Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NONTHERMALLY DOMINATED ELECTRON ACCELERATION DURING MAGNETIC RECONNECTION IN A LOW-β PLASMA

By means of fully kinetic simulations, we investigate electron acceleration during magnetic reconnection in a nonrelativistic proton–electron plasma with conditions similar to solar corona and flares. We demonstrate that reconnection leads to a nonthermally dominated electron acceleration with a power-law energy distribution in the nonrelativistic low-β regime but not in the high-β regime, where β is the ratio of the plasma thermal pressure and the magnetic pressure. The accelerated electrons contain most of the dissipated magnetic energy in the low-β regime. A guiding-center current description is used to reveal the role of electron drift motions during the bulk nonthermal energization. We find that the main acceleration mechanism is a Fermi-type acceleration accomplished by the particle curvature drift motion along the electric field induced by the reconnection outflows. Although the acceleration mechanism is similar for different plasma β, low-β reconnection drives fast acceleration on Alfvénic timescales and develops power laws out of thermal distribution. The nonthermally dominated acceleration resulting from magnetic reconnection in low-β plasma may have strong implications for the highly efficient electron acceleration in solar flares and other astrophysical systems.

79 ASTRONOMY AND ASTROPHYSICS↗

A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac

Purpose: The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. Methods: VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code, was used to model the Linac treatment head components. Particles were propagated through the lower portion of the treatment head using BEAMnrc. Dose distributions and spectral distributions were calculated using DOSXYZnrc and BEAMdp, respectively. For validation, 6 MV flattened and flattening filter free (FFF) photon beams were generated and compared to measurement for square fields, 10 and 40 cm wide and at d{sub max} for diagonal profiles. Two low-Z targets were investigated: a 2.35 MeV carbon target and the proposed 2.50 MeV commercial imaging target for the TrueBeam platform. A 2.35 MeV carbon target was also simulated in a 2100EX Clinac using BEAMnrc. Contrast simulations were made by scoring the dose in the phosphor layer of an IDU20 aSi detector after propagating through a 4 or 20 cm thick phantom composed of water and ICRP bone. Results: Measured and modeled depth dose curves for 6 MV flattened and FFF beams agree within 1% for 98.3% of points at depths greater than 0.85 cm. Ninety three percent or greater of points analyzed for the diagonal profiles had a gamma value less than one for the criteria of 1.5 mm and 1.5%. The two low-Z target photon spectra produced in TrueBeam are harder than that from the carbon target in the Clinac. Percent dose at depth 10 cm is greater by 3.6% and 8.9%; the fraction of photons in the diagnostic energy range (25–150 keV) is lower by 10% and 28%; and contrasts are lower by factors of 1.1 and 1.4 (4 cm thick phantom) and 1.03 and 1.4 (20 cm thick phantom), for the TrueBeam 2.35 MV/carbon and commercial imaging beams, respectively. Conclusions: VirtuaLinac is a promising new tool for Monte Carlo modeling of novel target designs. A significant spectral difference is observed between the low-Z target beam on the Clinac platform and the proposed imaging beam line on TrueBeam, with the former providing greater diagnostic energy content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-state disks and low-beta disks

Stellar black hole candidates (BHCs) exhibit bimodal spectral states. We calculate nonthermal disk spectra, demonstrating that a large photon index (alpha (sub x) approximately 2-3) observed in the soft (high) state is due to a copious soft photon supply, whereas soft photon starvation leads to a smaller index (alpha (sub x) approximately 1.5-2) in the hard (low) state. Thus, the absence of the soft component flux in the low state cannot be due to obscuration. A possible disk configuration during the low state is discussed. We proposed that a low-state disk may be a low-beta disk in which magnetic pressure may exceed gas pressure becuase of the suppression of field escape by a strong shear. As a result, disk material will take the form of blobs constricted by mainly toroidal magnetic fields. Fields are dissipated mainly by occasional reconnection events with a huge energy release. This will account for large-amplitude, aperiodic X-ray variations (flickering) and high-energy radiation with small alpha(sub x) from hard state BHCs and possibly from active galactic nuclei. Further, we propose a hysteretic relation between the mass-flow rate and plasma-beta, a ratio of gas pressure to magnetic pressure, for the spectral evolution of transient BHCs. The disk is in the low-beta state in quiescence and early rise. The low-beta disk is optically thin and affected by advection. A hard-to-soft transition occurs before the peak luminosity, since there is no advection-dominated branch at higher luminosities. An optically thick, high-beta disk appears at small radii. In the decay phase of the light curve, the standard-type disk becomes effectively optically thin, when a soft-hard transition is triggered. High-beta plasmas in the main body shrink to form minute blobs, and low-beta coronal plasma fills interblob space.

