Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗

Driving lamps by induction

An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.

Laue, H. H.↗

Rare-gas analyses on neutron irradiated Apollo 12 samples.

Argon, krypton, and xenon from stepwise heating of five Apollo 12 rocks that had been irradiated to a neutron fluence of about 10 to the 19th neutrons/sq cm were analyzed mass-spectrometrically. The Ar40-Ar39 ages were determined and range from 3.18 plus or minus 0.06 x 10 to the 9th years to 3.32 plus or minus 0.06 x 10 to the 9th years. Trace elements Ba, Br, I, and U were measured via the neutron-induced reactions that produce isotopes of krypton and xenon. The following concentration ranges were observed: Ba, 46 to 70 ppm; Br, 48 to 146 ppb; I, 16 to 73 ppb; and U, 170 to 247 ppb.

Alexander, E. C., Jr.↗

The atmosphere of Mars near the surface - Isotope ratios and upper limits on noble gases

Several analyses of the Martian atmosphere have been carried out with the mass spectrometer in the molecular-analysis experiment. The ratios of abundant isotopes of carbon and oxygen are within 10 per cent of terrestrial values, whereas nitrogen-15 is considerably enriched on Mars. Argon-38 has been detected, and new limits on abundances of krypton and xenon have been set. The limit on krypton is sufficiently low to suggest that the inventories of volatile substances on Mars and on earth may be distinctly different.

Biemann, K.↗

Volumetric direct nuclear pumped laser

A volumetric direct nuclear pumped laser was developed in which the gas is a mixture of He-3 and a minority gas from the group of argon, krypton, xenon, chlorine and fluorine. The mixture of He-3 and the minority gas produces lasing with a minority gas concentration of from 0.01 to 10 percent argon, 1 percent krypton, 0.01 to 5 percent xenon and small concentrations of chlorine or fluorine.

Jalufka, N. W.↗

Quantum-chemical modeling of boron and noble gas dopants in silicon

The electron effects of the presence of boron and noble gas dopants in a model silicon lattice were investigated using a self-consistent charge extended Hueckel program. The extent of electronic interaction of the noble gas with the lattice is given by: Kr greater than Ar greater than Ne. Theoretically, boron diffusion in the presence of neon, argon or krypton was examined using a self-consistent charge extended Hueckel program. The net energy of interaction between boron and neon is strongly repulsive while argon-boron exhibits a region of relative stability; krypton exhibits behavior similar to argon though no region of stability was found for the range of separations used in the calculations. Finally, it is noted, from the relative energy of the topmost filled molecular orbital associated with boron (in an interstitial position), that activation of the boron does not require boron movement but can be accomplished by indirect transitions.

Aronowitz, S.↗

Development of a mass spectrometer system for the measurement of inert gases in meteorites

The study of the inert gases in meteorites has provided many clues as to the origin and evolution of the solar system. Particularly crucial and complex are the gases krypton and xenon. To accurately measure the isotopic compositions of these gases requires a mass spectrometer of high sensitivity and resolution. A previously unused and largely untested mass spectrometer system was brought to the point where it was ready for routine sample analyses. This involved, among other things, focusing the ion beam for optimal peak shape and sensitivity, documenting the instrument's response to a series of characteristic tests such as multplier gain checks, and interfacing the instrument to a computer to run the sample analyses. Following this testing and setting up, three iron meteorite samples were to be analyzed for argon, krypton, and xenon. The three samples were shown in prior work to possibly contain primordial heavy inert gases. Although these analyses have not yet been carried out, it is anticipated that they will be completed in the near future.

Palma, R. L.↗

A study of single and binary ion plasma expansion into laboratory-generated plasma wakes

Plasma expansion into the wake of a large rectangular plate immersed in a collisionless, supersonic plasma was investigated in laboratory experiments. The experimental conditions address both single ion and binary ion plasma flows for the case of a body whose size is large in comparison with the Debye length, when the potential difference between the body and the plasma is relatively small. A new plasma source was developed to generate equi-velocity, binary ion plasma flows, which allows access to new parameter space that have previously been unavailable for laboratory studies. Specifically, the new parameters are the ionic mass ratio and the ionic component density ratio. In a series of experiments, a krypton-neon plasma is employed where the ambient density ratio of neon to krypton is varied more than an order of magnitude. The expansion in both the single ion and binary ion plasma cases is limited to early times, i.e., a few ion plasma periods, by the combination of plasma density, plasma drift speed, and vacuum chamber size, which prevented detailed comparison with self-similar theory.

