Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Study of solid rocket motors for a space shuttle booster. Appendix C: Recovery and reuse 120-inch diameter solid rocket motor boosters

A baseline for a space shuttle configuration utilizing four parallel-burn 120-in. diameter SRMS is presented. Topics discussed include parachute system sequence, recovery system development profile, parachute container, and segment and closure recovery operations. A cost analysis for recovery of the SRM stage is presented. It is concluded that from the standpoint of minimum cost and development, parachutes are the best means of achieving SRM recovery. Major SRM components can be reused safely.

Source record↗

Study of solid rocket motors for a space shuttle booster. Appendix E: Environmental impact statement, solid rocket motor, space shuttle booster

An analysis of the combustion products resulting from the solid propellant rocket engines of the space shuttle booster is presented. Calculation of the degree of pollution indicates that the only potentially harmful pollutants, carbon monoxide and hydrochloric acid, will be too diluted to constitute a hazard. The mass of products ejected during a launch within the troposphere is insignificant in terms of similar materials that enter the atmosphere from other sources. Noise pollution will not exceed that obtained from the Saturn 5 launch vehicle.

Source record↗

The large motor plume/material impingement test program at AEDC utilizing the four selected propellants from the small motor tests at MSFC (July, August, and September 1974), section 3

Efforts made to determine the vulnerability of Orbiter and ET materials located at various positions within exhaust plumes from test SSRM's using four different propellant formulations are discussed. Data also cover the effect on TPS materials from a single SSRM plume and dual SSRM plumes, and definitions of test SSRM plume environment at material specimen locations.

Source record↗

Metabolic Rate and Ground Reaction Force During Motorized and Non-Motorized Treadmill Exercise

PURPOSE: To measure vertical ground reaction force (vGRF) and oxygen consumption (VO2) at several velocities during exercise using a ground-based version of the ISS treadmill in the M and NM modes. METHODS: Subjects (n = 20) walked or ran at 0.89, 1.34, 1.79, 2.24, 2.68, and 3.12 m/s while VO2 and vGRF data were collected. VO2 was measured using open-circuit spirometry (TrueOne 2400, Parvo-Medics). Data were averaged over the last 2 min of each 5-min stage. vGRF was measured in separate 15-s bouts at 125 Hz using custom-fitted pressure-sensing insoles (F-Scan Sport Sensors, Tekscan, Inc). A repeated-measures ANOVA was used to test for differences in VO2 and vGRF between M and NM and across speeds. Significance was set at P < 0.05. RESULTS: Most subjects were unable to exercise for 5 min at treadmill speeds above 1.79 m/s in the NM mode; however, vGRF data were obtained for all subjects at each speed in both modes. VO2 was approx.40% higher during NM than M exercise across treadmill speeds. vGRF increased with treadmill speed but was not different between modes. CONCLUSION: Higher VO2 with no change in vGRF suggests that the additional metabolic cost associated with NM treadmill exercise is accounted for in the horizontal forces required to move the treadmill belt. Although this may limit the exercise duration at faster speeds, high-intensity NM exercise activates the hamstrings and plantarflexors, which are not specifically targeted or well protected by other in-flight countermeasures.

Everett, Meghan E.↗

X-57 Cruise Motor and High-Lift Motor Mission Profile Power Analysis

The X-57 Mission Profile Power Analysis was developed to evaluate the X-57 traction battery’s performance against Mod II, Mod III and Mod IV generic flight mission profiles. Traction battery system performance acceptance testing requirements were developed using data generated by this analysis. This analysis was also used to define the maximum power requirements for the traction system components.

Keith Harris↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Development of Ulta-Efficient Electric Motors

