frequency of systems, structures, and components (SSC) degradations or failures that initiate safety significant events, reduce existing accident mitigation capabilities, or create new failure modes. Plant designers commonly “over-design” portions of NPPs and provide robustness in the form of redundant and diverse engineered safety features to ensure that, even in the case of well-beyond design basis scenarios, public health and safety will be protected with a very high degree of assurance. This form of defense-in-depth is a reasoned response to uncertainties and is often referred to generically as “safety margin.” Historically, specific safety margin provisions have been formulated primarily based on engineering judgment backed by a set of conservative engineering calculations. The ability to better characterize and quantify safety margin is important to improved decision making about LWR design, operation, and plant life extension. A systematic approach to characterization of safety margins and the subsequent margin management options represents a vital input to the licensee and regulatory analysis and decision making that will be involved. In addition, as research and development (R&D) in the LWR Sustainability (LWRS) Program and other collaborative efforts yield new data, sensors, and improved scientific understanding of physical processes that govern the aging and degradation of plant SSCs needs and opportunities to better optimize plant safety and performance will become known. To support decision making related to economics, readability, and safety, the RISMC Pathway provides methods and tools that enable mitigation options known as margins management strategies. The purpose of the RISMC Pathway R&D is to support plant decisions for risk-informed margin management with the aim to improve economics, reliability, and sustain safety of current NPPs. As the lead Department of Energy (DOE) Laboratory for this Pathway, the Idaho National Laboratory (INL) is tasked with developing and deploying methods and tools that support the quantification and management of safety margin and uncertainty.

97 MATHEMATICS AND COMPUTING↗

Radiosurgery With or Without A 2-mm Margin for 93 Single Brain Metastases

Purpose: Retrospective comparison of Linac radiosurgery (RS) in 93 single brain metastases with or without a 2-mm margin. Patients and Methods: A total of 153 patients had Linac RS (between April 1992 and June 2004), with 139 patients (90.8%) evaluable in June 2005. Sixty-one patients (44%) had extracranial lesions and 65 patients had neurologic symptoms (47%). RS alone: 105 patients (66%); RS +whole brain radiotherapy: 34 patients (24%). Single metastasis: 93/139 patients; classic RS: 42/93 patients; 2-mm margin: 51/93 patients; 30 multiple lesions patients were excluded. Treatment: 15 Mv X-ray Linac, circular minibeams, 8-30 mm, four to six noncoplanar coronal arcs. Isodose was 60-80%; doses were 10-20 Gy. Follow-up: 12 months-13 years; median, 14 months. Results: Local control (LC) was not improved in 51 margin patients vs. 42 classic RS patients: 1 year: 69.1% and 72.4%. Two-year LC rate: 64% and 54.7%, respectively. Survival: median classic RS: 11.3 months; margin RS, 19 months (p = 0.34) and 1 year, 41.6% and 60.2%, respectively. Margin RS patients had a significantly higher rate of severe parenchymal complications: 19.6% vs. 7.1% (p = 0.02); surgery was necessary in 4 of 51 cases vs. 1 of 42 classic RS cases. Conclusion: No increase of 1- and 2-year LC rate in margin RS or survival and median survival: 11.3 vs. 19 months (NS) 2-mm margin associated with more severe parenchymal complications (p = 0.02).This procedure is therefore not recommended. Late CT images and 1-mm margin as recommended by pathologists, use of three-dimensional magnetic resonance imaging and fuzzy method to calculate volumes may yield better results. Stereotactic hypofractionation requires further studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Defined Treatment Margins in Iodine-125 Prostate Brachytherapy

