Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lynx”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-152: Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil BeamScanning Proton Therapy Treatment Planning System in Heterogeneous Media

Purpose: Eclipse AcurosPT 13.7, the first commercial Monte Carlo pencil beam scanning (PBS) proton therapy treatment planning system (TPS), was experimentally validated for an IBA dedicated PBS nozzle in the CIRS 002LFC thoracic phantom. Methods: A two-stage procedure involving the use of TOPAS 1.3 simulations was performed. First, Geant4-based TOPAS simulations in this phantom were experimentally validated for single and multi-spot profiles at several depths for 100, 115, 150, 180, 210 and 225 MeV proton beams, using the combination of a Lynx scintillation detector and a MatriXXPT ionization chamber array. Second, benchmark calculations were performed with both AcurosPT and TOPAS in a phantom identical to the CIRS 002LFC, with the exception that the CIRS bone/mediastinum/lung tissues were replaced with similar tissues that are predefined in AcurosPT (a limitation of this system which necessitates the two stage procedure). Results: Spot sigmas measured in tissue were in agreement within 0.2 mm of TOPAS simulation for all six energies, while AcurosPT was consistently found to have larger spot sigma (<0.7 mm) than TOPAS. Using absolute dose calibration by MatriXXPT, the agreements between profiles measurements and TOPAS simulation, and calculation benchmarks are over 97% except near the end of range using 2 mm/2% gamma criteria. Overdosing and underdosing were observed at the low and high density side of tissue interfaces, respectively, and these increased with increasing depth and decreasing energy. Near the mediastinum/lung interface, the magnitude can exceed 5 mm/10%. Furthermore, we observed >5% quenching effect in the conversion of Lynx measurements to dose. Conclusion: We recommend the use of an ionization chamber array in combination with the scintillation detector to measure absolute dose and relative PBS spot characteristics. We also recommend the use of an independent Monte Carlo calculation benchmark for the commissioning of a commercial TPS. Partially supported by Varian Medical System under the master agreement between Varian and University of pennsylvania.

60 APPLIED LIFE SCIENCES↗

Searching for Faint X-Ray Emission from Galactic Stellar Wind Bow Shocks

We present a stacking analysis of 2.61 Ms of archival Chandra observations of stellar wind bow shocks. We place an upper limit on the X-ray luminosity of infrared-detected bow shocks of <2 × 10{sup 29} erg s{sup −1}, a more stringent constraint than has been found in previous archival studies and dedicated observing campaigns of nearby bow shocks. We compare the X-ray luminosities and L {sub X}/L {sub bol} ratios of bow shock driving stars to those of other OB stars within the Chandra field of view. Driving stars are, on average, of later spectral type than the field-of-view OB stars, and we do not observe any unambiguously high L {sub X}/L {sub bol} ratios indicative of magnetic stars in our sample. We additionally assess the feasibility of detecting X-rays from stellar wind bow shocks with the proposed Lynx X-ray Observatory. If the X-ray flux originating from the bow shocks is just below our Chandra detection limit, the nearest bow shock in our sample (at ∼0.4 kpc with an absorbing column of ∼10{sup 21} cm{sup −2}) should be observable with Lynx in exposure times on the order of ∼100 ks.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Mirror Tech Days (11/02/2021)Next Generation Astronomical X-ray Optics:High Resolution, Light Weight, & Low Cost

We have demonstrated the basic elements of a technology to make high-resolution, light-weight, and low-cost X-ray optics. We continue to advance this technology to meet all requirements of Lynx: performance and programmatic. This technology uses only commercially available equipment and materials. It piggybacks on the semiconductor industry, avoiding obsolescence and ensuring continual advance. This technology can be used for missions of all sizes: sub-orbital, SmallSats, Pioneers, SMEX, MIDEX, Probes, and Flagships(Lynx).

