Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEV RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Seeded FEL Microbunching Experiments at the UCLA Neptune Laboratory

Seeded high-gain FELs, which can generate very powerful radiation pulses in a relatively compact undulator and simultaneously modulate the electron beam longitudinally at the seed wavelength, are important tools for advanced accelerator development. A single-pass 0.5-9 THz FEL amplifier-buncher driven by a regular photoinjector is being built at the UCLA Neptune Laboratory. FEL interactions at 340 {mu}m (1 THz) are considered for the first experiment, since time-resolved measurements of longitudinal current distribution of the bunched beam using the RF deflecting cavity are possible. A design of a 0.2-2.0 {mu}m FEL using the same undulators is presented. In this case the FEL is driven by a high-peak current beam from the laser-plasma accelerator tunable in the 100-300 MeV range.

43 PARTICLE ACCELERATORS↗

SU-F-T-74: Experimental Validation of Monaco Electron Monte Carlo Dose Calculation for Small Fields

Purpose: To verify experimentally the accuracy of Monaco (Elekta) electron Monte Carlo (eMC) algorithm to calculate small field size depth doses, monitor units and isodose distributions. Methods: Beam modeling of eMC algorithm was performed for electron energies of 6, 9, 12 15 and 18 Mev for a Elekta Infinity Linac and all available ( 6, 10, 14 20 and 25 cone) applicator sizes. Electron cutouts of incrementally smaller field sizes (20, 40, 60 and 80% blocked from open cone) were fabricated. Dose calculation was performed using a grid size smaller than one-tenth of the R{sub 80–20} electron distal falloff distance and number of particle histories was set at 500,000 per cm{sup 2}. Percent depth dose scans and beam profiles at dmax, d{sub 90} and d{sub 80} depths were measured for each cutout and energy with Wellhoffer (IBA) Blue Phantom{sup 2} scanning system and compared against eMC calculated doses. Results: The measured dose and output factors of incrementally reduced cutout sizes (to 3cm diameter) agreed with eMC calculated doses within ± 2.5%. The profile comparisons at dmax, d{sub 90} and d{sub 80} depths and percent depth doses at reduced field sizes agreed within 2.5% or 2mm. Conclusion: Our results indicate that the Monaco eMC algorithm can accurately predict depth doses, isodose distributions, and monitor units in homogeneous water phantom for field sizes as small as 3.0 cm diameter for energies in the 6 to 18 MeV range at 100 cm SSD. Consequently, the old rule of thumb to approximate limiting cutout size for an electron field determined by the lateral scatter equilibrium (E (MeV)/2.5 in centimeters of water) does not apply to Monaco eMC algorithm.

60 APPLIED LIFE SCIENCES↗

ASSOCIATION OF SUPRATHERMAL PARTICLES WITH COHERENT STRUCTURES AND SHOCKS

Various mechanisms have been proposed to explain observed suprathermal particle populations in the solar wind, including direct acceleration at flares, stochastic acceleration, shock acceleration, and acceleration by random compression or reconnection sites. Using magnetic field and suprathermal particle data from the Advanced Composition Explorer (ACE), we identify coherent structures and interplanetary shocks, and analyze the temporal association of energetic particle fluxes with these coherent structures. Coherent structures having a range of intensities are identified using the magnetic Partial Variance of Increments statistic, essentially a normalized vector increment. A stronger association of energetic particle flux in the 0.047-4.75 MeV range is found with intense magnetic discontinuities than is found with shocks. Nevertheless, the average profile of suprathermals near shocks is quite consistent with standard models of diffusive shock acceleration, while a significant amount of the energetic particles measured and strong discontinuities are found by ACE within six hours of a shock. This evidence supports the view that multiple mechanisms contribute to the acceleration and transport of interplanetary suprathermal particles.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗

Effective field theory with dibaryon degrees of freedom

We propose a low energy effective field theory of QCD at the scale of pion mass for the N{sub B}=2 sector, N{sub B} being the baryon number, which contains two dibaryon fields in addition to the nucleons and pions. It has a well-defined counting is renormalizable, and the nucleon-nucleon scattering amplitudes are manifestly unitary at leading order. We work out a lower energy effective theory for nucleons with energy much lower than the pion mass and three-momentum comparable to it, which also has a well-defined counting and is renormalizable. The dibaryon fields must also be kept as explicit degrees of freedom in this theory. We calculate the scattering amplitudes at next-to-leading order for the {sup 1}S{sub 0} and {sup 3}S{sub 1} channels in this framework and obtain an excellent description of the phase shifts for center-of-mass energies in the 0-50 MeV range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal fields in UO2 - revisited

We performed inelastic neutron scattering (INS) in order to re-investigate the crystal-field ground state and the level splitting in UO{sub 2}. Previous INS studies on UO{sub 2} by Amorelli et al. [Physical Review B 15, 1989, 1856] uncovered four excitations at low temperatures in the 150-180 meV range. Considering the dipole-allowed transitions, only three of these transitions could be explained by the published crystal-field model. Our INS results on a different UO{sub 2} sample revealed that the unaccounted peak at about 180 meV is a spurious one, and thus not intrinsic to UO{sub 2}. In good agreement with Amoretti's results, we corroborated that the ground-state of UO{sub 2} is the {Lambda}{sub 5} triplet, and we computed that the fourth- and six-order crystal field parameters are V{sub 4} = -116 meV and V{sub 6} = 26 meV, respectively. We also studied the INS response of the non-magnetic U{sub 0.4}Th{sub 0.6}O{sub 2}. The splitting for this thorium-doped compound is similar to the one of UO{sub 2}, which orders antiferromagnetically at low temperatures. Therefore, we can conclude that magnetic interactions only weakly perturb the energy level splitting, which is dominated by strong crystal fields.

36 MATERIALS SCIENCE↗

Detection prospects for the Cosmic Neutrino Background using laser interferometers

The cosmic neutrino background is a key prediction of Big Bang cosmology which has not been observed yet. The movement of the earth through this neutrino bath creates a force on a pendulum, as if it were exposed to a cosmic wind. We revise here estimates for the resulting pendulum acceleration and compare it to the theoretical sensitivity of an experimental setup where the pendulum position is measured using current laser interferometer technology as employed in gravitational wave detectors. We discuss how a significant improvement of this setup can be envisaged in a micro gravity environment. The proposed setup could also function as a dark matter detector in the sub-MeV range, which currently eludes direct detection constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Measurement of Low Energy Neutrino Interactions

Neutrino interactions in the few to few tens of MeV range are of importance for several physics topics, including solar, supernova and reactor neutrinos, as well as future proposed oscillation and Standard Model test experiments. Although interaction cross-sections for some simple targets are well understood, very little experimental data exist for interactions with nuclei. This talk will discuss the motivation for measuring low energy neutrino interactions, the state of knowledge, and possible future strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma ray measurements with photoconductive detectors using a dense plasma focus

Photons in the MeV range emitted from the dense plasma focus (DPF) at the NSTec North Las Vegas Facility have been measured with both neutron-damaged GaAs and natural diamond photoconductive detectors (PCDs). The DPF creates or “pinches” plasmas of various gases (e.g., H{sub 2}, D{sub 2}, Ne, Ar., etc.) that have enough energy to create MeV photons from either bremsstrahlung and/or (n,n{sup ′}) reactions if D{sub 2} gas is used. The high bandwidth of the PCDs enabled the first ever measurement of the fast micro-pinches present in DPF plasmas. Comparisons between a slower more conventional scintillator/photomultiplier tube based nuclear physics detectors were made to validate the response of the PCDs to fast intense MeV photon signals. Significant discrepancies in the diamond PCD responses were evident.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Equilibration in fermionic systems

Highlights: •Local equilibration in finite fermion systems is based on a nonlinear diffusion equation. •The fermionic diffusion equation is solved analytically in closed form. •The exact solutions agree with the numerical results. •Particle-number and energy conservation are shown to be fulfilled. •The model is applied to hadrons at low energies, and relativistic quarks. -- Abstract: The time evolution of a finite fermion system towards local statistical equilibrium is investigated using analytical solutions of a nonlinear partial differential equation that had been derived earlier from the Boltzmann collision term. The solutions of this fermionic diffusion equation are rederived in closed form, evaluated exactly for simplified initial conditions, and applied to hadron systems at low energies in the MeV-range, as well as to quark systems at relativistic energies in the TeV-range where antiparticle production is abundant. Conservation laws for particle number including created antiparticles, and for the energy are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LARGE SOLAR ENERGETIC PARTICLE EVENTS ASSOCIATED WITH FILAMENT ERUPTIONS OUTSIDE ACTIVE REGIONS

