At least 91 records · Page 5

Solar radio observations in support of Skylab A

The solar radio spectra were recorded in real time, both on film and magnetic tape, during the period from November 1972 to February 1974. A catalogue of the observations is given for the frequency range 565-1000 MHz and includes descriptions of the bursts, intensity scales, and pertinent remarks. Some theoretical considerations resulting from the research are given. Equipment modified for the experiment is described and the text of the final report which summarizes the research on type IV solar radio bursts is included.

Gotwols, B. L.↗

Four-micron period ion-implanted bubble test circuits

Packaged magnetic bubble test circuits made with 4-micron period ion-implanted circuits were operated over -55 to +110 C. The circuits used bidirectional transfer and nondestructive detection and were made on bismuth-containing magnetic garnet films. Passivated circuits that incorporated an improved transfer conductor design were operated on films with higher Gilbert damping parameters. Potential advantages to using films with lower bubble aspect ratios for ion-implanted circuits are discussed. However nondestructive read-out detection was not realized with these 'flat' bubbles.

Nelson, T. J.↗

NSSDC data listing

This document identifies, in a highly summarized way, all the data held at the NSSDC. These data cover astrophysics and astronomy, solar and space physics, planetary and lunar, and Earth science disciplines. They are primarily, but not exclusively, from past and ongoing NASA spaceflight missions. We first identify all the data electronically available through NSSDC's principal online (magnetic disk-based) and nearline (robotics jukebox-based) systems, and then those data available on CDROM's. Finally, we identify all NSSDC-held data, the majority of which are still offline on magnetic tape, film, etc., but including the electronically accessible and CD-ROM resident data of earlier sections. These comprehensive identifications are in the form of two listings, one for the majority of NSSDC-held data sets resulting from individual instruments flown on individual spacecraft, and the other listing for the remainder of NSSDC-held data sets which do not adhere to this spacecraft/experiment/dataset hierarchy. The latter listing is presented in two parts, one for the numerous source catalogs of the NSSDC-operated Astronomical Data Center, and the other for the remainder. Access paths to all these data, and to further information about each, are also given in the related sections of this Data Listing. Note that this document is a companion to the electronically accessible information files (in particular, the NASA Master Directory) at NSSDC which also identify NSSDC-resident (and other) data.

Horowitz, Richard↗

NSSDC data listing

This document identifies, in a highly summarized way, all the data held at the National Space Science Data Center (NSSDC). These data cover astrophysics and astronomy, solar and space physics, planetary and lunar, and Earth science disciplines. They are primarily but not exclusively from past and on-going NASA spaceflight missions. We first identify all the data electronically available through NSSDC's principal on-line (magnetic disk-based) and near-line (robotics jukebox-based) systems and then those data available on CD-ROM's. Finally, we identify all NSSDC-held data, the majority of which are still off line on magnetic tape, film, etc., but include the electronically accessible and CD-ROM-resident data of earlier sections. These comprehensive identifications are in the form of two listings, one for the majority of NSSDC-held data sets resulting from individual instruments flown on individual spacecraft and the other for the remainder of NSSDC-held data sets that do not adhere to this spacecraft/experiment/data set hierarchy. The latter listing is presented in two parts, one for the numerous source catalogs of the NSSDC-operated Astronomical Data Center and the other for the remainder.

Horowitz, Richard↗

SSC OCIO, IT SUMMIT 2011

The Stennis Space Center (SSC) Records Retention Facility is a centralized location for all SSC records, Records Management staff, and the SSC History Office. The building is a storm resistant facility and provides a secure environment for records housing. The Records Retention Facility was constructed in accordance with The National Archives and Records Administration (NARA) requirements for records storage, making it the first NARA compliant facility in the agency. Stennis Space Center's Records Retention Facility became operational in May 2010. The SSC Records Retention Facility ensures that the required federal records are preserved, managed and accessible to all interested personnel. The facility provides 20,000 cubic feet of records storage capacity for the purpose of managing the centers consolidated records within a central, protected environment. Records housed in the facility are in the form of paper, optical, film and magnetic media. Located within the SSC Records Retention Facility, the Records Management Office provides comprehensive records management services in the form of: a) Storage and life-cycle management of inactive records of all media types; b) Digitizing/scanning of records and documents; c) Non-textual/digital electronic records media storage, migration and transfer; d) Records Remediation.

