Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNPX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

DHS Summary Report -- Robert Weldon

This summer I worked on benchmarking the Lawrence Livermore National Laboratory fission multiplicity capability used in the Monte Carlo particle transport code MCNPX. This work involved running simulations and then comparing the simulation results with experimental experiments. Outlined in this paper is a brief description of the work completed this summer, skills and knowledge gained, and how the internship has impacted my planning for the future. Neutron multiplicity counting is a neutron detection technique that leverages the multiplicity emissions of neutrons from fission to identify various actinides in a lump of material. The identification of individual actinides in lumps of material crossing our boarders, especially U-235 and Pu-239, is a key component for maintaining the safety of the country from nuclear threats. Several multiplicity emission options from spontaneous and induced fission already existed in MCNPX 2.4.0. These options can be accessed through use of the 6th entry on the PHYS:N card. Lawrence Livermore National Laboratory (LLNL) developed a physics model for the simulation of neutron and gamma ray emission from fission and photofission that was included in MCNPX 2.7.B as an undocumented feature and then was documented in MCNPX 2.7.C. The LLNL multiplicity capability provided a different means for MCNPX to simulate neutron and gamma-ray distributions for neutron induced, spontaneous and photonuclear fission reactions. The original testing on the model for implementation into MCNPX was conducted by Gregg McKinney and John Hendricks. The model is an encapsulation of measured data of neutron multiplicity distributions from Gwin, Spencer, and Ingle, along with the data from Zucker and Holden. One of the founding principles of MCNPX was that it would have several redundant capabilities, providing the means of testing and including various physics packages. Though several multiplicity sampling methodologies already existed within MCNPX, the LLNL fission multiplicity was included to provide a separate capability for computing multiplicity as well as including several new features not already included in MCNPX. These new features include: (1) prompt gamma emission/multiplicity from neutron-induced fission; (2) neutron multiplicity and gamma emission/multiplicity from photofission; and (3) an option to enforce energy correlation for gamma neutron multiplicity emission. These new capabilities allow correlated signal detection for identifying presence of special nuclear material (SNM). Therefore, these new capabilities help meet the missions of the Domestic Nuclear Detection Office (DNDO), which is tasked with developing nuclear detection strategies for identifying potential radiological and nuclear threats, by providing new simulation capability for detection strategies that leverage the new available physics in the LLNL multiplicity capability. Two types of tests were accomplished this summer to test the default LLNL neutron multiplicity capability: neutron-induced fission tests and spontaneous fission tests. Both cases set the 6th entry on the PHYS:N card to 5 (i.e. use LLNL multiplicity). The neutron-induced fission tests utilized a simple 0.001 cm radius sphere where 0.0253 eV neutrons were released at the sphere center. Neutrons were forced to immediately collide in the sphere and release all progeny from the sphere, without further collision, using the LCA card, LCA 7j -2 (therefore density and size of the sphere were irrelevant). Enough particles were run to ensure that the average error of any specific multiplicity did not exceed 0.36%. Neutron-induced fission multiplicities were computed for U-233, U-235, Pu-239, and Pu-241. The spontaneous fission tests also used the same spherical geometry, except: (1) the LCA card was removed; (2) the density of the sphere was set to 0.001 g/cm3; and (3) instead of emitting a thermal neutron, the PAR keyword was set to PAR=SF. The purpose of the small density was to ensure that the spontaneous fission neutrons would not further interact and induce fissions (i.e. the mean free path greatly exceeded the size of the sphere). Enough particles were run to ensure that the average error of any specific spontaneous multiplicity did not exceed 0.23%. Spontaneous fission multiplicities were computed for U-238, Pu-238, Pu-240, Pu-242, Cm-242, and Cm-244. All of the computed results were compared against experimental results compiled by Holden at Brookhaven National Laboratory.

