Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MENTAL PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Attention in aviation

The relevance of four principles or mechanisms of human attention to the design of aviation systems and the performance of pilots in multitask environments, including workload prediction and measurement, control-display integration, and the use of voice and head-up displays is discussed. The principles are: the mental energy that supplies task performance (resources), the resulting cross-talk between tasks as they are made more similar (confusion), the combination of different task elements (integration), and the way in which one task is processed and another is ignored (selection or tunneling). The introduction of greater levels of complexity into the validation of attentional theories in order to approach the demands of the cockpit or ATC console is proposed.

Wickens, Christopher D.↗

Physiological and Cognitive Factors Related to Human Performance During the Grand Canyon Rim-to-Rim Hike

Exposure to extreme environments is both mentally and physically taxing, leading to suboptimal performance and even life-threatening emergencies. Physiological and cognitive monitoring could provide the earliest indicator of performance decline and inform appropriate therapeutic intervention, yet little research has explored the relationship between these markers in strenuous settings. The Rim-to-Rim Wearables at the Canyon for Health (R2RWATCH) study is a research project at Sandia National Laboratories funded by the Defense Threat Reduction Agency to identify which physiological and cognitive phenomena collected by non-invasive wearable devices are the most related to performance in extreme environments. In a pilot study, data were collected from civilians and military warfighters hiking the Rim-to-Rim trail at the Grand Canyon. Each participant wore a set of devices collecting physiological, cognitive, and environmental data such as heart rate, memory, ambient temperature, etc. Promising preliminary results found correlates between physiological markers recorded by the wearable devices and decline in cognitive abilities, although further work is required to refine those measurements. Planned follow-up studies will validate these findings and further explore outstanding questions.

60 APPLIED LIFE SCIENCES↗

Development of microcomputer-based mental acuity tests for repeated-measures studies

The purpose of this report is to detail the development of the Automated Performance Test System (APTS), a computer battery of mental acuity tests that can be used to assess human performance in the presence of toxic elements and environmental stressors. There were four objectives in the development of APTS. First, the technical requirements for developing APTS followed the tenets of the classical theory of mental tests which requires that tests meet set criteria like stability and reliability (the lack of which constitutes insensitivity). To be employed in the study of the exotic conditions of protracted space flight, a battery with multiple parallel forms is required. The second criteria was for the battery to have factorial multidimensionality and the third was for the battery to be sensitive to factors known to compromise performance. A fourth objective was for the tests to converge on the abilities entailed in mission specialist tasks. A series of studies is reported in which candidate APTS tests were subjected to an examination of their psychometric properties for repeated-measures testing. From this work, tests were selected that possessed the requisite metric properties of stability, reliability, and factor richness. In addition, studies are reported which demonstrate the predictive validity of the tests to holistic measures of intelligence.

Kennedy, R. S.↗

Performance Monitoring Program: Developing Comparative Metrics for Fitness-for-Duty Programs

To comply with U.S. Nuclear Regulatory Commission (NRC) regulations, licensees and entities authorized under Title 10 of the Code of Federal Regulations (CFR) Part 26 Section 26.3 (§ 26.3) are required to have fitness-for-duty (FFD) programs. Under § 26.3, the expectation of these FFD programs is to provide reasonable assurance that individuals who are granted unescorted access to nuclear power reactor protected areas and Category I fuel cycle facility material control areas are trustworthy, will perform their tasks in a reliable manner, are not under the influence of any substance, legal or illegal, that may impair their ability to perform their duties, and are not mentally or physically impaired from any cause that can adversely affect their ability to safely and competently perform their duties. Pacific Northwest National Laboratory (PNNL) was tasked with developing a performance monitoring program to risk inform NRC inspection and policy regarding quantitative FFD performance data. To meet this need, PNNL developed methodologies that could be implemented within a performance monitoring program. Throughout this report, these methodologies are referred to as comparative metrics. The NRC provided PNNL with 2016–2019 data from annual reporting forms and single positive test forms provided by licensees and other entities. For most of the comparative metrics, the analyses required customized processing, such as creating filtering fields, adding data fields and summaries, and joining datasets. The comparative metrics developed include: random testing rate, random policy violation rate, pre-access policy violation rate, subversion attempt rate, and number of policy violations by labor category. The comparative metrics can be used for parsing and visualizing FFD program data and monitoring FFD performance at the labor category, facility, licensee, and industry levels to risk inform NRC inspection and policy with regard to the FFD data currently collected from licensees and other entities that implement Part 26 requirements. Furthermore, these developed comparative metrics allow a more in-depth look at the FFD programs for the industry to discern trends and patterns that may warrant changes at an industry level and to inform policy decisions. These analyses should be refreshed as new FFD data become available.

