Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Aerodynamic Forces and Moments on a Large Ogive-Cylinder Store at Various Locations Below the Fuselage Center Line of a Swept-Wing Bomber Configuration at a Mach Number of 1.61

A supersonic wind-tunnel investigation on store interference has been conducted in the Langley 4- by 4-foot supersonic pressure tunnel at a Mach number of 1.61. Forces and moments were measured on a large ogive-cylinder store in the presence of a 45 deg swept-wing-fuselage bomber configuration for a number of store locations below the fuselage center line. Results of the investigation show that large variations of store lift, drag, and pitch occur with changes in store or airplane angle of attack, store vertical location, and store horizontal location. The variation of the store forces and moments with respect to the chordwise location of the wing plan form indicates that the wing is a large factor in producing the interference loads on the store. Comparison of data for underfuselage and underwing store locations at an angle of attack of 0 deg showed maximum store drag interferences of similar magnitudes, but showed considerably smaller maximum interference on store lift an pitching moments for underfuselage store locations.

SUPERSONIC FLIGHT↗

Study of advanced system for position location and navigation

Concepts are investigated for improving location precision and system capacity relative to current satellite based data collection and location systems. The TRILOC concept provides either or both improvements in location and system capacity by utilizing three measurements acquired during a single transmission from a platform for location purposes. The location algorithm is developed, and range differences are measured onboard the satellite. An error analysis then relates platform location errors to the precision with which the measurements are made. The second concept is to increase system capacity by means of directive antennas onboard the satellite for reducing interference and/or reducing platform power. The potential advantages and disadvantages of both sweeping and fixed directive antennas for random access systems are evaluated.

Source record↗

The sensitivity of fracture location distribution in brittle materials

The Weibull weak-link theory allows for the computation of distribution functions for both the fracture location and the applied far-field stress. Several authors have suggested using the fracture location information from tests to infer Weibull parameters, and others have used the predictive capabilities of the theory to calculate average fracture locations for brittle bodies. By a simple set of example calculations, it is shown that the fracture location distribution function is distinctly more sensitive to perturbations in the stress state than the fracture stress distribution function is. In general, the average fracture location is more subject to stress perturbations than the average fracture stress. The results indicate that care must be exercised in applying fracture location theory.

Wetherhold, Robert C.↗

GIS modeling of archaeological site locations: A low-tech approach

A Geographic Information System (GIS)-type analysis of archaeological site locations using a dBase III plus program and a desk top computer is presented. A previously developed model of site locations in the Sequatchie Valley of northeastern Alabama is tested against known site locations in another large survey area there. The model fails to account for site locations in the test area. A model is developed for the test area and indicates the site locations are indeed different. Whether this is due to differences in site locations on a sub-regional level, or to sample error in the original model is unknown.

Futato, Eugene M.↗

Development of an accurate transmission line fault locator using the global positioning system satellites

A highly accurate transmission line fault locator based on the traveling-wave principle was developed and successfully operated within B.C. Hydro. A transmission line fault produces a fast-risetime traveling wave at the fault point which propagates along the transmission line. This fault locator system consists of traveling wave detectors located at key substations which detect and time tag the leading edge of the fault-generated traveling wave as if passes through. A master station gathers the time-tagged information from the remote detectors and determines the location of the fault. Precise time is a key element to the success of this system. This fault locator system derives its timing from the Global Positioning System (GPS) satellites. System tests confirmed the accuracy of locating faults to within the design objective of +/-300 meters.

Lee, Harry↗

The Locations of Gamma-Ray Bursts Measured by Comptel

The COMPTEL instrument on the Compton Gamma Ray Observatory is used to measure the locations of gamma-ray bursts through direct imaging of MeV photons. In a comprehensive search, we have detected and localized 29 bursts observed between 1991 April 19 and 1995 May 31. The average location accuracy of these events is 1.25 deg (1 sigma), including a systematic error of approx. 0.5 deg, which is verified through comparison with Interplanetary Network (IPN) timing annuli. The combination of COMPTEL and IPN measurements results in locations for 26 of the bursts with an average "error box" area of only approx. 0.3 deg (1 sigma). We find that the angular distribution of COMPTEL burst locations is consistent with large-scale isotropy and that there is no statistically significant evidence of small-angle autocorrelations. We conclude that there is no compelling evidence for burst repetition since no more than two of the events (or approx. 7% of the 29 bursts) could possibly have come from the same source. We also find that there is no significant correlation between the burst locations and either Abell clusters of galaxies or radio-quiet quasars. Agreement between individual COMPTEL locations and IPN annuli places a lower limit of approx. 100 AU (95% confidence) on the distance to the stronger bursts.

