Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ParaEMT (NLR's (formerly known as NREL's) EMT Simulator: An Open Source, and HPC-Compatible Large-Scale Power System Electro-Magnetic Transient (EMT) Simulator) [SWR-22-16]

This open-source tool aims to provide a powerful and flexible platform for simulating electromagnetic transients (EMT) of large-scale inverter-based resource (IBR)-dominated power systems. The purpose of making it open source is to foster a community of EMT simulation and assist in exploring new EMT algorithms and applying advanced computational techniques to EMT simulation.

Tan, Jin↗

Electromagnetic pinned solitons for space debris detection

Electromagnetic “pinned” solitons in the form of stationary nonlinear waves are studied within the framework of an inertial magneto-hydrodynamic model. These structures, that can arise when a charged source moves in a magnetized plasma, have a velocity that is equal to the source velocity and, hence, appear as “pinned” structures that envelope the source. We investigate the excitation of such solitons in the Low Earth Orbit region due to the passage of charged orbital debris objects. The spatial size of these electromagnetic solitons, typically of the order of a few ion skin depths, can be very large in this region. Such solitons can be detected using a variety of ground- or orbit-based radio sounding techniques and may provide a convenient additional means of tracking small sized orbital debris objects that are difficult to spot optically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sourcing, Refining and Recycling of Rare-Earth Magnets

Permanent magnets today are used in a wide range of transportation, industrial, residential/commercial, consumer electronics, defense, domestic, data storage, wind energy, and medical markets and applications. There are five classes of commercial permanent magnet materials; however, magnets based on Nd-Fe-B account for over 60% of the global magnet production by value. They typically contain around 31 wt.% of rare earth elements (REEs), principally, Nd and Pr, plus Dy for higher-temperature performance. Nd-Fe-B magnets are forecast to grow throughout this decade, largely driven by the growth in electric vehicles of all types. However, several studies forecast a shortfall of the primary REEs from mined resources. In this paper, the sourcing, processing, and recycling of REEs are discussed. Additionally, presented are the advantages and disadvantages of the major recovery and recycling technologies for REEs.

36 MATERIALS SCIENCE↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ironsand (Titanomagnetite-Titanohematite): Chemistry, Magnetic Properties and Direct Applications for Wireless Power Transfer

Ironsand is an abundant and inexpensive magnetic mineral resource. However, the magnetic properties of unprocessed ironsand are often inadequate for any practical applications. In this work, the applicability of ironsand for use as a component in a soft magnetic composite for large-scale inductive power transfer applications was investigated. After magnetic separation, the chemical, structural and magnetic properties of ironsand sourced from different locations were compared. Differences observed in the DC magnetic properties were consistent with changes in the chemical compositions obtained from X-ray Absorption Near-Edge Spectroscopy (XANES), which suggests varying the titanohematite to titanomagnetite content. Increased content in titanomagnetite and magnetic permeability correlated well with the total Fe content in the materials. The best-performing ironsand with the highest permeability and lowest core losses was used alongside Mn,Zn-Ferrite particles (ranging from ~100 μm to 2 mm) to fabricate toroid cores with varying magnetic material loading. It was shown that ironsand can be used to replace up to 15 wt.% of the magnetic materials with minimal impact on the composite magnetic performance, thus reducing the cost. Ironsand was also used as a supporting material in a single-rail wireless power transfer system, effectively increasing the power transfer, demonstrating potential applications to reduce flux leakage.

36 MATERIALS SCIENCE↗

Clean quantum point contacts in an InAs quantum well grown on a lattice-mismatched InP substrate

Strong spin-orbit coupling, the resulting large g factor, and small effective mass make InAs an attractive material platform for inducing topological superconductivity. The surface Fermi level pinning in the conduction band enables highly transparent ohmic contact without excessive doping. In this study, we investigate electrostatically defined quantum point contacts (QPCs) in a deep-well InAs two-dimensional electron gas. Despite the 3.3% lattice mismatch between the InAs quantum well and the InP substrate, we report clean QPCs with up to eight pronounced quantized conductance plateaus at zero magnetic field. Source-drain dc bias spectroscopy reveals a harmonic confinement potential with a nearly 5 meV subband spacing. We find a many-body exchange interaction enhancement for the out-of-plane g factor |$g^{*}_{⊥}$|=27±1 , whereas the in-plane g factor is isotropic |$g^{*}_{x}$|=|$g^{*}_{y}$|=12±2 , close to the bulk value for InAs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Onset of Plasmoid Reconnection during Magnetorotational Instability

