Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MYLAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead of cryogens and measurement of the heat load with a calibrated heat conduction rod. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized Mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the aluminum coating on the Mylar might not be thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature, whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Multilayer insulation↗

Space Weathering Experiments on Spacecraft Materials

A project to investigate space environment effects on specific materials with interest to remote sensing was initiated in 2016. The goal of the project is to better characterize changes in the optical properties of polymers and Mylar, specifically those found in multi-layered spacecraft insulation, due to electron bombardment. Previous analysis shows that chemical bonds break and potentially reform when exposed to high energy electrons. Among other properties these chemical changes altered the optical reflectance as documented in laboratory analysis. This paper presents results of the initial experiment results focused on the exposure of materials to various fluences of high energy electrons, used to simulate a portion of the geosynchronous space environment. The paper illustrates how the spectral reflectance changes as a function of time on orbit with respect to GEO environmental factors and investigates the survivability of the material after multiple electron doses. These results provide a baseline for analysis of aging effects on satellite systems used for remote sensing. They also provide preliminary analysis on what materials are most likely to encompass the high area-to-mass population of space debris in the geosynchronous environment. Lastly, the paper provides the results of the initial experimentation as a proof of concept for space aging on polymers and Mylar for conducting more experiments with a larger subset of spacecraft materials.

Cooper, R.↗

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Cryogenics↗

Inflatable Antenna for CubeSat: Extension of the Previously Developed S-Band Design to the X-Band

The inflatable antenna for CubeSat is a 1 meter antenna reflector designed with one side reflective Mylar, another side clear Mylar with a patch antenna at the focus. The development of this technology responds to the increasing need for more capable communication systems to allow CubeSats to operate autonomously in interplanetary missions. An initial version of the antenna for the S-Band was developed and tested in both anechoic chamber and vacuum chamber. Recent developments in transceivers and amplifiers for CubeSat at X-band motivated the extension from the S-Band to the X-Band. This paper describes the process of extending the design of the antenna to the X-Band focusing on patch antenna redesign, new manufacturing challenges and initial results of experimental tests.

Babuscia, Alessandra↗

Ground demonstration of a spinning solar sail deployment concept

The dynamics of spin-deployment of a subscale solar sail concept (2.5-micron thick mylar film, 80-cm diameter) is investigated herein experimentally in the laboratory environment. To gain insight into the practicality of the deployment scheme, a tether configuration emulating the sail film was first deployed successfully, using the same experiment design. With the exception of some handling issues, the ultra-thin mylar film was also successfully deployed without entanglement. Design details and observations of both experiments are discussed. Additionally, results of analytical simulations to study the dynamics of tether deployment are given.

Leland, R.↗

TechEdSat 7, 10, 13, 15: Exo-brake Experiments on the ISS, First Virgin Orbit, and First Firefly-Alpha Test Flights.