Kippen, R. Marc↗

The Error Distribution of BATSE Gamma-Ray Burst Locations

Empirical probability models for BATSE gamma-ray burst (GRB) location errors are developed via a Bayesian analysis of the separations between BATSE GRB locations and locations obtained with the Interplanetary Network (IPN). Models are compared and their parameters estimated using 392 GRBs with single IPN annuli and 19 GRBs with intersecting IPN annuli. Most of the analysis is for the 4Br BATSE catalog; earlier catalogs are also analyzed. The simplest model that provides a good representation of the error distribution has 78% of the probability in a "core" term with a systematic error of 1.85 deg and the remainder in an extended tail with a systematic error of 5.1 deg, which implies a 68% confidence radius for bursts with negligible statistical uncertainties of 2.2 deg. There is evidence for a more complicated model in which the error distribution depends on the BATSE data type that was used to obtain the location. Bright bursts are typically located using the CONT data type, and according to the more complicated model, the 68% confidence radius for CONT-located bursts with negligible statistical uncertainties is 2.0 deg.

Briggs, Michael S.↗

Improved Method of Locating Defects in Wiring Insulation

An improved method of locating small breaches in insulation on electrical wires combines aspects of the prior dielectric withstand voltage (DWV) and time-domain reflectometry (TDR) methods. The method was invented to satisfy a need for reliably and quickly locating insulation defects in spacecraft, aircraft, ships, and other complex systems that contain large amounts of wiring, much of it enclosed in structures that make it difficult to inspect. In the DWV method, one applies a predetermined potential (usually 1.5 kV DC) to the wiring and notes whether the voltage causes any arcing between the wiring and ground. The DWV method does not provide an indication of the location of the defect (unless, in an exceptional case, the arc happens to be visible). In addition, if there is no electrically conductive component at ground potential within about 0.010 in. (approximately equal to 0.254 mm) of the wire at the location of an insulation defect, then the DWV method does not provide an indication of the defect. Moreover, one does not have the option to raise the potential in an effort to increase the detectability of such a defect because doing so can harm previously undamaged insulation. In the TDR method as practiced heretofore, one applies a pulse of electricity having an amplitude of less than 25 V to a wire and measures the round-trip travel time for the reflection of the pulse from a defect. The distance along the wire from the point of application of the pulse to the defect is then calculated as the product of half the round-trip travel time and the characteristic speed of a propagation of an electromagnetic signal in the wire. While the TDR method as practiced heretofore can be used to locate a short or open circuit, it does not ordinarily enable one to locate a small breach in insulation because the pulse voltage is too low to cause arcing and thus too low to induce an impedance discontinuity large enough to generate a measurable reflection. The present improved method overcomes the weaknesses of both the prior DWV and the prior TDR method.

Greulich, Owen R.↗

A Probabilistic, Facility-Centric Approach to Lightning Strike Location

A new probabilistic facility-centric approach to lightning strike location has been developed. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision~ith spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.

Huddleston, Lisa L.↗

Method for the Absolute Calibration of the Location and Orientation of Large-Format Detectors Using Laser Radar

A method of mapping pixel locations of a detector array includes measuring a location on the detector array, initiating a frame readout of the detector array, measuring a location of one or more metrology targets on the detector array, analyzing the frame readout to identify a pixel at the location on the detector array, and defining a location of the identified pixel with respect to the location of the one or more metrology targets. Subsequent measurement of the metrology targets alone by another metrology system allows one to infer the six degree of freedom alignment of the detector array in space.

Coulter, Phillip↗

Robotic External Leak Locator (RELL) Leak Plume Field Detection on the International Space Station (ISS)

The Robotic External Leak Locator (RELL) was deployed to the International Space Station (ISS) with the objective of demonstrating the ability to detect and locate small leaks. On-orbit operations began in late November 2016 and following scanning activities to characterize the natural and induced environment of the ISS, RELL focused on the United States External Active Thermal Control System (EATCS). RELL successfully detected ammonia related to a known small ammonia leak in the port-side EATCS, with the highest pressure values around the inboard Radiator Beam Valve Module 1 (RBVM 1). An additional day of scanning was subsequently performed in December 2017 to focus on RBVM 1. RELL was approved for additional external operations in February 2017 with the goal of fine tuning the location of the leak. Using grid scanning patterns, RELL detected ammonia around RBVM 1 and located the approximate source of the leak. The potential leak site was inspected by a crew member during an Extravehicular Activity (EVA) in March 2017, and the suspected radiator-side lines were isolated from the port-side EATCS coolant loop in April 2017. Subsequent monitoring of the system pressures showed that the leak has stopped, indicating RELL accurately located the source of the EATCS leak. These activities verify that RELL enhances the ISS Program's ability to not only locate small leaks, but isolate the source with minimal impact to the entire ISS system.

