Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

First experiences with the H-maser EFOS 1

The results are given on the performance measurements, on the dependence on external temperature, and on external magnetic field of a hydrogen maser. It is compared with another hydrogen maser. Details of the transportation and installation of the maser are given. The hydrogen maser frequency is compared with cesium oscillators to derive long-term behavior.

Schlueter, W.

The NASA/GSFC hydrogen maser program: A review of recent data

Data is presented on the phase and frequency stability, over time periods extending to one week, of the new NR field operable hydrogen masers developed by the Applied Physics Laboratory (APL) and the older NX and NP field operable hydrogen masers developed by Goddard Space Flight Center and maintained and upgraded by Bendix Field Engineering Corporation (BFEC). Data is presented on the NR masers in the laboratory showing frequency stabilities well into the 10 to the -15th power range and phase stabilities well into the 100 ps range for periods of up to one day. Data is presented on upgraded NP masers in the laboratory showing that the frequency stability has been improved substantially to virtually the NR level. VLBI data is presented on the phase difference between NX-2 at Owens Valley, California and NR-2 at Fort Davis, Texas for a one week period showing, after removal of a constant frequency drift, a 350 ps RMS phase stability.

Chiu, M.

New auto-tuning technique for the hydrogen maser

Auto-tuning of the maser cavity compensates for cavity pulling effect, and other sources of contribution to the long term frequency drift. Schemes previously proposed for the maser cavity auto-tuning can have adverse effects on the performance of the maser. A new scheme is proposed based on the phase relationship between the electric and the magnetic fields inside the cavity. This technique has the desired feature of auto-tuning the cavity with a very high sensitivity and without disturbing the maser performance. Some approaches for the implementation of this scheme and possible areas of difficulty are examined.

Sydnor, R. L.

A compact hydrogen maser with exceptional long-term stability

A passive hydrogen maser employing a smaller microwave cavity than previous masers is described. The volume of the entire resonator package, including a conventional source, hexapole state selector, and four magnetic shields, is estimated at 20 liters. The techniques for constructing the ceramic cavity, coating it with FEP, and attaching the endcaps to achieve a stable container (to allow its use as a single vacuum system) are described in detail. Frequency stability measurements were made of four such masers, against an NBS-4 cesium primary standard, against each other, and against eight commercial cesium clocks; frequency stability level is reported as 1.7 x 10 to the -12th tau exp -1/2 from 1 to 100,000 sec, and no drift above 1 x 10 to the -15th/day was found. Pressure and temperature effects on frequency stability were found at the 1 x 10 to the -14th level. Noise behavior beyond 200,000 sec is characterized as random walk. The potential use of a compact stable maser as a clock is suggested.

Howe, D. A.

The superconducting cavity stability ruby maser oscillator

Analysis of an application of the rudy maser to a superconducting Cavity Stabilized oscillator shows many attractive features. These derive from the mechancial stability inherent in an all-cryogenic design and from the properties of the ruby maser itself. A multiple-cavity design has been developed to allow physical separation of the high-Q superconducting cavity and the ruby element with its requried applied magnetic field. Mode selection is accomplished in this design by tuning the ruby by means of the applied field. We conclude that such an oscillator would perform well, even with cavity Q's as low as 10 to the 8th power allowing the use of a superconductor-on-sapphire resonator with its greater rigidity and lower thermal expansion. A first test of the Superconducting Cavity Stabilized Maser Oscillator (SCSMO) confirms the efficacy of the multiple-cavity design and the applicability of the ruby maser. Frequency variation less than 4x10 to the minus 11th power was measured in the stabilized mode and is attributed to the reference oscillator and to instabilities in the pump source. Variation of 10 to the minus 10th power was observed in the low-Q unstabilized mode, again attributable to pump fluctuations. Even so, direct scaling to a Q of 10 the 9th power predicts a stability better than 10 to the minus 15th power. Together with results showing the lowest losses to date in sapphire at microwave frequencies, and preliminary experiments on superconductor-on-sapphire resonators, frequency stability, levels as low as 10 to the minus 17th power are indicated.

Dick, G. J.

Atomic hydrogen maser active oscillator cavity and bulb design optimization

The performance characteristics and reliability of the active oscillator atomic hydrogen maser depend upon oscillation parameters which characterize the interaction region of the maser, the resonant cavity and atom storage bulb assembly. With particular attention to use of the cavity frequency switching servo (1) to reduce cavity pulling, it is important to maintain high oscillation level, high atomic beam flux utilization efficiency, small spin exchange parameter and high cavity quality factor. It is also desirable to have a small and rigid cavity and bulb structure and to minimize the cavity temperature sensitivity. Curves for a novel hydrogen maser cavity configuration which is partially loaded with a quartz dielectric cylinder and show the relationships between cavity length, cavity diameter, bulb size, dielectric thickness, cavity quality factor, filling factor and cavity frequency temperature coefficient are presented. The results are discussed in terms of improvement in maser performance resulting from particular design choices.

