Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

XV-15 Tilt Rotor Research Aircraft Photogrammetry and Metrology Measurement

A new measurement capability was created by combining photogrammetry and metrology techniques to accurately measure one half of the XV-15 Tilt Rotor Research Aircraft at the Smithsonian’s Udvar-Hazy museum. The challenges imposed by the fuselage and surrounding environment at Udvar-Hazy were overcome by careful application of photogrammetry and metrology techniques. Data analyses and processing included the use of multiple reverse engineering programs to accurately generate a complete 3-dimensional water-tight geometry of the aircraft and rotor blade. This paper describes the photogrammetry and metrology measurement systems, technology and hardware set-up, data analysis and processing methods, future work, and lessons learned. In addition, selected measurement results of the fuselage and rotor blade are presented.

XV-15↗

Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

07 ISOTOPE AND RADIATION SOURCES↗

Metrology Techniques for the Assembly of NCSX

In support of the National Compact Stellerator Experiment (NCSX), stellerator assembly activities continued this past year at the Princeton Plasma Physics Laboratory (PPPL) in partnership with the Oak Ridge National Laboratory (ORNL). The construction program saw the completion of the first two Half Field-Period Assemblies (HPA), each consisting of three modular coils. The full machine includes six such sub-assemblies. A single HPA consists of three of the NCSX modular coils wound and assembled at PPPL. These geometrically-complex threedimensional coils were wound using computer-aided metrology and CAD models to tolerances within +/- 0.5mm. The assembly of these coils required similar accuracy on a larger scale with the added complexity of more individual parts and fewer degrees of freedom for correction. Several new potential positioning issues developed for which measurement and control techniques were developed. To accomplish this, CAD coordinate-based computer metrology equipment and software similar to the solutions employed for winding the modular coils was used. Given the size of the assemblies, the primary tools were both interferometeraided and Absolute Distance Measurement (ADM)-only based laser trackers. In addition, portable Coordinate Measurement Machine (CMM) arms and some novel indirect measurement techniques were employed. This paper will detail both the use of CAD coordinate-based metrology technology and the techniques developed and employed for dimensional control of NSCX subassemblies. The results achieved and possible improvements to techniques will be discussed.

Laser Tracker↗

Easy parallel screening of reagent stability, quality control, and metrology in solid phase peptide synthesis (SPPS) and peptide couplings for microarrays

Evaluating the stability of coupling reagents, quality control (QC), and surface functionalization metrology are all critical to the production of high quality peptide microarrays. We describe a broadly applicable screening technique for evaluating the fidelity of solid phase peptide synthesis (SPPS), the stability of activation/coupling reagents, and a microarray surface metrology tool. This technique was used to assess the stability of the activation reagent 1-{[1-(Cyano-2-ethoxy-2-oxo-ethylidenaminooxy)dimethylamino-morpholinomethylene]}methaneaminiumHexafluorophosphate (COMU) (Sigma-Aldrich, St. Louis, MO, USA) by SPPS of Leu-Enkephalin (YGGFL) or the coupling of commercially synthesized YGGFL peptides to (3-aminopropyl)triethyoxysilane-modified glass surfaces. Coupling efficiency was quantitated by fluorescence signaling based on immunoreactivity of the YGGFL motif. It was concluded that COMU solutions should be prepared fresh and used within 5 h when stored at ~23 °C and not beyond 24 h if stored refrigerated, both in closed containers. Caveats to gauging COMU stability by absorption spectroscopy are discussed. Commercial YGGFL peptides needed independent QC, due to immunoreactivity variations for the same sequence synthesized by different vendors. This technique is useful in evaluating the stability of other activation/coupling reagents besides COMU and as a metrology tool for SPPS and peptide microarrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation approach for quality assurance of additive manufactured parts based on optical metrology

Surface topography and surface finish are two significant factors for evaluating the quality of products in additive manufacturing (AM). AM parts are fabricated layer by layer, which is quite different from traditional formative or subtractive methods. Despite rapid progress in additive manufacturing and associated optical metrology for quality control and in-situ monitoring, limited research has been conducted to investigate the reliability of 3D surface measurement data. The surface topologies scanned by multiple optical systems demonstrated significant differences due to varying sampling mechanisms, resolutions, system noises, etc. The 3D datasets should be trustworthy in order to extract parameters for quality assurance or feedback control from 3D surface measurements. In this paper, we set up new standards to evaluate the reliability of 3D surface measurement data and analyze the variation in the topographical profile. In this study, two non-contact optical methods based on Focus Variation Microscopy (FVM) and Structured Light System (SLS) were adopted to measure the surface topography of the target components. The two optical metrology systems generated two entirely different point cloud datasets. Statistical methods were applied to test the difference between the data obtained from the two systems. By using a data analytics approach for comparison, it was found that the surface roughness estimated from the point cloud data sets of FVM and SLS has no significant difference, though the point cloud data sets were completely different. This paper provides standard validation approach to evaluate the plausibility of metrology data from in-situ real-time surface analysis for process planning of AM.