99 GENERAL AND MISCELLANEOUS↗

Real-Time Control of Diesel Combustion Quality

Detroit Diesel Corporation (DDC) and ORNL established this CRADA to improve heavy-duty engine efficiency with reduced emissions at relatively extreme operating regimes such has high EGR, low-load, and cold-start, with an emphasis on the application of advanced control strategies. The approach used in this collaborative effort was to include the application of novel analysis and modeling techniques devel-oped from the application of nonlinear dynamics and chaos theory. More specifically, analytical tech-niques derived from these theories were to used to detect, characterize, and control the combustion insta-bilities that are responsible for poor combustion performance and corresponding high emissions. The foundation of this CRADA was established based on ORNL expertise on the fundamentals of ad-vanced combustion operation and experience with nonlinear dynamics and controls in combustion sys-tems. The initial plan was all data generation would be performed at DDC with an agreed upon experi-mental plan formed by both organizations. While numerous experiments were performed at DDC and the data was exchanged with ORNL researchers, the team decided to transfer an engine to ORNL to allow more flexibility and data generation opportunities. A prototype DDC Series 60 with a common rail fuel system was selected and installed at ORNL. DDC and ORNL maintained a strong collaboration throughout much of this project. Direct funding from DOE ended in 2004 and DDC continued to fund at a reduced amount through 2007. This CRADA has not been funded in more recent years but has been maintained active in anticipation of restored funding. This CRADA has led to additional collaborations between DDC and ORNL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Always look on the bright side of life: Taking a different perspective on cybersecurity performance

This presentation will introduce participants to key mental models on how to think about and understand safety from two of the leading voices in the discipline – Dr. Erik Hollnagel and Dr. Todd Conklin – and from there we ask the simple question of “how can we apply this to cybersecurity?” At the completion of this presentation attendees will be able to describe Dr. Hollnagel’s Safety-II approach and Dr. Conkiln’s definition of safety as “not the absence of accidents but the presence of effective defenses.” They will be able to explain how these ideas translate to the cybersecurity world broadly, and more specifically to operational technology cybersecurity where physical safety consequences are coupled to control system performance. Finally, participants will be able to identify how selected principles from Weick and Sutcliffe’s high reliability organization theory can help operationalize these key mental models around safety, for improved organizational cybersecurity over the long run.

99 GENERAL AND MISCELLANEOUS↗

How a new instrument affects pilot's mental workload

Display evaluation has generally been performed using reaction time experiments or subjective evaluations to determine which display is better suited for a particular application. A new testing procedure combined with two analysis techniques of scanning behavior have been used to evaluate two alternative display designs in a realistic setting. Tests were conducted in the Langley Research Center's General Aviation Simulator. The results indicated that a new bargraph type of vertical speed indicator located between the attitude indicator and the altimeter is looked at more quickly, appears to lower cognitive workload slightly, and was preferred over a conventional vertical speed indicator.

Harris, R. L., Sr.↗

Using Tests Designed to Measure Individual Sensorimotor Subsystem Perfomance to Predict Locomotor Adaptability

Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functions during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The way each individual's brain synthesizes the available visual, vestibular and somatosensory information is likely the basis for much of the variation. Identifying the presence of biases in each person's use of information available from these sensorimotor subsystems and relating it to their ability to adapt to a novel locomotor task will allow us to customize a training program designed to enhance sensorimotor adaptability. Eight tests are being used to measure sensorimotor subsystem performance. Three of these use measures of body sway to characterize balance during varying sensorimotor challenges. The effect of vision is assessed by repeating conditions with eyes open and eyes closed. Standing on foam, or on a support surface that pitches to maintain a constant ankle angle provide somatosensory challenges. Information from the vestibular system is isolated when vision is removed and the support surface is compromised, and it is challenged when the tasks are done while the head is in motion. The integration and dominance of visual information is assessed in three additional tests. The Rod & Frame Test measures the degree to which a subject's perception of the visual vertical is affected by the orientation of a tilted frame in the periphery. Locomotor visual dependence is determined by assessing how much an oscillating virtual visual world affects a treadmill-walking subject. In the third of the visual manipulation tests, subjects walk an obstacle course while wearing up-down reversing prisms. The two remaining tests include direct measures of knee and ankle proprioception and a functional movement assessment that screens for movement restrictions and asymmetries. To assess each subject's locomotor adaptability subjects walk for twenty minutes on a treadmill that oscillates laterally at 0.3 Hz. Throughout the test metabolic cost provides a measure of exertion and step frequency provides a measure of stability. Additionally, at four points during the perturbation period, reaction time tests are used to probe changes in the amount of mental effort being used to perform the task. As with the adaptive capability observed in astronauts during gravitational transitions, our data shows significant variability between subjects. To aid in the analysis of the results, custom software tools have been developed to enhance in the visualization of the large number of output variables. Preliminary analyses of the data collected to date do not show a strong relationship between adaptability and any single predictor variable. Analysis continues to identify a multifactorial predictor outcome "signature" that do inform us of locomotor adaptability.