Peters, H. E.

A low noise synthesizer for autotuning and performance testing of hydrogen masers

A low noise synthesizer has been developed for use in hydrogen maser autotuning and performance evaluation. This synthesizer replaces the frequency offset maser normally used for this purpose and allows the user to maintain all masers in the ensemble at the same frequency. The synthesizer design utilizes a quartz oscillator with a BVA resonator. The oscillator has a frequency offset of 5 X 10 to the minus 8 power. The BVA oscillator is phase-locked to a hydrogen maser by means of a high gain, high stability phase-locked loop, employing low noise multipliers as phase error amplifiers. A functional block diagram of the synthesizer and performance data will be presented.

Cloeren, J. M.

Performance data of US Naval Observatory VLG-11 hydrogen masers since September, 1983

In 1983, two VLC-11 masers were delivered to the U.S. Naval Observatory by the Smithsonian Astrophysical Observatory. Last year the short-term stability of these masers was reported and the effect of this short-term stability on timekeeping performance was examined. Since the date of installation, 13 September 1983, data on the masers' long-term performance have been accumulated. The Allan variance, agma(tau), of the relative frequency between the masers reaches a minimum of about 4 parts in 10 to the 16th power at averaging times 5,000 seconds and rises at longer averaging times due, at least partly, to systematic frequency drift. The systematic frequency drifts, expressed in units of fractional frequency difference per day are discussed.

Vessot, R. F. C.

A long-term study of SiO (v = 1, J = 2-1) maser emission from evolved stars and Orion A

General characteristics of eight late-type stars and Orion A in the SiO (v = 1, J = 2-1) maser line are reported based on observations made with the 20-m Onsala telescope between 1977 and 1984. Five stars show periodic maser flux variations that are well correlated with the infrared light curve, and the maximum SiO intensity and the dynamic range vary significantly between different periods and sources. Some long-term variations in the center velocity of the maser emission have been noted, with Omicron Cet possibly being a member of a binary system. Grand averages have been used to study the general velocity structure, and a global SiO (v = 1, J = 2-1) profile for Mira variables shows that the strongest emission is blueshifted with respect to the stellar velocity, while as a whole the emission is redshifted. The analysis places the SiO masers in a region between the pulsating stellar atmosphere and the expanding circumstellar envelope, where the velocity structure bears no relation to the expansion velocity of the shell.

Nyman, L.-A.

Radiative transfer in circumstellar 1612 MHz OH masers

A detailed investigation of radiative transfer in the 1612 MHz OH maser in the expanding envelopes around evolved stars is made in the context of the standard model in which the mass outflow is windlike. The most sensitive diagnostic of the models is the maser emission at the velocity of the star for which VLA and MERLIN data exist. Fully saturated models are analytically eliminated. Detailed numerical modeling also eliminates partially saturated models. The need to examine alternative models for the mass outflow is suggested by this conclusion. A model for the mass outflow from these stars is advocated in which all mass is lost by the ejection of blobs of material. These blobs, acted on by radiation pressure on grains, evolve into platelike structures in the OH maser region. It is shown that the peculiar difficulties of the standard model for the OH masers do not occur in this picture.

Alcock, C.

The electron-cyclotron maser instability as the source of solar type V continuum

In this paper, it is proposed that the electron-cyclotron (EC) maser instability can be the source of solar type V bursts. The propagation of electrons up an open field line is examined, and it is shown that the resultant distribution can be subject to the bump-in-tail (BIT) or the EC maser instabilities, or both. The characteristics of the emission from the BIT and EC maser instabilities when they are driven by such distributions are compared. It is proposed that type V bursts are produced by the coalescence of the upper hybrid waves produced by the maser instability, while type IIIs are produced by the BIT instability.

Winglee, R. M.

Evidence for cyclotron maser emission from the sun and stars

Recent observational and theoretical work on cyclotron maser instability is reviewed, with emphasis on the similarities between microwave spike bursts from the sun and bursts from stars and planets. Results on particle-in-cell simulations are discussed, and it is suggested that such studies may provide further information on the amount and efficiency of energy transfer by the maser radiation. Observational tests of the cyclotron maser theory are considered, in addition to the role of the cyclotron maser as an energy transport mechanism in solar flares.