External Active Thermal Control System↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin L Hunt↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin Hunt↗

Regional Modeling and Simulation for Vertiport Location Assessment

There is increasing interest in the Urban Air Mobility concept and the realization of electric Vertical Take-Off and Landing (e-VTOL) vehicles flying in the National Airspace System. NASA, FAA, and the industry are investigating various aspects of this new mode of transportation for cargo and humans. There are significant challenges in making this mode a reality, including feasibility, safety, infrastructure, traffic management, public acceptance, and scalability. From the infrastructure perspective, one of the aspects that needs to be addressed is the location of vertiports (named similar to heliports, for vertical take-off and landing vehicles). There is significant on-going research for selecting location of vertiports. However, the locations are largely based on demand models. Also, these efforts are focused in specific local regions, San Francisco/Bay Area, Chicago, Tampa, etc. This talk presents an approach to determine the location of vertiports in regional areas (across the United States), incorporating the desire to have certain attributes closer to or further from the location using a regional modeling tool. The feasibility of flying e-VTOL vehicles between various vertiport locations is also presented using a mobility operations simulation tool.

Air Mobility↗

Multisource Data Fusion Outage Location in Distribution Systems via Probabilistic Graphical Models

Efficient outage location is critical to enhancing the resilience of power distribution systems. However, accurate outage location requires combining massive evidence received from diverse data sources, including smart meter (SM) last gasp signals, customer trouble calls, social media messages, weather data, vegetation information, and physical parameters of the network. This is a computationally complex task due to the high dimensionality of data in distribution grids. In this paper, we propose a multi-source data fusion approach to locate outage events in partially observable distribution systems using Bayesian networks (BNs). A novel aspect of the proposed approach is that it takes multi-source evidence and the complex structure of distribution systems into account using a probabilistic graphical method. Our method can radically reduce the computational complexity of outage location inference in high-dimensional spaces. The graphical structure of the proposed BN is established based on the network’s topology and the causal relationship between random variables, such as the states of branches/customers and evidence. Utilizing this graphical model, accurate outage locations are obtained by leveraging a Gibbs sampling (GS) method, to infer the probabilities of de-energization for all branches. Compared with commonly-used exact inference methods that have exponential complexity in the size of the BN, GS quantifies the target conditional probability distributions in a timely manner. As a result, a case study of several real-world distribution systems is presented to validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering

The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD). Locating the positions of these partial discharges would help repair the transformer to prevent failures. This work investigates algorithms that could be deployed to locate the position of a PD event using data from ultra-high frequency (UHF) sensors inside the transformer. These algorithms typically proceed in two steps: first determining the signal arrival time, and then locating the position based on time differences. This paper reviews available methods for each task and then propose new algorithms: a convolutional iterative filter with thresholding (CIFT) to determine the signal arrival time and a reference table of travel times to resolve the source location. The effectiveness of these algorithms are tested with a set of laboratory-triggered PD events and two sets of simulated PD events inside transformers in production use. Tests show the new approach provides more accurate locations than the best-known data analysis algorithms, and the difference is particularly large, 3.7X, when the signal sources are far from sensors.

47 OTHER INSTRUMENTATION↗

Simulated effect of defect volume and location on very high cycle fatigue of laser beam powder bed fused AlSi10Mg

This study quantifies the interaction between volumetric defect location and size on the very high cycle fatigue (VHCF) of laser beam powder bed fused (LB-PBF) AlSi10Mg. Crystal plasticity finite element method (CPFEM) simulations were used to investigate the effects of defect location and size on the driving force for crack initiation. The CPFEM model was calibrated against uniaxial and cyclic experimental data of LB-PBF AlSi10Mg. Defect characteristics were informed by experimental data from the specimens produced in various geometries to create realistic representative volume elements (RVEs) with equivalent volume fractions of defects. By embedding defects of varying sizes and locations within the RVEs, fatigue indicator parameters (FIPs) were calculated to analyze the impact of defects’ characteristics on fatigue performance. Different combinations of defect volume and locations were generated for various microstructure instantiations, providing insight into extreme value fatigue responses. Larger defect volumes located on free surfaces consistently generated the highest FIPs, suggesting defect size and boundary proximity intensify stress concentration effects. RVEs with multiple smaller defects produced lower FIPs than those with single large critical defects. These findings underscore the critical role of defect characteristics on fatigue life, providing a foundation for future predictive modeling in fatigue-sensitive AM applications.

AlSi10Mg↗