Peters, B. T.↗

2023 Artemis Crew Health and Performance System Model Development

While the NASA Human Research Program (HRP) utilizes a Crew Health and Performance (CHP) System to represent all the Agency’s efforts to ensure the health and performance of NASA astronauts, there is no shared mental model of a CHP system at NASA. Some groups may consider a CHP system to be only a medical kit, while others may not be using the concept at all. To facilitate the integration of functions and capabilities to ensure astronaut health and performance during vehicle development, HRP has proposed a CHP Shared Mental Model derived from the NASA Human Health, Medical, and Performance Spaceflight Standards (NASA-STD-3001 Vol.1/Vol.2). [1] Even though many vehicle, ground, and communication systems as well as mission operations are modeled for the Artemis Campaigns, no mission level CHP system model was created to achieve the intent of the HRP CHP Shared Mental Model. The lack of this model renders it difficult to visualize and understand how the many programs work together to provide the necessary cross program functions and capabilities to ensure the health and performance of the crew throughout an Artemis mission. For this purpose, the Exploration Medical Capability (ExMC) element of HRP developed a CHP system model for the Artemis III and IV missions to provide a view of how each program contributes to and interacts with the overall CHP system. To develop the 2023 Artemis CHP system model, ExMC leveraged existing data and models from the Moon to Mars Program Office, the Office of the Chief Health and Medical Officer (OCHMO) and the Orion, Gateway, Extravehicular Activity and Human Surface Mobility (EHP) and Human Landing System (HLS) programs. By using a Model-Based Systems Engineering (MBSE) approach, existing requirements, functions, and concepts of operations were combined to create a single system model focused on representing CHP from the launch to the return to Earth segments of the Artemis III and IV missions. Additionally, by incorporating the HRP Systems Platform for Aggregating and Relating Capabilities, or SPARC tool, the data from the programs was also related back to the 2nd volume of the NASA Human Health, Medical, and Performance Spaceflight Standard (NASA-STD-3001, Vol.2) and the human system risks identified by the Human System Risk Board (HSRB). The first version of the 2023 Artemis CHP system model was baselined in Fall of 2023 after the model was demonstrated to be a potentially useful tool for systems engineers integrating CHP capabilities in vehicle development as well as members of the Health and Medical Technical Authority providing oversight of those programs. The model may also be useful to any stakeholder of astronaut health and performance by providing insights on how an Artemis mission satisfies the NASA Human Health, Medical, and Performance Spaceflight Standards as well as how they mitigate the HSRB Human System Risks. This presentation highlights how the model was developed and the possible benefits of the model. [1] NASA HRP (2022), Crew Health and Performance System Whitepaper