Purpose: Low-dose-rate prostate brachytherapy achieves a very high and effective intraprostatic dose. Implant quality parameters concentrate on the dose received by the prostate (D90, V100) but not that received by the periprostatic tissue. We calculated implant quality parameters, D90 and V100, for the magnetic resonance imaging (MRI)-defined prostate plus 2, 3, and 5 mm. Methods and Materials: A total of 131 men with early-stage prostate cancer treated with iodine-125 brachytherapy represent all those treated with brachytherapy monotherapy in our institution in 2005. Postplan assessment was performed at 1 month using magnetic resonance (MR)-computed tomography (CT) fusion. The prostate V100 and D90 were calculated with 2-, 3-, and 5-mm margins. Results were compared with those in 8 patients with biopsy-proven local failure occurring in an experience of more than 1,100 implants. Results: Mean prostate V100 (SD) and D90 (SD) were 95.6% (4.1) and 117.2% (12.7). For prostate plus a 2-mm margin the D90 was 107.9% (14.3) and for a 3-mm margin 96.0 % (14.0). For prostate plus a 5-mm margin, the D90 was only 78.4% (11.0). The 8 patients experiencing local failure, despite adequate implants, had a lower mean V100 of 91.2% (SD, 2.8; p = 0.0008) and D90 of 103.7% (SD, 8.3; p = 0.002) and significantly inferior margin coverage. Conclusions: Satisfactory coverage of a 2-mm and 3-mm periprostatic margin is obtained with the described planning approach. Coverage falls off significantly by 5 mm. The 8 patients who experienced local failure had significantly lower doses than the margin cohort. Although the V100 and D90 would be considered acceptable, the fall-off in margin coverage was observed by 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses {>=}70 Gy may compensate the effect of close margins {>=}1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses {<=}50 Gy with PHDRB alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the Planning Target Volume in the Treatment of Head and Neck Cancer With Intensity-Modulated Radiotherapy: What Is the Appropriate Expansion Margin in the Setting of Daily Image Guidance?

Purpose: To compare patterns of disease failure among patients treated with intensity-modulated radiotherapy (IMRT) in conjunction with daily image-guided radiotherapy (IGRT) for head and neck cancer, according to the margins used to expand the clinical target volume (CTV) to create a planning target volume (PTV). Methods and Materials: Two-hundred and twenty-five patients were treated with IMRT for squamous cell carcinoma of the head and neck. Daily IGRT scans were acquired using either kilovoltage or megavoltage volumetric imaging prior to each delivered fraction. The first 95 patients were treated with IMRT with 5-mm CTV-to-PTV margins. The subsequent 130 patients were treated using 3-mm PTV expansion margins. Results: Two-year estimates of overall survival, local-regional control, and distant metastasis-free survival were 76%, 78%, and 81%, respectively. There were no differences with respect to any of these endpoints among patients treated with 5-mm and 3-mm PTV expansion margins (p > 0.05, all). The 2-year local-regional control rate for patients treated with IMRT with 5-mm and 3-mm PTV margins was 78% and 78%, respectively (p = 0.96). Spatial evaluation revealed no differences in the incidences of marginal failures among those treated with 5-mm and 3-mm PTV margins. Conclusions: The use of 3-mm PTV expansion margins appears adequate and did not increase local-regional failures among patients treated with IMRT for head and neck cancer. These data demonstrate the safety of PTV reduction of less than 5 mm and support current protocols recommending this approach in the setting of daily IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Local Failure in Breast Cancer Patients With Lobular Carcinoma In Situ at the Final Surgical Margins: Is Re-excision Necessary?

Purpose: To compare the outcome of patients with invasive breast cancer both with and without lobular carcinoma in situ (LCIS)-positive/close surgical margins after breast-conserving treatment. Methods and Materials: We retrospectively studied 2358 patients with T1-T2 invasive breast cancer treated with lumpectomy and radiation therapy from January 1980 to December 2009. Median age was 57 years (range, 24-91 years). There were 82 patients (3.5%) with positive/close LCIS margins (<0.2 cm) and 2232 patients (95.7%) with negative margins. A total of 1789 patients (76%) had negative lymph nodes. Patients who received neoadjuvant chemotherapy were excluded. A total of 1783 patients (76%) received adjuvant systemic therapy. Multivariable analysis (MVA) was performed using Cox's proportional hazards model. Results: The 5-year cumulative incidence of locoregional recurrence (LRR) was 3.2% (95% confidence interval [CI] 2.5%-4.1%) for the 2232 patients with LCIS-negative surgical margins (median follow-up 104 months) and 2.8% (95% CI 0.7%-10.8%) for the 82 patients with LCIS-positive/close surgical margins (median follow-up 90 months). This was not statistically significant (P=.5). On MVA, LCIS-positive margins after the final surgery were not associated with increased risk of LRR (hazard ratio [HR] 3.4, 95% CI 0.5-24.5, P=.2). Statistically significant prognostic variables on Cox's MVA for risk of LRR included systemic therapy (HR 0.5, 95% CI 0.33-0.75, P=.001), number of positive lymph nodes (HR 1.11, 95% CI 1.05-1.18, P=.001), menopausal status (HR 0.96, 95% CI 0.95-0.98, P=.001), and histopathologic grade (grade 3 vs grade 1/2) (HR 2.6, 95% CI 1.4-4.7, P=.003). Conclusion: Our results suggest that the presence of LCIS at the surgical margin after lumpectomy does not increase the risk of LRR or the final outcome. These findings suggest that re-excision or mastectomy in patients with LCIS-positive/close final surgical margins is unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Millimeter-Level Margins on Peripheral Normal Brain Sparing for Gamma Knife Radiosurgery

