At least 91 records · Page 5

Fully automated, fixed exit, in vacuum double-multilayer monochromator for synchrotron-based hard X-ray micro-imaging applications

We present a double multilayer monochromator (DMM) design which has been realized for the BAMline(BESSY-II light source, Germany) as well as in an updated version for the TopoTomo beamline (ANKA light source. Germany)[1-4]. The latter contains two pairs of multilayer stripes in order to avoid absorption edges of the coating material. For both DMMs, the second multilayer offers a meridional bending option for beam compression to increase the available photon flux density. Each multilayer mirror is equipped with a vertical stage for height adjustments allowing for compensation of varying incoming beam heights and giving a certain flexibility choosing the offset. The second multilayer can be moved in the beam direction in order to cover the full energy range available. Furthermore, a white beam option is available.

43 PARTICLE ACCELERATORS↗

Design of soft x-ray wide-band multilayer gratings for constant deviation monochromators

Constant deviation condition performing scanning energy by the rotation of grating around itself is the one of the most practical mounting for grating monochromators. Conventional multilayer coating can obtain high diffraction efficiency merely in a narrow band width. It is found that a new modified multilayer structure on the laminar-type grating intended to enhance the diffraction efficiency for constant deviation condition shows the diffraction efficiency over 5% in a wide band range of 1.5-2.5 keV in calculation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An energy dispersive bent Laue monochromator for K-edge subtraction imaging

K-Edge Subtraction (KES) is a powerful synchrotron imaging method that allows the quantifiable determination of a contrast element (e.g. iodine) and matrix material (usually represented as water) in both projection imaging and computed tomography. A bent Laue monochromator has been developed that has very good focal and energy dispersive properties for KES. Approximately 5% of the vertical beam profile is involved in “edge crossing” energies, thus no splitter is employed as has been done with previous implementations where approximately 33% of the beam size was blocked. The beam can be narrowed vertically allowing a smaller crossover angle than a splitter based system which minimizes artifacts. The combination of good spatial resolution, energy dispersive properties, flux and a unique approach to data analysis make this system nearly ideal for KES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of weak link channel-cut crystals for fast QEXAFS monochromators

A weak link channel-cut crystal, optimized for dedicated Quick EXAFS monochromators and measurements, was designed using finite element analysis. This channel-cut crystal offers precise detuning capabilities to enable suppression of higher harmonics in the virtually monochromatic beam. It was optimized to keep the detuning stable, withstanding the mechanical load, which occurs during oscillations with up to 50 Hz. First tests at DELTA (Dortmund, Germany), proved the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A table-top monochromator for tunable femtosecond XUV pulses generated in a semi-infinite gas cell: Experiment and simulations

We present a new design of a time-preserving extreme-ultraviolet (XUV) monochromator using a semi-infinite gas cell as a source. The performance of this beamline in the photon-energy range of 20 eV–42 eV has been characterized. We have measured the order-dependent XUV pulse durations as well as the flux and the spectral contrast. XUV pulse durations of ≤40 fs using 32 fs, 800 nm driving pulses were measured on the target. The spectral contrast was better than 100 over the entire energy range. A simple model based on the strong-field approximation is presented to estimate different contributions to the measured XUV pulse duration. On-axis phase-matching calculations are used to rationalize the variation of the photon flux with pressure and intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy-resolution X-ray monochromator calibration using the detailed-balance principle

A new method is presented to calibrate an X-ray energy scale with sub-meV relative accuracy by using the detailed-balance principle of the phonon creation and annihilation. This method is conveniently used to define or verify the energy scale of high-energy-resolution monochromators that are used in inelastic X-ray scattering and nuclear resonant inelastic X-ray scattering instruments at synchrotron radiation facilities. This method does not rely on sample properties and its precision only depends on the statistical data quality. Well calibrated instruments are essential for reliable comparison of data sets obtained at different synchrotron radiation beamlines, of data with theoretical predictions, and of data from other techniques such as neutron or light scattering. The principle of the detailed-balance method is described in this paper and demonstrated experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a bent Laue double-crystal beam-expanding monochromator