Electric motors utilize a large amount of electrical energy in utility and industrial applications. Electric motors constructed with high temperature superconducting (HTS) materials have the potential to dramatically reduce electric motor size and losses. HTS motors are best suited for large motor applications at ratings above 1000 horsepower (hp), where the energy savings from the efficiency improvement can overcome the additional power required to keep the superconductors on the rotor cooled. Large HTS based motors are expected to be half the volume and have half the losses of conventional induction motors of the same rating. For a 5000 hp industrial motor, this energy savings can result in $50,000 in operating cost savings over the course of a single year of operation. Since large horsepower motors utilize (or convert) about 30% of the electrical power generated in the United States and about 70% of large motors are candidates for replacement by HTS motors, the annual energy savings potential through the utilization of HTS motors can be up to $1 Billion in the United States alone. Research in the application of HTS materials to electric motors has lead to a number of HTS motor prototypes yet no industrial HTS motor product has yet been introduced. These motor demonstrations have been synchronous motors with HTS field windings, on the rotor. Figure 1-1 shows a solid model rendering of this type of motor. The rotor winding is made with HTS coils that are held at cryogenic temperature by introducing cooling fluid from the cryocooler to the rotor through a transfer coupling. The stator winding is made of copper wire. The HTS winding is thermally isolated from the warm armature and motor shafts by a vacuum insulation space and through the use of composite torque tubes. The stator in Figure 1-1 is an air core stator in that the stator teeth and a small part of the yoke is made up of nonmagnetic material so the magnetic fields distribute themselves as if in air. Between the HTS field winding and the physical air gap is a series of concentric cylinders that act as vacuum insulation space walls as well as conducting paths for induced currents to flow in order to shield the HTS winding and the rotor cold space from time dependent fields. These time dependent fields may be caused by rotor hunting, during a change in motor load, or by non-fundamental component voltages and currents applied by the inverter. These motors are variable speed controlled by the inverter. Common large motor utility and industrial applications are pump and fan drives that are best suited by a variable speed motor. Inverter control of the HTS motor eliminates the need to design the rotor for line starting, which would dump a large amount of heat into the rotor that would then heavily tax the cryogenic cooling system. The field winding is fed by a brushless exciter that provides DC current to the HTS rotor winding. The stator winding is air or water cooled. Technical and commercial hurdles to industrial HTS motor product introduction and customer acceptance include (1) the high cost of HTS wire and the cryogenic cooling system components, (2) customer concerns about reliability of HTS motors, and (3) the ability to attain the loss reduction potential of large HTS motors. Reliance Electric has demonstrated a number of HTS based electric motors up to a 1000 hp, variable speed synchronous motor with an HTS field winding in the year 2000. In 2001 this motor was tested to 1600 hp with a sinusoidal (constant frequency) supply. Figure 1-2 shows the HTS motor on the dynamometer test stand in the Reliance Electric test lab. The extensive test program of the 1000 hp motor successfully demonstrated the technical feasibility of large HTS motors and the basic technologies involved, however the test results did indicate the need for design refinements. In addition, test results served to identify other more fundamental critical technology issues, and revealed the need to continue research efforts in order to improve future HTS motor first cost, reliability, and performance. The lessons learned from the development and testing of the 1000 hp motor were the basis for the tasks proposed for the project that is being described in this final report. These eight tasks and the technology and commercial issues they address are listed in Table 1-1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ultra-Efficient and Power Dense Electric Motors for U. S. Industry

The primary purpose of this project was to combine the ease-of-installation and ease-of-use attributes of industrial induction motors with the low-loss and small size and weight advantages of PM motors to create an ultra-efficient, high power density industrial motor that can be started across-the-line or operated from a standard, Volts/Hertz drive without the need for a rotor position feedback device. PM motor products that are currently available are largely variable speed motors that require a special adjustable speed drive with rotor position feedback. The reduced size and weight helps to offset the magnet cost in order make these motors commercially viable. The scope of this project covers horsepower ratings from 20 - 500. Prototypes were built and tested at ratings ranging from 30 to 250 HP. Since fans, pumps and compressors make up a large portion of industrial motor applications, the motor characteristics are tailored to those applications. Also, since there is extensive use of adjustable frequency inverters in these applications, there is the opportunity to design for an optimal pole number and operate at other than 60 Hz frequency when inverters are utilized. Designs with four and eight pole configurations were prototyped as part of this work. Four pole motors are the most commonly used configuration in induction motors today. The results of the prototype design, fabrication, and testing were quite successful. The 50 HP rating met all of the design goals including efficiency and power density. Tested values of motor losses at 50 HP were 30% lower than energy efficient induction motors and the motor weight is 35% lower than the energy efficient induction motor of the same rating. Further, when tested at the 30 HP rating that is normally built in this 286T frame size, the efficiency far exceeds the project design goals with 30 HP efficiency levels indicating a 55% reduction in loss compared to energy efficient motors with a motor weight that is a few percentage points lower than the energy efficient motor. This 30 HP rating full load efficiency corresponds to a 46% reduction in loss compared to a 30 HP NEMA Premium ® efficient motor. The cost goals were to provide a two year or shorter efficiency-based payback of a price premium associated with the magnet cost in these motors. That goal is based on 24/7 operation with a cost of electricity of 10 cents per kW-hr. Similarly, the 250 HP prototype efficiency testing was quite successful. In this case, the efficiency was maximized with a slightly less aggressive reduction in active material. The measured full load efficiency of 97.6% represents in excess of a 50% loss reduction compared to the equivalent NEMA Premium Efficiency induction motor. The active material weight reduction was a respectable 14.5% figure. This larger rating demonstrated both the scalability of this technology and also the ability to flexibly trade off power density and efficiency. In terms of starting performance, the 30 - 50 HP prototypes were very extensively tested. The demonstrated capability included the ability to successfully start a load with an inertia of 25 times the motor's own inertia while accelerating against a load torque following a fan profile at the motor's full nameplate power rating. This capability will provide very wide applicability of this motor technology. The 250 HP prototype was also tested for starting characteristics, though without a coupled inertia and load torque. As a result it was not definitively proven that the same 25 times the motor's own inertia could be started and synchronized successfully at 250 HP. Finite element modeling implies that this load could be successfully started, but it has not yet been confirmed by a test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular motors and their functions in plants

