Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Observations of the far ultraviolet airflow by the Ultraviolet Limb Imaging experiment on STS-39

The Ultraviolet Limb Imaging (UVLIM) experiment flew on STS-39 in the spring of 1991 to observe the Earth's thermospheric airglow and included a far ultraviolet (1080-1800 A) spectrometer. We present first results from this spectrometer, including a spectroscopic analysis at 6-A resolution of H, O, N, and N2 dayglow emissions and modeling of the observed limb-scan profiles of dayglow emissions. The observed N2 Lyman-Birge-Hopfield (LBH) emission reflects a vibrational population distribution in the a(1 Pi)(sub g) state that differs significantly from those predicted for direct electron excitation and excitation with cascade from the a('1 Sigma)(sub u)(-) and w(1 Delta)(sub u) states. The vibrational population distribution and LBH brightness suggest a total cascade rate 45% that of direct excitation, in contrast to laboratory measurements. For the first time, pronounced limb brightening is observed in both the N I lambda 1200 limb emission profiles, as expected for emissions excited by N2 dissociation which produces kinetically fast N fragments; however, optically thick components of these features are also observed. Preliminary modeling of the OI lambda 1356, HI lambda 1216, and OI lambda 1304 and OI lambda 1641 emissions agrees to within roughly 10% of the observed limb-scan profiles, but the models underestimate the N2 LBH profiles by a factor of 1.4-1.6, consistent with the inferred cascade effect. Other findings include: an OI lambda 1152/lambda 1356 intensity ratio that is inconsistent with the large cascade contribution to OI lambda 1356 from np 5P states required by laboratory and nightglow observations; nightglow observations of the tropical ultraviolet arcs exhibit a wide range of OI lambda 1356/lambda 1304 intensity ratios and illustrate the complicated observing geometry and radiative transfer effects that must be modeled; and we find a 3-sigma upper limit of 8.5 R to the total LBH vehicle glow emission.

Budzien, S. A.↗

Limb congestion enhances the synchronization of sympathetic outflow with muscle contraction

In this report, we examined if the synchronization of muscle sympathetic nerve activity (MSNA) with muscle contraction is enhanced by limb congestion. To explore this relationship, we applied signal-averaging techniques to the MSNA signal obtained during short bouts of forearm contraction (2-s contraction/3-s rest cycle) at 40% maximal voluntary contraction for 5 min. We performed this analysis before and after forearm venous congestion; an intervention that augments the autonomic response to sustained static muscle contractions via a local effect on muscle afferents. There was an increased percentage of the MSNA noted during second 2 of the 5-s contraction/rest cycles. The percentage of total MSNA seen during this particular second increased from minute 1 to 5 of contraction and was increased further by limb congestion (control minute 1 = 25.6 +/- 2.0%, minute 5 = 32.8 +/- 2.2%; limb congestion minute 1 = 29.3 +/- 2.1%, minute 5 = 37.8 +/- 3.9%; exercise main effect <0.005; limb congestion main effect P = 0.054). These changes in the distribution of signal-averaged MSNA were seen despite the fact that the mean number of sympathetic discharges did not increase over baseline. We conclude that synchronization of contraction and MSNA is seen during short repetitive bouts of handgrip. The sensitizing effect of contraction time and limb congestion are apparently due to feedback from muscle afferents within the exercising muscle.

Non-NASA Center↗

ATHLETE Offloader Limb as a High-capacity Crane

A new concept for the NASA Jet Propulsion Laboratory (JPL) All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robotic constructor / mobility system employs tendon-driven actuation of individual limbs, similar to high-capacity cranes in terrestrial work environments. While maintaining mechanical joints that allow each limb to function as a highly dexterous multi-Degree-Of-Freedom (DOF) robotic arm, tendon-driven truss sections increase the capacity of moment loads for extended configurations of the limb. This paper describes the analysis, work cell, operations, actuation, control, and instrumentation of limbs designed to address specific target load cases that might be required for human exploration missions on planetary surfaces.

