At least 91 records · Page 5

Optimizing the location and configuration of disaster resilience hubs under transportation and electric power network failures

Natural disasters often result in failures of transportation network components and blackouts that imperil the wellbeing of vulnerable populations. In response to these events, resilience hubs have been proposed as a pre-disaster planning strategy to improve access to critical services. This paper introduces an optimization-based approach to locate and configure electric power-generating resilience hubs considering the possibility of failures in transportation and electric power systems. The model's objective is to identify hub locations and configurations that maximize transportation accessibility to the hubs and maximize the satisfaction of basic energy needs through hub-generated electric power. Besides a budget constraint, the model accounts for limits on the levels of hub energy generation vis-à-vis community energy demands, and on the transportation network distance of communities to hubs. Three heuristics are presented for the proposed planning problem. The first heuristic is a genetic algorithm (GA) with problem-specific solution generation procedures. The other two heuristics implement greedy search techniques. Numerical experiments were conducted, using data from rural Puerto Rico, to illustrate the application of the proposed model and heuristics, and examine their performance. In the numerical experiments, the GA heuristic found better solutions than the greedy heuristics. Additionally, design solutions consisting of spatially dispersed hubs with low energy generation capacity were better than solutions with spatially concentrated high-capacity hubs. Lastly, across a wide range of hub demand scenarios, only a small number of candidate hub locations consistently ranked among the best locations for establishing a hub.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗

Forced Oscillation Source Location in Power Systems Using MVMD-assisted DEF in TF Plane

Fast and accurate forced oscillation source location (FOSL) is critical for mitigating forced oscillations in power systems. Here, to overcome the shortcomings of traditional dissipating energy flow (DEF) in decomposing the forced oscillation components from the measurement responses, a multivariate variational mode decomposition (MVMD)-assisted FOSL is proposed in this paper to locate the forced oscillation sources from measurements in time-frequency (TF) plane. The multi-channel measurement matrix of each generator is formed, then the multi-channel modes are decomposed from the formed multi-channel measurement matrix using the MVMD. Further, the intrinsic mode functions (IMFs) associated with the forced oscillation mode are distinguished from the decomposed modes according to the relative energy weights. With the distinguished IMFs, the MVMD-assisted DEF calculation method is developed to locate the forced oscillation source. Finally, the performance of the proposed method is evaluated using the simulation data of the WECC 179-bus test system and IEEE-NASPI Oscillation Source Location Contest as well as the actual PMU data of ISO New England. The results validated the effectiveness and accuracy of the proposed method in the FOSL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Series Classification for Locating Forced Oscillation Sources

Here, this article presents a machine learning based time-series classification method for using synchrophasor measurements to locate the source of forced oscillation (FO) for fast disturbance removal. First, multivariate time series (MTS) matrices are constructed by the most informative measurements selected by sequential feature selection from each power plant. Then, the Mahalanobis matrix is trained such that the Mahalanobis distance between the MTSs from the same class (i.e., with the same FO source location) are minimized and from different classes (i.e., with different FO source locations) are maximized. This allows MTSs to be classified by classifiers with class membership corresponding to the location of each FO source. To meet the runtime requirements of online matching, class templates are constructed to reduce data size and improve matching efficiency. To account for uncertainty in identifying the exact beginning of an FO event, dynamic time warping is used to align the out-of-sync MTSs. IEEE 39bus and WECC 179bus systems are used for algorithm development and validation. Simulation results demonstrate that the algorithm meets online operation runtime requirement with high accuracy using misaligned data sets.

