Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of the magnetic moment distribution in low-concentration solutions of iron oxide nanoparticles by a high-T{sub c} superconducting quantum interference device magnetometer

We developed a highly sensitive AC/DC magnetometer using a high-temperature superconductor superconducting quantum interference device for the evaluation of magnetic nanoparticles in solutions. Using the developed system, we investigated the distribution of magnetic moments of iron oxide multi-core particles of 100 nm at various iron concentrations that are lower than 96 μg/ml by analyzing the measured magnetization curves. Singular value decomposition and non-regularized non-negative least-squares methods were used during the reconstruction of the distribution. Similar distributions were obtained for all concentrations, and the iron concentration could be determined from the measured magnetization curves. The measured harmonics upon the excitation of AC and DC magnetic fields curves agreed well with the harmonics simulated based on the reconstructed magnetization curves, implying that the magnetization curves of magnetic nanoparticles were successfully obtained as we will show in the article. We compared the magnetization curves between multi-core particles of 100 nm and 130 nm, composed of 12-nm iron oxide nanoparticles. A distinctive magnetic property between the 100 nm and 130 nm particles in low-concentration solutions was successfully characterized. The distribution characteristic of magnetic moments suggests that the net magnetic moment in a multi-core particle is affected by the size of the magnetic cores and their degree of aggregation. Exploration of magnetic properties with high sensitivity can be expected using the developed system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An atomic magnetometer with autonomous frequency stabilization and large dynamic range

The operation of a highly sensitive atomic magnetometer using elliptically polarized resonant light is demonstrated. It is based on measurement of zero magnetic field resonance in degenerate two level systems using polarimetric detection. The transmitted light through the polarimeter is used for laser frequency stabilization, whereas reflected light is used for magnetic field measurement. Thus, the experimental geometry allows autonomous frequency stabilization of the laser frequency leading to compact operation of the overall device and has a preliminary sensitivity of <10 pT/Hz{sup 1/2} @ 1 Hz. Additionally, the dynamic range of the device is improved by feedback controlling the bias magnetic field without compromising on its sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical cell for in situ electrodeposition of magnetic thin films in a superconducting quantum interference device magnetometer

An electrochemical cell is designed and applied for in situ electrodeposition of magnetic thin films in a commercial SQUID magnetometer system. The cell is constructed in such a way that any parasitic contribution of the cell and of the substrate for electrodeposition to the magnetic moment of the deposited film is reduced to a minimum. A remanent minor contribution is readily taken into account by a proper analysis of the detected signal. Thus, a precise determination of the absolute magnetic moment of the electrodeposited magnetic film during its growth and dissolution is achieved. The feasibility of the cell design is demonstrated by performing Co electrodeposition using cyclic voltammetry. For an average Co film thickness of (35.6 ± 3.0) atomic layers, a magnetic moment per Co atom of (1.75 ± 0.11) μ{sub B} was estimated, in good agreement with the literature bulk value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S{sub Φ}{sup 1/2} decreases as 1/N{sup 1/2}. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa{sub 2}Cu{sub 3}O{sub 7}. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S{sub Φ}{sup 1/2} between (0.25 and 0.44) μΦ{sub 0}/Hz{sup 1/2} for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A three-axis SQUID-based absolute vector magnetometer

We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilayer MgB{sub 2} superconducting quantum interference filter magnetometers

We report two types of all-MgB{sub 2} superconductive quantum interference filter (SQIF) magnetometers that can measure absolute magnetic fields with high sensitivity. In one configuration, the SQIFs were made of 20 multilayer nonplanar all-MgB{sub 2} superconducting quantum interference devices (SQUIDs) connected in parallel with loop areas ranging in size from 0.4 to 3.6 μm{sup 2}. These devices are sensitive to magnetic fields parallel to the substrate and show a single antipeak from 3 to 16 K with a maximum transfer function of ∼16 V/T at 3 K and a field noise of ∼110 pT/Hz{sup 1/2} above 100 Hz at 10 K. In a second configuration, the SQIFs were made with 16 planar SQUIDs connected in parallel with loop areas ranging in size from 4 μm{sup 2} to 25 μm{sup 2} and are sensitive to the magnetic fields perpendicular to the substrate. The planar SQIF shows a single antipeak from 10 to 22 K with a maximum transfer function of 7800 V/T at 10 K and a field noise of ∼70 pT/Hz{sup 1/2} above 100 Hz at 20 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eddy current imaging with an atomic radio-frequency magnetometer

