Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

The neutron camera upgrade for MAST Upgrade

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252 Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. Finally, the energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

47 OTHER INSTRUMENTATION↗

Validating the simulation of beam-ion charge exchange in MAST Upgrade

Abstract Simulation of the impact of charge-exchange (CX) reactions on beam ions in the Mega Amp Spherical Tokamak (MAST) Upgrade was compared to measurements carried out with a fission chamber (neutron fluxes) and a fast ion deuterium-alpha (FIDA) diagnostic. A simple model was developed to reconstruct the outer-midplane neutral density based on measurements of deuterium-alpha emission from edge neutrals, and on Thomson scattering measurements of electron density and temperature. The main computational tools used were the ASCOT orbit-following code and the FIDASIM code for producing synthetic FIDA signals. The neutral density reconstruction agrees qualitatively with SOLPS-ITER modelling and yields a synthetic passive FIDA signal that is consistent with measurement. When CX losses of beam ions are accounted for, predicted neutron emission rates are quantitatively more consistent with measurement. It was necessary to account for CX losses of beam ions in simulations to reproduce the measured passive FIDA signal quantitatively and qualitatively. The results suggest that the neutral density reconstruction is a good approximation, that CX with edge neutrals causes significant beam-ion losses in MAST Upgrade, typically 20% of beam power, and that the ASCOT fast-ion CX model can be used to accurately predict the redistribution and loss of beam ions due to CX.

Physics↗

Perturbative momentum transport in MAST L-mode plasmas

Non-axisymmetric magnetic fields are used to perturbatively probe momentum transport physics in MAST L-mode plasmas. The low beta L-mode target was chosen to complement previous experiments conducted in high beta NSTX H-mode plasmas (beta N = 3.5-4.6) where an inward momentum pinch was measured. In those cases quasi-linear gyrokinetic simulations of unstable ballooning micro-instabilities predict weak or outward momentum convection, in contrast to the measurements. The weak pinch was predicted to be due to both electromagnetic effects at high beta and low aspect ratio minimizing the symmetry-breaking of the instabilities responsible for momentum transport. In an attempt to lessen these electromagnetic effects at low aspect ratio, perturbative experiments were run in MAST L-mode discharges at lower beta (beta N = 2). The perturbative transport analysis used the time-dependent response following the termination of applied 3D fields that briefly brake the plasma rotation ( similar to the NSTX H-mode experiments). Assuming time-invariant diffusive (chi(phi))and convective (V-phi) transport coefficients, an inward pinch is inferred with magnitudes, (RV phi/chi(phi)) = (-1)-(-9), similar to those found in NSTX H-modes and in conventional tokamaks. However, if experimental uncertainties due to non-stationary conditions during and after the applied 3D field are considered, a weak pinch or even outward convection is inferred, ( RV phi/chi(phi)) = (-1)-(+5). Linear gyrokinetic simulations indicate that for these lower beta L-modes, the predicted momentum pinch is predicted to be relatively small, ( RV phi/chi(phi))(sim) approximate to -1. While this falls within the experimentally inferred range, the uncertainties are practically too large to quantitatively validate the predictions. Challenges and implications for this particular experimental technique are discussed, as well as additional possible physical mechanisms that may be important in understanding momentum transport in these low aspect ratio plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of deuterium and carbon radiation transport in MAST-U tokamak advanced divertors

