Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Marching Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Learning and discovering multiple solutions using physics-informed neural networks with random initialization and deep ensemble

In this work we explore the capability of physics-informed neural networks (PINNs) to discover multiple solutions. Many real-world phenomena governed by nonlinear differential equations (DEs), such as fluid flow, exhibit multiple solutions under the same conditions, yet capturing this solution multiplicity remains a significant challenge. A key difficulty lies in providing appropriate initial conditions or guesses, as widely used time-marching schemes and Newton’s method are highly sensitive to these choices when solving complex computational problems. While machine learning models, particularly PINNs, have shown promise in solving DEs, their ability to capture multiple solutions remains underexplored. In this work, we propose a simple and practical approach using PINNs to learn and discover multiple solutions. We first demonstrate that PINNs, when combined with random initialization and deep ensemble method—originally developed for uncertainty quantification—can effectively uncover multiple solutions to nonlinear ordinary and partial DEs. Although training large ensembles of PINNs may appear computationally demanding, this can be done efficiently using vectorization techniques supported by modern deep learning frameworks, allowing many networks to be trained simultaneously. Our approach highlights the critical role of initialization in shaping solution diversity, addressing an often-overlooked aspect of machine learning for scientific computing. Furthermore, we propose utilizing PINN-generated solutions as initial conditions or initial guesses for conventional numerical solvers to enhance accuracy and efficiency in capturing multiple solutions. Extensive numerical experiments, including the Allen–Cahn equation and cavity flow, where our approach successfully identifies both stable and unstable solutions, validate the effectiveness of our method. These findings establish a general and efficient framework for addressing solution multiplicity in nonlinear DEs.

97 MATHEMATICS AND COMPUTING↗

Run-08 pC polarization analysis

In this note we will discuss the analysis of RHIC run 08 pC data that were collected during February 14 - March 10, 2008. An analysis method that is similar to Run 05 and Run 06 was adopted for Run 08 analysis (except few minor changes, which are described below). A detailed analysis note and a NIM article that describe the pC analysis procedure (for run 05 and run 06) can be found elsewhere [1]. In brief, the analysis consists of calibrating the detectors, determining energy corrections (“dead layers”), determining good runs and extracting the polarization from data. Next few sections describe these steps more in detail.

43 PARTICLE ACCELERATORS↗

Run-08 pC polarization analysis - October 16, 2008

In this note we will discuss the analysis of RHIC run 08 pC data that were collected during February 14 - March 10, 2008. An analysis method that is similar to Run 05 and Run 06 was adopted for Run 08 analysis (except few minor changes, which are described below). A detailed analysis note and a NIM article that describe the pC analysis procedure (for run 05 and run 06) can be found elsewhere. In brief, the analysis consists of calibrating the detectors, determining energy corrections ('dead layers'), determining good runs and extracting the polarization from data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE ADJOINT METHOD APPLIED TO TIME-DISTANCE HELIOSEISMOLOGY

For a given misfit function, a specified optimality measure of a model, its gradient describes the manner in which one may alter properties of the system to march toward a stationary point. The adjoint method, arising from partial-differential-equation-constrained optimization, describes a means of extracting derivatives of a misfit function with respect to model parameters through finite computation. It relies on the accurate calculation of wavefields that are driven by two types of sources, namely, the average wave-excitation spectrum, resulting in the forward wavefield, and differences between predictions and observations, resulting in an adjoint wavefield. All sensitivity kernels relevant to a given measurement emerge directly from the evaluation of an interaction integral involving these wavefields. The technique facilitates computation of sensitivity kernels (Frechet derivatives) relative to three-dimensional heterogeneous background models, thereby paving the way for nonlinear iterative inversions. An algorithm to perform such inversions using as many observations as desired is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Pyrgeometer Calibration for DOE-Atmospheric System Research Program Using NREL Method (Presentation)

Presented at the DOE-Atmospheric System Research Program, Science Team Meeting, 15-19 March 2010, Bethesda, Maryland. The presentation: Pyrgeometer Calibration for DOE-Atmospheric System Research program using NREL Method - was presented by Ibrahim Reda and Tom Stoffel on March 15, 2010 at the 2010 ASR Science Team Meeting. March 15-19, 2010, Bethesda, Maryland.