Wilcox, Brian H.↗

Mid-Term Outcomes of Endovascular Treatment for TASC-II D Femoropopliteal Occlusive Disease with Critical Limb Ischemia

PurposeThe purpose of the study was to assess the safety and midterm effectiveness of endovascular treatment in Trans-Atlantic Inter-Society Consensus II (TASC-II) D femoropopliteal occlusions in patients with critical limb ischemia (CLI).MethodsPatients with CLI who underwent endovascular treatment for TASC-D de novo femoropopliteal occlusive disease between September 2008 and December 2013 were selected. Data included anatomic features, pre- and postprocedure ankle-brachial index, duplex ultrasound, and periprocedural complications. Sustained clinical improvement, limb salvage rate, freedom from target lesion revascularization (TLR), and freedom from target extremity revascularization (TER) were assessed by Kaplan–Meier estimation and predictors of restenosis/occlusion with Cox analysis.ResultsThirty-two patients underwent treatment of 35 TASC-D occlusions. Mean age was 76 ± 9. Mean lesion length was 23 ± 5 cm. Twenty-eight limbs (80 %) presented tissue loss. Seventeen limbs underwent treatment by stent, 13 by stent-graft, and 5 by angioplasty. Mean follow-up was 29 ± 20 months. Seven patients required major amputation and six patients died during follow-up. Eighteen endovascular and three surgical TLR procedures were performed due to restenosis or occlusion. Estimated freedom from TLR and TER rates at 2 years were 41 and 76 %, whereas estimated primary and secondary patency rates were 41 and 79 %, respectively.ConclusionsEndovascular treatment for TASC II D lesions is safe and offers satisfying outcomes. This patient subset would benefit from a minimally invasive approach. Follow-up is advisable due to a high rate of restenosis. Further follow-up is necessary to know the long-term efficacy of these procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

STUDY OF THE 3D GEOMETRIC STRUCTURE AND TEMPERATURE OF A CORONAL CAVITY USING THE LIMB SYNOPTIC MAP METHOD

We present the three-dimensional geometric structure and thermal properties of a coronal cavity deduced from limb synoptic maps. The observations are extreme ultraviolet images from the Atmospheric Imager Assembly (AIA) and magnetic images from the Helioseismic Magnetic Imager instruments on board the Solar Dynamics Observatory. We describe a limb synoptic-map method used to effectively identify and measure cavities from annuli of radiance above the solar limb. We find that cavities are best seen in the 211, 193, and 171 Å passbands. The prominence associated with each cavity is best seen in the 304 Å synoptic maps. We also estimate the thermal properties of the cavity and surrounding plasma by combining the AIA radiances with a differential emission measure analysis. This paper focuses on one long cavity from a catalog of coronal cavities that we are developing. Cavities in this catalog are designated by a coded name using the Carrington Rotation number and position. Cavity C211347177N was observed during Carrington Rotation 2113 at the northwestern limb of the solar disk with an average latitude of 47° N and a central longitude of 177°. We showed the following. (1) The cavity is a long tube with an elliptical cross-section with ratios of the length to width and the length to height of 11:1 and 7:1, respectively. (2) The cavity is about 1360 Mm long, or 170° in longitude. (3) It is tilted in latitude. (4) And it is slightly hotter than its surroundings.

79 ASTRONOMY AND ASTROPHYSICS↗

Peripheral Stent Thrombosis Leading to Acute Limb Ischemia and Major Amputation: Incidence and Risk Factors in the Aortoiliac and Femoropopliteal Arteries