A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preliminary studies revealed a lack of uniformity in the beam, presumed to be caused by imperfect bending of the silicon crystal wafers used in the system. Results from finite-element analysis of the system predicted that the second crystal would be most severely affected and has been shown experimentally. It has been determined that the majority of the distortion occurs in the second crystal and is likely caused by an imperfection in the surface of the bending frame. Here, measurements were then taken to characterize the bending of the crystal using both mechanical and diffraction techniques. In particular, two techniques commonly used to map dislocations in crystal structures have been adapted to map local curvature of the bent crystals. One of these, a variation of Berg–Berrett topography, has been used to quantify the diffraction effects caused by the distortion of the crystal wafer. This technique produces a global mapping of the deviation of the diffraction angle relative to a perfect cylinder. Finally, this information is critical for improving bending and measuring tolerances of imperfections by correlating this mapping to areas of missing intensity in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Double Crystal Monochromator

A high-precision water-cooled, small offset, double crystal monochromator has been developed for the Advanced Photon Source (APS) UNICAT Sector 34 beamline. The design incorporates the supports and gravity feed water cooling of two diamond or silicon crystals correctly positioned about a common rotation axis so that the incident and diffracted beam do not walk off the edges of the crystals within the energy range 6-15KeV (30{sup o} < q < 11.6{sup o}). In the 34ID implementation, the first crystal sees unfocussed pink beam from an undulator. The second crystal has a {+-}5{sup o} motorized tilt motion around an axis parallel to its face and around the beam direction. In this paper preliminary measurement data obtained from Advanced Photon Source and the detail of the instrument design are presented.

43 PARTICLE ACCELERATORS↗

Single-crystal sapphire microstructure for high-resolution synchrotron X-ray monochromators

We report on the growth and characterization of several sapphire single crystals for the purpose of x-ray optics applications. Structural defects were studied by means of laboratory double-crystal X-ray diffractometry and white beam synchrotron-radiation topography. The investigations confirmed that the main defect types are dislocations. The best quality crystal was grown using the Kyropoulos technique with a dislocation density of 10 2 -10 3 cm -2 and a small area with approximately 2*2 mm 2 did not show dislocation contrast in many reflections and has suitable quality for application as a backscattering monochromator. As a result, a clear correlation between growth rate and dislocation density is observed, though growth rate is not the only parameter impacting the quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The sapphire backscattering monochromator at the Dynamics beamline P01 of PETRA III

Here, we report on a high resolution sapphire backscattering monochromator installed at the Dynamics beamline P01 of PETRA III. The device enables nuclear resonance scattering experiments on M ossbauer isotopes with transition energies between 20 and 60 keV with sub-meV to meV resolution. In a first performance test with 119 Sn nuclear resonance at a X-ray energy of 23.88 keV an energy resolution of 1.34 meV was achieved. Moreover, the device extends the field of nuclear resonance scattering at the PETRA III synchrotron light source to many further isotopes like 151 Eu, 149 Sm, 161 Dy, 125 Te and 121 Sb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing molecular vibrations by monochromated electron microscopy

Chemical bonds fundamentally determine molecular properties and are prevalently characterized by various spectroscopic means such as infrared and Raman spectroscopies. However, the spatial resolution of these conventional approaches is insufficient to reveal nanoscale features. Recently, monochromated electron energy-loss spectroscopy (EELS) in the transmission electron microscope achieved a groundbreaking energy resolution of a few millielectronvolts and enabled direct observation of molecular vibrational spectrum with unmatched spatial resolution. Vibrational EELS is widely applicable to both organic and inorganic matter in the solid state or liquid phase. In this study, we introduce recent advancements and key concepts of this method, compare with other spectroscopic techniques, and discuss future developments for potential applications in research fields centered on catalysts, polymers, and live cells.

Vibrational Spectroscopy↗

Characterization of InGaN/GaN quantum well growth using monochromated valence electron energy loss spectroscopy

The early stages of InGaN/GaN quantum well growth for In-reduced conditions have been investigated for varying thickness and composition of the wells. The structures were studied by monochromated scanning transmission electron microscopy–valence electron energy loss spectroscopy spectrum imaging at high spatial resolution. It is found that beyond a critical well thickness and composition, quantum dots (width >20 nm) are formed inside the well. These are buried by compositionally graded InGaN, which is formed as GaN is grown while residual In is incorporated into the growing structure. It is proposed that these dots act as carrier localization centers inside the quantum wells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