Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY ANIMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Miniature biotelemeter giving 10 channels of wideband biomedical data.

A miniature biotelemeter has been developed for sensing and transmitting multiple channels of wideband biomedical data over a radio link. Its small size and weight make it capable of being carried by free-moving laboratory animals as small as rats. Ten data channels each of 5-kHz data bandwidth are provided to permit monitoring of a wide variety of physiological signals. Multichannel telemetry of electroencephalograms, electrocardiograms, electromyograms, state functions, and dynamic processes such as blood flow and body chemistry are possible applications. Utilization of newly available monolithic chip components, low-power COS/MOS MSI digital logic, and state-of-the-art hybrid mounting techniques makes this novel device useful for both research and clinical bioinstrumentation.

Carraway, J.↗

Microbiological and experimental-histological investigations of lunar samples returned by the Lunar 16 automatic station

Lunar surface material was studied for its content of viable microorganisms (aerobic and anaerobic, fungi, and viruses); the effect of the lunar surface material on the growth of microorganisms and its interaction with somatic cells of mammals was also observed. No viable microorganisms were detected; the samples exhibited neither stimulant or inhibitory action on the growth of microorganisms, and also showed no cytopathogenic action on tissue cultures. A suspension of lunar surface material particles was not toxic when parenterally administered to certain laboratory animals. The particles were subjected to intense phagocytosis by connective tissue cells in vivo and in vitro.

Kaulen, D. R.↗

Fluid infusion system

Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

Source record↗

Stress, temperature, heart rate, and hibernating factors in hamsters

Pathophysiological conditions resulting from prolonged exposure to zero gravity, cabin constraint, altered ambient environment, whether it be noise, vibrations, high temperatures, or combinations of such factors, are studied in laboratory animals and applied to manned space flight. Results and plans for further study are presented. Specific topics covered include: thermoregulation and its role in reflecting stress and adaptation to the gravity free environment and cabin confinement with its altered circadian forcings; renal function and its measurement in electrolyte distribution and blood flow dynamics; gastronintestinal function and an assessment of altered absorptive capacity in the intestinal mucosa; and catecholamine metabolism in terms of distribution and turnover rates in specific tissues.

Musacchia, X. J.↗

Relative toxicity of pyrolysis products of some foams and fabrics

A limited number of foams and fabrics was evaluated in the course of developing test procedures for determining the relative toxicity of materials. The principal variable studied, heating rate, did not affect the relative ranking of the materials tested. Two pyrolysis test procedures using the same basic approach but employing different sample weights, chamber volumes, laboratory animals, heating rates, and upper temperature limits, resulted in identical rankings of relative toxicity. The data obtained show that modification of conventional flexible polyurethane foams with flame retardants to comply with California upholstered furniture flammability regulations seems to consistently reduce toxicity under pyrolysis conditions.

Hilado, C. J.↗

Evaluation of the smoke density chamber as an apparatus for fire toxicity screening tests

The smoke density chamber is perhaps the most widely used apparatus for smoke measurements. Because of its availability, it has been proposed as an apparatus for evaluating fire toxicity. The standard apparatus and procedure were not found suitable for toxicity screening tests using laboratory animals, because not enough materials of interest produced animal mortality or even incapacitation under standard test conditions. With modifications, the chamber offers greater promise as a screening tool, but other tests specifically designed to measure relative toxicity may be more cost-effective. Where one-dimensional heat flux is a requirement, the chamber is the most suitable apparatus available. It should be improved in regard to visibility of animals and ease of cleaning.

Hilado, C. J.↗

Dual-purpose laboratory cage/antenna

Part of steel cage enclosing laboratory animals is used as an antenna to transmit biotelemetry over short distances. Receiving and signal processing equipment are located above ground potential to avoid transmission-path difficulties.

Lalande, B. H.↗

Batteryless implanted echosonometer

Miniature ultrasonic echosonometer implanted within laboratory animals obtains energy from RF power oscillator that is electronically transduced via induction loop to power receiving loop located just under animal's skin. Method of powering device offers significant advantages over those in which battery is part of implanted package.

Kojima, G. K.↗

Concepts in health evaluation of commercial and industrial chemicals

A method is described for determining no toxic effect exposure levels based on short-term testing of industrial and commercial chemicals. Procedures for monitoring all organs and body functions for the presence or absence of toxicological effects are demonstrated using various laboratory animals.

Mcnamara, B. P.↗

SMD 3 post test medical report

One of several reports that were prepared to document the results of the Spacelab Mission Development Test 3 is presented. This report covers clinical support to the crew as well as assistance and counsel to others in crew selection, health stabilization of the crew and the laboratory animals, and habitability and duty schedules.

Hordinsky, J. R.↗

An apparatus and procedure for evaluating the toxic hazards of smoldering seating and bedding materials

An apparatus and procedure are described for evaluating the toxicity of the gases evolved from the smoldering combustion of seating and bedding materials. The method combines initiation of smoldering combustion in fabric/cushion combinations by a lighted cigarette and exposure of laboratory animals to the gases evolved. The ratio of the surface available for smoldering to the compartment volume in this apparatus is approximately five times the ratio expected in a California living room, and 100 times the ratio expected in a wide-body aircraft passenger cabin. Based on fabric/cushion combinations tested, the toxicity of gases from smoldering combustion does not appear to be a significant hazard in aircraft passenger cabins, but seems to be a basis for careful selection of materials for residential environments.