36 MATERIALS SCIENCE↗

Moiré metrology of energy landscapes in van der Waals heterostructures

The emerging field of twistronics, which harnesses the twist angle between two-dimensional materials, represents a promising route for the design of quantum materials, as the twist-angle-induced superlattices offer means to control topology and strong correlations. At the small twist limit, and particularly under strain, as atomic relaxation prevails, the emergent moiré superlattice encodes elusive insights into the local interlayer interaction. Here we introduce moiré metrology as a combined experiment-theory framework to probe the stacking energy landscape of bilayer structures at the 0.1 meV/atom scale, outperforming the gold-standard of quantum chemistry. Through studying the shapes of moiré domains with numerous nano-imaging techniques, and correlating with multi-scale modelling, we assess and refine first-principle models for the interlayer interaction. We document the prowess of moiré metrology for three representative twisted systems: bilayer graphene, double bilayer graphene and H-stacked MoSe 2 /WSe 2 . Moiré metrology establishes sought after experimental benchmarks for interlayer interaction, thus enabling accurate modelling of twisted multilayers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment

With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental influences on autocollimator-based angle and form metrology

Deflectometric profilometers are indispensable tools for the precision form measurement of beam-shaping optics of synchrotrons and x-ray free electron lasers. They are used in metrology labs for x-ray optics worldwide and are crucial for providing measurement accuracy dictated by the form tolerances for modern state-of-the-art x-ray optics. Deflectometric profilometers use surface slope (angle) to assess form, and they utilize commercial autocollimators for the contactless slope measurement. In this contribution, we discuss the influences of environmental parameters, such as temperature and air pressure, including their gradients, on high-accuracy metrology with autocollimators in profilometers. They can cause substantial systematic errors in form measurement, especially in the case of large and strongly curved optical surfaces of high dynamic range. Relative angle and form measuring errors of the order of 10 -4 are to be expected. We characterize environmental influences by extended theoretical and experimental investigations and derive strategies for correcting them. Additionally, we report on the possibility to minimize the contributions of some errors by the application of sophisticated experimental arrangements and methods. We aim at approaching fundamental limits in autocollimator-based slope and form metrology.

47 OTHER INSTRUMENTATION↗

Metrology Feasibility Study in Support of the National Direct-Drive Program

The 100 Gbar Laser Direct Drive (LDD) program calls for ablator capsules with no defects larger than 0.5 μm in lateral dimension and fewer than ten defects with lateral dimensions between 0.1-0.5 μm. Comparing to Laser Indirect Drive (LID) capsules, this represents >10x reduction of defect length scale and >500x reduction in defect number density. This presents major challenges to both fabrication and metrology. In this paper, we will discuss the proof-of-principle work conducted at General Atomics to identify metrology techniques suitable for 100 Gbar target characterization. We present a detailed studies of dark-field imaging, laser scatterometry, and environmental scanning electron microscopes. We identify dark-field imaging as the best approach for meeting the 100 Gbar metrology needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Need for LWR metrology standardization: the imec roughness protocol

© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: line width roughness (LWR) specifications are expected to be <2 nm in the near term, and to drop below 1 nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. We report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines [such as measurement box length >2 μm and the need to correct for scanning electron microscope (SEM) noise]. We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol - the imec roughness protocol - intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is imperative to guarantee that when talking about a critical parameter such as LWR, everyone speaks the same language, which is not currently the case.

Lorusso, Gian Francesco↗

MO-G-12A-01: Quantitative Imaging Metrology: What Should Be Assessed and How?

The first two symposia in the Quantitative Imaging Track focused on 1) the introduction of quantitative imaging (QI) challenges and opportunities, and QI efforts of agencies and organizations such as the RSNA, NCI, FDA, and NIST, and 2) the techniques, applications, and challenges of QI, with specific examples from CT, PET/CT, and MR. This third symposium in the QI Track will focus on metrology and its importance in successfully advancing the QI field. While the specific focus will be on QI, many of the concepts presented are more broadly applicable to many areas of medical physics research and applications. As such, the topics discussed should be of interest to medical physicists involved in imaging as well as therapy. The first talk of the session will focus on the introduction to metrology and why it is critically important in QI. The second talk will focus on appropriate methods for technical performance assessment. The third talk will address statistically valid methods for algorithm comparison, a common problem not only in QI but also in other areas of medical physics. The final talk in the session will address strategies for publication of results that will allow statistically valid meta-analyses, which is critical for combining results of individual studies with typically small sample sizes in a manner that can best inform decisions and advance the field. Learning Objectives: Understand the importance of metrology in the QI efforts. Understand appropriate methods for technical performance assessment. Understand methods for comparing algorithms with or without reference data (i.e., “ground truth”). Understand the challenges and importance of reporting results in a manner that allows for statistically valid meta-analyses.

60 APPLIED LIFE SCIENCES↗

Ground Truth for CSP Mirror Metrology (Full-Length)

The high optical accuracy required for concentrating solar power (CSP) systems in turn requires accurate metrology to assess mirror optical parameters during design, manufacturing, and operation. To meet this need, researchers have developed a variety of CSP optical metrology systems, which include complex calculations and calibration terms. This raises the question: How do we know these methods’ accuracy? One approach is to compare metrology system measurements against a ground truth reference.

