Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low-background detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An Explorer-Class Astrobiology Mission

In this paper we describe a potential new Explorer-class space mission, the AstroBiology Explorer (ABE), consisting of a relatively modest dedicated space observatory having a 50 cm aperture primary mirror which is passively cooled to T less than 65 K, resides in a low-background orbit (heliocentric orbit at 1 AU, Earth drift-away), and is equipped with a suite of three moderate order (m approx. 10) dispersive spectrographs equipped with first-order cross-dispersers in an "echellette" configuration and large format (1024xl024 pixel) near- and mid-IR detector arrays cooled by a modest amount of cryogen. Such a system would be capable of addressing outstanding problems in Astrochemistry and Astrophysics that are particularly relevant to Astrobiology and addressable via astronomical observation. The observational program of this mission would make fundamental scientific progress in each of the key areas of the cosmic history of molecular carbon, the distribution and chemistry of organic compounds in the diffuse and dense interstellar media, and the evolution of ices and organic matter in young planetary systems. ABE could make fundamental progress in all of these areas by conducting an approximately one year mission to obtain a coordinated set of infrared spectroscopic observations over the 2.5-20 micrometers spectral range at spectral resolutions of R greater than or equal to 1000 of approximately 1000 galaxies, stars, planetary nebulae, and young star planetary systems.

Sandford, Scott↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

Toward a DM Search with Phonon-Mediated MKID Devices at NEXUS

To continue the search for dark matter (DM) into the sub-GeV mass range, the development and characterization of new detectors with sub-eV thresholds is critical. Microwave Kinetic Inductance Detectors (MKIDs) offer an attractive architecture for novel microcalorimeters with the requisite energy resolution and threshold for probing DM down to the fermionic thermal relic mass limit of a few keV. A phonon-sensitive MKID device featuring an aluminum resonator patterned onto a silicon substrate has been operating at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. Currently, our estimate of the energy resolution of this device is limited by the efficiency for phonons produced via particle interactions in the substrate to propagate to the superconductor and break Cooper pairs. In this poster, I will present our constraints on the substrate-superconductor coupling and the progress on an absolute energy calibration performed by exposing the rear of the substrate to a pulsed source of 470 nm photons. I will also review the current status and next steps of the phonon-mediated MKID effort at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

The Forward Physics Facility at the High-Luminosity LHC

High energy collisions at the High-Luminosity Large Hadron Collider (LHC) produce a large number of particles along the beam collision axis, outside of the acceptance of existing LHC experiments. The proposed Forward Physics Facility (FPF), to be located several hundred meters from the ATLAS interaction point and shielded by concrete and rock, will host a suite of experiments to probe standard model (SM) processes and search for physics beyond the standard model (BSM). In this report, we review the status of the civil engineering plans and the experiments to explore the diverse physics signals that can be uniquely probed in the forward region. FPF experiments will be sensitive to a broad range of BSM physics through searches for new particle scattering or decay signatures and deviations from SM expectations in high statistics analyses with TeV neutrinos in this low-background environment. High statistics neutrino detection will also provide valuable data for fundamental topics in perturbative and non-perturbative QCD and in weak interactions. Experiments at the FPF will enable synergies between forward particle production at the LHC and astroparticle physics to be exploited. We report here on these physics topics, on infrastructure, detector, and simulation studies, and on future directions to realize the FPF’s physics potential.

47 OTHER INSTRUMENTATION↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

The performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0.3 to 3 deg is presented. The system represents a collaborative effort combining a low-background 1-m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3, 6, 9, and 12/cm (90, 180, 270, and 360 GHz). The telescope has been flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of about 0.00001 with detectors operated at 0.3 K.

Fischer, M. L.↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

We report the performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0 deg 3 min to 3 deg. The system represents a collaborative effort combining a low-background 1 m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3 (90), 6 (180), 9 (270), and 12 (360) cm(exp -1) (GHz). The telescope was flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of Delta(T)/T(sub CMB) is approximately equal to 10(exp -5) with detectors operated at T = 0.3 K.

Fischer, M. L.↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

High-Sensitivity X-ray Polarimetry with Amorphous Silicon Active-Matrix Pixel Proportional Counters

Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout

Black, J. K.↗

CubeSats for Gamma-Ray Astronomy [Book Chapter]

After many years of flying in space primarily for educational purposes, CubeSats – tiny satellites with form factors corresponding to arrangements of “1U” units, or cubes, each 10 cm on a side – have come into their own as valuable platforms for technology advancement and scientific investigations. CubeSats offer comparatively rapid, low-cost access to space for payloads that can be built, tested, and operated by relatively small teams, with substantial contributions from students and early career researchers. Continuing advances in compact, low-power detectors, readout electronics, and flight computers have now enabled X-ray and gamma-ray sensing payloads that can fit within the constraints of CubeSat missions, permitting in-orbit demonstrations of new techniques and innovative high-energy astronomy observations. Gamma-ray-sensing CubeSats are certain to make an important contribution in the new era of multi-messenger, time-domain astronomy by detecting and localizing bright transients such as gamma-ray bursts, solar flares, and terrestrial gamma-ray flashes; however, other astrophysical science areas requiring long observations in a low-background environment, including gamma-ray polarimetry, studies of nuclear lines, and measurement of diffuse backgrounds, will likely benefit as well. Here we present the primary benefits of CubeSats for high-energy astronomy, highlight the scientific areas currently or soon to be studied, and review the missions that are currently operating, under development, or proposed. A rich portfolio of CubeSats for gamma-ray astronomy already exists, and the potential for a broad range of creative and scientifically productive missions in the near future is very high.