42 ENGINEERING↗

Integrated Framework of Multisource Data Fusion for Outage Location in Looped Distribution Systems

Accurate outage location is essential for expediting post-outage power restoration, minimizing outage duration, and enhancing the resilience of distribution networks. With the advent of advanced metering infrastructure, data-driven outage location methods have significantly advanced beyond traditional approaches that rely on manual inspections. However, existing methods still face critical challenges, like reliance on single-source data, limited ability to handle partially observable systems or difficulties with loop networks. To the best of our knowledge, no single approach has comprehensively addressed all of these challenges at once. To this end, this paper proposes a comprehensive multisource data fusion framework for outage locations via probabilistic graph networks. The framework consists of three key phases. First, a novel method for reconstituting distribution networks with loops is developed, transforming looped networks into multiple radial subnetworks that retain all outage causalities of the original network. Second, Bayesian network (BN) models are established for each subnetwork, integrating multiple data sources and network structures. Finally, a joint Gibbs sampling mechanism, featuring forward and backward information flow, is designed to merge data from separate BN models and maximize the utilization of limited evidence, ensuring accurate outage location identification. In conclusion, the framework was validated on two modified public test systems, and comparative studies confirmed its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CHESS 2025: Location data for field observations and sampling

This dataset represents geolocation data associated with field observations and sampling from the Colorado Headwaters Ecological Spectroscopy Study (CHESS) during June and July of 2025. Location data were collected using Trimble DA2 Global Navigation Satellite System (GNSS) receivers with Trimble Catalyst 2 centimeter (cm) positioning service and the Environmental Systems Research Institute (Esri) Field Maps mobile app. Files in this data package include meadow site polygons, shrub site polygons, tree site polygons and stem point locations, and Leaf Area Index (LAI) plot polygons (.geojson). The geojson files can be opened with open-source GIS software (e.g, QGIS). A csv file is also provided with point coordinates for all locations. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

A general spatial-temporal framework for short-term building temperature forecasting at arbitrary locations with crowdsourcing weather data

Weather forecasting has been a critical component to predict and control building energy consumption for better building energy management. Without accessibility to other data sources, the onsite observed temperatures or the airport temperatures are used in forecast models. In this paper, we present a novel approach by utilizing the crowdsourcing weather data from neighboring personal weather stations (PWS) to improve the weather forecast accuracy around buildings using a general spatial-temporal modeling framework. The final forecast is based on the ensemble of local forecasts for the target location using neighboring PWSs. Our approach is distinguished from existing literature in various aspects. First, we leverage the crowdsourcing weather data from PWS in addition to public data sources. In this way, the data is at much finer time resolution (e.g., at 5-minute frequency) and spatial resolution (e.g., arbitrary location vs grid). Second, our proposed model incorporates spatial-temporal correlation information of weather variables between the target building and a set of neighboring PWSs so that underlying correlations can be effectively captured to improve forecasting performance. Here, we demonstrate the performance of the proposed framework by comparing to the benchmark models on temperature forecasting for a building located at an arbitrary location at San Antonio, Texas, USA. In general, the proposed model framework equipped with machine learning technique such as Random Forest can improve forecasting by 50% compares with persistent model and has 90% chance to outperform airport forecast in short-term forecasting. In a real-time setting, the proposed model framework can provide more accurate temperature forecasting results compared with using airport temperature forecast for most forecast horizon. Moreover, we analyze the sensitivity of model parameters to gain insights on how crowdsourcing data from the neighboring personal weather stations impacts forecasting performance. Finally, we implement our model in other cities such as Syracuse and Chicago to test the model's performance in different landforms and climate types.

54 ENVIRONMENTAL SCIENCES↗

Effects of cluster expansion on the locations of phase transition boundary as a first step to quantify uncertainty in first principles statistical mechanics framework