X-Ray↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Optimization Workflow Status Update

Economically optimal and safe operation of integrated energy systems (IES) requires optimization at many different time scales. A real-time optimization (RTO) workflow will attempt to maximize revenue and minimize operational costs on a time scale of minutes to hours. Such a workflow requires the use of a digital twin (DT), which is a virtual representation of a physical system. The DT is updated using real-time data from the physical system, and serves as a model in an optimization framework. The optimization results are then sent back to the physical system to complete the loop. This report details the progress made in developing building blocks for a DT/RTO framework. The Risk Analysis Virtual Environment (RAVEN) platform within the Framework for Optimization of Resources and Economics (FORCE) tool suite can perform many of the tasks required for building a DT and performing RTO. The first item of this report details RAVEN enhancements that enable RAVEN workflows to be run in various environments. Data communication between the physical system and its DT is essential for successful RTO. This includes preprocessing real-time data, loading data into a data warehouse, and querying the stored data. The second section of this report describes the progress made in implementing an adapter in Python in order for Deep Lynx to handle the data communication. Typical dispatch optimization frameworks are built on linear programming (LP). The prototype RTO workflow developed in this report uses an LP problem as a part of a receding-horizon- or economic model predictive control (EMPC) based optimization. The third section of this report details the framework of an RTO workflow in which the system consists of a simple electrical storage device. A DT can be built from a reduced-order model (ROM). Integrating a ROM into a typical LP optimization framework has been challenging because most optimization packages require the user to write algebraic expressions for the system model. The final section of this report shows how an externally built RAVEN ROM can be integrated in an RTO framework by using the Python package Pyomo. This demonstrates the RTO workflow capability from a software-only perspective and is an important step in demonstrating the capability to implement an RTO workflow for a physical system.

97 MATHEMATICS AND COMPUTING↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Spectral line identification from a photoionised silicon plasma in emission

Next-generation X-ray satellite telescopes such as XRISM, NewAthena and Lynx will enable observations of exotic astrophysical sources at unprecedented spectral and spatial resolution. Proper interpretation of these data demands that the accuracy of the models is at least within the uncertainty of the observations. One set of quantities that might not currently meet this requirement is transition energies of various astrophysically relevant ions. Current databases are populated with many untested theoretical calculations. Accurate laboratory benchmarks are required to better understand the coming data. We obtained laboratory spectra of X-ray lines from a silicon plasma at an average spectral resolving power of ∼7500 with a spherically bent crystal spectrometer on the Z facility at Sandia National Laboratories. Many of the lines in the data are measured here for the first time. We report measurements of 53 transitions originating from the K-shells of He-like to B-like silicon in the energy range between ∼1795 and 1880 eV (6.6–6.9 Å). The lines were identified by qualitative comparison against a full synthetic spectrum calculated with ATOMIC. The average fractional uncertainty (uncertainty/energy) for all reported lines is ∼5.4 × 10 −5 . We compare the measured quantities against transition energies calculated with RATS and FAC as well as those reported in the NIST ASD and XSTAR’s uaDB. Average absolute differences relative to experimentally measured values are 0.20, 0.32, 0.17 and 0.38 eV, respectively. All calculations/databases show good agreement with the experimental values; NIST ASD shows the closest match overall.

astrophysical plasmas↗

A SEARCH FOR COSMIC MICROWAVE BACKGROUND ANISOTROPIES ON ARCMINUTE SCALES WITH BOLOCAM

We have surveyed two science fields totaling 1 deg.{sup 2} with Bolocam at 2.1 mm to search for secondary Cosmic Microwave Background (CMB) anisotropies caused by the Sunyaev-Zel'dovich effect (SZE). The fields are in the Lynx and Subaru/XMM SDS1 fields. Our survey is sensitive to angular scales with an effective angular multipole of l{sub eff} = 5700 with FWHM{sub l} = 2800 and has an angular resolution of 60 arcsec FWHM. Our data provide no evidence for anisotropy. We are able to constrain the level of total astronomical anisotropy, modeled as a flat-band power in C{sub l}, with most frequent 68%, 90%, and 95% CL upper limits of 590, 760, and 830 {mu}K {sup 2} {sub CMB}. We statistically subtract the known contribution from primary CMB anisotropy, including cosmic variance, to obtain constraints on the SZE anisotropy contribution. Now including flux calibration uncertainty, our most frequent 68%, 90%, and 95% CL upper limits on a flat-band power in C{sub l} are 690, 960, and 1000 {mu}K {sup 2} {sub CMB}. When we instead employ the analytical spectrum suggested by Komatsu and Seljack in 2002, and account for the non-Gaussianity of the SZE anisotropy signal, we obtain upper limits on the average amplitude of their spectrum weighted by our transfer function of 790, 1060, and 1080 {mu}K {sup 2} {sub CMB}. We obtain a 90% CL upper limit on {sigma}{sub 8}, which normalizes the power spectrum of density fluctuations, of 1.57. These are the first constraints on anisotropy and {sigma}{sub 8} from survey data at these angular scales at frequencies near 150 GHz.