The TechEdSat flight series (TES-n), developed by the Nano Orbital Workshop (NOW) group at NASA Ames, has been studying cube satellite re-entry technologies with a focus on Exo-Brake drag device research. An exo-atmospheric braking device, the Exo-Brake uses the tenuous upper atmosphere acting in a free molecular flow regime to enable controllable adjustment of the drag profile of the host spacecraft, currently enabling rapid disposal of small spacecraft after mission conclusion, and eventual targeted de-orbit to a desired entry point at the Von Karman line, or approximately 100km in altitude. The TES-7 mission, flown on the first successful Virgin Orbit flight January 17, 2021, was injected into a 500km, 61-degree inclination orbit, with an expected orbital lifetime of approximately ten years. After successful deployment of a unique hydrogen gas-cell inflation design ‘disposal’-type Mylar Exo-Brake intended to rapidly de-orbit the spacecraft, the maximum expected orbital lifetime of the TES-7 spacecraft was successfully reduced from ten years to 1.3 years, an 87% reduction in orbit lifetime via a passive, fuel-less system. The subsequent TES-13 mission utilized a new, less complex ‘disposal’-type Exo-Brake design made from collapsible rigid struts rather than inflated struts to reduce the engineering, construction, and safety complexities introduced by the prior hydrogen gas inflation design. The rigid strut Exo-Brake design is stowed via rotational compression and deploys using only stored spring energy once released via electronic actuator. This new rotation compression storage design has become the new Exo-Brake design standard used on TES missions thanks to its simplicity. Following on the success of this new Exo-Brake design demonstrated by TES-13, the design was further refined to enabled active manipulation of the Exo-Brake effective drag area though a winch-like system. Both the TES-10 and TES-15 spacecraft were equipped with geometrically similar Exo-Brake devices capable of such active drag modulation, with the intent of studying the operational impact of having such devices on cube satellite missions. To increase the survival time of the Exo-Brake at low altitudes and thus gain more experiment time and better guidance capability, TES-15 was equipped with a modulated Exo-Brake constructed from 3M™ Nextel™ 440 ceramic oxide fiber, the same fabric material used in the Space Shuttle TPS system, rather than Mylar. After launching on Alpha Flight 2 October 1st, 2022, Firefly’s first successful launch, TES-15 met the same modulation restrictions as TES-10, with modulation prohibited above 200km to avoid possible collision with other spacecraft. In this case, a low deployment orbit caused an extremely short mission life, which, coupled with delayed spacecraft identification, exacerbated collision concerns and caused performance data of the high-temperature Exo-Brake design to be inconclusive. As such, the Nano Orbital Workshop has taken a new approach of only conducting modulated Exo-Brake research on missions deploying below ISS altitude to avoid collision avoidance restrictions, and is working to improve spacecraft identification and location reporting techniques to increase experiment durations. Upcoming TES mission will therefore use one of two classes of Exo-Brake depending on their target altitude, as to be described in the submission.

M Murbach↗

TechEdSat 7, 10, 13, 15: Exo-brake Experiments on the ISS, First Virgin Orbit, and First Firefly-Alpha Test Flights

The TechEdSat flight series (TES-n), developed by the Nano Orbital Workshop (NOW) group at NASA Ames, has been studying cube satellite re-entry technologies with a focus on Exo-Brake drag device research. An exo-atmospheric braking device, the Exo-Brake uses the tenuous upper atmosphere acting in a free molecular flow regime to enable controllable adjustment of the drag profile of the host spacecraft, currently enabling rapid disposal of small spacecraft after mission conclusion, and eventual targeted de-orbit to a desired entry point at the Von Karman line, or approximately 100km in altitude. The TES-7 mission, flown on the first successful Virgin Orbit flight January 17, 2021, was injected into a 500km, 61-degree inclination orbit, with an expected orbital lifetime of approximately ten years. After successful deployment of a unique hydrogen gas-cell inflation design ‘disposal’-type Mylar Exo-Brake intended to rapidly de-orbit the spacecraft, the maximum expected orbital lifetime of the TES-7 spacecraft was successfully reduced from ten years to 1.3 years, an 87% reduction in orbit lifetime via a passive, fuel-less system. The subsequent TES-13 mission utilized a new, less complex ‘disposal’-type Exo-Brake design made from collapsible rigid struts rather than inflated struts to reduce the engineering, construction, and safety complexities introduced by the prior hydrogen gas inflation design. The rigid strut Exo-Brake design is stowed via rotational compression and deploys using only stored spring energy once released via electronic actuator. This new rotation compression storage design has become the new Exo-Brake design standard used on TES missions thanks to its simplicity. Following on the success of this new Exo-Brake design demonstrated by TES-13, the design was further refined to enabled active manipulation of the Exo-Brake effective drag area though a winch-like system. Both the TES-10 and TES-15 spacecraft were equipped with geometrically similar Exo-Brake devices capable of such active drag modulation, with the intent of studying the operational impact of having such devices on cube satellite missions. To increase the survival time of the Exo-Brake at low altitudes and thus gain more experiment time and better guidance capability, TES-15 was equipped with a modulated Exo-Brake constructed from 3M™ Nextel™ 440 ceramic oxide fiber, the same fabric material used in the Space Shuttle TPS system, rather than Mylar. After launching on Alpha Flight 2 October 1st, 2022, Firefly’s first successful launch, TES-15 met the same modulation restrictions as TES-10, with modulation prohibited above 200km to avoid possible collision with other spacecraft. In this case, a low deployment orbit caused an extremely short mission life, which, coupled with delayed spacecraft identification, exacerbated collision concerns and caused performance data of the high-temperature Exo-Brake design to be inconclusive. As such, the Nano Orbital Workshop has taken a new approach of only conducting modulated Exo-Brake research on missions deploying below ISS altitude to avoid collision avoidance restrictions, and is working to improve spacecraft identification and location reporting techniques to increase experiment durations. Upcoming TES mission will therefore use one of two classes of Exo-Brake depending on their target altitude, as to be described in the submission.