47 OTHER INSTRUMENTATION↗

Neutron Resonance Transmission Analysis (NRTA): A Nondestructive Assay Technique for the Next Generation Safeguards Initiative’s Plutonium Assay Challenge

This is an end-of-year report for a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The first-year goals for this project were modest and included: 1) developing a zero-order MCNP model for the NRTA technique, simulating data results presented in the literature, 2) completing a preliminary set of studies investigating important design and performance characteristics for the NRTA measurement technique, and 3) documentation of this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes a nine month period of work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further Evaluation of the Neutron Resonance Transmission Analysis (NRTA) Technique for Assaying Plutonium in Spent Fuel

This is an end-of-year report (Fiscal Year (FY) 2011) for the second year of effort on a project funded by the National Nuclear Security Administration's Office of Nuclear Safeguards (NA-241). The goal of this project is to investigate the feasibility of using Neutron Resonance Transmission Analysis (NRTA) to assay plutonium in commercial light-water-reactor spent fuel. This project is part of a larger research effort within the Next-Generation Safeguards Initiative (NGSI) to evaluate methods for assaying plutonium in spent fuel, the Plutonium Assay Challenge. The second-year goals for this project included: (1) assessing the neutron source strength needed for the NRTA technique, (2) estimating count times, (3) assessing the effect of temperature on the transmitted signal, (4) estimating plutonium content in a spent fuel assembly, (5) providing a preliminary assessment of the neutron detectors, and (6) documenting this work in an end of the year report (this report). Research teams at Los Alamos National Laboratory (LANL), Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL), and at several universities are also working to investigate plutonium assay methods for spent-fuel safeguards. While the NRTA technique is well proven in the scientific literature for assaying individual spent fuel pins, it is a newcomer to the current NGSI efforts studying Pu assay method techniques having just started in March 2010; several analytical techniques have been under investigation within this program for two to three years or more. This report summarizes work performed over a nine month period from January-September 2011 and is to be considered a follow-on or add-on report to our previous published summary report from December 2010 (INL/EXT-10-20620).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

QXFA 167 Coil Fabrication Report

QXFA is a cosine theta coil used in the MQXFA, a Nb3Sn superconducting accelerator quadrupole magnet to be installed in the High-Luminosity LHC Interaction Regions. A series of MQXFA magnets is fabricated and tested by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). This report details the fabrication process of the QXFA coil (QXFA 167) using Wind-and-React method, conducted from February 6 to March 20, 2025. The content covers coil winding, curing, and reaction, based on the travelers of FNAL as well as the observations and records by the author. The coil fabrication processes following heat reaction, including the impregnation process, are not covered in this report, as they were carried out after March 20.

43 PARTICLE ACCELERATORS↗

DESIGN INFORMATION VERIFICATION FOR NUCLEAR SAFEGUARDS

A critical aspect of international safeguards activities performed by the International Atomic Energy Agency (IAEA) is the verification that facility design and construction (including upgrades and modifications) do not create opportunities for nuclear proliferation. These Design Information Verification activities require that IAEA inspectors compare current and past information about the facility to verify the operator’s declaration of proper use. The actual practice of DIV presents challenges to the inspectors due to the large amount of data generated, concerns about sensitive or proprietary data, the overall complexity of the facility, and the effort required to extract just the safeguards relevant information. Planned and anticipated facilities will (especially in the case of reprocessing plants) be ever larger and increasingly complex, thus exacerbating the challenges. This paper reports the results of a workshop held at the Idaho National Laboratory in March 2009, which considered technologies and methods to address these challenges. The use of 3D Laser Range Finding, Outdoor Visualization System, Gamma-LIDAR, and virtual facility modeling, as well as methods to handle the facility data issues (quantity, sensitivity, and accessibility and portability for the inspector) were presented. The workshop attendees drew conclusions about the use of these techniques with respect to successfully employing them in an operating environment, using a Fuel Conditioning Facility walk-through as a baseline for discussion.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Organ Preservation With Daily Concurrent Chemoradiotherapy Using Superselective Intra-Arterial Infusion via a Superficial Temporal Artery for T3 and T4 Head and Neck Cancer