Modest effects of deuterium and carbon radiation opacity in the Super-X and snowflake divertor plasmas are predicted for MAST Upgrade tokamak with core plasma input power 2.5–5 MW and plasma current 1 MA. The radiation transport modeling is based on the SOLPS-EIRENE and UEDGE code divertor plasma predictions. Two radiation transport models are used: one is based on a full radiation transport equation implemented in the radiation transport and collisional-radiative code CRETIN (without feedback on the background plasma), and another is an internal self-consistent UEDGE model with ionization, recombination, and heating rates corrected for Ly α line trapping based on the escape probability model implemented in CRETIN. In MAST-U, the Super-X and snowflake divertor plasmas are predicted to reach detached regimes at lower upstream densities than the standard divertor, and the conclusion still holds with radiation transport effects included. At neutral densities m -3 , modest Ly α deuterium line trapping with optical depths 10–15 is predicted in the Super-X divertor. Divertor plasmas are optically thin to other Lyman and Balmer lines, as well as to strong C III and C IV lines that are responsible for most of divertor radiated power. Insignificant changes (within a few percent) to divertor deuterium ionization and recombination rates are found. Radiation fluxes on outer divertor target are modified within a factor of 2–3 when the radiation transport is accounted for, and a similar variation is found due to the line shape models that define the absorption and emission line profiles in the radiation transport modeling. The predicted Lyman and Balmer spectral intensities are significantly modified due to radiation trapping. A measurement of divertor radiation transport effects is discussed using the Ly β /Ba α line ratio. In the snowflake divertor configuration, divertor plasmas are found to be optically thin to Lyman series lines within a large range of parameter variations that include upstream density, divertor transport coefficients, and magnetic configurations. Finally, modest radiation transport effects are only found in a few cases with strongest divertor transport and magnetic configurations closest to the ideal snowflake configuration, however, the plasma background models that were used are yet to be validated with an experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Increased radiation due to non-coronal effects on DIII-D and MAST-U with varying input power

Through SOLPS-ITER simulations of DIII-D and MAST-U, an X-divertor (XD) on DIII-D and a super X-divertor (SXD) on MAST-U were shown to have increased carbon emissivity (P Rad /n e n I ) over corresponding standard divertors (SD) at similar degrees of partial detachment. The reasons behind the increased emissivity in the DIII-D XD and SXD are analyzed using a simple 0D transport model. From the transport model, it is seen that a major cause of the increased emissivity in the XD and SXD over the SDs is a shorter impurity confinement time. An additional cause (for the SXD) is an increase in the ratio of neutral hydrogen to electron density. The input power (P in ) was varied and the XD had a higher emissivity at the higher P in , unlike the SDs which had the emissivity decrease with increasing P in . A basic geometrical reason is given to explain both the benefits of the XD over the SD as well as the increase in the XD's emissivity with P in .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of fast particle experiments in the first MAST Upgrade experimental campaigns

Abstract MAST-U is equipped with on-axis and off-axis neutral beam injectors (NBI), and these external sources of super-Alfvénic deuterium fast-ions provide opportunities for studying a wide range of phenomena relevant to the physics of alpha-particles in burning plasmas. The MeV range D-D fusion product ions are also produced but are not confined. Simulations with the ASCOT code show that up to 20% of fast ions produced by NBI can be lost due to charge exchange (CX) with edge neutrals. Dedicated experiments employing low field side (LFS) gas fuelling show a significant drop in the measured neutron fluxes resulting from beam-plasma reactions, providing additional evidence of CX-induced fast-ion losses, similar to the ASCOT findings. Clear evidence of fast-ion redistribution and loss due to sawteeth (ST), fishbones (FB), long-lived modes (LLM), Toroidal Alfvén Eigenmodes (TAE), Edge Localised Modes (ELM) and neoclassical tearing modes (NTM) has been found in measurements with a Neutron Camera (NCU), a scintillator-based Fast-Ion Loss Detector (FILD), a Solid-State Neutral Particle Analyser (SSNPA) and a Fast-Ion Deuterium- α (FIDA) spectrometer. Unprecedented FILD measurements in the range of 1–2 MHz indicate that fast-ion losses can be also induced by the beam ion cyclotron resonance interaction with compressional or global Alfvén eigenmodes (CAEs or GAEs). These results show the wide variety of scenarios and the unique conditions in which fast ions can be studied in MAST-U, under conditions that are relevant for future devices like STEP or ITER.