99 GENERAL AND MISCELLANEOUS↗

EARLY-TYPE GALAXIES AT z {approx} 1.3. II. MASSES AND AGES OF EARLY-TYPE GALAXIES IN DIFFERENT ENVIRONMENTS AND THEIR DEPENDENCE ON STELLAR POPULATION MODEL ASSUMPTIONS

We have derived masses and ages for 79 early-type galaxies (ETGs) in different environments at z {approx} 1.3 in the Lynx supercluster and in the GOODS/CDF-S field using multi-wavelength (0.6-4.5 {mu}m; KPNO, Palomar, Keck, Hubble Space Telescope, Spitzer) data sets. At this redshift the contribution of the thermally pulsing asymptotic giant branch (TP-AGB) phase is important for ETGs, and the mass and age estimates depend on the choice of the stellar population model used in the spectral energy distribution fits. We describe in detail the differences among model predictions for a large range of galaxy ages, showing the dependence of these differences on age. Current models still yield large uncertainties. While recent models from Maraston and Charlot and Bruzual offer better modeling of the TP-AGB phase with respect to less recent Bruzual and Charlot models, their predictions do not often match. The modeling of this TP-AGB phase has a significant impact on the derived parameters for galaxies observed at high redshift. Some of our results do not depend on the choice of the model: for all models, the most massive galaxies are the oldest ones, independent of the environment. When using the Maraston and Charlot and Bruzual models, the mass distribution is similar in the clusters and in the groups, whereas in our field sample there is a deficit of massive (M {approx}> 10{sup 11} M{sub sun}) ETGs. According to those last models, ETGs belonging to the cluster environment host on average older stars with respect to group and field populations. This difference is less significant than the age difference in galaxies of different masses.

79 ASTRONOMY AND ASTROPHYSICS↗

EARLY-TYPE GALAXIES AT z {approx} 1.3. IV. SCALING RELATIONS IN DIFFERENT ENVIRONMENTS

We present the Kormendy and mass-size relations (MSR) for early-type galaxies (ETGs) as a function of environment at z {approx} 1.3. Our sample includes 76 visually classified ETGs with masses 10{sup 10} < M/M{sub Sun} < 10{sup 11.5}, selected in the Lynx supercluster and in the Great Observatories Origins Deep Survey/Chandra Deep Field South field; 31 ETGs in clusters, 18 in groups, and 27 in the field, all with multi-wavelength photometry and Hubble Space Telescope/Advanced Camera for Surveys observations. The Kormendy relation, in place at z {approx} 1.3, does not depend on the environment. The MSR reveals that ETGs overall appear to be more compact in denser environments: cluster ETGs have sizes on average around 30%-50% smaller than those of the local universe and a distribution with a smaller scatter, whereas field ETGs show an MSR with a similar distribution to the local one. Our results imply that (1) the MSR in the field did not evolve overall from z {approx} 1.3 to present; this is interesting and in contrast to the trend found at higher masses from previous works; (2) in denser environments, either ETGs have increased in size by 30%-50% on average and spread their distributions, or more ETGs have been formed within the dense environment from non-ETG progenitors, or larger galaxies have been accreted to a pristine compact population to reproduce the MSR observed in the local universe. Our results are driven by galaxies with masses M {approx}< 2 Multiplication-Sign 10{sup 11} M{sub Sun} and those with masses M {approx} 10{sup 11} M{sub Sun} follow the same trends as that of the entire sample. Following the Valentinuzzi et al. definition of superdense ETGs, {approx}35%-45% of our cluster sample is made up of superdense ETGs.