PurposeTo report the real-world incidence and risk factors of stent thrombosis in the aortoiliac and femoropopliteal arteries in case of bare nitinol stent (BNS) or covered nitinol stent (CNS) placement from a single-centre retrospective audit.Materials and MethodsMedical records of consecutive patients treated with peripheral stent placement for claudication or critical limb ischemia were audited for definite stent thrombosis defined as imaging confirmed stent thrombosis that presented as acute limb-threatening ischemia. Cases were stratified between aortoiliac and femoropopliteal anatomy. Cox regression analysis was employed to adjust for baseline clinical and procedural confounders and identify predictors of stent thrombosis and major limb loss.Results256 patients (n = 277 limbs) were analysed over a 5-year period (2009–2014) including 117 aortoiliac stents (34 CNS; 12.8 ± 5.0 cm and 83 BNS; 7.8 ± 4.0 cm) and 160 femoropopliteal ones (60 CNS; 21.1 ± 11.0 cm and 100 BNS; 17.5 ± 11.9 cm). Median follow-up was 1 year. Overall stent thrombosis rate was 6.1% (17/277) after a median of 43 days (range 2–192 days) and affected almost exclusively the femoropopliteal segment (12/60 in the CNS cohort vs. 4/100 in the BNS; p = 0.001). Annualized stent thrombosis rates (per 100 person-years) were 12.5% in case of CNS and 1.4% in case of BNS (HR 6.3, 95% CI 2.4–17.9; p = 0.0002). Corresponding major amputations rates were 8.7 and 2.5%, respectively (HR 4.5, 95% CI 2.7–27.9; p = 0.0006). On multivariable analysis, critical leg ischemia and CNS placement were the only predictors of stent thrombosis. Diabetes, critical leg ischemia, femoropopliteal anatomy, long stents and CNS were independent predictors of major amputations.ConclusionsPlacement of long femoropopliteal covered nitinol stents is associated with an increased incidence of acute stent thrombosis and ensuing major amputation. Risks are significantly lower in the aortoiliac vessels and with use of bare nitinol stents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Mechanical Thromboembolectomy in Acute Lower Limb Ischemia

Purpose: To analyze the immediate outcome of percutaneous mechanical thromboembolectomy in acute infrainguinal leg ischemia in a consecutive cohort of patients with acute lower limb ischemia. Material and Method: We retrospectively analyzed the data of 156 acute infrainguinal ischemic events in 148 patients. Patients presented with acute limb ischemia Rutherford category I in 68 cases (44%), Rutherford category II A in 64 instances (41%) and Rutherford II B in 24 instances (15%). In 62 cases (39.7%), the occlusion site started below the knee joint level, in 94 (60.3%) cases above. As a basic technique, an intervention was started by manual aspiration but if aspiration failed, an additional device was added. Most frequently, a rotational thrombectomy device (Rotarex, Straub Medical, Wangs, Switzerland) was used. An antegrade access to the femoral artery was the preferred access to the limb (154/156). Results: In 145 of 156 incidents, a technical success was achieved (93%). Aspiration was used in 153 cases (98%). Rotational thrombectomy by use of the Rotarex catheter was added in 60 cases (38%). Directional atherectomy was applied in a total of five patients. As main technical complications, a downward embolization occurred (n = 11). There were four surgical groin revisions. Five patients died during the early follow-up with four not related to the intervention. Clinically, 135 patients (86.5%) showed an improvement in their clinical situation. Conclusion: Acute lower limb ischemia can be successfully treated by mechanical thromboembolectomy only by combining aspiration embolectomy with rotational thrombectomy in most cases but manual aspiration alone will frequently fail especially above the knee joint level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limb-brightened jet of 3C 84 revealed by the 43 GHz very-long-baseline-array observation

We present a study of the sub-parsec scale radio structure of the radio galaxy 3C 84/NGC 1275 based on the Very Long Baseline Array data at 43 GHz. We discover a limb brightening in the 'restarted' jet that is associated with the 2005 radio outburst. In the 1990s, the jet structure was ridge brightening rather than limb brightening, despite the observations being done with similar angular resolutions. This indicates that the transverse jet structure has recently changed. This change in the morphology reveals an interesting agreement with the γ-ray flux increase, i.e., the γ-ray flux in the 1990s was at least seven times lower than the current one. One plausible explanation for the limb brightening is that the velocity structure of the jet is in the context of the stratified jet, which is a successful scenario that explains the γ-ray emission in some active galactic nuclei. If this is the case, then the change in apparent transverse structure might be caused by the change in the transverse velocity structure. We argue that the transition from ridge brightening to limb brightening is related to the γ-ray time variability on the timescale of decades. We also discuss the collimation profile of the jet.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray bursts from solar flares behind the limb