Physics↗

First data and preliminary experimental results from a new Doppler backscattering system on the MAST-U spherical tokamak

Abstract A new Doppler backscattering (DBS) system, consisting of Q-band and V-band, has been installed and achieved its first data on the MAST-U spherical tokamak. The Q-band and V-band have separate microwave source systems, but share the same optical front-end components. The Q-band and V-band sources simultaneously generate eight (34, 36, 38, 40, 42, 44, 46 and 48 GHz) and seven (52.5, 55, 57.5, 60, 62.5, 65 and 67.5 GHz) fixed frequency probe beams, respectively. These frequencies provide a large range of radial positions from the low-field-side edge plasma to the core, and possibly to the high-field-side edge, depending on the plasma conditions. The quasi-optical system consists of a remotely-tunable polarizer, a focusing lens and a remotely-steerable mirror. By steering the mirror, the system provides remote control of the probed density fluctuation wavenumber, and allow the launch angle to match the magnetic field. The range of accessible turbulence wavenumbers (k θ ) is reasonably large with normalized wavenumberk θ ρ s ranging from <0.5 to 9. The first data acquired by this DBS system is validated by comparing with the data from the other DBS system on MAST-U (introduced in ref. [21]). An example of measuring the velocity profile spanning from the edge to the center in a high-density plasma is presented, indicating the robust capabilities of the integrated Q-band and V-band DBS systems.

Instruments & Instrumentation↗

Towards understanding edge localised mode mitigation by resonant magnetic perturbations in MAST

Type-I Edge Localised Modes (ELMs) have been mitigated in MAST through the application of n=3,4, and 6 resonant magnetic perturbations. For each toroidal mode number of the non-axisymmetric applied fields, the frequency of the ELMs has been increased significantly, and the peak heat flux on the divertor plates reduced commensurately. This increase in ELM frequency occurs despite a significant drop in the edge pressure gradient, which would be expected to stabilise the peeling-ballooning modes thought to be responsible for type-I ELMs. Various mechanisms which could cause a destabilisation of the peeling-ballooning modes are presented, including pedestal widening, plasma rotation braking, three dimensional corrugation of the plasma boundary, and the existence of radially extended lobe structures near to the X-point. This leads to a model aimed at resolving the apparent dichotomy of ELM control, which is to say ELM suppression occurring due to the pedestal pressure reduction below the peeling-ballooning stability boundary, whilst the reduction in pressure can also lead to ELM mitigation, which is ostensibly a destabilisation of peeling-ballooning modes. In the case of ELM mitigation, the pedestal broadening, 3d corrugation, or lobes near the X-point degrade ballooning stability so much that the pedestal recovers rapidly to cross the new stability boundary at lower pressure more frequently, whilst in the case of suppression, the plasma parameters are such that the particle transport reduces the edge pressure below the stability boundary, which is only mildly affected by negligible rotation braking, small edge corrugation or short, broad lobe structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Assessment of a 1-D, Multi-colour X-ray Imaging System for the MAST ST

A design of the ID soft x-ray imaging system for future experiments at the Mega-Amper Spherical Tokamak (MAST) and results of the numerical simulations based on initial assumptions about the state of the tokamak plasma as well as the parameters and geometry of the detection system are presented. The imaging system consists of a set of arrays of detectors, pinholes and filters attached to each set, together with suitable readout electronics. In simulations, an array of semiconductor detectors is compared with an array of scintillator-photomultiplier combination. The measuring system is assumed to operate in the range 1-10 keV. In addition to the 1-D imaging of x-ray emission, the system gives the possibility to measure the energy slope of x-ray spectrum and thus the electron temperature of plasma.An extended numerical code simulates the imaging system for various parameters of plasma (spatial profiles of the plasma density and temperature) generated at the tokamak and for different configurations of the detection system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron camera system for MAST

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization of Thomson scattering measurements on MAST using an FPGA based ''Smart'' trigger unit

The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam emission spectroscopy turbulence imaging system for the MAST spherical tokamak

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D{sub {alpha}} emission from the {approx}2 MW heating beam of {approx}70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 x 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of {approx}2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of {approx}10{sup 11} s{sup -1} the achieved signal-to-noise ratio of {approx}300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of neutron emission profiles in MAST with a collimated neutron monitor

A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n){sup 3}He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled. Good agreement is found between the experimental data and the simulations. Examples are given showing the sensitivity of the recoil proton pulse height spectra to different observation angles with respect the neutral beam injection and the plasma rotation direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