42 ENGINEERING↗

SU-F-19A-04: Dosimetric Evaluation of a Novel CT/MR Compatible Fletcher Applicator for Intracavitary Brachytherapy of the Cervix Uteri

Purpose: To validate a Monte Carlo model and evaluate the dosimetric capabilities of a novel commercial CT/MR compatible Fletcher applicator for cervical cancer brachytherapy. Methods: MCNPX 2.7.0 was used to model the Fletcher CT/MR shielded applicator (FA) and 192Ir HDR source. Energy deposition was calculated with a track length estimator modified by an energy-dependent heating function. A high density polystyrene phantom was constructed with three film pockets for validation of the MCNPX model. Three planes of data were calculated with the MCNPX model corresponding to the three film planes in phantom. The planes were located 1 cm from the most anterior, posterior, and medial extents of the FA right ovoid. Unshielded distributions were calculated by modeling the shielded cells as air instead of the tungsten alloy. A third order polynomial fit to the OD to dose curve was used to convert OD of the three film planes to dose. Each film and MCNPX plane dose distribution was normalized to a point 2 cm from the center of the film plane and in a region of low dose gradient. MCNPX and film were overlaid and compared with a distance-to-agreement criterion of (±2%/±2mm). Shielded and unshielded distributions were overlaid and a percent shielded plot was created. Results: 85.2%, 97.1%, and 96.6% of the MCNPX points passed the (±2%/±2mm) criterion respectively for the anterior, lateral, and posterior film comparison planes. A majority of the points in the anterior plane that exceeded the DTA criterion were either along edges of where the film was cut or near the terminal edges of the film. The percent shielded matrices indicated that the maximum % shielding was 50%. Conclusion: These data confirm the validity of the FA Monte Carlo model. The FA ovoid can shield up to 50% of the dose in the anteroposterior direction.

60 APPLIED LIFE SCIENCES↗

MCNPX270 LLNL Fission Model

The LLNL fission model is an available option in MCNPX version 2.7.0. It was developed at Lawrence Livermore National Laboratory and we have collaborated to implement it in MCNPX. We report here our observations and assessments of the LLNL fission model in MCNPX relative to alternative treatments in MCNPX. The LLNL fission model is the only way for MCNPX to produce correlated prompt gammas from prompt fission, delayed fission, spontaneous fission, and photofission. The LLNL fission model also produces fission neutrons and gammas with the correct multiplicities for induced fission, spontaneous fission, and photofission. The exact modeling of the neutron- and photon-induced fission process enables coincidence counting of fission neutrons and gammas. Comparisons were made to the MCNPX default fission capability which uses ACE table physics and the default fmult fission multiplicity capability. Also, several corrections were made in MCNPX27E and these are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nondestructive Spent Fuel Assay Using Nuclear Resonance Fluorescence

Quantifying the isotopic composition of spent fuel is an important challenge and essential for many nuclear safeguards applications, such as independent verification of the Pu content declared by a regulated facility, shipper/receiver measurements, and quantifying isotopic input masses at a reprocessing facility. As part of the Next Generation Safeguards Initiative, NA-241 has recently funded a multilab/university collaboration to investigate a variety of nondestructive methods for determining the elemental Pu mass in spent fuel assemblies. Nuclear resonance fluorescence (NRF) is one of the methods being investigated. First modeling studies have been performed to investigate the feasibility of assaying a single fuel pin using a bremsstrahlung photon source. MCNPX modeling results indicate that NRF signals are significantly more intense than the background due to scattered interrogation photons even for isotopes with concentrations below 1percent. However, the studies revealed that the dominant contribution to the background is elastic scattering, which is currently not simulated by MCNPX. Critical to this effort, we have added existing NRF data to the MCNPX photonuclear data files and are now able to incorporate NRF physics into MCNPX simulations. Addition of the non-resonant elastic scattering data to MCNPX is in progress. Assaying fuel assemblies with NRF poses additional challenges: photon penetration through the assembly is small and the spent fuel radioactive decay and neutron activity lead to significantly higher backgrounds. First modeling studies to evaluate the efficacy of NRF for assaying assemblies have been initiated using the spent fuel assembly library created at the Los Alamos National Laboratory (LANL).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-E-T-212: Comparison of TG-43 Dosimetric Parameters of Low and High Energy Brachytherapy Sources Obtained by MCNP Code Versions of 4C, X and 5