Purpose: To evaluate the therapeutic results and rate of organ preservation in patients with advanced head and neck cancer treated with superselective intra-arterial chemotherapy via a superficial temporal artery and daily concurrent radiotherapy. Methods and Materials: Between April 2002 and March 2006, 30 patients with T3 or T4a squamous cell carcinoma of the head and neck underwent intra-arterial chemoradiotherapy. Treatment consisted of superselective intra-arterial infusions (docetaxel, total 60 mg/m{sup 2}; cisplatin, total 150 mg/m{sup 2}) and daily concurrent radiotherapy (total, 60 Gy) for 6 weeks. Results: The median follow-up for all patients was 46.2 months (range, 10-90 months). The median follow-up for living patients was 49.7 months (range, 36-90 months). After intra-arterial chemoradiotherapy was administered, primary site complete response was achieved in 30 (100%) of 30 cases. Seven patients (23.3%) died. Using the Kaplan-Meier method, 1-year, 3-year, and 5-year survival rates were 96.7%, 83.1%, and 70.2%, respectively, while 1-year, 3-year, and 5-year local control rates were 83.3%, 79.7%, and 73.0%, respectively. Grade 3 or 4 mucositis occurred in 20 cases (66.7%). Grade 3 toxicities included dysphagia in 20 cases (66.7%), dermatitis in 6 cases (20%), nausea/vomiting in 2 cases (6.7%), and neutropenia and thrombocytopenia in 1 case (3.3%). No osteoradionecrosis of mandible and maxillary bones developed during follow-up. Conclusions: Intra-arterial chemoradiotherapy using a superficial temporal artery provided good overall survival and local control rates. This combination chemoradiotherapy approach can preserve organs and minimize functional disturbance, thus contributing to patients' quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A computational model for nanosecond pulse laser-plasma interactions

A multi-physics numerical model for laser-induced optical breakdown and laser-plasma interaction in a non-equilibrium gas is presented, accounting for: production of priming electrons via multi-photon ionization, energy absorption, cascade ionization, induced hydrodynamic response, and shock formation and propagation. The gas is governed by the Navier-Stokes equations, with non-equilibrium effects taken into account by means of a two-temperature model. The space-time dependence of the laser beam is modeled with a flux-tube formulation for the Radiative Transfer Equation. The flow governing equations are discretized in space using a second-order finite volume method. The semi-discrete equations are marched in time using an implicit-explicit (IMEX) dual time-stepping strategy, where diffusion and chemistry are solved implicitly, whereas convection is explicit. Application to a 20 ns long 50 mJ pulse laser-induced breakdown in quiescent O 2 shows the advantages of this temporal discretization during and just after the laser pulse, while a less-expensive symmetric Strang splitting (with implicit chemistry) is sufficient for the post-breakdown gas dynamics after ≃ 0.1 μs. The integrated model is shown to reproduce key features of corresponding experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Treatment for Intracranial Germinoma: Can We Lower Radiation Dose Without Chemotherapy?