The evolution of current sheets in accretion flows undergoing magnetorotational instability (MRI) is examined through two- and three-dimensional numerical modeling of the resistive MHD equations in global cylindrical geometry. With an initial uniform magnetic field aligned in the vertical (z) direction, MRI produces radially extended toroidal (azimuthal) current sheets. In both 2D and 3D when axisymmetric modes dominate, these current sheets attract each other and merge in the poloidal (rz) plane, driving magnetic reconnection when the Lundquist number S > 3 × 10 2 , making it a possible source of plasmoids (closed magnetic loops) in accretion disks. At high Lundquist numbers in the 2D regime, starting at S = 5 × 10 3 , self-consistent MRI-generated current sheets become thin and subject to plasmoid instability, and therefore spontaneous magnetic reconnection. When nonaxisymmetric 3D modes dominate, turbulence makes the azimuthal current sheets more unstable and stretch vertically. Toroidally extended vertical current sheets in the inner region, as well as larger 3D magnetic islands in the outer regions of the disks are also formed. These findings have strong ramifications for astrophysical disks as potential sources of plasmoids that could cause local heating, particle acceleration, and high energy EM radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation and characterization of magnetized electron beam from a DC high voltage photogun for electron beam cooling application

One of the most challenging requirements for the proposed Electron-Ion Collider is the strong cooling of the proton beam, which is key to achieving the collider’s desired luminosity of order 10 33 -10 34 cm -2 s -1 . Magnetized bunched-beam electron cooling could be a means to achieve the required high luminosity, where strong cooling is accomplished inside a cooling solenoid where the ions co-propagate with an electron beam generated from a source immersed in a magnetic field. To increase the cooling efficiency, a bunched electron beam with high bunch charge and high repetition rate is required. This work describes the production and characterization of magnetized electron beam using a compact 300 kV DC high voltage photogun and bi-alkali antimonide photocathode. Beam magnetization was studied using a diagnostic beamline that includes viewer screens for measuring the shearing angle of the electron beamlet passing through a narrow upstream slit. Simulations and corresponding measurements of beam magnetization are presented as a function of laser spot size and magnetic field strength. Correlated beam emittance with magnetic field (0–0.15 T) at the photocathode was measured for various laser spot sizes. Measurements of photocathode lifetime were carried out at different magnetized electron beam currents up to 28 mA, and bunch charge up to 0.7 nC (not simultaneously).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Hollow-cathode chemical vapor deposition of thick, low-stress diamond-like carbon films

A radio-frequency (RF), hollow-cathode plasma source with confining magnetic field is described for the chemical vapor deposition of thick ( > 10 µm), amorphous diamond-like carbon ablator films for inertial confinement fusion applications. Plasma is characterized by optical emission spectroscopy, while properties of the resultant films are measured by a combination of profilometry, Rutherford backscattering spectrometry, elastic recoil detection analysis, X-ray diffraction, Raman spectroscopy, and atomic force microscopy. The dependence of the deposition rate, film density, elemental composition, self-bias and residual stress is reported as a function of RF power. Higher density films were found when using Ar plasma, than N 2 or H 2 plasma. The coatings produced are x-ray amorphous, exhibit low compressive stress ( ~ 100 MPa), high density ( < 1.7 g/cm 3 ), hydrogen content of ~ 30 at.%, and a low average roughness of 0.75 nm. Finally, applications of these films as tunable-density ablators for inertial confinement fusion experiments are discussed.