Purpose: Different versions of MCNP code are widely used for dosimetry purposes. The purpose of this study is to compare different versions of the MCNP codes in dosimetric evaluation of different brachytherapy sources. Methods: The TG-43 parameters such as dose rate constant, radial dose function, and anisotropy function of different brachytherapy sources, i.e. Pd-103, I-125, Ir-192, and Cs-137 were calculated in water phantom. The results obtained by three versions of Monte Carlo codes (MCNP4C, MCNPX, MCNP5) were compared for low and high energy brachytherapy sources. Then the cross section library of MCNP4C code was changed to ENDF/B-VI release 8 which is used in MCNP5 and MCNPX codes. Finally, the TG-43 parameters obtained using the MCNP4C-revised code, were compared with other codes. Results: The results of these investigations indicate that for high energy sources, the differences in TG-43 parameters between the codes are less than 1% for Ir-192 and less than 0.5% for Cs-137. However for low energy sources like I-125 and Pd-103, large discrepancies are observed in the g(r) values obtained by MCNP4C and the two other codes. The differences between g(r) values calculated using MCNP4C and MCNP5 at the distance of 6cm were found to be about 17% and 28% for I-125 and Pd-103 respectively. The results obtained with MCNP4C-revised and MCNPX were similar. However, the maximum difference between the results obtained with the MCNP5 and MCNP4C-revised codes was 2% at 6cm. Conclusion: The results indicate that using MCNP4C code for dosimetry of low energy brachytherapy sources can cause large errors in the results. Therefore it is recommended not to use this code for low energy sources, unless its cross section library is changed. Since the results obtained with MCNP4C-revised and MCNPX were similar, it is concluded that the difference between MCNP4C and MCNPX is their cross section libraries.

60 APPLIED LIFE SCIENCES↗

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

The Next Generation Safeguard Initiative (NGSI) of the U.S Department of Energy is supporting a multi-lab/university collaboration to quantify the plutonium (Pu) mass in spent nuclear fuel (SNF) assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. The following 14 NDA techniques are being studied: Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Lead Slowing Down Spectrometer, Neutron Multiplicity, Passive Neutron Albedo Reactivity, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Gamma, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Self-integration Neutron Resonance Densitometry, and Neutron Resonance Transmission Analysis. Understanding and maturity of the techniques vary greatly, ranging from decades old, well-understood methods to new approaches. Nuclear Resonance Fluorescence (NRF) is a technique that had not previously been studied for SNF assay or similar applications. Since NRF generates isotope-specific signals, the promise and appeal of the technique lies in its potential to directly measure the amount of a specific isotope in an SNF assay target. The objectives of this study were to design and model suitable NRF measurement methods, to quantify capabilities and corresponding instrumentation requirements, and to evaluate prospects and the potential of NRF for SNF assay. The main challenge of the technique is to achieve the sensitivity and precision, i.e., to accumulate sufficient counting statistics, required for quantifying the mass of Pu isotopes in SNF assemblies. Systematic errors, considered a lesser problem for a direct measurement and only briefly discussed in this report, need to be evaluated for specific instrument designs in the future. Also, since the technical capability of using NRF to measure Pu in SNF has not been established, this report does not directly address issues such as cost, size, development time, nor concerns related to the use of Pu in measurement systems. This report discusses basic NRF measurement concepts, i.e., backscatter and transmission methods, and photon source and {gamma}-ray detector options in Section 2. An analytical model for calculating NRF signal strengths is presented in Section 3 together with enhancements to the MCNPX code and descriptions of modeling techniques that were drawn upon in the following sections. Making extensive use of the model and MCNPX simulations, the capabilities of the backscatter and transmission methods based on bremsstrahlung or quasi-monoenergetic photon sources were analyzed as described in Sections 4 and 5. A recent transmission experiment is reported on in Appendix A. While this experiment was not directly part of this project, its results provide an important reference point for our analytical estimates and MCNPX simulations. Used fuel radioactivity calculations, the enhancements to the MCNPX code, and details of the MCNPX simulations are documented in the other appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculation and verification of the geometrical factors for the NPDGamma experiment

