Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

Abstract—Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems to reduce transmission losses and improve grid flexibility. LF-HVac system employs back-to-back (BTB) converters to interconnect and control the voltage and power interchange between two power grid operating at different frequencies. While there are multiple studies on LF-HVac system in the literature, the fault clearing method in the LF-HVac system has not been analyzed. Therefore, this paper focuses on fault clearing operation in LFHVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained by using the proposed method substantially diminish the fault current.

Kim, Woosung↗

Iterative multi-task learning and inference from seismic images

Seismic interpretation aims to extract quantitative and interpretable attributes from a seismic image produced using some migration method to inform characteristics of a subsurface reservoir or target of interest. Current paradigms for computing seismic attributes mostly rely on single-task algorithms. We develop an iterative, multi-task machine learning method to learn and infer multiple attributes from a seismic image. This method is composed of two stages: a multi-task inference stage and a multi-modal, multi-task refinement stage. The basic mechanism of this method is that we train a multi-task inference neural network (NN) to estimate a set of attributes, including a relative geological time (RGT), a denoised higher-resolution (DHR) seismic image, and multiple fault attributes (including probability, dip, and strike), from a low-resolution, noisy seismic image; then we input the inferred attributes to a multi-task refinement NN to enhance the raw inference results iteratively. The two multi-task NNs are trained separately based on synthetic seismic images and associated attributes generated by a geological modeling algorithm. The software we intend to release is a PyTorch implementation of this multi-task learning method for both 2D and 3D cases along with scripts to run the training/validation. The algorithm and software can be a useful tool for automatic seismic interpretation.

Gao, Kai↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Decomposition of high-rank factorized unitary coupled-cluster operators using ancilla and multiqubit controlled low-rank counterparts

The factorized form of the unitary coupled-cluster (UCC) approximation is one of the most promising methodologies to prepare trial states for strongly correlated systems within the variational quantum eigensolver framework. The factorized form of the UCC Ansatz can be systematically applied to a reference state to generate the desired entanglement. The difficulty associated with such an approach is the requirement of simultaneously entangling a growing number of qubits, which quickly exceeds the hardware limitations of today's quantum machines. In particular, while circuits for singles and double excitations can be performed on current hardware, higher-rank excitations require too many gate operations. In this work, we propose a set of schemes that trade off using extra qubits for a reduced gate depth to decompose high-rank UCC excitation operators into significantly lower depth circuits. These results will remain useful even when fault-tolerant machines are available to reduce the overall state-preparation circuit depth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DEEPEN 3D PFA Index Models for Exploration Datasets at Newberry Volcano

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), index models needed to be developed to map values in geoscientific exploration datasets to favorability index values. This GDR submission includes those index models. Index models were created by binning values in exploration datasets into chunks based on their favorability, and then applying a number between 0 and 5 to each chunk, where 0 represents very unfavorable data values and 5 represents very favorable data values. To account for differences in how exploration methods are used to detect each play component, separate index models are produced for each exploration method for each component of each play type. Index models were created using histograms of the distributions of each exploration dataset in combination with literature and input from experts about what combinations of geophysical, geological, and geochemical signatures are considered favorable at Newberry. This is in attempt to create similar sized bins based on the current understanding of how different anomalies map to favorable areas for the different types of geothermal plays (i.e., conventional hydrothermal, superhot EGS, and supercritical). For example, an area of partial melt would likely appear as an area of low density, high conductivity, low vp, and high vp/vs. This means that these target anomalies would be given high (4 or 5) index values for the purpose of imaging the heat source. To account for differences in how exploration methods are used to detect each play component, separate index models are produced for each exploration method for each component of each play type. Index models were produced for the following datasets: - Geologic model - Alteration model - vp/vs - vp - vs - Temperature model - Seismicity (density*magnitude) - Density - Resistivity - Fault distance - Earthquake cutoff depth model

15 GEOTHERMAL ENERGY↗

Operation and control of hybrid HVDC system with LCC and full-bridge MMC connected in parallel

In this study, a new kind of hybrid high-voltage direct current (HVDC) system is proposed. Each terminal of the proposed system consists of one line commutated converter (LCC) and one full-bridge modular multilevel converter (FB-MMC). The LCC and FB-MMC are connected in parallel so that they can share the same transmission line. The active–reactive power capability of the hybrid HVDC system is extended compared with the conventional LCC-HVDC system, and power reversal control without power interruption can be achieved by the coordination control of LCC and FB-MMC. Besides, the proposed hybrid HVDC system is capable of handling DC fault, because both LCC and FB-MMC have DC fault blocking capability. Moreover, the power rating of FB-MMC can be designed to low value while keeping the bulk-power transmission capability of LCC. A two-terminal bipolar hybrid HVDC system is built in PSCAD/EMTDC. The simulation results verify the effectiveness and feasibility of the proposed hybrid topology and corresponding control strategies.

