Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LUTETIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

99m Tc-, 90 Y-, and 177 Lu-Labeled Iron Oxide Nanoflowers Designed for Potential Use in Dual Magnetic Hyperthermia/Radionuclide Cancer Therapy and Diagnosis

Development of a complex based on iron oxide nanoparticles (IONPs) for diagnosis and dual magnetic hyperthermia/radionuclide cancer therapy accomplishing high yields of radiolabeling and great magnetic heat induction is still a challenge. We report here the synthesis of citric acid, poly(acrylic acid) (PAA) and poly(ethylene glycol) coated IONPs and their labeling with three radionuclides, namely, technetium (99mTc), yttrium (90Y), and lutetium (177Lu), aiming at potential use in cancer diagnosis and therapy. Polyol-synthesized IONPs are a flowerlike structure with 13.5 nm spherically shaped cores and 24.8 nm diameter. PAA-coated nanoparticles (PAA@IONP) showed the best characteristics such as easy radiolabeling with very high yields (>97.5%) with all three radionuclides, and excellent in vitro stabilities with less than 10% of radionuclides detaching after 24 h. Heating ability of PAA@IONP in an alternating external magnetic field showed intrinsic loss power value of 7.3 nH m2/kg, which is one of higher reported values. Additionally, PAA@IONP itself presented no significant cytotoxicity to the CT-26 cancer cells, reaching IC50 at 60 μg/mL. However, under the external magnetic field, they show hyperthermia-mediated cells killing, which correlated with the magnetic field strength and time of exposure. Since PAA@IONP are easy to prepare, biocompatible, and with excellent magnetic heat induction, these nanoparticles radiolabeled with high-energy beta emitters 90Y and 177Lu have valuable potential as agent for dual magnetic hyperthermia/radionuclide therapy, while radiolabeled with 99mTc could be used in diagnostic imaging. Copyright © 2019 American Chemical Society.

60 APPLIED LIFE SCIENCES↗

Rapid Microwave Preparation of Highly Efficient Ce[superscript 3+]-Substituted Garnet Phosphors for Solid State White Lighting

Ce{sup 3+}-substituted aluminum garnet compounds of yttrium (Y{sub 3}Al{sub 5}O{sub 12}) and lutetium (Lu{sub 3}Al{sub 5}O{sub 12}) - both important compounds in the generation of (In,Ga)N-based solid state white lighting - have been prepared using a simple microwave heating technique involving the use of a microwave susceptor to provide the initial heat source. Carbon used as the susceptor additionally creates a reducing atmosphere around the sample that helps stabilize the desired luminescent compound. High quality, phase-pure materials are prepared within a fraction of the time and using a fraction of the energy required in a conventional ceramic preparation; the microwave technique allows for a reduction of about 95% in preparation time, making it possible to obtain phase pure, Ce{sup 3+}-substituted garnet compounds in under 20 min of reaction time. It is estimated that the overall reduction in energy compared with ceramic routes as practiced in the lab is close to 99%. Conventionally prepared material is compared with material prepared using microwave heating in terms of structure, morphology, and optical properties, including quantum yield and thermal quenching of luminescence. Finally, the microwave-prepared compounds have been incorporated into light-emitting diode 'caps' to test their performance characteristics in a real device, in terms of their photon efficiency and color coordinates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Asymptotically-Equal-To 10 eV ionization shift in Ir K{alpha}{sub 2} from a near-coincident Lu K-edge

Close to an x-ray filter's K-edge the transmission depends strongly on the photon energy. For a few atom pairs, the K-edge of one is only a few tens of eV higher than a K-line energy of another, so that a small change in the line's energy becomes a measurable change in intensity behind such a matching filter. Lutetium's K-edge is Asymptotically-Equal-To 27 eV above iridium's K{alpha}{sub 2} line, Asymptotically-Equal-To 63.287 keV for cold Ir. A Lu filter reduces this line's intensity by Asymptotically-Equal-To 10 % when it is emitted by a plasma, indicating an ionization shift {Delta}E Asymptotically-Equal-To 10{+-}1 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-coincident K-line and K-edge energies as ionization diagnostics for some high atomic number plasmas