Dulk, G. A.

Operating and environmental characteristics of Sigma Tau hydrogen masers used in the Very Long Baseline Array (VLBA)

Presented here are the results obtained from performance evaluation of a pair of Sigma Tau Standards Corporation Model VLBA-112 active hydrogen maser frequency standards. These masers were manufactured for the National Radio Astronomy Observatory (NRAO) for use on the Very Long Baseline Array (VLBA) project and were furnished to the Jet Propulsion Laboratory (JPL) for the purpose of these tests. Tests on the two masers were performed in the JPL Frequency Standards Laboratory (FSL) and included the characterization of output frequency stability versus environmental factors such as temperature, humidity, magnetic field, and barometric pressure. The performance tests also included the determination of phase noise and Allan variance using both FSL and Sigma Tau masers as references. All tests were conducted under controlled laboratory conditions, with only the desired environmental and operational parameters varied to determine sensitivity to external environment.

Tucker, T. K.

Interpretation of the newly discovered submillimeter water maser

The 10(29)-9(36)321 GHz water maser discovered recently by Menten et al. (1990) may be pumped collisionally under a wide range of physical conditions. This range of conditions is similar but not identical to that required to excite the well-studied 22 GHz water maser. The ratio of the observed 22 GHz and 321 GHz intersteller maser luminosities can be explained by collisional excitation within the same warm, dense gas. Collisional pumping in a circumstellar envelope can account for the observed 321 GHz maser emission in the supergiant star VY CMa.

Neufeld, David A.

Spectra of circularly polarized radiation from astrophysical OH masers

A striking feature of astrophysical masers is the tendency for either one or the other of the circular polarizations to dominate in the radiation from the strong, widely observed masing transitions of OH at 18 cm. Spectral line profiles are calculated for polarized maser radiation due to the combined effects of a velocity gradient and, as is indicated for these transitions, a Zeeman splitting that is at least comparable with the thermal contributions to the breadths of the spectral lines. The resulting spectral features are similar in appearance, including the presence of large net circular polarization and narrow line breadths, to the commonly observed spectra of OH masers in molecular clouds. The calculations presented here are performed as a function of frequency without making the approximations of a large velocity gradient. Rapid cross relaxation, which has been advocated by others for the OH masers, is assumed.

Nedoluha, Gerald E.

State of the art and future directions for the atomic hydrogen maser

The present status of technology development for atomic hydrogen masers (H-masers) is reviewed. The limitations to frequency stability and accuracy are discussed with emphasis on the problems associated with cavity resonator instability and the lack of reproducibility and stability of the storage volume wall coating frequency shift. New types of coating developed in the Soviet Union and better, cavity resonator materials, are expected to make possible frequency at the 10(exp -16) level at 10(exp 4) sec. Better control of systematic effects should extend the long-term stability to levels better than 10(exp -15) for intervals beyond one day. Present use of H-masers as flywheel oscillators in timekeeping systems is discussed as is the outlook for the future cryogenic and room temperature H-masers as flywheel oscillators to operate very high resolution frequency discriminators based on the newly evolving technology of trapped and cooled ions and atoms.

Vessot, Robert F. C.

The saturation of the electron-cyclotron maser instability and the interpretation of solar millisecond spikes

A self-consistent numeric two-dimensional code of the kinetic wave-particle equations developed to investigate the maser dynamics in the solar context is applied to solar millisecond-spike observations in order to improve the diagnostic capabilities of the theory of the electron-cyclotron maser instablitity. Attention is given to the inhomogeneity of the magnetic field selecting magneto-ionic modes with relatively short saturation lengths and suppressing mechanisms such as collisional deflection, free-free absorption, and gyroresonance absorption. The time scales of maser saturation in respect to time scales of global particle changes in a magnetic loop are covered, relevant observations of solar millisecond spikes are described, and the interpretation in terms of physical parameters deduced from the quasi-linear maser simulations are presented. It is demonstrated that the quasi-linear simulations make it possible to constrain the physical parameters from the observed time scale and frequency.

Aschwanden, M. J.

A hydrogen maser with cavity auto-tuner for timekeeping

A hydrogen maser frequency standard for timekeeping was worked on at the Shanghai Observatory. The maser employs a fast cavity auto-tuner, which can detect and compensate the frequency drift of the high-Q resonant cavity with a short time constant by means of a signal injection method, so that the long term frequency stability of the maser standard is greatly improved. The cavity auto-tuning system and some maser data obtained from the atomic time comparison.

C. F. Lin