X-ray bursts are identified from the UCSD OSO-7 X-ray experiment data. X-ray spectroheliograms of OSO-5, H alpha activity at the limb, and the emergence and disappearance of sunspot groups at the limb were studied and 17 active centers were found as likely seats of the X-ray bursts beyond the limb. The analysis of 37 X-ray bursts and their physical parameters is presented. Results show that (1) the distributions of maximum temperature, maximum emission measure, and characteristic cooling time of the over-the-limb events do not significantly differ from those of disk events; (2) that radiation is the dominant cooling mechanism for the hot flare plasma; and (3) that the scale height for X-ray emission in the 5-10 keV range is large. Observations show that the fraction of soft X-ray bursts which have a nonthermal component is the same on and off of the disk. Hard X-ray emission over extended regions is indicated.

Roy, J. R.↗

Lunar topography and the limb compression source regions

Data from the Apollo 15, 16, and 17 laser altimeters have been used to study slopes, elevations, and roughness in the identifiable regions on the moon which sporadically produce plasma compressions and magnetic-field enhancements in the solar wind/lunar void boundary when those regions are at a flow limb. It is found that occurrence rates for such 'limb compressions' derived from Explorer 35 satellite measurements are significantly correlated with peak, average, and RMS slopes in the source regions, whereas rates derived from Apollo 15 and 16 subsatellite data are not correlated with topography. This suggests that two or more mechanisms operate in the source regions to produce limb compressions. Together with the known correlation between limb compressions and local surface remanent magnetic fields, the results indicate that lunar magnetization is not strongly related to surface features.

Srnka, L. J.↗

Solar limb brightening in submillimeter wavelengths

Differential two-beam scans of the sun in submillimeter wavelengths (350 microns to 1 millimeter) indicate limb brightening approaching 1 percent when the cosine of the angle from the normal equals 0.60. The observations also show considerable chromospheric structure, both in active and quiet regions, but with less relative amplitude than at millimeter and centimeter wavelengths. The limited angular resolution of the observing system, together with photometric errors due to fluctuating atmospheric transparency, make the brightness profile of the extreme limb uncertain. The observed degree of limb brightening is considerably less than that consistent with spherically symmetric model atmospheres based on continuum brightness-temperature measurements. The suppression of limb brightening suggests the existence of irregular granular structure with both horizontal and vertical characteristic sizes of the order of 1500 km. High-resolution images in the wings of the K-line show granular structure of about this horizontal scale.

Lindsey, C.↗

Limb brightening on Uranus - The visible spectrum

Results are presented for pinhole and slit narrowband photoelectric area-scanning photometry of the Uranus disk at eight central wavelengths ranging from 5600 to 7500 A. The observations were undertaken to detect limb brightening on the planet and to study the nature of its disk profile as a function of geometrical albedo. A coarse analysis of the results shows that the disk must exhibit limb brightening in the two CH4 bands at 6190 and 7300 A relative to all other wavebands investigated. Except for the two CH4 bands, the shapes and widths of the images are found to be essentially identical; point-spread-function data for all wavebands indicate no significant variation in the representative Gaussian l/e width with wavelength. A fine analysis of the data reveals absolute limb brightening in the 7300-A CH4 band and absolute limb darkening in the adjacent wavebands. These results are shown to be consistent with the hypothesis that clouds are absent from the visible atmosphere of Uranus.