The NPDGamma experiment measures the parity-violating asymmetry in gamma-ray emission in the capture of polarized neutrons on liquid parahydrogen. The sensitivity to the asymmetry for each detector in the array is used as a parameter in the extraction of the physics asymmetry from the measured data. The detector array is approximately cylindrically symmetric around the target and a step-wise sinusoidal function has been used for the sensitivity in the previous iteration of the NPDGamma experiment, but deviations from cylindrical symmetry necessitate the use of a Monte Carlo model to determine corrections to the geometrical factors. For the calculations, source code modifications to MCNPX were done in order to calculate the sensitivity of each cesium iodide detector to the physics asymmetry. We describe the MCNPX model and results from calculations and how the results are validated through measurement of the parity violating asymmetry of gamma-rays from neutron capture on chlorine.

Grammer, K. B.↗

Electron Accelerator Shielding Design of KIPT Neutron Source Facility

The Argonne National Laboratory of the United States and the Kharkov Institute of Physics and Technology of the Ukraine have been collaborating on the design, development and construction of a neutron source facility at Kharkov Institute of Physics and Technology utilizing an electron-accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100-MeV electrons. The facility was designed to perform basic and applied nuclear research, produce medical isotopes, and train nuclear specialists. The biological shield of the accelerator building was designed to reduce the biological dose to less than 5.0e-03 mSv/h during operation. The main source of the biological dose for the accelerator building is the photons and neutrons generated from different interactions of leaked electrons from the electron gun and the accelerator sections with the surrounding components and materials. The Monte Carlo N-particle extended code (MCNPX) was used for the shielding calculations because of its capability to perform electron-, photon-, and neutron-coupled transport simulations. The photon dose was tallied using the MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is very small, similar to 0.01 neutron for 100-MeV electron and even smaller for lower-energy electrons. This causes difficulties for the Monte Carlo analyses and consumes tremendous computation resources for tallying the neutron dose outside the shield boundary with an acceptable accuracy. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were utilized for this study. The generated neutrons were banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron dose. The weight windows variance reduction technique was also utilized for both neutron and photon dose calculations. Two shielding materials, heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary less than 5.0e-03 mSv/h during operation. The shield configuration and parameters of the accelerator building were determined and are presented in this paper. Copyright (C) 2016, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society.

43 PARTICLE ACCELERATORS↗

Development of output user interface software to support analysis

Data processing software packages such as VSOP and MCNPX are softwares that has been scientifically proven and complete. The result of VSOP and MCNPX are huge and complex text files. In the analyze process, user need additional processing like Microsoft Excel to show informative result. This research develop an user interface software for output of VSOP and MCNPX. VSOP program output is used to support neutronic analysis and MCNPX program output is used to support burn-up analysis. Software development using iterative development methods which allow for revision and addition of features according to user needs. Processing time with this software 500 times faster than with conventional methods using Microsoft Excel. PYTHON is used as a programming language, because Python is available for all major operating systems: Windows, Linux/Unix, OS/2, Mac, Amiga, among others. Values that support neutronic analysis are k-eff, burn-up and mass Pu{sup 239} and Pu{sup 241}. Burn-up analysis used the mass inventory values of actinide (Thorium, Plutonium, Neptunium and Uranium). Values are visualized in graphical shape to support analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TH-C-BRD-02: Analytical Modeling and Dose Calculation Method for Asymmetric Proton Pencil Beams