Mineshige, Shin↗

From Low-Cost Sensors to High-Quality Data: A Review of Challenges and Summary of Best Practices for Effectively Using Low-Cost Particulate Matter Mass Sensors

Low-cost sensors for particulate matter mass (PM) enable spatially dense, high temporal resolution measurements of air quality that traditional reference monitoring cannot. Low-cost PM sensors are especially beneficial in low and middle-income countries where few, if any, reference grade measurements exist and in areas where the concentration fields of air pollutants have significant spatial gradients. Unfortunately, low-cost PM sensors also come with a number of challenges that must be addressed if their data products are to be used for anything more than a qualitative characterization of air quality. The various PM sensors used in low-cost monitors are all subject to biases and calibration dependencies, corrections for which range from relatively straightforward(e.g. meteorology, age of sensor) to complex (e.g. aerosol source, composition, refractive index). The methods for correcting and calibrating these biases and dependencies that have been used in the literature likewise range from simple linear and quadratic models to complex machine learning algorithms. Here we review the needs and challenges when trying to get high-quality data from low-cost sensors. We also present a set of best practices to follow to obtain high-quality data from these low-cost sensors.

low-cost sensors↗

Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with low- to intermediate-risk prostate cancer. Patient selection criteria for consideration of cryotherapy and brachytherapy are similar in terms of anesthesia candidacy. Therefore, cryotherapy would not be recommended as a first-line local therapy for this particular patient subset.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control of low-mode drive asymmetry in an efficient long-pulse low gas-fill density Hohlraum

Laser-driven Hohlraums filled with gas at lower densities (<0.6 mg/cc) have higher efficiency compared to original ≥ 0.96 mg/cc fill because of reduced backscatter losses [Hall et al., Phys. Plasmas 24, 052706 (2017)]. However, using low-density filled Hohlraums with longer drive required for lower adiabat implosions, and hence potentially higher inertial confinement fusion gain designs, has been challenging since the Hohlraum wall blow-off is less tamped, thus altering the laser beam absorption regions and drive symmetry. A series of NIF experiments using optimized pulse shaping, beam pointing, and temporal phasing have demonstrated, through imaging of the Hohlraum and capsule dynamics, that a symmetric implosion using a 14-ns low-adiabat drive pulse {2× longer than high-density-carbon ablator designs using low gas-fill density Hohlraums [Divol et al., Phys. Plasmas 24, 056309 (2017)]} is possible in a low backscatter loss 0.45 mg/cc He-filled Hohlraum. The ingress of the Hohlraum walls was mitigated by revisiting the adiabat-shaped design [Clark et al., Phys. Plasmas 21, 112705 (2014)] that uses a low-power (1 TW) trough that delays the wall expansion. Low-mode P 2 and P 4 drive asymmetry swings caused by the drift of the laser spots were essentially zeroed out by employing temporal beam phasing between cones of beams [Turner et al., Phys. Plasmas 7, 333 (2000)]. So the results also indicate an improved coupling efficiency of ~30% compared to an earlier design using higher density filled Hohlraums and pave the way for revisiting low-adiabat, high convergence drives using CH ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transients using low-high pulsed power in inductively coupled plasmas

Pulsed inductively coupled plasmas (ICPs) are widely deployed in the fabrication of semi-conductor devices. Pulse repetition frequencies (PRFs) of up to tens of kHz are commonly used during plasma etching for the high power densities they generate during the pulse-on period, and for their unique chemistries during the pulse-off period. The use of highly attaching halogen gases produces low electron densities during the pulse-off period, and these low density can result in instabilities, E-H transitions and ignition delays when applying power on the next pulse. To mitigate these possibilities, a low-level power environment could be maintained during “pulse-off” to moderate the minimum plasma density, therefore reducing ignition delays and enhancing plasma stability. In this work, ICPs sustained by 5 kHz pulsed power using Ar/Cl 2 mixtures at 20 mTorr were computationally investigated. For these conditions, the computed electron temperature (T e ) reaches a quasi-steady state during both the high- and low-power excitation. The model predicts that within the electromagnetic skin-depth, T e spikes to a high value during a low-to-high power modulation, and to a low value during a high-to-low power modulation. At the same time, a few cm above the substrate, there is little modulation in T e , as electron power convected from the skin depth disperses in traversing the reactor. Finally, the positive and negative spikes, and convection of transients across the reactors, are functions of power ramping time and gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of correlated states and optimization of nuclear reactions for low-energy particles at nonresonant low-frequency modulation of a potential well