Hilado, C. J.↗

Relative toxicity of materials in fire situations

The results of toxicity testing of additional materials is presented. Relative toxicity data on polymers by generic type are presented and include wood, polyurethane flexible foam, polyvinyl chloride (PVC), acrylonitrile/butadiene/styrene (ABS), and polyisoprene (natural rubber). A second table gives relative toxicity data on fibers and fabrics including wool, nylon, rayon, polyester, and aromatic polyamide. Sulfur-containing materials seemed to exhibit the shortest times to death of laboratory animals. Some chlorine-containing polymers tended to exhibit shortest time to death also while some halogen-containing polymers gave the shortest time to incapacitation. Among fibers and fabrics, wool, silk, and polyester exhibited the shortest times to incapacitation and times to death. Difficulty in restricting generally accepted materials is discussed and attention is given to other factors important in comparing materials, such as backcoatings and relative weights.

Hilado, C. J.↗

Nutritional models for space travel from chemically defined diets

Human nutritional requirements are summarized, including recommended daily intake and maximum safe chronic intake of nutrients. The biomedical literature on various types of chemically defined diets (CDD's), which are liquid, formulated diets for enteral and total parenteral nutrition, is reviewed. The chemical forms of the nutrients in CDD's are detailed, and the compositions and sources of representative commercial CDD's are tabulated. Reported effects of CDD's in medical patients, healthy volunteers, and laboratory animals are discussed. The effects include gastrointestinal side effects, metabolic imbalances, nutrient deficiencies and excesses, and psychological problems. Dietary factors contributing to the side effects are examined. Certain human nutrient requirements have been specified more precisely as a result of long-term use of CDD's, and related studies are included. CDD's are the most restricted yet nutritionally complete diets available.

Dufour, P. A.↗

Causes of the triglyceride-lowering effect of exercise training in rats

Studies conducted with human subjects and laboratory animals have consistently shown a reduction in serum triglyceride (TG) in exercise-trained subjects. The obtained data have suggested that this decrease was due to a reduction in hepatic TG secretion. The present investigation, which was conducted with rats trained to attain a high level of spontaneous running activity, provides support for the earlier results. In addition, insights are obtained regarding the mechanism by which exercise lowers TG levels. Since the liver accounts for the vast majority of endogenous very low density lipoprotein (VLDL)-TG secretion, the fall in TG secretion rate seen in exercise-trained (ET) rats must be due to a reduction in hepatic TG secretion.

Mondon, C. E.↗

Image processing mini manual

The intent is to provide an introduction to the image processing capabilities available at the Langley Research Center (LaRC) Central Scientific Computing Complex (CSCC). Various image processing software components are described. Information is given concerning the use of these components in the Data Visualization and Animation Laboratory at LaRC.

Matthews, Christine G.↗

Data Visualization and Animation Lab (DVAL): Applications

A wide variety of software tools has been successfully used to visualize, analyze and present computational and experimental data at Langley Research Center. These tools can be categorized according to five primary uses: (1) 2-D image analysis, (2) conventional 3-D visualization, (3) volume visualization, (4) photo-realistic rendering, or (5) special purpose applications. Software is accessible in each of these categories for Langley personnel, and training or consultation can be arranged with the Data Visualization and Animation laboratory staff.

Severance, Kurt↗

The Use of NASA Light-Emitting Diode Near-Infrared Technology for Biostimulation

Studies on cells exposed to microgravity and hypergravity indicate that human cells need gravity to stimulate growth. As the gravitational force increases or decreases, the cell function responds in a linear fashion. This poses significant health risks for astronauts in long-term spaceflight. The application of light therapy with the use of NASA LEDs will significantly improve the medical care that is available to astronauts on long-term space missions. NASA LEDs stimulate the basic energy processes in the mitochondria (energy compartments) of each cell, particularly when near-infrared light is used to activate the color sensitive chemicals (chromophores, cytochrome systems) inside. Optimal LED wavelengths include 680, 730 and 880 nm and our laboratory has improved the healing of wounds in laboratory animals by using both NASA LED light and hyperbaric oxygen. Furthermore, DNA synthesis in fibroblasts and muscle cells has been quintupled using NASA LED light alone, in a single application combining 680, 730 and 880 nm each at 4 Joules per centimeter squared. Muscle and bone atrophy are well documented in astronauts, and various minor injuries occurring in space have been reported not to heal until landing on Earth. An LED blanket device may be used for the prevention of bone and muscle atrophy in astronauts. The depth of near-infrared light penetration into human tissue has been measured spectroscopically.

Whelan, Harry T.↗

Body mass, energy intake, and water consumption of rats and humans during space flight

Alteration of metabolism has been suggested as a major limiting factor to long-term space flight. In humans and primates, a negative energy balance has been reported. The metabolic response of rats to space flight has been suggested to result in a negative energy balance. We hypothesized that rats flown in space would maintain energy balance as indicated by maintenance of caloric intake and body mass gain. Further, the metabolism of the rat would be similar to that of laboratory-reared animals. We studied the results from 15 space flights lasting 4 to 19 d. There was no difference in average body weight (206 +/- 13.9 versus 206 +/- 14.8 g), body weight gain (5.8 +/- 0.48 versus 5.9 +/- 0.56 g/d), caloric intake (309 +/- 21.0 versus 309 +/- 20.1 kcal/kg of body mass per day), or water intake (200 +/- 8.6 versus 199 +/- 9.3 mL/kg of body mass per day) between flight and ground control animals. Compared with standard laboratory animals of similar body mass, no differences were noted. The observations suggested that the negative balance observed in humans and non-human primates may be due to other factors in the space-flight environment.

Non-NASA Center↗