79 ASTRONOMY AND ASTROPHYSICS↗

Erratum: Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.

99 GENERAL AND MISCELLANEOUS↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Counting facilities at the Black Hills Underground Campus

The Black Hills Underground Campus (BHUC) houses a low background counting facility on the 4850’ level of the Sanford Underground Research Facility (SURF) with ~4300 m w.e. of rock overburden. Currently there are five ultra-low-background, high-purity germanium detectors operating inside of a class-1,000 cleanroom at the Davis Campus, with a sixth anticipated to be installed within a year. Here, a robust nitrogen purge system and on-site personnel assistance allow these detectors to run continuously to support groups that need low background counting of materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗

Evidence for ground-state electron capture of K 40

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches—including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for potassium-40, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The existence of this decay mode impacts several fields, while theoretical predictions span an order of magnitude. Here we report on the first, successful observation of this rare decay mode, obtained by the KDK (potassium decay) Collaboration using a novel combination of a low-threshold x-ray detector surrounded by a tonne-scale, high-efficiency γ -ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ( I EC 0 ) over excited-state ones ( I EC * ) of I EC 0 / I EC * = 0.0095 ± stat 0.0022 ± sys 0.0010 (68% CL), with the null hypothesis rejected at 4 σ [Stukel et al. , Phys. Rev. Lett. 131 , 052503 (2023) ]. In terms of branching ratio, this unambiguous signal yields I EC 0 = 0.098 % ± stat 0.023 % ± sys 0.010 % , roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves our understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. For example, a shell-model based theoretical estimate for the neutrinoless double-beta decay half-life of calcium-48 is increased by a factor of 7 - 2 + 3 . Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioactivity-in-materials lead for nEXO (Final Scientific Report)

Abstract, introduction, and summary of work completed and products produced by DOE award SC002466. Primary products were six peer-reviewed publications and two PhD theses. This award also supported the operation of an underground HPGe detector and several radioassay measurements: one in a stand alone publication in Phys. Rev. C and the others in an upcoming nEXO radioassay summary paper. The nEXO collaboration aims to demonstrate the Majorana nature of the neutrino by observing the neutrinoless double-beta decay of 136 Xe with a next-generation experiment. The University of Kentucky nEXO group (UKY) operates a world-leading ultra-low-background γ-ray spectrometer as part of the nEXO radioactive background control R&D effort. The nEXO project is a proposed ton-scale neutrinoless double-beta decay experiment. The UKY PI is leading the radioactivity content assessment for all materials required by the nEXO project. As a subset of this task, UKY is also responsible for project-wide management of all low-background γ-ray spectrometry measurements; material assays with these types of instruments, together with ICP-MS, neutron-activation-analysis, and α-spectrometry, are critical to ensuring that the nEXO project can achieve its design sensitivity

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗

Development of the Nano-HEB Array for Low-Background Far-IR Applications

We present an overview of the recent progress made in the development of a far-IR array of ultrasensitive hot-electronnanobolometers (nano-HEB) made from thin titanium (Ti) films. We studied electrical noise, signal and noisebandwidth, single-photon detection, optical noise equivalent power (NEP), and a microwave SQUID (MSQUID) basedfrequency domain multiplexing (FDM) scheme. The obtained results demonstrate the very low electrical NEP down to1.5x10-(sup 2)? W/Hz(sup 1)/(sup 2) at 50 mK determined by the dominating phonon noise. The NEP increases with temperature as ~ T(sup 3)reaching ~ 10-(sup 1)? W/Hz(sup 1)/(sup 2) at the device critical temperature TC = 330-360 mK. Optical NEP = 8.6x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 357mK and 1.4x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 100 mK respectively, agree with thermal and electrical data. The optical couplingefficiency provided by a planar antenna was greater than 50%. Single 8-?m photons have been detected for the first timeusing a nano-HEB operating at 50-200 mK thus demonstrating a potential of these detectors for future photon-countingapplications in mid-IR and far-IR. In order to accommodate the relatively high detector speed (~ ?s at 300 mK, ~ 100 ?sat 100 mK), an MSQUID based FDM multiplexed readout with GHz carrier frequencies has been built. Both the readoutnoise ~ 2 pA/Hz(sup 1)/(sup 2) and the bandwidth > 150 kHz are suitable for nano-HEB detectors.

single-photon↗