For some high atomic number atoms, the energy of the K-edge is tens of eVs higher than the K-line energy of another atom, so that a few eV increase in the line's energy results in a decreasing transmission of the x-ray through a filter of the matching material. The transmission of cold iridium's Asymptotically-Equal-To 63.287 keV K{alpha}{sub 2} line through a lutetium filter is 7% lower when emitted by ionized iridium, consistent with an energy increase of {Delta}{epsilon} Asymptotically-Equal-To 10{+-}1 eV associated with the ionization. Likewise, the transmission of the K{beta}{sub 1} line of ytterbium through a near-coincident K-edge filter changes depending on plasma parameters that should affect the ionization. Systematic exploration of filter-line pairs like these could become a unique tool for diagnostics of suitable high energy density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intrinsic magnetic properties of hexagonal LuFeO{sub 3} and the effects of nonstoichiometry

We used oxide molecular-beam epitaxy in a composition-spread geometry to deposit hexagonal LuFeO{sub 3} (h-LuFeO{sub 3}) thin films with a monotonic variation in the Lu/Fe cation ratio, creating a mosaic of samples that ranged from iron rich to lutetium rich. We characterized the effects of composition variation with x-ray diffraction, atomic force microscopy, scanning transmission electron microscopy, and superconducting quantum interference device magnetometry. After identifying growth conditions leading to stoichiometric film growth, an additional sample was grown with a rotating sample stage. From this stoichiometric sample, we determined stoichiometric h-LuFeO{sub 3} to have a T{sub N} = 147 K and M{sub s} = 0.018 μ{sub B}/Fe.

36 MATERIALS SCIENCE↗

Low valency in lanthanides: A theoretical study of NdF and LuF

The ground and low-lying excited state potential energy curves of neodymium monofluoride were calculated using multireference (CASSCF) and single reference (EOM-CR-CCSD(T)) methods. Optimized bond lengths were obtained and accurate bond dissociation energies were computed. The EOM-CR-CCSD(T) method was used to determine the bond dissociation energy of lutetium monofluoride, and it is shown that core correlation is required to produce bond dissociation energies in agreement with experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication and characterization of spark plasma sintered Ce:LuAG ceramic for scintillation application

Rare earth Cerium doped Lutetium Aluminum Garnet (Ce:LuAG) ceramics are widely used as phosphor material in medical imaging and high-energy physics. Due to its technological importance, an attempt has been made to fabricate Ce:LuAG ceramics by using spark plasma sintering (SPS) technique. XRD patterns of SPS sintered Ce:LuAG ceramics reveals a mixed LuAG and CeO{sub 2} (antisite defect) phases. The microstructures of SPS sintered Ce:LuAG ceramics shows limited densification, inappropriate compaction of particles and existence of residual pores, voids between the grain boundaries affects the transparency of Ce:LuAG ceramics. Relative density and hardness of post sintered Ce:LuAG ceramic is also determined. The effect of Ce{sup 3+} doping concentration and sintering temperature on optical luminescence behavior of Ce:LuAG ceramic is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-fast LuI{sub 3}:Ce scintillators for hard x-ray imaging

We have developed ultra-fast cerium-coped lutetium-iodide (LuI{sub 3}:Ce) films thermally evaporated as polycrystalline, structured scintillator using hot wall epitaxy (HWE) method. The films have shown a 13 ns decay compared to the 28 ns reported for crystals. The fast speed coupled with its high density (∼5.6 g/cm{sup 3}), high effective atomic number (59.7), and the fact that it can be vapor deposited in a columnar form makes LuI{sub 3}:Ce an attractive candidate for high frame rate, high-resolution, hard X-ray imaging. In crystal form, LuI{sub 3}:Ce has demonstrated bright (>100,000 photons/MeV) green (540 nm) emission, which is well matched to commercial CCD/CMOS sensors and is critical for maintaining high signal to noise ratio in light starved applications. Here, we report on the scintillation properties of films and those for corresponding crystalline material. The vapor grown films were integrated into a high-speed CMOS imager to demonstrate high-speed radiography capability. The films were also tested at Advanced Photon Source, Argonne National Laboratory beamline 1-ID under hard X-ray irradiation. The data show a factor of four higher efficiency than the reference LuAG:Ce scintillators, high image quality, and linearity of scintillation response over a wide energy range. The films were employed to perform hard X-ray microtomography, the results of which will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient 2-μm laser oscillation of 5% Tm{sup 3+} : KLu(WO{sub 4}){sub 2} disks and 5% Tm{sup 3+} : KLu(WO{sub 4}){sub 2}/KLu(WO{sub 4}){sub 2} composite structures