Wright, Kenneth Herbert, Jr.↗

Volatile inventory of Mars-2: Primordial sources and fractionating processes

The total volatile inventory of Mars has been modeled using meteoritic and presumed primordial abundances in the early solar system. Evidence is presented which indicates that the elemental abundances of the noble gases on Earth and Mars are similar, and their ratios are comparable to those in average carbonaceous chondrites with the exception of xenon and krypton. In order to account for presently observed variations in gas abundances, two primordial sources were used. One was the solar composition similar to the solar wind, and the other of carbonaceous grains that were the source for trace exotic components. For Mars, a model in which the early, high solar EUV flux with continued hydrogen production by differentiation results in mass fractionation of the primordial atmosphere, early depletion of xenon, and later depletion of gases lighter than krypton. The result is that the primordial Mars water inventory may have been on the order of 20 to 30 km if spread over the planet.

Pepin, R. O.↗

Solar, planetary, and other inert gases in two sieve fractions of a disaggregated Allende sample - A study by stepwise heating extraction

Inert gases released by stepwise heating of unaltered, strongly magnetic, and weakly magnetic samples from the 0-64 micron and the 105-250 micron fractions of a disaggregated and sieved sample of the Allende meteorite reveal the occurrence of both solar and planetary neon. The origin of the solar neon is thought to be implantation of solar wind ions. The origin of the planetary neon remains unresolved. Heavy isotope enriched components of krypton and xenon have been detected and there are some indications that a light krypton component may also be present. Other than a larger concentration of Xe-129 in the weakly magnetic samples, the signatures of the magnetic separates are isotopically very similar.

Palma, R. L.↗

Laboratory investigations of volatile trapping in comets

This research program consists of laboratory studies of the formation of ice at low temperatures to simulate the formation of comets in the outer solar nebula. The ice is condensed in the presence of various mixtures of gases at a given temperature, and then warmed to see at what temperatures the gases are released and how much gas was actually trapped. Our results to date indicate that the trapping of argon, krypton, and xenon in ice formed at approximately 50 K fractionates these gase in a way that fits the relative abundances found in the atmospheres of Mars and Earth. This is markedly different from the situation in chondritic meteorites, where the abundance of xenon is about equal to that of krypton. It appears that comets represent a better source for planetary volatiles than do the meteorites.

Owen, Tobias↗

13-kV Ion-Extraction System Being Developed for Inert Gas Ion Engines

A high-voltage ion optics design was chosen for an assumed outer planet or interstellar precursor mission that would require a long-life, high-power, high-specific-impulse krypton ion engine. Such an engine could support energetic space missions to the outer planets or beyond. Detailed performance and lifetime analyses and several inexpensive subscale grid tests were conducted at the NASA Glenn Research Center and at the Colorado State University under a NASA Glenn grant. A subscale grid set of the selected geometry shown was tested at voltages up to 13,000 V. This yielded a krypton ion beam current that would, when scaled to a full-size 50-cm diameter, produce an ion beam with a power of 30 kW at a specific impulse over 14,000 sec. The operational ion beam focusing limits, as a function of ion current per hole, were found to impose requirements of high uniformity on the discharge chamber plasma density. A full-size set of two-grid, 50-cm-diameter titanium ion optics has been fabricated and awaits testing.

Rawlin, Vincent K.↗

Hypersonic Wake Diagnostics Using Laser Induced Fluorescence Techniques

A review of recent research performed in iodine that involves a two photon absorption of light at 193 nm will be discussed, and it's potential application to velocimetry measurements in a hypersonic flow field will be described. An alternative seed atom, Krypton, will be presented as a good candidate for performing nonintrusive hypersonic flow diagnostics. Krypton has a metastable state with a lifetime of approximately 43 s which would prove useful for time of flight measurement (TOF) and a sensitivity to collisions that can be utilized for density measurements. Calculations using modest laser energies and experimental values show an efficiency of excited state production to be on the order of 10(exp -6) for a two photon absorption at 193 nm.

Mills, Jack L.↗

Electrodeless discharge lamp is easily started, has high stability

Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

Bell, W. E.↗