Purpose: A dynamic collimation system (DCS), which consists of two pairs of orthogonal trimmer blades driven by linear motors has been proposed to decrease the lateral penumbra in pencil beam scanning proton therapy. The DCS reduces lateral penumbra by intercepting the proton pencil beam near the lateral boundary of the target in the beam's eye view. The resultant trimmed pencil beams are asymmetric and laterally shifted, and therefore existing pencil beam dose calculation algorithms are not capable of trimmed beam dose calculations. This work develops a method to model and compute dose from trimmed pencil beams when using the DCS. Methods: MCNPX simulations were used to determine the dose distributions expected from various trimmer configurations using the DCS. Using these data, the lateral distribution for individual beamlets was modeled with a 2D asymmetric Gaussian function. The integral depth dose (IDD) of each configuration was also modeled by combining the IDD of an untrimmed pencil beam with a linear correction factor. The convolution of these two terms, along with the Highland approximation to account for lateral growth of the beam along the depth direction, allows a trimmed pencil beam dose distribution to be analytically generated. The algorithm was validated by computing dose for a single energy layer 5×5 cm{sup 2} treatment field, defined by the trimmers, using both the proposed method and MCNPX beamlets. Results: The Gaussian modeled asymmetric lateral profiles along the principal axes match the MCNPX data very well (R{sup 2}≥0.95 at the depth of the Bragg peak). For the 5×5 cm{sup 2} treatment plan created with both the modeled and MCNPX pencil beams, the passing rate of the 3D gamma test was 98% using a standard threshold of 3%/3 mm. Conclusion: An analytical method capable of accurately computing asymmetric pencil beam dose when using the DCS has been developed.

07 ISOTOPE AND RADIATION SOURCES↗

Status of Cross-section Data Libraries for MCNP

The Data Team, part of the XCP-5 group at LANL, uses the NJOY code and other codes to prepare the cross-section data files used by the Monte Carlo codes MCNP5, MCNPX, and MCNP6. They perform extensive quality assurance checking of those data files. The cross-section data files are included with the releases of MCNP that are distributed by RSICC. MCNP5 is developed and supported by the Monte Carlo Codes group (XCP-3) at LANL. MCNPX is developed and supported by the NEN-5 group at LANL. MCNP6 is a merger of MCNP5 and MCNPX, with numerous additional features, and is jointly developed and supported by the XCP-3 and NEN-5 groups. MCNP5 and MCNPX are "frozen" codes, and all new development is being carried out only in the MCNP6 code. In the past, when new types of data or improved representations were developed, the Data Team would incorporate the changes into the cross-section data files, and the Monte Carlo groups would make corresponding changes to the MCNP codes to use the new data. At present, however, only MCNP6 is updated to handle new data representations; MCNP5/X are not.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulations of neutron multiplicity measurements of a weapons-grade plutonium sphere with MCNP-PoliMi.

With increasing concern over the ability to detect and characterize special nuclear materials, the need for computer codes that can successfully predict the response of detector systems to various measurement scenarios is extremely important. These computer algorithms need to be benchmarked against a variety of experimental configurations to ensure their accuracy and understand their limitations. The Monte Carlo code MCNP-PoliMi is a modified version of the MCNP-4c code. Recently these modifications have been ported into the new MCNPX 2.6.0 code, which gives the new MCNPX-PoliMi a wider variety of options and abilities, taking advantage of the improvements made to MCNPX. To verify the ability of the MCNPX-PoliMi code to simulate the response of a neutron multiplicity detector simulated results were compared to experimental data. The experiment consisted of a 4.5-kg sphere of alpha-phase plutonium that was moderated with various thicknesses of polyethylene. The results showed that our code system can simulate the multiplicity distributions with relatively good agreement with measured data. The enhancements made to MCNP since the release of MCNP-4c have had little to no effect on the ability of the MCNP-PoliMi to resolve the discrepancies observed in the simulated neutron multiplicity distributions when compared experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The New MCNP6 Depletion Capability