Marcus Murbach↗

Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography

The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC{sup x}, taking place along one side of the bed and the second separation would be a time-based separation, LC{sup t}, as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1 mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC{sup x} x LC{sup t} instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

36 MATERIALS SCIENCE↗

Design, characterization, and fabrication of solar-retroreflective cool-wall materials

Raising urban albedo increases the fraction of incident sunlight returned to outer space, cooling cities and their buildings. We evaluated the angular distribution of solar radiation incident on exterior walls in 17 U S. climates to develop performance parameters for solar-retroreflective walls, then applied first-principle physics and ray-tracing simulations to explore designs. Our analysis indicates that retroreflective walls must function at large incidence angles to reflect a substantial portion of summer sunlight, and that this will be difficult to attain with materials that rely on total internal reflection. Gonio-spectrophotometer measurements of the solar spectral bi-directional reflectivity of a bicycle reflector showed little to no retroreflection at large incidence angles. Visual comparisons of retroreflection to specular first-surface reflection for four different retroreflective safety films using violet and green lasers suggest their retroreflection to be no greater than 0.09 at incidence angles up to 45°, and no greater than 0.30 at incidence angles of up to 70°. Attempts to produce a two-surface retroreflector with orthogonal mirror grooves by cutting and polishing an aluminum block indicate that residual surface roughness impedes retroreflection. Ongoing efforts focus on forming orthogonal surfaces with aluminized Mylar film, a material with very high specular reflectance across the solar spectrum. We investigated (1) folding or stamping a free film; (2) adhering the film to a pre-shaped substrate; or (3) attaching the film to a flat ductile substrate, then shaping. The latter two methods were more successful but yielded imperfect right angles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extreme ultraviolet spectroscopy of low-Z ion plasmas for fusion applications

The study of impurities is a key component of magnetic fusion research as it is directly related to plasma properties and steady-state operation. Two of the most important low-Z impurities are carbon and oxygen. The appropriate method of diagnosing these ions in plasmas is extreme ultraviolet (EUV) spectroscopy. In this work the results of two different sets of experiments are considered, and the spectra in a spectral region from 40 to 300 A are analyzed. The first set of experiments was carried out at the Sustained Spheromak Physics Experiment at LLNL, where EUV spectra of oxygen ions were recorded. The second set of experiments was performed at the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR. In particular, Mylar and Teflon slabs were used as targets to produce carbon, oxygen, and fluorine ions of different ionization stages. Nonlocal thermodynamic equilibrium kinetic models of O, F, and C were applied to identify the most diagnostically important spectral features of low-Z ions between 40 to 300 A and to provide plasma parameters for both sets of experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Protection and Improved Performance of Satellite Components as well as Mitigation of Space Environmental Pollution by Plasma Ion Implantation

Three plasma processing systems based on PII technique have been used in the improvement of surface properties of different materials important for aerospace and space applications. Metal plasma PII of Al and Mg was used for surface protection of polymers used in space such as Kapton, Mylar and polyethylene. Al alloys were treated with nitrogen PII for improved resistance to corrosion aiming at aerospace applications. A rigid polymer UHMWPE was also treated in a nitrogen PII to produce a protective layer with DLC. Although not very light, SS304 stainless steel components are being used in a imaging camera in space, and some components made of this material showed endurance to vibration tests after nitrogen PII, therefore being qualified for on-board application.