14 SOLAR ENERGY↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗

STANDING WAVE PROBES FOR DIMENSIONAL METROLOGY OF LOW DENSITY FOAMS

Typically, parts and geometries of interest to LLNL are made from a combination of complex geometries and a wide array of different materials ranging from metals and ceramics to low density foams and plastic foils. These parts are combined to develop physics experiments for studying material properties, equation of state (EOS) and radiation transport. Understanding the dimensional uncertainty of the parts contained within an experiment is critical to the physical understanding of the phenomena being observed and represents the motivation for developing probe metrology capability that can address LLNL's unique problems. Standing wave probes were developed for measuring high aspect ratio, micrometer scaled features with nanometer resolution. Originally conceived of for the use in the automotive industry for characterizing fuel injector bores and similar geometries, this concept was investigated and improved for use on geometries and materials important to LLNL needs within target fabrication. As part of the original project, detailed understanding of the probe dynamics and interactions with the surface of the sample was investigated. In addition, the upgraded system was utilized for measuring fuel injector bores and micro-lenses as a means of demonstrating capability. This report discusses the use of the standing wave probe for measuring features in low density foams, 55 mg/cc SiO{sub 2} and 982 mg/cc (%6 relative density) copper foam respectively. These two foam materials represent a difficult metrology challenge because of their material properties and surface topography. Traditional non-contact metrology systems such as normal incident interferometry and/or confocal microscopy have difficulty obtaining a signal from the relatively absorptive characteristics of these materials. In addition to the foam samples, a solid copper and plastic (Rexolite{trademark}) sample of similar geometry was measured with the standing wave probe as a reference for both conductive and dielectric materials.

42 ENGINEERING↗

NASA metrology information system: A NEMS subsystem

the NASA Metrology Information Systems (NMIS) is being developed as a standardized tool in managing the NASA field Center's instrument calibration programs. This system, as defined by the NASA Metrology and Calibration Workshop, will function as a subsystem of the newly developed NASA Equipment Management System (NEMS). The Metrology Information System is designed to utilize and update applicable NEMS data fields for controlled property and to function as a stand alone system for noncontrolled property. The NMIS provides automatic instrument calibration recall control, instrument historical performance data storage and analysis, calibration and repair labor and parts cost data, and instrument user and location data. Nineteen standardized reports were developed to analyze calibration system operations.

German, E. S., Jr.↗

Earthquakes and sea level - Space and terrestrial metrology on a changing planet

A review is presented of the stability and scale of crustal deformation metrology which has particular relevance to monitoring deformation associated with sea level and earthquakes. Developments in space geodesy and crustal deformation metrology in the last two decades have the potential to acquire a homogeneous global data set for monitoring relative horizontal and vertical motions of the earth's surface to within several millimeters. New tools discussed for forecasting sea level rise and damaging earthquakes include: very long baseline interferometry, satellite laser ranging, the principles of GPS geodesy, and new sea level sensors. Space geodesy permits a unified global basis for future metrology of the earth, and the continued availability of the GPS is currently fundamental to this unification.

Bilham, Roger↗

Investigations into mirror fabrication metrology analysis

This final report describes the work performed under this delivery order from June 1993 through August 1994. The scope of work included three distinct tasks in support of the AXAF-I program. The objective of the first task was to perform investigations of the grinding and polishing characteristics of the zerodur material by fabricating several samples. The second task was to continue the development of the integrated optical performance modeling software for AXAF-I. The purpose of third and final task was to develop and update the database of AXAF technical documents for an easy and rapid access. The MSFC optical and metrology shops were relocated from the B-wing of Building 4487 to Room BC 144 of Building 4466 in the beginning of this contract. This included dismantling, packing, and moving the equipment from its old location, and then reassembling it at the new location. A total of 65 zerodur samples, measuring 1 inch x 2 inches x 6 inches were ground and polished to a surface figure of lambda/10 p-v, and a surface finish of 5A rms were fabricated for coating tests. A number of special purpose tools and metal mirrors were also fabricated to support various AXAF-I development activities. In the metrology area, the ZYGO Mark 4 interferometer was relocated and also upgraded with a faster and more powerful processor. Surface metrology work was also performed on the coating samples and other optics using ZYGO interferometer and WYKO profilometer. A number of new features have been added to the GRAZTRACE program to enhance its analysis and modeling capabilities. A number of new commands have been added to the command mode GRAZTRACE program to provide a better control to the user on the program execution and data manipulation. Some commands and parameter entries have been reorganized for a uniform format. The command mode version of the convolution program CONVOLVE has been developed. An on-line help system and a user's manual have also been developed for the benefit of the users. The database of AXAF technical documents continues to progress. The titles, company name, date, and location of over 390 documents have been entered in this database. This database provides both a data search and retrieval function, and a data adding function. These functions allow a user to quickly search the data files for documents or add new information. A detailed user's guide has also been prepared. This user guide includes a document classification guide, a list of abbreviations, and a list of acronyms, which have been used in compiling this database of AXAF-I technical documents.

Dimmock, John O.↗