The first MCNP based inline Monte Carlo depletion capability was officially released from the Radiation Safety Information and Computational Center as MCNPX 2.6.0. Both the MCNP5 and MCNPX codes have historically provided a successful combinatorial geometry based, continuous energy, Monte Carlo radiation transport solution for advanced reactor modeling and simulation. However, due to separate development pathways, useful simulation capabilities were dispersed between both codes and not unified in a single technology. MCNP6, the next evolution in the MCNP suite of codes, now combines the capability of both simulation tools, as well as providing new advanced technology, in a single radiation transport code. We describe here the new capabilities of the MCNP6 depletion code dating from the official RSICC release MCNPX 2.6.0, reported previously, to the now current state of MCNP6. NEA/OECD benchmark results are also reported. The MCNP6 depletion capability enhancements beyond MCNPX 2.6.0 reported here include: (1) new performance enhancing parallel architecture that implements both shared and distributed memory constructs; (2) enhanced memory management that maximizes calculation fidelity; and (3) improved burnup physics for better nuclide prediction. MCNP6 depletion enables complete, relatively easy-to-use depletion calculations in a single Monte Carlo code. The enhancements described here help provide a powerful capability as well as dictate a path forward for future development to improve the usefulness of the technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Evaluation of Monte Carlo Simulations of Neutron Multiplicity Measurements of Plutonium Metal

In January 2009, Sandia National Laboratories conducted neutron multiplicity measurements of a polyethylene-reflected plutonium metal sphere. Over the past 3 years, those experiments have been collaboratively analyzed using Monte Carlo simulations conducted by University of Michigan (UM), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), and North Carolina State University (NCSU). Monte Carlo simulations of the experiments consistently overpredict the mean and variance of the measured neutron multiplicity distribution. This paper presents a sensitivity study conducted to evaluate the potential sources of the observed errors. MCNPX-PoliMi simulations of plutonium neutron multiplicity measurements exhibited systematic over-prediction of the neutron multiplicity distribution. The over-prediction tended to increase with increasing multiplication. MCNPX-PoliMi had previously been validated against only very low multiplication benchmarks. We conducted sensitivity studies to try to identify the cause(s) of the simulation errors; we eliminated the potential causes we identified, except for Pu-239 {bar {nu}}. A very small change (-1.1%) in the Pu-239 {bar {nu}} dramatically improved the accuracy of the MCNPX-PoliMi simulation for all 6 measurements. This observation is consistent with the trend observed in the bias exhibited by the MCNPX-PoliMi simulations: a very small error in {bar {nu}} is 'magnified' by increasing multiplication. We applied a scalar adjustment to Pu-239 {bar {nu}} (independent of neutron energy); an adjustment that depends on energy is probably more appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Improvements To CINDER2008 and Activation Analysis Tools

CINDER2008 is a transmutation code that calculates induced radioactivity for either reactor- or accelerator-driven radiation sources. Several Perl scripts have been developed to treat multi-cell problems in combination with either the radiation transport code MCNPX or a special version of MCNPX that writes residual nuclide tallies from model-based physics directly in the MCNPX output file. These scripts simplify the preparation of CINDER input, and can use CINDER output to prepare the source term for a subsequent MCNPX run to calculate dose rates due to activated material. In addition, these scripts support calculations with the transmutation codes SP-FISPACT and ORIHET-3. A number of improvements have been made to CINDER, its data libraries, and the Perl scripts, including (1) substantial corrections to the data libraries, (2) inclusion of recent revisions to USDOE HC-2/HC-3 thresholds and the corresponding thresholds for regulatory bodies in other countries, (3) the ability to run the CINDER accident analysis tool through the script input file, and (4) an easier way to write the script input file when treating a large number of cells. Some features of running CINDER and a number of example problems are discussed.

Micklich, Bradley J.↗