Purpose: To review the effectiveness of reduced-dose and restricted-volume radiation-only therapy in the treatment of intracranial germinoma and to assess the feasibility of reducing or eliminating the use of chemotherapy. Methods and Materials: Between January 1996 and March 2007, a retrospective analysis was performed that included 38 patients who received either reduced radiation alone (30 Gy for 26 patients) or reduced radiation with chemotherapy (n = 12 patients). All 38 patients received extended focal (including whole-ventricle) irradiation and were followed up until February 2008. Overall survival (OS) and relapse-free survival (RFS) rates were calculated. Variables associated with survival were evaluated by univariate Cox proportional hazards regression. Results: Median follow-up was 62.4 months (range, 10.1-142.5 months). The total 5-year OS rate was 93.7%. The 5-year OS and RFS rates for patients receiving radiation only were 100% and 96.2%, respectively. The rates for those receiving radiation plus chemotherapy were 83.3 % and 91.7%, respectively (not statistically significant). No predictive factor was significantly associated with the OS or RFS rate. Chemotherapy had no significant effect on survival but was associated with a higher incidence of treatment-related toxicity. Conclusions: A further decrease in the radiation dose to 30 Gy with whole-ventricle irradiation is sufficient to treat selected patients with intracranial germinoma. Wide-field irradiation or chemotherapy should be avoided as these methods are unnecessary. Thus, reduction of the radiation dose to 30 Gy may be feasible, even without chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Chemoradiotherapy With 5-Fluorouracil and Mitomycin C for Anal Cancer in Immunocompetent Versus Immunodeficient Patients

Purpose: Information is limited as to how we should treat invasive anal squamous cell carcinoma (SCC) in patients with chronic immunosuppression, since the majority of clinical studies to date have excluded such patients. The objective of this study is to compare treatment outcomes in immunocompetent (IC) versus immunodeficient (ID) patients with invasive anal SCC treated similarly with combined modality therapy. Methods and Materials: Between January 1999 and March 2007, a total of 36 consecutive IC and ID patients received concurrent chemoradiotherapy using three-dimensional conformal radiotherapy with infusional 5-fluorouracil and mitomycin C. The IC and ID groups consisted of 19 and 17 patients, respectively, with 14 human immunodeficiency virus-positive (HIV+) and 3 post-solid organ transplant ID patients. There were no significant differences in tumor size, T stage, N stage, chemotherapy doses, or radiation doses between the two groups. Results: With a median follow-up of 3.1 years, no differences were found in overall survival, disease-specific survival, and colostomy-free survival. Three-year overall survival was 83.6% (95% CI = 68.2-100) and 91.7% (95% CI = 77.3-100) in the IC and ID groups, respectively. In addition, there were no differences in acute and late toxicity profiles between the two groups. In the human immunodeficiency virus-positive patients, Cox modeling showed no difference in overall survival by pretreatment CD4 counts (hazard ratio = 0.994, 95% CI = 0.98-1.01). No correlation was found between CD4 counts and the degree of acute toxicities. Conclusion: Our data suggest that standard combined modality therapy with three-dimensional conformal radiotherapy and 5-fluorouracil plus mitomycin C is as safe and effective for ID patients as for IC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reirradiation of Locally Recurrent Nasopharynx Cancer With External Beam Radiotherapy With or Without Brachytherapy

Purpose: To determine survival rates of patients with locally recurrent nasopharynx cancer (LRNPC) treated with modern therapeutic modalities. Methods and Materials: From July 1996 to March 2008, 29 patients were reirradiated for LRNPC. Thirteen patients received combined-modality treatment (CMT), consisting of external beam radiotherapy (EBRT) followed by intracavitary brachytherapy, whereas 16 received EBRT alone. The median age was 50 years, 59% were male, 38% were Asian, 69% had World Health Organization Class III histology, and 86% were treated for their first recurrence. Nine, 6, 8, and 6 patients had recurrent Stage I, II, III, and IV disease, respectively. Patients in the EBRT-alone group had more advanced disease. Median time to reirradiation was 3.9 years. In total, 93% underwent imaging with positron emission tomography and/or magnetic resonance imaging before reirradiation, 83% received intensity-modulated radiotherapy, and 93% received chemotherapy, which was platinum-based in 85% of cases. Results: The median follow-up for all patients was 45 months and for surviving patients was 54 months. Five-year actuarial local control, event-free survival, and overall survival rates were 52%, 44%, and 60%, respectively. No difference was observed between patients treated with EBRT or CMT. Overall survival was superior in patients who achieved local control (p = 0.0003). The incidence of late Grade >=3 events in patients re-treated with EBRT alone was significantly increased compared with those receiving CMT (73% vs. 8%; p = 0.005). Conclusions: In this modern reirradiation series of patients with LRNPC, favorable overall survival compared with historical series was achieved. Patients treated with CMT experienced significantly fewer severe late effects compared with those treated with EBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Study of Daily Irinotecan as a Radiation Sensitizer for Locally Advanced Pancreatic Cancer