The spectral and lasing characteristics of active disk elements made of double potassium – lutetium tungstates 5% Tm : KLuW and 5% Tm : KLuW/KLuW composite structures are comparatively studied. Laser power of about 5 W in the cw regime at a wavelength of 1.85 μm was achieved in a composite sample with the active layer thickness of 250 μm. Under quasi-cw pumping, the slope efficiency of all the studied samples exceeded 50%. It is experimentally shown that the internal stresses in the composite structures strongly affect the spectral characteristics of the laser radiation. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small animal simultaneous PET/MRI: initial experiences in a 9.4T microMRI

We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEW HUBBLE SPACE TELESCOPE OBSERVATIONS OF HEAVY ELEMENTS IN FOUR METAL-POOR STARS

Elements heavier than the iron group are found in nearly all halo stars. A substantial number of these elements, key to understanding neutron-capture nucleosynthesis mechanisms, can only be detected in the near-ultraviolet. We report the results of an observing campaign using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope to study the detailed heavy-element abundance patterns in four metal-poor stars. We derive abundances or upper limits from 27 absorption lines of 15 elements produced by neutron-capture reactions, including seven elements (germanium, cadmium, tellurium, lutetium, osmium, platinum, and gold) that can only be detected in the near-ultraviolet. We also examine 202 heavy-element absorption lines in ground-based optical spectra obtained with the Magellan Inamori Kyocera Echelle Spectrograph on the Magellan-Clay Telescope at Las Campanas Observatory and the High Resolution Echelle Spectrometer on the Keck I Telescope on Mauna Kea. We have detected up to 34 elements heavier than zinc. The bulk of the heavy elements in these four stars are produced by r-process nucleosynthesis. These observations affirm earlier results suggesting that the tellurium found in metal-poor halo stars with moderate amounts of r-process material scales with the rare earth and third r-process peak elements. Cadmium often follows the abundances of the neighboring elements palladium and silver. We identify several sources of systematic uncertainty that must be considered when comparing these abundances with theoretical predictions. We also present new isotope shift and hyperfine structure component patterns for Lu II and Pb I lines of astrophysical interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo dose enhancement studies in microbeam radiation therapy

Purpose: A radical radiation therapy treatment for gliomas requires extremely high absorbed doses resulting in subsequent deleterious side effects in healthy tissue. Microbeam radiation therapy (MRT) is an innovative technique based on the fact that normal tissue can withstand high radiation doses in small volumes without any significant damage. The synchrotron-generated x-ray beam is collimated and delivered to an array of narrow micrometer-sized planar rectangular fields. Several preclinical experiments performed at the Brookhaven National Laboratory (BNL) and at the European Synchrotron Radiation Facility (ESRF) confirmed that MRT yields a higher therapeutic index than nonsegmented beams of the same characteristics. This index can be greatly improved by loading the tumor with high atomic number (Z) contrast agents. The aim of this work is to find the high-Z element that provides optimum dose enhancement. Methods: Monte Carlo simulations (PENELOPE/penEasy) were performed to assess the peak and valley doses as well as their ratio (PVDR) in healthy tissue and in the tumor, loaded with different contrast agents. The optimization criteria used were maximization of the ratio between the PVDR values in healthy tissue respect to the PVDR in the tumor and minimization of bone and brain valley doses. Results: Dose enhancement factors, PVDR, and valley doses were calculated for different high-Z elements. A significant decrease of PVDR values in the tumor, accompanied by a gain in the valley doses, was found in the presence of high-Z elements. This enables the deposited dose in the healthy tissue to be reduced. The optimum high-Z element depends on the irradiation configuration. As a general trend, the best outcome is provided by the highest Z contrast agents considered, i.e., gold and thallium. However, lanthanides (especially Lu) and hafnium also offer a satisfactory performance. Conclusions: The remarkable therapeutic index in microbeam radiation therapy can be further improved by loading the tumor with a high-Z element. This study reports quantitative data on several dosimetric magnitudes in order to find the optimum contrast agent. Although the final choice of the element will also depend on possible cytotoxicity, three elements were found to be worthy of mention: gold, thallium, and lutetium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of 11 different radioisotopes for palliative treatment of bone metastases by computational methods