42 ENGINEERING↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenge Solutions for a Significant Water Cut Reduction History Match on Heavy Oil Polymer EOR

Milne Point Field is conducting the first-ever active polymer flood pilot program designed to enhance oil recovery (EOR) of heavy oils on the Alaska North Slope (ANS). The experimental field program consists of two pairs of horizontal injection and production wells deployed in an isolated fault block in the Schrader Bluff reservoir. The EOR method combines polymer flooding and low salinity water flooding to improve recovery. Prior average water cut reduction in polymer EOR fields ordinarily ranges between 10% to 15% for most light oil and heavy oil reservoirs. When comparing other field applications, the long-lasting (24 months) and much lower water cut poses a challenge for numerical history matching when applying typical simulation methods. This abstract discusses two practical new approaches used for history matching of the long-lasting ultralow water cut. These new applications include 1) multiple relative permeability curves with J-function incorporation with low endpoints of relative permeability of water (Krw). This approach integrated the permeability differential adjustment in the geometries of horizontal and vertical directions based on geological review. 2) A specific permeability channel strips along with the horizontal or vertical planar assumption. The current history matching results indicate success in achieving an excellent agreement with the field observed low water-cut.

Namie, S.↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Newly acquired core enhances geologic understanding of the northern Paradox Basin Cane Creek play, southeastern Utah

The Cane Creek interval is an emerging unconventional heterolithic play within the Pennsylvanian Paradox Formation of the northern Paradox Basin, southeastern Utah. Structural controls (basement uplifts, salt movement, faults, fractures) likely control production from the Cane Creek, where total oil production of ~10 MMBO is just a fraction of current estimates of the undiscovered resource (up to 1.2 BBOE). Oil production has been most successful from unstimulated horizontal wells in the Cane Creek Unit in the central play area, whereas areas to the north (Greentown and Gunnison Valley) have to date proven to be largely unproductive from vertical and horizontal wells drilled without the benefit of 3D seismic or the deployment of modern hydraulic fracturing techniques. However, the limited historical drilling has shown significant promise (e.g., significant shows). The lack of core data in the northern part of the play has impeded thorough assessment of reservoir quality, character, and lithological facies heterogeneity. The Cane Creek is informally divided into three distinct zones. The upper A and basal C zones are composed of fabric destructive and wavy bedded anhydrite, dolomitic mudstone, and organic-rich algal laminated mudstones (source rock). The middle B zone is generally wave rippled and burrowed, low-permeability sandstone-siltstone (reservoir) with subordinate displacive anhydrite. Recent potash cores collected from the Salt Valley anticline near Crescent Junction, Utah (but east of the main play area), show thicker reservoir sandstone/siltstone packages (~40 ft) in the B zone, and parts of the C zone, in the northern part of the Paradox Basin in comparison to the central (~35 ft) and southern (~30 ft) areas. Source rock analyses from northern core/cuttings also indicate that it is well positioned within the oil window (VRo ~0.8), with thin organic-rich mudstone beds containing up to 20 wt% TOC. Because the siliciclastic reservoir rocks have low permeabilities (0.009–0.202 mD) and variable porosities (6–17%) due to dolomite-anhydrite cement, naturally occurring and possibly stimulated fractures may be essential for hydrocarbon recovery. To better understand the northern part of the Cane Creek play, a new core was obtained from the research stratigraphic well State 16-2 (January 2021). Details from this new core will help characterize reservoir quality via core analyses, petrography, fracture orientations, geomechanics, and correlation of facies and depositional trends. Additionally, an evaluation of matrix porosity/permeability will be conducted to determine its contribution to productivity.