We use a radio-frequency {sup 85}Rb alkali-vapor cell magnetometer based on a paraffin-coated cell with long spin-coherence time and a small, low-inductance driving coil to create highly resolved conductivity maps of different objects. We resolve sub-mm features in conductive objects, we characterize the frequency response of our technique, and by operating at frequencies up to 250 kHz we are able to discriminate between differently conductive materials based on the induced response. The method is suited to cover a wide range of driving frequencies and can potentially be used for detecting non-metallic objects with low DC conductivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three axis vector atomic magnetometer utilizing polarimetric technique

The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Scanning Optical Quantum Magnetometer Based on the Hole Burning Phenomenon

A scanning optical quantum magnetometer with submicron spatial resolution is proposed that is based on the phenomenon of hole burning in the signal of optically detected magnetic resonance (ODMR) on atomic-sized color centers in silicon carbide crystals under conditions of spin level saturation by means of additional high-frequency resonance pumping. An increase in the sensitivity is achieved due to narrowing of the ODMR line and increasing slope of the dependence of signal frequency on the magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Superconducting Micro-Magnetometer for Quantum Vortex in Superconducting Nanoflakes

Superconducting quantum interferometer device (SQUID) plays a key role in understanding electromagnetic properties and emergent phenomena in quantum materials. The technological appeal of SQUID is that its detection accuracy for the electromagnetic signal can precisely reach the quantum level of a single magnetic flux. However, conventional SQUID techniques normally can only be applied to a bulky sample and do not have the capability to probe the magnetic properties of micro-scale samples with small magnetic signals. Here, in this paper, it is demonstrated that, based on a specially designed superconducting nano-hole array, the contactless detection of magnetic properties and quantized vortices in micro-sized superconducting nanoflakes is realized. An anomalous hysteresis loop and a suppression of Little–Parks oscillation are observed in the detected magnetoresistance signal, which originates from the disordered distribution of the pinned vortices in Bi 2 Sr 2 CaCu 2 O 8+δ . Therefore, the density of pinning centers of the quantized vortices on such micro-sized superconducting samples can be quantitatively evaluated, which is technically inaccessible for conventional SQUID detection. The superconducting micro-magnetometer provides a new approach to exploring mesoscopic electromagnetic phenomena of quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Magnetometer Based on a Spin Wave Interferometer

Here, we describe a magnetic field sensor based on a spin wave interferometer. Its sensing element consists of a magnetic cross junction with four micro-antennas fabricated at the edges. Two of these antennas are used for spin wave excitation while two other antennas are used for detection of the inductive voltage produced by the interfering spin waves. Two waves propagating in the orthogonal arms of the cross may accumulate significantly different phase shifts depending on the magnitude and direction of the external magnetic field. This phenomenon is utilized for magnetic field sensing. The sensitivity attains its maximum under the destructive interference condition, where a small change in the external magnetic field results in a drastic increase of the inductive voltage, as well as in the change of the output phase. We report experimental data obtained for a micrometer scale Y 3 Fe 2 (FeO 4 ) 3 cross structure. The change of the inductive voltage near the destructive interference point exceeds 40 dB per 1 Oe. The phase of the output signal exhibits a π-phase shift within 1 Oe. The data are collected at room temperature. Taking into account the low thermal noise in ferrite structures, we estimate that the maximum sensitivity of the spin wave magnetometer may exceed attotesla.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive magnetic microscopy with an optically pumped magnetometer

Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). Additionally, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

47 OTHER INSTRUMENTATION↗

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer

We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.

59 BASIC BIOLOGICAL SCIENCES↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Constraint on an Exotic Spin- and Velocity-Dependent Interaction in the Sub-meV Range of Axion Mass with a Spin-Exchange Relaxation-Free Magnetometer

Here, we conducted a search for an exotic spin- and velocity-dependent interaction for polarized electrons with an experimental approach based on a high-sensitivity spin-exchange relaxation-free (SERF) magnetometer, which serves as both a source of polarized electrons and a magnetic-field sensor. The experiment aims to sensitively detect magnetic-fieldlike effects from the exotic interaction between the polarized electrons in a SERF vapor cell and unpolarized nucleons of a closely located solid-state mass. We report experimental results on the interaction with 82 h of data averaging, which sets an experimental limit on the coupling strength around 10 –19 for the axion mass m a ≲ 10 –3 eV, within the important axion window.

74 ATOMIC AND MOLECULAR PHYSICS↗

Four-channel optically pumped atomic magnetometer for magnetoencephalography

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.

47 OTHER INSTRUMENTATION↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