Purpose: Throughout the years, the palliative treatment of bone metastases using bone seeking radiotracers has been part of the therapeutic resources used in oncology, but the choice of which bone seeking agent to use is not consensual across sites and limited data are available comparing the characteristics of each radioisotope. Computational simulation is a simple and practical method to study and to compare a variety of radioisotopes for different medical applications, including the palliative treatment of bone metastases. This study aims to evaluate and compare 11 different radioisotopes currently in use or under research for the palliative treatment of bone metastases using computational methods. Methods: Computational models were used to estimate the percentage of deoxyribonucleic acid (DNA) damage (fast Monte Carlo damage algorithm), the probability of correct DNA repair (Monte Carlo excision repair algorithm), and the radiation-induced cellular effects (virtual cell radiobiology algorithm) post-irradiation with selected particles emitted by phosphorus-32 ({sup 32}P), strontium-89 ({sup 89}Sr), yttrium-90 ({sup 90}Y ), tin-117 ({sup 117m}Sn), samarium-153 ({sup 153}Sm), holmium-166 ({sup 166}Ho), thulium-170 ({sup 170}Tm), lutetium-177 ({sup 177}Lu), rhenium-186 ({sup 186}Re), rhenium-188 ({sup 188}Re), and radium-223 ({sup 223}Ra). Results: {sup 223}Ra alpha particles, {sup 177}Lu beta minus particles, and {sup 170}Tm beta minus particles induced the highest cell death of all investigated particles and radioisotopes. The cell survival fraction measured post-irradiation with beta minus particles emitted by {sup 89}Sr and {sup 153}Sm, two of the most frequently used radionuclides in the palliative treatment of bone metastases in clinical routine practice, was higher than {sup 177}Lu beta minus particles and {sup 223}Ra alpha particles. Conclusions: {sup 223}Ra and {sup 177}Lu hold the highest potential for palliative treatment of bone metastases of all radioisotopes compared in this study. Data reported here may prompt future in vitro and in vivo experiments comparing different radionuclides for palliative treatment of bone metastases, raise the need for the careful rethinking of the current widespread clinical use of {sup 89}Sr and {sup 153}Sm, and perhaps strengthen the use of {sup 223}Ra and {sup 177}Lu in the palliative treatment of bone metastases.

60 APPLIED LIFE SCIENCES↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of LGSO: Ce crystals by the Czochralski method

Single crystals of Lu{sub 2x}Gd{sub 2-2x}SiO{sub 5}: Ce (0 < x < 1) compounds with different atomic ratios Lu/(Lu + Gd) have been grown by the Czochralski method. It has been shown that a change in the spatial symmetry from P2{sub 1}/c to C2/c in the course of substitution of lutetium for gadolinium occurs at the ratio Lu/(Lu + Gd) = 0.1. The lattice thus formed with symmetry C2/c in the structure of Lu{sub 2x}Gd{sub 2-2x}SiO{sub 5}: Ce crystals favors the maximum possible incorporation of Ce{sup 3+} ions into the sevenfold-coordinated position with respect to oxygen. This explains the substantial improvement of the scintillation characteristics of the grown crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vibronic states in organic semiconductors based on non-metal naphthalocyanine. Detection of heterocyclic phthalocyanine compounds in a flexible dielectric matrix

The vibronic properties of semiconductor structures based on non-metal naphthalocyanine molecules are studied using IR and Raman spectroscopy methods. New absorption lines in the transmission spectra of such materials are detected and identified. Three transmission lines are observed in the range 2830-3028 cm{sup -1}, which characterize carbon-hydrogen bonds of peripheral molecular groups. Their spectral positions are 2959, 2906, and 2866 cm{sup -1}. It is detected that the phthalocyanine ring can also exhibit its specific vibronic properties in the Raman spectra at 767, 717, and 679 cm{sup -1}. The naphthalocyanine molecule in the organic dielectric matrix of microfibers is described using IR spectroscopy. It is shown that the set of vibrations characterizing the isoindol group, pyrrole ring, naphtha group, and C-H bonds, allows an accurate enough description of the vibronic states of the naphthalocyanine complex in complex heterostructures to be made. The spectral range with fundamental modes, characterizing a naphthalocyanine semiconductor in a heterostructure, is 600-1600 cm{sup -1}. A comparison of the compositions of complex systems with a similar heterostructure containing lutetium diphthalocyanine demonstrated few errors.

36 MATERIALS SCIENCE↗