02 PETROLEUM↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Search for 3D topological superconductors using laser-based spectroscopy (Final Technical Report)

The three-dimensional topological superconductor (3D TSC) is a novel quantum phase of matter that is predicted to exhibit exotic thermal and electrical properties, which may serve applications ranging from precision thermal management and sensing technologies to fault-tolerant quantum information processing. Over the past decade, there has been an intensive effort to realize 1D and 2D TSCs by artificially engineering them from combinations of already existing materials. For example, coupling conventional superconductors to spin-orbit coupled 1D nanowires or to 2D topological insulator surfaces by the proximity effect provides a route to realizing 1D and 2D TSCs respectively. However no artificial engineering strategy is available for a 3D TSC. Therefore, current searches are limited to intrinsically superconducting compounds whose topological properties are difficult to predict. The overarching goal of this project was to realize and to identify 3D TSCs in bulk single crystals using novel laser-based spectroscopic techniques. One major thrust was to develop ultralow temperature and ultra-high-resolution angle-resolved photoemission spectroscopy (ARPES) to directly measure the dispersion of Majorana excitations that are predicted to exist on the surfaces of 3D TSCs. Another major thrust was to develop a rational route to realize 3D TSCs by identifying their precursor phases. It is theoretically proposed that the critical fluctuations of certain ordered electronic phases can mediate Cooper pairing in odd-parity channels and lead to topological superconductivity. Therefore, 3D TSCs may potentially emerge upon suppressing these inversion symmetry broken precursor phases to a critical point with external perturbations such as pressure, strain or even light. To test this hypothesis, we studied candidate materials using a suite of symmetry-sensitive optical probes including rotational anisotropy optical second harmonic generation (RA-SHG) and time-resolved coherent phonon spectroscopy, all operable under high-pressure and low temperature environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

What can the GRACE seasonal cycle tell us about lake-aquifer interactions?

Lake-aquifer interactions have been the subject of investigation and debate for decades. Traditional investigation methods include measurement of water flux across the groundwater-surface water interface, application of heat and environmental tracer methods, conducting numerical simulations of the water flow, and mass balance-based approaches. We first review, evaluate and describe the different approaches that have been applied for examining lake-aquifer interactions and propose an additional complementary approach. While the leakage from lakes and its slow movement through porous media (laminar flow) is well characterized by existing methods, modeling the rapid and turbulent flow through preferred pathways (faults/karst) remains a challenging task. To better understand the nature, and the full scale, of the lake aquifer interactions, and using Lake Nasser and the underlying Dakhla subbasin of the Nubian Sandstone Aquifer System (NSAS) in the Western Desert of Egypt (area: 0.66 x 10 6 km 2 ) as a test site, we examine, model, and correlate temporally and spatially, the variations in Gravity Recovery and Climate Experiment terrestrial water storage (GRACE TWS ) solutions, with precipitation, lake levels, area, and water volume. We review current GRACE applications in hydrology and present our novel approach. Findings include: firstly, large seasonal fluctuations (peak: Nov./Dec.; trough: July/Aug.) in Lake Nasser's surface water levels (average annual fluctuations: from 3.7 m to 7.5 m), area (average area: 3622 km 2 but up to 4530 km 2 ), and volume (annual average: 13.4 km 3 , and up to 34 km 3 ) are observed throughout years 2006 to 2015. These fluctuations are accompanied by an increase in GRACE TWS (average: 50 ± 13 mm/yr, up to 77 ± 18 mm/yr) over Lake Nasser and by a progression of a front of increasing GRACE TWS values (> 50 ± 13 mm) away from the lake reaching distances of up to 700 km some 3 to 5 months following peak lake level periods. The areas witnessing the seasonal increase in GRACE TWS display a progressive increase in phase and decrease in amplitude with distance from the lake. Secondly, the negligible precipitation over the Dakhla subbasin cannot account for the observed seasonal GRACE TWS patterns and neither can the leakage signal from Lake Nasser. Thirdly, overall similarities in the distribution of GRACE TWS seasonal spatial patterns are observed. During high lake level periods (e.g., Dec. 2007; Feb. 2015) additional, and more distant, areas from Lake Nasser saw increases in GRACE TWS and vice versa during low lake level periods (e.g., July 2006; Aug. 2010). These observations are consistent with Lake Nasser being the main source of modern recharge for the Dakhla subbasin and suggest a new conceptual model for the subbasin: a slow groundwater flow through a porous matrix and a rapid groundwater flow along a network of faults, fractures, and karst topography across the matrix. We suggest that the proposed conceptual model for the interaction between Lake Nasser and the Dakhla subbasin could be applicable to aquifers of similar geologic, climatic, and hydrologic settings worldwide and that approaches similar to those advocated here could be used to investigate the validity of this suggestion.

54 ENVIRONMENTAL SCIENCES↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