36 MATERIALS SCIENCE↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Chiral effects and Joule heating in hot and dense matter

Initial states of dense matter with nonzero electron chiral imbalance could potentially give rise to strong magnetic fields through chiral plasma instability. Previous work indicated that unless chiral chemical potential is as large as the electron vector chemical potential, the growth of magnetic fields due to the instability is washed out by chirality flipping rate enabled by electron mass. We reexamine this claim in a broader range of parameters and find that at higher temperatures the hierarchy is reversed supporting a growing magnetic field for an initial electron chiral chemical potential much smaller than the electron vector chemical potential. Further, we identify a qualitatively new effect relevant for magnetized hot and dense medium where chiral magnetic effect (CME) sourced by density fluctuation acts as a powerful source of Joule heating. Remarkably, even modest chiral chemical potentials (keV) in such environment can deposit energy densities set by the QCD scale in a relatively short time of the order of a few milliseconds or seconds. We speculate how this mechanism makes CME-driven Joule heating a potentially critical ingredient in the dynamics of turbulent density fluctuation of supernovae and neutron star mergers.

Particle astrophysics↗

Conceptual Design of a Conduction-Cooled Superconducting Undulator

In superconducting undulators (SCUs) that are currently operating at the Advanced Photon Source, the undulator magnets are indirectly cooled with liquid helium penetrating through channels in the magnet cores. The liquid helium is stored in a tank that is cooled by cryocoolers. However, a cryogen-free version of a superconducting undulator in which the undulator magnets are conduction-cooled is also possible, as has been realized in the SCUs developed at ANKA. We are currently working on a conceptual design of a conduction-cooled planar superconducting undulator. The measured load lines of cryocoolers and the measured thermal conductance of various thermal links are used in the thermal analysis. Also, various materials for the undulator magnet cores are being considered. This paper reports the thermal design of a conduction-cooled planar SCU.

cryocooler↗

Integrated Fields of Permanent Magnet Dipole Trims

To adjust the integrated dipole field of a magnet (through the longitudinal z axis), pairs of small permanent magnets may be added at the end, symmetrically above and below the axis. If these are sufficiently small, they may be approximated by magnetic dipole point sources.

43 PARTICLE ACCELERATORS↗

“Snowmass’21 Discussions on Future HEP Facilities in the US

The US particle physics community planning exercise (a.k.a. “Snowmass”) is organized every 7 to 9 years to provide a forum for discussions among the entire particle physics community to develop a scientific vision for the future of particle physics in the U.S. and its international partners. The Snowmass'21 Accelerator Frontier activities include discussions on high-energy hadron and lepton colliders, high-intensity beams for neutrino research and for “Physics Beyond Colliders”, accelerator technologies, science, education and outreach as well as the progress of core accelerator technologies, including RF, magnets, targets and sources. Here we summarize the Snowmass'21 discussions on future HEP accelerator facilities.

43 PARTICLE ACCELERATORS↗

Snowmass 21 Discussions on Future Accelerator HEP Facilities

The US particle physics community planning exercise (a.k.a. Snowmass) is organized every 7 to 9 years to provide a forum for discussions among the entire particle physics community to develop a scientific vision for the future of particle physics in the U.S. and its international partners. The Snowmass 21 Accelerator Frontier activities include discussions on high-energy hadron and lepton colliders, high-intensity beams for neutrino research and for Physics Beyond Colliders, accelerator technologies, science, education and outreach as well as the progress of core accelerator technologies, including RF, magnets, targets and sources. Here we summarize the Snowmass 21 discussions on future HEP accelerator facilities.

43 PARTICLE ACCELERATORS↗

Snowmass&#x27;21 Accelerator Frontier

The Particle Physics Community Planning Exercise (a.k.a. “Snowmass”) is the form of organization of regular, every 6 to 8 years, discussions among the entire particle physics community to develop a scientifc vision for the future of particle physics in the U.S. and its international partners. The Snowmass’21 Accelerator Frontier activities include discussions on high-energy hadron and lepton colliders, high-intensity beams for neutrino research and for the “Physics Beyond Colliders”, accelerator technologies, science, education and outreach as well as the progress of core accelerator technology, including RF, magnets, targets and sources.

Gourlay, Stephen Alan↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