Price, M. J.↗

The center-to-limb

Center-to-limb measurements of the Ca I 6573 intercombination line and the Ca II 7324 forbidden line are compared with synthetic profiles based on a simple representation of the non-LTE Ca-Ca(+) ionization equilibrium. The effects of photoionizations from low lying excited states of neutral calcium are found to reduce the sensitivity of the 6573 center-to-limb behavior as a thermal structure diagnostic. The synthetic center-to-limb behavior is also sensitive to uncertainties in the nonthermal broadening. Nevertheless, the measured center-to-limb behavior of 6573 favors a 'cool' photospheric model over hotter models based on the Ca II K wings. The non-LTE calcium abundance obtained from the disk center equivalent widths of 6573 and 7324 using the best fit model is A(Ca) = 2.1 plus or minus 0.2 x 10 to the -6th (by number relative to hydrogen).

Source record↗

Limb blood flow - Rest and heavy exercise in sitting and supine positions in man

The objectives of the study were twofold: (1) to determine the effect of body position (hydrostatic pressure) on total blood flow in active and passive limbs at rest and after severe exercise; and (2) to further evaluate the impedance technique for measurement of blood flow. To this end, the effect of body position on the redistribution of total blood flow in active (leg) and passive (forearm) limbs during exercise was determined by measuring total limb impedance (blood flow) in five male and one female subjects in sitting and supine positions with a modified Beckman BR-100 rheograph. The results show that, at rest and after exercise, the supine position induces significantly greater flows in the leg but not in the forearm. With severe exercise, blood flows are increased in both passive and active limbs, so that there is probably no net transfer of blood volume from passive to active muscles. The advantages of the impedance technique over other methods are stressed.

Greenleaf, J. E.↗

Methane band limb-brightening on Uranus

Area scanner measurements of the brightness distributions of Uranus at 6300 and 7250 A are presented. At the former wavelength, which is characteristic of continuum radiation, the observed limb-darkening is consistent with the results of Stratoscope observations. At the latter wavelength, in the center of a strong methane absorption band, the planet shows substantial limb-brightening as has been reported by other investigators. The limb-brightening and geometric albedo of Uranus in this methane band can be explained in terms of a clear atmospheric model in which the methane partial pressure above the saturation level is equal to its equilibrium vapor pressure. This conclusion is relatively insensitive to the methane mixing ratio below the saturation level. The presence of a high-altitude, conservatively, isotropically scattering haze of optical thickness 0.1, such as that previously proposed as a possible cause of the 7250-A limb-brightening, would produce a geometric albedo at this wavelength that is substantially larger than the value observed for Uranus.

Pilcher, C. B.↗

Solar limb brightening at 350 microns

The NASA Infrared Telescope Facility at Mauna Kea was used to observe the intensity profile of the quiet solar limb in the 300-400 micron continuum. A significant resolved brightening of several percent over the outer 60 arcsec of the solar limb in this band is found. However, the magnitude of the brightening is considerably less than that indicated by earlier observations of a total solar eclipse in integrated sun-moon radiation by Beckman, Lesurf, and Ross (1975) in the 1.2 mm continuum. More recent ground-based observations indicate that the magnitude of solar limb brightening at 800 microns and at 1.3 mm is stronger than that at 350 microns. This may be regarded as an indication that the hot material which produces the brightening at the extreme limb, thought to consist in part of chromospheric spicules, is optically thin in the 350 micron continuum.

Lindsey, C.↗

Submillimeter extensions of the solar limb determined from observations of the total eclipse of 1981 July 31

First results are presented of observations of a lunar occultation of the solar limb made from the Kuiper Airborne Observatory in the 30 micrometr, 50 micrometer, 100 micrometer, and 200 micrometer continuum during the total solar eclipse of 1981 July 31. The solar limb was extended at the longer wavelengths up to 1000 km higher than predicted from smooth plane-parallel chromospheric models. Results at both second and third contact show the infrared limb extensions to be approximately 0".8, 1"5, 2".5 and 3".0 above the visible limb in the observed bands, respectively. A possible interpretation proposes chromospheric fine structure inhomogeneities of greater density than presently incorporated in models of the middle chromosphere.

Lindsey, C.↗

Development of limb volume measuring system

The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.

Bhagat, P. K.↗