We report on four large filament eruptions (FEs) from solar cycles 23 and 24 that were associated with large solar energetic particle (SEP) events and interplanetary type II radio bursts. The post-eruption arcades corresponded mostly to C-class soft X-ray enhancements, but an M1.0 flare was associated with one event. However, the associated coronal mass ejections (CMEs) were fast (speeds ∼ 1000 km s{sup −1}) and appeared as halo CMEs in the coronagraph field of view. The interplanetary type II radio bursts occurred over a wide wavelength range, indicating the existence of strong shocks throughout the inner heliosphere. No metric type II bursts were present in three events, indicating that the shocks formed beyond 2–3 Rs. In one case, there was a metric type II burst with low starting frequency, indicating a shock formation height of ∼2 Rs. The FE-associated SEP events did have softer spectra (spectral index >4) in the 10–100 MeV range, but there were other low-intensity SEP events with spectral indices ≥4. Some of these events are likely FE-SEP events, but were not classified as such in the literature because they occurred close to active regions. Some were definitely associated with large active region flares, but the shock formation height was large. We definitely find a diminished role for flares and complex type III burst durations in these large SEP events. Fast CMEs and shock formation at larger distances from the Sun seem to be the primary characteristics of the FE-associated SEP events.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrinos at the Spallation Neutron Source

The Spallation Neutron Source at Oak Ridge will provide an intense source of neutrinos in the tens of MeV range, which nicely overlaps with the supernova neutrino energy range. I will describe the Neutrinos at the SNS ({nu}SNS) program planned to exploit this high power, high quality source for studies of neutrino cross-sections relevant for supernova neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary

The first International GLAST Symposium was held at Stanford, with less than a year to launch. Recent advances in the TeV and MeV ranges augur well for GLAST making major discoveries in GeV astronomy. Expectations for observations of several source types and backgrounds are summarized, along with some remaining organizational challenges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antineutrino analysis for continuous monitoring of nuclear reactors: Sensitivity study

This paper explores the various contributors to uncertainty on predictions of the antineutrino source term which is used for reactor antineutrino experiments and is proposed as a safeguard mechanism for future reactor installations. The errors introduced during simulation of the reactor burnup cycle from variation in nuclear reaction cross sections, operating power, and other factors are combined with those from experimental and predicted antineutrino yields, resulting from fissions, evaluated, and compared. The most significant contributor to uncertainty on the reactor antineutrino source term when the reactor was modeled in 3D fidelity with assembly-level heterogeneity was found to be the uncertainty on the antineutrino yields. Using the reactor simulation uncertainty data, the dedicated observation of a rigorously modeled small, fast reactor by a few-ton near-field detector was estimated to offer reduction of uncertainty on antineutrino yields in the 3.0–6.5 MeV range to a few percent for the primary power-producing fuel isotopes, even with zero prior knowledge of the yields.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of early dark matter halos on reionization

The annihilation of dark matter particles releases energy, ionizing some of the gas in the Universe. We investigate the effect of dark matter halos on reionization. We show that the effect depends on the assumed density profile, the particle mass, and the assumed minimum halo mass. For Navarro-Frenk-White halos and typical WIMPs, we find the effect to be quite small. However, light dark matter candidates in the MeV range can contribute significantly to reionization and can make an important contribution to the measured optical depth. This effect may be used to constrain light dark matter models. We also study the effect of varying the halo density profile on reionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of Cyclotron Radiation from MeV-Scale e ± following Nuclear β Decay

We present an apparatus for detection of cyclotron radiation yielding a frequency-based β ± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β – ’s from 6 He and β + ’s from 19 Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.

43 PARTICLE ACCELERATORS↗