Purpose: The study aimed to determine the maximum tolerated dose of daily irinotecan given with concomitant radiotherapy in patients with locally advanced adenocarcinoma of the pancreas. Methods and Materials: Between September 2000 and March 2008, 36 patients with histologically proven unresectable pancreas adenocarcinoma were studied prospectively. Irinotecan was administered daily, 1 to 2 h before irradiation. Doses were started at 6 mg/m{sup 2} per day and then escalated by increments of 2 mg/m{sup 2} every 3 patients. Radiotherapy was administered in 2-Gy fractions, 5 fractions per week, up to a total dose of 50 Gy to the tumor volume. Inoperability was confirmed by a surgeon involved in a multidisciplinary team. All images and responses were centrally reviewed by radiologists. Results: Thirty-six patients were enrolled over a period of 8 years through eight dose levels (6 mg/m{sup 2} to 20 mg/m{sup 2} per day). The maximum tolerated dose was determined to be 18 mg/m{sup 2} per day. The dose-limiting toxicities were nausea/vomiting, diarrhea, anorexia, dehydration, and hypokalemia. The median survival time was 12.6 months with a median follow-up of 53.8 months. The median progression-free survival time was 6.5 months, and 4 patients (11.4%) with very good responses could undergo surgery. Conclusions: The maximum tolerated dose of irinotecan is 18 mg/m{sup 2} per day for 5 weeks. Dose-limiting toxicities are mainly gastrointestinal. Even though efficacy was not the aim of this study, the results are very promising, with a median survival time of 12.6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross-Linked Hyaluronan Gel Reduces the Acute Rectal Toxicity of Radiotherapy for Prostate Cancer

Purpose: To prospectively analyze whether cross-linked hyaluronan gel reduces the mean rectal dose and acute rectal toxicity of radiotherapy for prostate cancer. Methods and Materials: Between September 2008 and March 2009, we transperitoneally injected 9mL of cross-linked hyaluronan gel (Hylaform; Genzyme Corporation, Cambridge, MA) into the anterior perirectal fat of 10 early-stage prostate cancer patients to increase the separation between the prostate and rectum by 8 to 18mm at the start of radiotherapy. Patients then underwent high-dose rate brachytherapy to 2,200cGy followed by intensity-modulated radiation therapy to 5,040cGy. We assessed acute rectal toxicity using the National Cancer Institute Common Terminology Criteria for Adverse Events v3.0 grading scheme. Results: Median follow-up was 3 months. The anteroposterior dimensions of Hylaform at the start and end of radiotherapy were 13 {+-} 3mm (mean {+-} SD) and 10 {+-} 4mm, respectively. At the start of intensity-modulated radiation therapy, daily mean rectal doses were 73 {+-} 13cGy with Hylaform vs. 106 {+-} 20cGy without Hylaform (p = 0.005). There was a 0% incidence of National Cancer Institute Common Terminology Criteria for Adverse Events v3.0 Grade 1, 2, or 3 acute diarrhea in 10 patients who received Hylaform vs. a 29.7% incidence (n = 71) in 239 historical controls who did not receive Hylaform (p = 0.04). Conclusions: By increasing the separation between the prostate and rectum, Hylaform decreased the mean rectal dose. This led to a significant reduction in the acute rectal toxicity of radiotherapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