Cottrell, Dinna L.↗

Characterization facility for magneto-optic media and systems

Objectives of this research are: (1) to measure the hysteresis loop, Kerr rotation angle, anisotropy energy profile, Hall voltage, and magnetoresistance of thin-film magneto-optic media using our loop-tracer; (2) measure the wavelength-dependence of the Kerr rotation angle, Theta(sub k), and ellipticity, epsilon(sub k), for thin-film media using our magneto-optic Kerr spectrometer (MOKS); (3) measure the dielectric tensor of thin-film and multilayer samples using our variable-angle magneto-optic ellipsometer (VAMOE); (4) measure the hysteresis loop, coercivity, remanent magnetization, saturation magnetization, and anisotropy energy constant for thin film magnetic media using vibrating sample magnetometry; (5) observe small magnetic domains and investigate their interaction with defects using magnetic force microscopy; (6) perform static read/write/erase experiments on thin-film magneto-optic media using our static test station; (7) integrate the existing models of magnetization, magneto-optic effects, coercivity, and anisotropy in an interactive and user-friendly environment, and analyze the characterization data obtained in the various experiments, using this modeling package; (8) measure focusing- and tracking-error signals on a static testbed, determine the 'feedthrough' for various focusing schemes, investigate the effects of polarization and birefringence, and compare the results with diffraction-based calculations; and (9) measure the birefringence of optical disk substrates using two variable angle ellipsometers.

Mansuripur, M.↗

NASA Earth Science Data Rescue Efforts

Historically, at the end of a NASA mission, earth and space science data were stored at NASA's National Space Science Data Center (NSSDC). The original data archive consisted of both magnetic tapes and film media. As data storage technology improved, data from later missions were stored on disks and platters and higher capacity magnetic media for online accessibility. To conserve physical space at NASA archive sites and to meet disaster recovery guidelines, historical data originally stored on magnetic tapes and film were moved to the Federal Archives and Record Center (FRC) as a temporary holding area until its long-term value was determined by NASA. All records at the FRC are controlled by the NASA Records Retention Schedule (NRRS) which determines the disposal date for each record. On that date, responsible NASA parties are notified that all scheduled records should be reviewed and assessed to determine if they continue to hold significant historical, scientific or administrative value. For Earth Science data records being held at FRC, the Earth Science Data and Information System (ESDIS) Project office is the party responsible for making the value assessment that determines which records warrant preservation and which are ready for proper disposal according to NASA guidelines. Once the data's long-term value is determined, ESDIS takes definitive steps to preserve this data for future discovery and access. Deteriorating media containing historic data of value are recalled from FRC and brought back to ESDIS. Through a tedious, laborious process, digital data are recovered and restored to modern formats with improved metadata and documentation to aid discovery. The restored digital products are then incorporated into our modern online archive, and made immediately accessible to the public. In this paper, we will discuss how we identify data-at-risk, ways to minimize data loss, how we plan for recovery, how we delegate recovery activities to our archive facilities, and how we make recovered data more accessible.

Data Systems; Social and Information sciences↗

Lower critical field measurements in NbN bulk and thin films.

Low-field magnetization measurements were made at 4.2 K on thin-film and bulk NbN samples by using a vibrating-sample Foner magnetometer with a 50-kG superconducting solenoid. Values of the lower and upper critical fields are calculated, using magnetization curves as the basis. The significance of the Pauli spin paramagnetism and spin-orbit scattering in these materials is discussed.

Mathur, M. P.↗

Selected spectroscopic and magnetic properties of lanthanide complexes in polyimide XU-218

Polyimide XU-218 films containing approximately 5 wt pct of Eu(III), Gd(III), Tb(III), and Er(III) were prepared, and the effects of complexing each of the metals with the following four ligands were investigated: N-phenylphthalamate (NPPA), 2,4-pentanedionate (AcAc), 1,3-diphenyl 1,3-propanedionate (DBM), and a new hexa-aza-macrocyclic (MAC) ligand. The tris-chelated complexes of the mononegative ligands NPPA, AcAc, and DBM produced transparent, flexible films, which had magnetic and spectral properties very similar to those of the parent lanthanide complexes, while complexes of MAC showed problems due to the presence of lattice water and yielded dark brittle films. AcAc caused little or no effect on the glass transition temperature (Tg), while NPPA and DBM complexes lowered Tg to 269-290 C, and MAC indicated moisture by inflexion at 95-100 C with a true Tg at 320 C. All lanthanide-containing films were paramagnetic.

Stoakley, D. M.↗

A remotely interrogatable sensor for chemical monitoring

A new type of continuously operating, in-situ, remotely monitored sensor is presented. The sensor is comprised of a thin film array of magnetostatically coupled, magnetically soft ferromagnetic thin film structures, adhered to or encased within a thin polymer layer. The polymer is made so that it swells or shrinks in response to the chemical analyte of interest, which in this case is pH. As the polymer swells or shrinks, the magnetostatic coupling between the magnetic elements changes, resulting in changes in the magnetic switching characteristics of the sensor. Placed within a sinusoidal magnetic field the magnetization vector of the coupled sensor elements periodically reverses directions, generating magnetic flux that can be remotely detected as a series of voltage spikes in appropriately placed pickup coils. one preliminary sensor design consists of four triangles, initially spaced approximately 50 micrometers apart, arranged to form a 12 mm x 12 mm square with the triangle tips centered at a common origin. Our preliminary work has focused on monitoring of pH using a lightly crosslinked pH sensitive polymer layer of hydroxyethylmethacrylate and 2-(dimethylamino) ethylmethacrylate. As the polymer swells or shrinks the magnetostatic coupling between the triangles changes, resulting in measurable changes in the amplitude of the detected voltage spirits.