Systems engineering↗

2023 Artemis Crew Health and Performance (CHP) System Model Development

While the NASA Human Research Program (HRP) utilizes a Crew Health and Performance (CHP) System to represent all the Agency’s efforts to ensure the health and performance of NASA astronauts, there is no shared mental model of a CHP system at NASA. Some groups may consider a CHP system to be only a medical kit, while others may not be using the concept at all. To facilitate the integration of functions and capabilities to ensure astronaut health and performance during vehicle development, HRP has proposed a CHP Shared Mental Model derived from the NASA Human Health, Medical, and Performance Spaceflight Standards (NASA-STD-3001 Vol.1/Vol.2). [1] Even though many vehicle, ground, and communication systems as well as mission operations are modeled for the Artemis Campaigns, no mission level CHP system model was created to achieve the intent of the HRP CHP Shared Mental Model. The lack of this model renders it difficult to visualize and understand how the many programs work together to provide the necessary cross program functions and capabilities to ensure the health and performance of the crew throughout an Artemis mission. For this purpose, the Exploration Medical Capability (ExMC) element of HRP developed a CHP system model for the Artemis III and IV missions to provide a view of how each program contributes to and interacts with the overall CHP system. To develop the 2023 Artemis CHP system model, ExMC leveraged existing data and models from the Moon to Mars Program Office, the Office of the Chief Health and Medical Officer (OCHMO) and the Orion, Gateway, Extravehicular Activity and Human Surface Mobility (EHP) and Human Landing System (HLS) programs. By using a Model-Based Systems Engineering (MBSE) approach, existing requirements, functions, and concepts of operations were combined to create a single system model focused on representing CHP from the launch to the return to Earth segments of the Artemis III and IV missions. Additionally, by incorporating the HRP Systems Platform for Aggregating and Relating Capabilities, or SPARC tool, the data from the programs was also related back to the 2nd volume of the NASA Human Health, Medical, and Performance Spaceflight Standard (NASA-STD-3001, Vol.2) and the human system risks identified by the Human System Risk Board (HSRB). The first version of the 2023 Artemis CHP system model was baselined in Fall of 2023 after the model was demonstrated to be a potentially useful tool for systems engineers integrating CHP capabilities in vehicle development as well as members of the Health and Medical Technical Authority providing oversight of those programs. The model may also be useful to any stakeholder of astronaut health and performance by providing insights on how an Artemis mission satisfies the NASA Human Health, Medical, and Performance Spaceflight Standards as well as how they mitigate the HSRB Human System Risks. This presentation highlights how the model was developed and the possible benefits of the model. [1] NASA HRP (2022), Crew Health and Performance System Whitepaper

Systems engineering↗

Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidence of Brain Atrophy and Decline in Mini-Mental State Examination Score After Whole-Brain Radiotherapy in Patients With Brain Metastases: A Prospective Study

Purpose: To determine the incidence of brain atrophy and dementia after whole-brain radiotherapy (WBRT) in patients with brain metastases not undergoing surgery. Methods and Materials: Eligible patients underwent WBRT to 40 Gy in 20 fractions with or without a 10-Gy boost. Brain magnetic resonance imaging or computed tomography and Mini-Mental State Examination (MMSE) were performed before and soon after radiotherapy, every 3 months for 18 months, and every 6 months thereafter. Brain atrophy was evaluated by change in cerebrospinal fluid-cranial ratio (CCR), and the atrophy index was defined as postradiation CCR divided by preradiation CCR. Results: Of 101 patients (median age, 62 years) entering the study, 92 completed WBRT, and 45, 25, and 10 patients were assessable at 6, 12, and 18 months, respectively. Mean atrophy index was 1.24 {+-} 0.39 (SD) at 6 months and 1.32 {+-} 0.40 at 12 months, and 18% and 28% of the patients had an increase in the atrophy index by 30% or greater, respectively. No apparent decrease in mean MMSE score was observed after WBRT. Individually, MMSE scores decreased by four or more points in 11% at 6 months, 12% at 12 months, and 0% at 18 months. However, about half the decrease in MMSE scores was associated with a decrease in performance status caused by systemic disease progression. Conclusions: Brain atrophy developed in up to 30% of patients, but it was not necessarily accompanied by MMSE score decrease. Dementia after WBRT unaccompanied by tumor recurrence was infrequent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Three Types of Computer-Based Procedures: An Experiment Using the Rancor Microworld Simulator

The nuclear power industry has historically used paper-based procedures, but a shift towards computer-based procedures (CBPs) has the potential to reduce human errors, alleviate mental workload, and improve work performance. Twenty-seven participants were randomly assigned to one of three CBP types using the Rancor Microworld Simulator, and each performed two different types of operational scenarios (startup and loss of feedwater). The three CBP types varied in levels of digitalization. It was hypothesized that there would be less favorable impressions of the most basic procedures, and that these would demonstrate lower usability than types with greater digitalization. Overall, our predictions were partially supported with some interesting caveats, specifically with some performance benefits for CBPs that provided indicators but not embedded controls. We discuss our findings in terms of optimal levels of digitalization/automation within nuclear operations and suggest pathways for future directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrete time modeling of heavy transport plane pilot behavior