79 ASTRONOMY AND ASTROPHYSICS↗

Occurrence and molecular characterization of Enterocytozoon bieneusi in wild and domestic animal species in Portugal

Abstract The phylum Microsporidia encompasses a diverse group of obligate, intracellular, and spore-forming organisms able to infect a wide range of animal hosts. Among them, Enterocytozoon bieneusi is the most frequently reported species in humans and animals. Little is known about the presence and epidemiology of E. bieneusi in wildlife. We investigated E. bieneusi occurrence and genetic diversity in wild and domestic mammals, through molecular-detection methods, from different regions across Portugal. A total of 756 samples were collected from 288, 242, and 226 wild carnivores, wild ungulates, and domestic animals, respectively. Overall, eight specimens were E. bieneusi-positive (1.1%, 8/756) obtained from five wild (Iberian lynx, Iberian wolf, red fox, stone marten, and wild boar) and one domestic (sheep) host. Nucleotide sequence analysis identified four genotypes of E. bieneusi, Type IV, Wildboar3, BEB6, and PtEbIX. Three of those genotypes belong to Groups 1 (Type IV and Wildboar3) and 2 (BEB6), which are known to contain genotypes capable of infecting a variety of hosts, including humans, highlighting their public health importance. PtEbIX belongs to the dog-specific Group 11. This study represents the first, largest, and most comprehensive molecular-based epidemiology survey carried out in Portugal in wild and domestic animals to date and the first worldwide identification of E. bieneusi in wolf species. Our study showed that wild carnivores and ungulates may act as reservoirs of zoonotic genotypes of E. bieneusi, establishing their role in maintaining the sylvatic cycle of this parasite while representing a potential source of infection for humans and domestic animals.

Figueiredo, Ana M. (ORCID:0000000226236340)↗

XMP gas-rich dwarfs in nearby voids: results of BTA spectroscopy

We present the second part of results of the ongoing project aimed at searching for and studying eXtremely Metal-Poor (XMP) – adopted as those with Z gas ≲ Z ⊙ /30, or with 12+log (O/H) ≲ 7.21 dex - very gas-rich blue dwarfs in voids. They were first identified in the course of the ‘unbiased’ study of the galaxy population in the nearby Lynx–Cancer void. These very rare and unusual galaxies seem to be the best proxies of so-called Very Young Galaxies (VYGs) defined recently in model simulations by Tweed et al. To date, for 16 pre-selected void XMP candidates, using the Big Telescope Alt-azimuth (BTA), the SAO 6-m telescope, we have obtained spectra suitable for the determination of O/H. For majority of the observed galaxies, the principal line [O iii] λ4363 , used for the direct classical T e method of O/H determination, is undetected. Therefore, to estimate O/H, we use a new ‘strong-lines’ method by Izotov et al. This appears to be the most accurate empirical O/H estimator for the range of 12+log (O/H) ≲ 7.4–7.5. For objects with higher O/H, we use the semi-empirical method by Izotov & Thuan with our modification accounting for variance of the excitation parameter O 32 . Six of those 16 candidates are found, with confidence, to be XMP dwarfs. In addition, eight studied galaxies are less metal-poor, with 12+log (O/H) = 7.24–7.33, and these can also fall into the category of VYG candidates. Taking into account our recently published work and the previously known (nine prototype galaxies) XMP gas-rich void objects, the new findings increase the number of this type of galaxy known to date to a total of 19.

79 ASTRONOMY AND ASTROPHYSICS↗

Microlensing of x-ray pulsars: A method to detect primordial black hole dark matter

Primordial black holes (PBHs) with a mass from 10 -16 to 10 -11 M ⊙ may comprise 100% of dark matter. Due to a combination of wave and finite source size effects, the traditional microlensing of stars does not probe this mass range. Here, we point out that x-ray pulsars with higher photon energies and smaller source sizes are good candidate sources for microlensing for this mass window. Among the existing x-ray pulsars, the Small Magellanic Cloud (SMC) X-1 source is found to be the best candidate because of its apparent brightness and long distance from Earth. We have analyzed the existing observation data of SMC X-1 by the RXTE telescope (around 10 days) and found that PBH as 100% of dark matter is close to but not yet excluded. Lastly, future longer observation of this source by x-ray telescopes with larger effective areas such as AstroSat, Athena, Lynx, and eXTP can potentially close the last mass window where PBHs can make up all of dark matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-91: Novel Epitaxial Silicon Array for Quality Assurance in Photon and Proton Therapy