Non-NASA Center↗

Effects of dc bias on the fabrication of amorphous GdCo RF sputtered films

An investigation has been conducted on the effects of a dc bias field applied to Gd(1-x)Co(x) thin films during RF sputter deposition. Such films may possess uniaxial magnetic anisotropy with easy axis perpendicular to the plane of the film and may be used in magnetic bubble devices. Uniformity in composition, thickness and magnetic properties has been achieved and film composition has been controlled to within one percent. However, significant variations of magnetic properties were observed from film to film.

Bourne, H. C., Jr.↗

Synthesis and superconducting properties of Tl-Ba-Ca-Cu-O films

Tl-Ba-Ca-Cu-O superconducting films were synthesized by sputtering either from a single target or from two oxide targets in a symmetric configuration. Films with zero resistance Tc of up to 122 K were obtained after various postannealing treatments at 870-950 C under an oxygen atmosphere. The composition of the films is not very homogeneous on the submicrometer scale. The critical current of these films at 77 K is in the 1000 A/sq cm to 10,000 A/sq cm range, which is much smaller than that of films prepared on SrTiO3 and LaAlO3 substrates. The low critical current density in these films is probably due to the granularity in the films. The morphology, structure, and magnetic and superconducting properties of the films were studied. Films prepared by two different sputtering techniques have similar results which depend mostly on the film compositions and their annealing conditions. It is found that the induced magnetic flux in the film decreases rapidly with increasing temperature, indicating weak flux pinning.

Liou, S. H.↗

Magnetic flux penetration into superconducting thin films.

The quantum-interference technique developed by Meservey (1965) is used to measure directly the absolute value of the penetration depth in lead in tin superconducting thin films. The technique assumes that the change in phase of the superconducting wave function around any contour within the superconductor must be 2 pi n, where n is a nonnegative integer. Results show that the critical current of a superconducting interferometer with two parallel junctions is not strictly periodic in the applied magnetic flux with a period equal to the flux quantum because of the magnetic field dependence of the critical currents of the junctions.

Peabody, G. E.↗

Extended-life magnetic recording heads

Recording head has standard ferrite core directly coated with a thin film of a magnetic alloy composed of aluminum, iron, and silicon. Coated head has a lifespan from five to ten times longer than that of conventional heads and shows superior inductance characteristics and frequency response.

Kern, J. D.↗

Nonvolatile random access memory

A nonvolatile magnetic random access memory can be achieved by an array of magnet-Hall effect (M-H) elements. The storage function is realized with a rectangular thin-film ferromagnetic material having an in-plane, uniaxial anisotropy and inplane bipolar remanent magnetization states. The thin-film magnetic element is magnetized by a local applied field, whose direction is used to form either a 0 or 1 state. The element remains in the 0 or 1 state until a switching field is applied to change its state. The stored information is detcted by a Hall-effect sensor which senses the fringing field from the magnetic storage element. The circuit design for addressing each cell includes transistor switches for providing a current of selected polarity to store a binary digit through a separate conductor overlying the magnetic element of the cell. To read out a stored binary digit, transistor switches are employed to provide a current through a row of Hall-effect sensors connected in series and enabling a differential voltage amplifier connected to all Hall-effect sensors of a column in series. To avoid read-out voltage errors due to shunt currents through resistive loads of the Hall-effect sensors of other cells in the same column, at least one transistor switch is provided between every pair of adjacent cells in every row which are not turned on except in the row of the selected cell.

Wu, Jiin-Chuan↗

Magnetic penetration depth of YBa2Cu3O(7-delta) thin films determined by the power transmission method

A power transmission measurement technique was used to determine the magnetic penetration depth (lambda) of YBa2Cu3O(7-delta) superconducting thin films on LaAlO3 within the 26.5 to 40.0 GHz frequency range, and at temperatures from 20 to 300 K. Values of lambda ranging from 1100 to 2500 A were obtained at low temperatures. The anisotropy of lambda was determined from measurements of c-axis and a-axis oriented films. An estimate of the intrinsic value of lambda of 90 +/- 30 nm was obtained from the dependence of lambda on film thickness. The advantage of this technique is that it allows lambda to be determined nondestructively.

Heinen, Vernon O.↗