Predicting phase diagrams from first principle calculations eliminates the need of tedious experimental trials and errors. Fully automating first principle phase diagram calculations without any sort of human intervention has been a long daunting task and troubling scientific communities for decades. This grand problem remains not fully resolved, largely due to the vastly high-dimensional parameter space associated with density functional theory, cluster expansion, lattice Monte Carlo, and the substantial uncertainty propagating through a set of complex simulations. As a first step to tackle this grand problem, we reported a first demonstration of how sensitive phase boundary locations can be to various cluster expansion fittings and input DFT training data. To the best knowledge of the authors, this study reported the first ever attempt to quantify uncertainty in first principles statistical mechanics framework. In addition, a semi-automated phase transition detection algorithm has been devised in this paper to deal with the associated statistical errors and uncertainties from Monte Carlo method and its predecessor DFT calculations and cluster expansions. This algorithm has been applied in a classical cluster expansion Mg-Cd binary alloy system to detect phase transitions at various locations of phase diagram using different cluster expansions to demonstrate its predictive power and quantify uncertainties. The results suggested that using Chebyshev basis function shifted the transition locations toward the dilute solid solution phase and expanded the phase stability of concentrated ordered phases to wider composition range. The addition of perturbed defect configurations into training data set lowered the order-disorder transition temperature to be away from true transition temperature, suggesting the transition nature is indeed configurational disorder dominated rather than defect assisted. Finally, we found that the weighting has negligible effect on the transition locations, except for the case of using Chebyshev basis function to fit all non-weighted configurations that can be susceptible to Monte Carlo sampling hysteresis.

36 MATERIALS SCIENCE↗

An algorithm to locate the centers of baryon acoustic oscillations

The cosmic structure formed from baryon acoustic oscillations (BAO) in the early universe is imprinted in the galaxy distribution observable in large-scale surveys and is used as a standard ruler in contemporary cosmology. Typically, BAOs are detected as a preferential length scale in two-point statistics, which gives little information about the location of the BAO structures in real space. The aim of the algorithm described in this paper is to find probable centers of BAOs in the cosmic matter distribution. The algorithm convolves the three-dimensional distribution of matter density with a spherical shell kernel of variable radius placed at different locations. The locations that correspond to the highest values of the convolution correspond to the probable centers of BAOs. This method is realized in an open-source, computationally efficient algorithm. Here, we describe the algorithm and present the results of applying it to the SDSS DR9 CMASS survey and associated mock catalogs. A detailed performance study demonstrates the ability of the algorithm to locate BAO centers and in doing so presents a novel detection of the BAO scale in galaxy surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Setting the H-mode pedestal structure: variations of particle source location using gas puff and pellet fueling

Experiments in DIII-D show that a particle source location inside the top of the H-mode pedestal (pellets) maintains a higher pedestal pressure than an edge source (gas fueling) through a widening of the electron temperature pedestal with reduction of the temperature gradient. The effect of these two fueling schemes on the H-mode pedestal structure was examined in DIII-D by comparing controlled pellet-fueled and gas-fueled discharges across a fueling scan up to 40 torr 1 s –1 . High resolution electron profiles reveal that gas fueling lowers the pedestal pressure as the density profile shifts radially outwards and the separatrix density increases, while pellet fueling maintains a constant pedestal pressure. The neutral source locations from pellets and gas are determined with the PELLET and UEDGE codes, respectively, and quantify the particle source localization. Pellets provide significant ionization inside the pedestal top while gas puffing localizes ionization in the scrape-off-layer and pedestal foot, broadly consistent with the density profile structure influenced by the source. ELMs are observed to increase in frequency and reduce impurity content as fueling is increased. Stability analysis with ELITE shows that both conditions are near the type-I ELM corner of the peeling–ballooning stability diagram, which is altered significantly by the introduction of pellets. Since transport mechanisms are not observed to change substantially with particle source location, wider pedestals allow the pellet-fueled discharges to retain higher pedestal temperatures at similar pedestal densities. EPED1 is tested to capture the pedestal pressure, under-predicting the height with pellets and over-predicting the height with gas by ~15%. Overall, these results have important implications for future reactors where pellet fueling will be the primary particle source due to an opaque scrape-off-layer by showing that the neutral source location plays a role in setting the structure of the H-mode pedestal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techno-economic assessment of electricity market potential for co-located hydro-floating PV systems