36 MATERIALS SCIENCE↗

Microbeam Beam Heating Analysis of Thin Foils Using Heat Conduction Theory

The temperature distribution in and near the scan region of an ion microbeam is estimated using heat conduction theory. In the calculation, the energy deposited by a beam spot on a thin foil is treated as a point energy source. The spatial and time dependent temperature contributions from energy deposited by the ion beam rastering in a square scan pattern were then computed. The results showed that for poor conductors, the temperature of the material under the scan region can rise rapidly by up to two orders of magnitude, while that of good conductors remains virtually unchanged. The calculated results were consistent with experimental data where Mylar foils were scanned using an He microbeam and the time for melt through was measured. Radiational cooling effects were also investigated and found to contribute little to the heat losses at typical microbeam beam powers.

36 MATERIALS SCIENCE↗

Simulation Of Human Body Radiation Using Phantom Model On Beam lowbar nrc And Verification On Dosxyz lowbar nrc

The optimum dose can be produced by measuring and analysis of the dose distribution from the source. The energy of the source must be maximum for the target cell, and must minimum for the tissues that surround the target cell. In this study, the phantom model has a cylindrical shape with 20 cm radius and 19 cm depth. The calculation is done where photon beam energy is 6 MeV with 3 different radius beam; 0.3 cm, 5 cm, and 15 cm. The verification was done with a model cube film which was arranged by element voxel which made by Mylar and Ag. The results of this simulation shows the difference dose distribution for radius beam 0.5 cm, 3 cm, and 15 cm that is caused by particle density and penumbra effect. And for all beam radiuses, the maximum dose (100%) happens in 1.5-2 mm depth from film model.

07 ISOTOPE AND RADIATION SOURCES↗

A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus

The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use

Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected to a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Atmospheric pressure dielectric barrier discharges for sterilization and surface treatment

Atmospheric pressure non-thermal dielectric barrier discharges can be generated in different configurations for different applications. For sterilization, a parallel-plate electrode configuration with glass dielectric that discharges in air was used. Gram-negative bacteria (Escherichia coli and Salmonella enteritidis) and Gram-positive bacteria (Bacillus cereus) were successfully inactivated using sinusoidal high voltage of ∼15 kVp-p at 8.5 kHz. In the surface treatment, a hemisphere and disc electrode arrangement that allowed a plasma jet to be extruded under controlled nitrogen gas flow (at 9.2 kHz, 20 kVp-p) was applied to enhance the wettability of PET (Mylar) film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radon emanation based material measurement and selection for the SuperNEMO double beta experiment

The SuperNEMO Demonstrator experiment aims to study the neutrinoless double beta decay of 7 kg of {sup 82}Se in order to reach a limit on the light Majorana neutrino mass mechanism T{sub 1/2} (ββ0ν) > 6.5 10{sup 24} years (90%CL) equivalent to a mass sensitivity mβ{sub β} < 0.20 - 0.40 eV (90%CL) in two years of data taking. The detector construction started in 2014 and its installation in the Laboratoire Souterrain de Modane (LSM) is expected during the course of 2015. The remaining level of {sup 226}Ra ({sup 238}U chain) in the detector components can lead to the emanation of {sup 222}Rn gas. This isotope should be controlled and reduced down to the level of a 150 µBq/m{sup 3} in the tracker chamber of the detector to achieve the physics goals. Besides the HPGe selection of the detector materials for their radiopurity, the most critical materials have been tested and selected in a dedicated setup facility able to measure their {sup 222}Rn emanation level. The operating principle relies on a large emanation tank (0.7m{sup 3}) that allows measuring large material surfaces or large number of construction pieces. The emanation tank is coupled to an electrostatic detector equipped with a silicon diode to perform the alpha spectroscopy of the gas it contains and extract the {sup 222}Rn daughters. The transfer efficiency and the detector efficiency have been carefully calibrated through different methods. The intrinsic background of the system allows one to measure 222Rn activities down to 3 mBq, leading to a typical emanation sensitivity of 20 µBq/m{sup 2}/day for a 30 m{sup 2} surface sample. Several construction materials have been measured and selected, such as nylon and aluminized Mylar films, photomultipliers and tracking of the SuperNEMO Demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