Purpose: to demonstrate suitability of a novel silicon array for measuring the dose properties of highly conformal photon and proton beams. Methods: prototype under test is a 24cm long linear array prototype, although the underlying technology is suitable to construct 2D arrays as well. It is based on a 64pixels monolithic sensor with 1mm pixel pitch, made of epitaxial ptype silicon. Thanks to design modularity, more sensors can be placed side by side without breaking pixel pitch. Flattened and unflattened photon beams, as well as proton radiation from a cyclotron in pencil beam scanning mode, were considered. Measurements of beam characteristics as percentage depth doses, dose profiles, output factors and energy response, which are necessary to deliver radiation with high precision and reliability, were performed. Results: Dose rate independence with photons was verified in the dose per pulse range 0.03 to 2mGy. Results clearly indicate nondependence of the detector sensitivity both for flattened and unflattened beams, with a variation of at most 0.5percentage. OFs were obtained for field with a lateral size ranging from 0.8cm to 16cm and the results are in good agreement with ion chamber A1SL, max difference less than 1.5percentage. Field sizes and beam penumbra were measured and compared to EBT film results. Concerning proton beams, sensitivity independence on dose rate was verified by changing the beam current in the interval 2-130Gy/s. Field sizes and beam penumbra measurements are in agreement with data taken with a scintillating 2D array with 0.5mm resolution IBA Lynx, and a better penumbra definition than an array of ionization chambers IBA MatriXX is reached. Conclusion: The device is a novel and valuable tool for QA both for photon and proton dose delivery. All measurements demonstrated its capability to measure with high spatial resolution many crucial properties of the RT beam.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-153: Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water

Purpose: Eclipse proton Monte Carlo AcurosPT 13.7 was commissioned and experimentally validated for an IBA dedicated PBS nozzle in water. Topas 1.3 was used to isolate the cause of differences in output and penumbra between simulation and experiment. Methods: The spot profiles were measured in air at five locations using Lynx. PTW-34070 Bragg peak chamber (Freiburg, Germany) was used to collect the relative integral Bragg peak for 15 proton energies from 100 MeV to 225 MeV. The phase space parameters (σx, σθ, ρxθ) number of protons per MU, energy spread and calculated mean energy provided by AcurosPT were identically implemented into Topas. The absolute dose, profiles and field size factors measured using ionization chamber arrays were compared with both AcurosPT and Topas. Results: The beam spot size, σx, and the angular spread, σθ, in air were both energy-dependent: in particular, the spot size in air at isocentre ranged from 2.8 to 5.3 mm, and the angular spread ranged from 2.7 mrad to 6 mrad. The number of protons per MU increased from ∼9E7 at 100 MeV to ∼1.5E8 at 225 MeV. Both AcurosPT and TOPAS agree with experiment within 2 mm penumbra difference or 3% dose difference for scenarios including central axis depth dose and profiles at two depths in multi-spot square fields, from 40 to 200 mm, for all the investigated single-energy and multi-energy beams, indicating clinically acceptable source model and radiation transport algorithm in water. Conclusion: By comparing measured data and TOPAS simulation using the same source model, the AcurosPT 13.7 was validated in water within 2 mm penumbra difference or 3% dose difference. Benchmarks versus an independent Monte Carlo code are recommended to study the agreement in output, filed size factors and penumbra differences. This project is partially supported by the Varian grant under the master agreement between University of Pennsylvania and Varian.

60 APPLIED LIFE SCIENCES↗

TListSpectrum

TListSpectrum is a C++ class developed inside the CERN high-energy physics analysis C++ framework ROOT. This class structure was developed to assist in the processing, visualization, and analysis of list-mode or time-stamped radiation spectroscopy data. The class structure currently contains parsing and functionality to synthesize list-mode data from CAEN and Mirion Lynx radiation spectroscopy digital acquisition systems along with feature functionality to post-process data sets and build coincident data sets from the instrument.

Pierson, Bruce↗