Abstract—Harnessing renewable energy from diverse sources is paramount for sustainable power systems. Recently, co-located floating PV (FPV) systems present an intriguing prospect in this context. These hybrid systems, blending hydro and solar power, may offer a more consistent electricity output and potential economic advantages. Yet, assessing their actual potential requires a comprehensive techno-economic assessment. In addition, probabilistic price forecasting has recently gained attention in electricity market because decisions based on such predictions can yield significantly higher profits than those made with point forecasts alone. To this end, this paper embarks on a journey to elucidate the electricity market potential of co-located hydro-FPV systems in a probabilistic fashion to investigate the technological merits and economic viability of co-located hydro-FPV under different market structures. Our preliminary findings suggest that LCOE and payback metrics are sensitive not only to different markets but also to different solar incentives. Concurrently, we also observe that the payback period is generally faster with a production tax credit (PTC) than an investment tax credit (ITC). This assessment serves as a cornerstone for understanding the future prospects of co-located hydro-FPV systems in modern electricity markets.

13 HYDRO ENERGY↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Location Generalizer

This software produces general location descriptions from time-series location data collected from mobile devices that record global positioning system (GPS) coordinates over time. The purpose of this software is to convert detailed location history data, which is considered personally identifiable information (PII), into non-traceable, anonymized, generic information that is useful to researchers but does not contain PII. The software is specifically designed for use with trigger-based data that describe the parked locations and dwell times of automobiles.

Smart, John↗

Transcatheter Arterial Chemoembolization for Treatment-Naive Hepatocellular Carcinoma Has Different Treatment Effects Depending on Central or Peripheral Tumor Location

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3–24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3–12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0–12.6) in the central arm and up-to-7 in, and 3.0 months (1.2–4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

Gastroenterology & Hepatology↗

Machine Learning Approach for Spatiotemporal Multivariate Optimization of Environmental Monitoring Sensor Locations

Abstract Long-term environmental monitoring is critical for managing the soil and groundwater at contaminated sites. Recent improvements in state-of-the-art sensor technology, communication networks, and artificial intelligence have created opportunities to modernize this monitoring activity for automated, fast, robust, and predictive monitoring. In such modernization, it is required that sensor locations be optimized to capture the spatiotemporal dynamics of all monitoring variables as well as to make it cost-effective. The legacy monitoring datasets of the target area are important to perform this optimization. In this study, we have developed a machine-learning approach to optimize sensor locations for soil and groundwater monitoring based on ensemble supervised learning and majority voting. For spatial optimization, Gaussian process regression (GPR) is used for spatial interpolation, while the majority voting is applied to accommodate the multivariate temporal dimension. Results show that the algorithms significantly outperform the random selection of the sensor locations for predictive spatiotemporal interpolation. While the method has been applied to a four-dimensional dataset (with two-dimensional space, time, and multiple contaminants), we anticipate that it can be generalizable to higher-dimensional datasets for environmental monitoring sensor location optimization.

Siddiquee, Masudur R.↗

Selection of Well Locations for Saturated Zone Monitoring at the E-Area Low Level Waste Facility

Savannah River Site (SRS) has adopted a revised approach to performance monitoring of the E- Area Low Level Waste Facility (ELLWF) that adds a saturated zone component to the existing vadose zone monitoring program (Kubilius, 2019). The revised monitoring approach specifies that eight additional water table wells be installed near Slit Trench 1 (ST1) and Engineered Trench 2 (ET2). Six wells will be installed at locations characterized in 2017 and 2018. These include four wells near ET2 (ELF001D, ELF002D, ELF003D, and ELF004D) at locations identified by Kubilius (2019) and two wells north of ST1 (ELF005D and ELF006D) at locations finalized in this report. Additionally, two wells (ELF007D and ELF008D) are to be installed at locations south of ST1 based on characterization work completed in 2020 and documented in this report. This area is near well cluster BGX-2 between the Mixed Waste Management Facility (MWMF) and the ELLWF. The area is upgradient of ELLWF and, contamination in the water table aquifer is sourced from MWMF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