Molecular motors that hydrolyze ATP and use the derived energy to generate force are involved in a variety of diverse cellular functions. Genetic, biochemical, and cellular localization data have implicated motors in a variety of functions such as vesicle and organelle transport, cytoskeleton dynamics, morphogenesis, polarized growth, cell movements, spindle formation, chromosome movement, nuclear fusion, and signal transduction. In non-plant systems three families of molecular motors (kinesins, dyneins, and myosins) have been well characterized. These motors use microtubules (in the case of kinesines and dyneins) or actin filaments (in the case of myosins) as tracks to transport cargo materials intracellularly. During the last decade tremendous progress has been made in understanding the structure and function of various motors in animals. These studies are yielding interesting insights into the functions of molecular motors and the origin of different families of motors. Furthermore, the paradigm that motors bind cargo and move along cytoskeletal tracks does not explain the functions of some of the motors. Relatively little is known about the molecular motors and their roles in plants. In recent years, by using biochemical, cell biological, molecular, and genetic approaches a few molecular motors have been isolated and characterized from plants. These studies indicate that some of the motors in plants have novel features and regulatory mechanisms. The role of molecular motors in plant cell division, cell expansion, cytoplasmic streaming, cell-to-cell communication, membrane trafficking, and morphogenesis is beginning to be understood. Analyses of the Arabidopsis genome sequence database (51% of genome) with conserved motor domains of kinesin and myosin families indicates the presence of a large number (about 40) of molecular motors and the functions of many of these motors remain to be discovered. It is likely that many more motors with novel regulatory mechanisms that perform plant-specific functions are yet to be discovered. Although the identification of motors in plants, especially in Arabidopsis, is progressing at a rapid pace because of the ongoing plant genome sequencing projects, only a few plant motors have been characterized in any detail. Elucidation of function and regulation of this multitude of motors in a given species is going to be a challenging and exciting area of research in plant cell biology. Structural features of some plant motors suggest calcium, through calmodulin, is likely to play a key role in regulating the function of both microtubule- and actin-based motors in plants.

Non-NASA Center↗

System and method for motor parameter estimation

A system and method for determining unknown values of certain motor parameters includes a motor input device connectable to an electric motor having associated therewith values for known motor parameters and an unknown value of at least one motor parameter. The motor input device includes a processing unit that receives a first input from the electric motor comprising values for the known motor parameters for the electric motor and receive a second input comprising motor data on a plurality of reference motors, including values for motor parameters corresponding to the known motor parameters of the electric motor and values for motor parameters corresponding to the at least one unknown motor parameter value of the electric motor. The processor determines the unknown value of the at least one motor parameter from the first input and the second input and determines a motor management strategy for the electric motor based thereon.

42 ENGINEERING↗

Brushed permanent magnet DC MLC motor operation in an external magnetic field

Purpose: Linac-MR systems for real-time image-guided radiotherapy will utilize the multileaf collimators (MLCs) to perform conformal radiotherapy and tumor tracking. The MLCs would be exposed to the external fringe magnetic fields of the linac-MR hybrid systems. Therefore, an experimental investigation of the effect of an external magnetic field on the brushed permanent magnet DC motors used in some MLC systems was performed. Methods: The changes in motor speed and current were measured for varying external magnetic field strengths up to 2000 G generated by an EEV electromagnet. These changes in motor characteristics were measured for three orientations of the motor in the external magnetic field, mimicking changes in motor orientations due to installation and/or collimator rotations. In addition, the functionality of the associated magnetic motor encoder was tested. The tested motors are used with the Varian 120 leaf Millennium MLC (Maxon Motor half leaf and full leaf motors) and the Varian 52 leaf MKII MLC (MicroMo Electronics leaf motor) including a carriage motor (MicroMo Electronics). Results: In most cases, the magnetic encoder of the motors failed prior to any damage to the gearbox or the permanent magnet motor itself. This sets an upper limit of the external magnetic field strength on the motor function. The measured limits of the external magnetic fields were found to vary by the motor type. The leaf motor used with a Varian 52 leaf MKII MLC system tolerated up to 450{+-}10 G. The carriage motor tolerated up to 2000{+-}10 G field. The motors used with the Varian 120 leaf Millennium MLC system were found to tolerate a maximum of 600{+-}10 G. Conclusions: The current Varian MLC system motors can be used for real-time image-guided radiotherapy coupled to a linac-MR system, provided the fringe magnetic fields at their locations are below the determined tolerance levels. With the fringe magnetic fields of linac-MR systems expected to be larger than the tolerance levels determined, some form of magnetic shielding would be required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