A method for the formation of correlated coherent states of low-energy particles in a parabolic potential well owing to the full-scale low-frequency modulation ω(t) = ω{sub 0}sinΩt of the parameters of this well has been considered. It has been shown that such a modulation in the absence of a stochastic force acting on a particle results in the fast formation of correlated coherent states and in an increase in the correlation coefficient and transparency of the potential barrier to the limiting values vertical bar r(t) vertical bar {sub max} → 1 and D → 1. The presence of the stochastic force significantly affects the evolution of correlated coherent states, decreasing the rate of an increase in the correlation coefficient vertical bar r(t) vertical bar {sub max} (at Ω ≤ 10{sup −4}ω{sub 0}) and limiting it at the level vertical bar r(∞) vertical bar {sub max} < 1 (at Ω = (0.001–0.1)ω{sub 0}); vertical bar r(∞) vertical bar {sub max} increases with a decrease in the frequency of modulation and decreases with an increase in the intensity of the stochastic force. It has been shown that, at a realistic relation between the parameters, low-frequency modulation can ensure such vertical bar r vertical bar {sub max} value that the transparency of the potential barrier for low-energy particles increases by a factor of 10{sup 50}–10{sup 100} or larger. The mechanism of the formation of correlated coherent states for charged particles in a gas or a low-pressure plasma placed in a low-frequency magnetic field has been considered. We have determined the relation between the magnetic field strength and modulation frequency, as well as the relation between the temperature and density of the gas (plasma), at which the method under consideration can be used to optimize nuclear reactions at low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.

low noise↗

Fabrication of Low-Tortuosity Ultrahigh-Area-Capacity Battery Electrodes through Magnetic Alignment of Emulsion-Based Slurries

High energy–density, low–cost batteries are critically important to a variety of applications ranging from portable electronics to electric vehicles (EVs) and grid–scale storage. While tremendous research effort has been focused on new materials or chemistries with high energy–density potential, design innovations such as low–tortuosity thick electrodes are another promising path toward higher energy density and lower cost. Growing demand for fast–charging batteries has also highlighted the need for negative electrodes that can accept high rate charging without metal deposition; low tortuosity can be a benefit in this regard. However, a general and scalable fabrication method for low–tortuosity electrodes is currently lacking. Here an emulsion–based, magnetic–alignment approach to producing thick electrodes (>400 µm thickness) with ultrahigh areal capacity (up to ≈14 mAh cm –2 vs 2–4 mAh cm –2 for conventional lithium ion) is reported. The process is demonstrated for LiCoO 2 and meso–carbon microbead graphite. The LiCoO 2 cathodes are confirmed to have low tortuosity via DC–depolarization experiments and deliver high areal capacity (>10 mAh cm –2 ) in galvanostatic discharge tests at practical C–rates and model EV drive–cycle tests. Lastly, this simple fabrication method can potentially be applied to many other active materials to enable thick, low–tortuosity electrodes.

25 ENERGY STORAGE↗

Low-Background Gamma Spectrometry for the International Monitoring System

PNNL has developed two very low-background gamma detectors housed in a new shallow underground laboratory. This new capability significantly improves our ability to detect trace amounts of airborne particulate that may be present in samples from the IMS field stations. The detectors were custom ordered to be fabricated using very low background materials. The combination of cosmic veto panels, dry nitrogen gas to reduce radon, low background shielding, and the shallow underground laboratory results in a reduction of the background count rate by a factor of 100 compared to an off –the-shelf commercial gamma detector operating above ground at our laboratory. Detection limits are thus reduced an order of magnitude.

gamma specgtroscopy, lo↗

Coupling of Methane to Ethane, Ethylene and Aromatics over Nickel on Ceria-Zirconia at Low Temperatures

Methane is converted over nickel on ceria zirconia (Ni/CZ) to ethane, aromatics and hydrogen at steady state up to the thermodynamic limit at temperatures of 350 oC to 500 oC. At 450 oC and 500 oC, traces of ethylene are also produced. Ni/NiO particles activate methane and couple the resulting surface species to hydrocarbon products. Large Ni particles are responsible for the formation of carbonaceous deposits. In addition, aromatics are formed on these sites. Smaller Ni/NiO particles are responsible for the formation of ethane and ethylene and appear to provide sustained activity. On these sites, surface species couple into higher alkyl chains, which can be desorbed as ethane. It is suggested that these Ni sites are too small to assemble aromatic deposits and hence, they remain active throughout the reaction.

Okolie, Chukwuemeka↗