The desire to improve flight safety leads to a classification of various flight troubles in three groups: (1) troubles from sensitivity to flight disturbances, (2) maneuverability troubles (whenever a correction maneuver induces an unexpected deviation on another parameter), and (3) pilot troubles (pilot overload when required attention is excessive or underload entailing a loss of vigilance). Sensitivity to disturbances and maneuverability of a given aircraft may be evaluated from the early design stage. Evaluation of the pilot behavior, however, may be realized only in actual flight or with a flight simulator, that is quite late in the development period. For this reason, it is desirable to have available, at the design stage, a model of the pilot behavior to command the differential system describing the envisioned aircraft. This aim implies two major requirements. First, the program must be compatible with a wide range of possible aircraft designs; ideally, the program should be self-learning. Second, mental load and overall pilot performance must be modeled.

Cavalli, D.↗

Effect of vergence on the gain of the linear vestibulo-ocular reflex

We measured the linear vestibulo-ocular reflex (LVOR) and vergence, using binocular search coils, in 3 humans. The subjects were accelerated sinusoidally at 0.5 Hz and 0.2 g peak acceleration, in complete darkness, while performing three different tasks: i) mental arithmetic; ii) tracking a remembered target at either 0.34 m or 0.14 m distance; and iii) maintaining vergence at either of these distances by means of audio biofeedback based on vergence. Subjects could control vergence using the audio feedback; there was greater convergence with the near audio target. However, there was no significant difference in vergence between the near and far remembered target conditions. With audio feedback, the amplitude of smooth tracking was not consistently different for the near and the far conditions. However, the amplitude of tracking (saccades and smooth component) in the remembered target conditions was greater for near than for far targets. These results suggest that linear VOR amplitude is not determined by vergence alone.

NASA Program Space Physiology and Countermeasures↗

Effects of Acute Exposures to Carbon Dioxide Upon Cognitive Functions

Large quantities of carbon dioxide (CO2) originate from human metabolism and typically, within spacecraft, remain about 10-fold higher in concentration than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the International Space Station (ISS) that associates CO2 levels with reports of headaches by crewmembers. Additionally, there is concern that CO2 may contribute to vision impairment and intracranial pressure that has been observed in some crewmembers. Consequently, flight rules have been employed to control the level of CO2 below 4 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. However, the flight rule imposed limit, which places additional demands upon resources and current technology, still exceeds the lower bound of the threshold range for reportable headaches (2 - 5 mm Hg). Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached. The causes of the headaches may elicit other subtle adverse effects that occur at CO2 levels well below that for headaches. The concern that CO2 may have effects at levels below the threshold for headaches appears to be substantiated in unexpected findings that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. If findings of the earlier study are confirmed in crew-like subjects, our findings would provide additional evidence that CO2 may need to be controlled at levels that are well below current spacecraft limits. Our study will extend the earlier study to determine if crew-like subjects are similarly effected by CO2. In addition to employing the Strategic Management Simulation tool, we will use the Cognition battery of psychometric measures that are being utilized aboard the ISS. It will be important to learn, by using Cognition, if additional cognitive domains are sensitive to concentrations of CO2 at or below limits currently controlled by flight rules. While spaceflight Cognition data will greatly enhance the knowledge base related to inflight behavioral health and performance, some of the measures may be influenced by fatigue (related to sleep deprivation and or workload) and changes in circadian rhythms. Therefore our use of this battery of tests in a well-controlled, ground-based study that is free of these potential confounding influences will establish a baseline terrestrial data set against which Cognition data collected in flight may be assessed. The findings from this study will be useful to the NASA Toxicology Office and the National Research Council Committee on Toxicology, which assists NASA in setting environmental standards, for revision of the SMAC for CO2, and for designing further studies on effects of CO2 upon cognitive functions.

Scully, R. R.↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Comparing viewer and array mental rotations in different planes

Participants imagined rotating either themselves or an array of objects that surrounded them. Their task was to report on the egocentric position of an item in the array following the imagined rotation. The dependent measures were response latency and number of errors committed. Past research has shown that self-rotation is easier than array rotation. However, we found that imagined egocentric rotations were as difficult to imagine as rotations of the environment when people performed imagined rotations in the midsagittal or coronal plane. The advantages of imagined self-rotations are specific to mental rotations performed in the transverse plane.

NASA Center ARC↗