Purpose: To investigate how millimeter-level margins beyond the gross tumor volume (GTV) impact peripheral normal brain tissue sparing for Gamma Knife radiosurgery. Methods and Materials: A mathematical formula was derived to predict the peripheral isodose volume, such as the 12-Gy isodose volume, with increasing margins by millimeters. The empirical parameters of the formula were derived from a cohort of brain tumor and surgical tumor resection cavity cases (n=15) treated with the Gamma Knife Perfexion. This was done by first adding margins from 0.5 to 3.0 mm to each individual target and then creating for each expanded target a series of treatment plans of nearly identical quality as the original plan. Finally, the formula was integrated with a published logistic regression model to estimate the treatment-induced complication rate for stereotactic radiosurgery when millimeter-level margins are added. Results: Confirmatory correlation between the nominal target radius (ie, R{sub T}) and commonly used maximum target size was found for the studied cases, except for a few outliers. The peripheral isodose volume such as the 12-Gy volume was found to increase exponentially with increasing Δ/R{sub T}, where Δ is the margin size. Such a curve fitted the data (logarithmic regression, R{sup 2} >0.99), and the 12-Gy isodose volume was shown to increase steeply with a 0.5- to 3.0-mm margin applied to a target. For example, a 2-mm margin on average resulted in an increase of 55% ± 16% in the 12-Gy volume; this corresponded to an increase in the symptomatic necrosis rate of 6% to 25%, depending on the Δ/R{sub T} values for the target. Conclusions: Millimeter-level margins beyond the GTV significantly impact peripheral normal brain sparing and should be applied with caution. Our model provides a rapid estimate of such an effect, particularly for large and/or irregularly shaped targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT)

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices - D{sub mean} (mean dose), conformity index (CI), V{sub 70} (volume receiving {>=} 70% of the prescription dose), and V{sub 50} (volume receiving {>=} 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D{sub 95}, V{sub 95}, D{sub max}, D{sub min}, and D{sub mean} of the PTV. The irradiated volume was {approx}23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by {approx}6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V{sub 70}, V{sub 50}, and D{sub mean} were reduced more effectively by a decrease in MLC width, while D{sub mean} of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance. The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Potential of Marginal Land for Cellulosic Feedstock Production and Carbon Sequestration in the United States

Land availability for growing feedstocks at scale is a crucial concern for the bioenergy industry. Feedstock production on land not well-suited to growing conventional crops, or marginal land, is often promoted as ideal, although there is a poor understanding of the qualities, quantity, and distribution of marginal lands in the United States. In this paper, we examine the spatial distribution of land complying with several key marginal land definitions at the United States county, agro-ecological zone, and national scales, and compare the ability of both marginal land and land cover data sets to identify regions for feedstock production. We conclude that very few land parcels comply with multiple definitions of marginal land. Furthermore, to examine possible carbon-flow implications of feedstock production on land that could be considered marginal per multiple definitions, we model soil carbon changes upon transitions from marginal cropland, grassland, and cropland–pastureland to switchgrass production for three marginal land-rich counties. Finally, our findings suggest that total soil organic carbon changes per county are small, and generally positive, and can influence life-cycle greenhouse gas emissions of switchgrass ethanol.

09 BIOMASS FUELS↗

Sci—Thur PM: Planning and Delivery — 04: Respiratory margin derivation and verification in partial breast irradiation

Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20 mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.

60 APPLIED LIFE SCIENCES↗