Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “KLYSTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Technology for Television

A project being conducted by Varian Associates, Inc. and Lewis Research Center would allow a Ultrahigh Frequency (UHF) TV station to save 50% of its electricity cost. Because UHF stations need substantially more transmitter power, an amplifying device was needed. In the early 1970's Dr. Henry Kosmahl of Lewis had developed a radiowave amplifier to improve satellite transmission. He later worked with modifying klystron transmitters, electronic vacuum tubes used to generate and amplify UHF frequencies. If Dr. Kosmahl's multistage depressed collector or MDC can be incorporated into the klystron, the magnetic field shapes of electron beams can be changed to aid the energy recovery function of the MDC.

Source record↗

Communications Transceivers for Venus Surface Missions

The high temperature of the surface of Venus poses many difficulties. Previous Venus landers have only operated for short durations before succumbing to the heat. NASA Glenn Research Center conducted a study on communications for long duration Venus surface missions. I report the findings in this presentation. Current technology allows production of communications transceivers that can operate on the surface of Venus, at temperatures above 450 C and pressures of over 90 atmospheres. While these transceivers would have to be relatively simple, without much of the advanced signal processing often used in modern transceivers, since current and near future integrated circuits cannot operate at such high temperatures, the transceivers will be able to meet the requirements of proposed Venus Surface mission. The communication bands of interest are High Frequency or Very High Frequency (HFNHF) for communication between Venus surface and airborne probes (including surface to surface and air to air), and Ultra High Frequency (UHF) to Microwave bands for communication to orbiters. For HFNHF, transceivers could use existing vacuum tube technology. The packaging of the vacuum tubes may need modification, but the internal operating structure already operates at high temperatures. Using metal vacuum structures instead of glass, allows operation at high pressure. Wide bandgap transistors and diodes may be able to replace some of the thermionic components. VHF communications would be useful for line-of- sight operations, while HF would be useful for short-wave type communications using the Venusian ionosphere. UHF and microwave communications use magnetically focused thermionic devices, such as traveling wave tubes (TWTs), magnetron (M-type) amplifiers, and klystrons for high power amplifiers, and backward wave oscillators (BWOs) and reflex klystrons for oscillators. Permanent magnets are already in use in industry that can operate at 500 C. These magnets could focus electron beam tubes on the surface of Venus. While microwave windows will need to be designed for the high pressure, diamond windows have already been demonstrated, so high-pressure microwave windows can be designed and built. Thus, all of these devices could be useful for Venus surface missions. Current electronic power conditioners to supply the high voltages used in these microwave devices cannot operate at high temperatures, but earlier electronic power conditioners that used vacuum tubes can be modified to work at high temperature. Evaluating the various devices in this study, the M-type traveling wave tube (where a traveling wave structure is used in a crossed-field device, similar to the Amplitron used on the Apollo missions) stood out for the high power amplifier since it requires a single high voltage, simplifying the power supply design. Since the receiver amplifier is a low power amplifier, the loss of efficiency in linear beam devices without a depressed collector (and thus needing a single high voltage) is not important; a low noise TWT is a possible solution. Before solid-state microwave amplifiers were available, such TWTs were built with a 1-2 dB noise figure. A microwave triode or transistor made from a wide bandgap material may be preferable, if available. Much of the development work needed for Venusian communication devices will need to focus on the packaging of the devices, and their connections, but the technology is available to build transceivers that can operate on the surface of Venus indefinitely.

Force, Dale A.↗

Communication satellite output devices

Semiconductor devices, tunnel diodes, transistors, varactor diodes, vacuum tube amplifiers, triodes, klystrons, and traveling wave tubes for communication satellite output devices

VACUUM TUBE↗

High-power transmitter development

Klystron filament current and voltage remote- metering circuits for high power transmitter of deep space instrumentation facility

REMOTE CONTROL↗

On forced RF generation of CW magnetrons for accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a quite large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for stabilization of magnetrons. In this case CW magnetrons with the injection-locked oscillations generate a high level of noise. This may preclude use of standard CW magnetrons in this operating mode in the Superconducting RF (SRF) accelerators. In this article we described a method developed for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The method is most suitable for powering high Q-factor cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

Virtual Critical Coupling in High-Power Resonant Systems

Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting per- formance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). Furthermore, the results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The PIP-II dedicated RFPI system final design

The Radio Frequency Protection Interlock (RFPI) system main responsibility is to collect predefined set of signals and to protect each RF station. In case of safety limits violations from any of this input signals the RFPI has to instantenously drop permits for the LLRF or RF amplifier (eq. Solid State Amplifier - SSA or klystron) operation.This paper presents an overview of the final design of the RFPI system dedicated for Proton Improvement Plan II (PIP-II) at Fermilab.

Cichalewski, Wojciech [Lodz, Tech. U.; Lodz U.]↗

On Forced RF Generation of CW Magnetrons for SRF Accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

43 PARTICLE ACCELERATORS↗

LLRF commissioning of the CEBAF C75 upgrades SAM 2024/25

An often-overlooked aspect of Low Level Radio Frequency (LLRF) design is commissioning of a new system. During Jlab’s Scheduled Accelerator Maintenance (SAM) in 2024, two C75 Cryomodule were installed in CEBAF with Jlab’s LLRF 3.0 system. Jlab’s team has invested effort in automating and standardizing their commissioning process. Several key components are klystron characterization, cavity characterization, and interlock verification. This poster will present the summary of LLRF preparation and commissioning efforts at Jlab.

Accelerator Physics↗

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

Kazakevich, G. [MUONS Inc., Batavia] (ORCID:000000↗

HIGH-SENSITIVITY 100- TO 300-GC RADIOMETERS

High thermal sensitivity 100 to 300 gc radiometers with 4 mm reflex klystrons as local oscillator sources for operation in the 2.1 and 1.3 mm atmospheric absorption region

RADIOMETER↗

Solid state high-voltage pulser operates with low supply voltage

High speed klystron cathode pulser requires low voltage to generate high-voltage pulses. Broadband video transformers are wound in two configurations - /1/ transmission line, multifilar toroids and /2/ loop coupling toroids. The circuit adapts to generate high-speed, high-voltage, high-stability power pulses at megawatt levels.

Milberger, W. E.↗