Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of the Neutron Electromagnetic Form Factors at High Momentum Transfer Using a Polarized 3He Target at Jefferson Lab

Ever since the composite structure of nucleons was uncovered, many experiments have been commissioned with the purpose of extracting parameters that shape our understanding of this structure. Form factors are powerful tools that rest at the forefront of the nucleon structure study. In the non-relativistic limit, they describe the magnetic and charge distributions inside the nucleon. The GEn-II experiment, which ran in Hall A of Jefferson Lab as a part of the SuperBigbite Spectrometer (SBS) program, aimed to extract the ratio of the neutron’s electric to magnetic Sachs form factors (GnE/GnM. This was accomplished using the double polarization technique: scattering polarized electrons with initial energies up to 8.45 GeV off high-density polarized 3He targets. The experiment was a coincidence measurement, with the scattered electrons detected in the BigBite Spectrometer and the recoil nucleons in a hadron calorimeter, a part of the SuperBigbite Spectrometer. The convection-style target cells used in this experiment have a 60cm long target chamber, an increase from the 40 cm cell used in the most recent polarized 3He target experiment. In addition, the cells were optically pumped from two sides of the pumping chamber. These improvements in design and functionality introduced world-record-breaking luminosity. This thesis presents preliminary results of the GEn-II experiment for the following 4-momentum transfer (Q2) values: 2.93, 6.76, and 9.78 GeV2, in addition to target performance and preliminary polarimetry results.

Presley, Hunter [Univ. of Virginia, Charlottesvill↗

Precision Measurement of the Neutron Magnetic Form Factor via the Ratio Method at Jefferson Lab Hall A

Protons and neutrons, collectively known as nucleons, are composed of quarks and gluons. The Sachs electromagnetic form factors encode information about the spatial distributions of charge and magnetization in the nucleon, particularly at low momentum transfer. In particular, the neutron magnetic form factor (GMn) provides crucial information about the distribution of magnetization inside the neutron and helps constrain theoretical models of nucleon structure. Quasi-elastic electron scattering from deuterium was measured up to Q^2=13.5 GeV^2 using the Super BigBite Spectrometer in Hall A at Jefferson Lab. In this work, the neutron magnetic form factor GMn was extracted at Q^2 = 3.0 GeV^2 and Q^2=4.5 GeV^2 using the Ratio Method. These results represent a subset of the full dataset collected in this experiment, which extended to significantly higher Q^2. The extracted GMn values agree with the existing global fit within approximately two standard deviations at Q^2=3.0 and show excellent agreement at Q^2=4.5. The measurements achieved systematic uncertainties of about 2% and statistical uncertainties below 0.5%, among the most precise determinations of GMn at these kinematics. These results demonstrate the robustness of the experimental technique and provide an important validation point for future extractions at higher Q^2, where data remain scarce. In addition, the GRINCH heavy gas Cherenkov detector—a key component of the experimental apparatus—was commissioned and achieved an electron detection efficiency of approximately 97%, supporting reliable particle identification. Together, the analysis presented here advances both our understanding of nucleon structure and the validation of the experimental methods and instrumentation used to access it.

Satnik, Maria [College of William and Mary, Willia↗

Inclusive and exclusive electron scattering data analysis from Jefferson Lab experiment E12-14-012

Since the first observations of neutrino oscillation, neutrino experiments have come a long way toward precise measurements of the neutrino oscillation parameters, but some obstacles still remain. The next generation of oscillation experiments, including the Deep Underground Neutrino Experiment (DUNE), will be using the Liquid Argon Time Projection Chambers (LArTPCs) with natural argon as the neutrino target material. A precise model of the neutrino cross section on argon does not exist, which is a source of significant uncertainty in such experiments. The E12-14-012 experiment at Jefferson Lab seeks to help remedy this via electron scattering measurements on argon and titanium targets. The experiment collected both inclusive (e,e') and exclusive (e,e'p) data at a wide range of kinematics with the intent to measure the electron-nucleus cross section and thus derive a spectral function for argon that can be used with neutrino experiments. The use of titanium in this experiment stems from the equivalent shell structure that its protons share with the neutrons in argon, which will be crucial in oscillation experiments but cannot be measured directly in electron scattering. This thesis collects several papers which present results from the E12-14-012 experiment. These results include the inclusive (e,e') cross sections for carbon, titanium, argon, and aluminum at a beam energy of 2.22 GeV and a scattering angle of 15.54 deg with uncertainty of less than 5%. Also included are the first results of the exclusive (e,e'p) cross section on argon and titanium.

Murphy, Matthew D.↗

Cavity Qualification and Production Update for SNS-PPU Cryomodules at Jefferson Lab

The Proton Power Upgrade (PPU) project at Oak Ridge National Lab’s Spallation Neutron Source (SNS) currently being constructed will double the proton beam power capability from 1.4 to 2.8 MW by adding seven cryomodules, each containing four six-cell high-beta (β = 0.81) superconducting radio frequency cavities. Research Instruments, located in Germany, built and processed the cavities at the vendor site, including electropolishing as the final active chemistry step. Twenty-eight cavities for seven cryomodules and an additional four cavities for a spare cryomodules were delivered to Jefferson Lab and first qualification tests were completed on all cavities as received from the vendor. The performance largely exceeded the requirements on quality factor and accelerating gradient. Here we present the status of initial cavity qualification tests, rework on unqualified cavities and final cavity qualification with helium vessel prior to installation in cryomodules. In addition, an update on cryomodule production is presented.

Dhakal, P.↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

Tagged DVCS on neutron with the CLAS12 Experiment and the detector BONuS12 at Jefferson Lab (USA)

Hadronic physics studies the properties of the proton and neutron. The theory of Quantum Chromodynamics (QCD) governs the structure of hadrons. Non-perturbative structure functions are used to describe the hadrons? structure. Generalized Parton Distributions (GPDs) are a set of structure functions providing access to a 3D view of the nucleon. GPDs contain information about the longitudinal momentum and transverse position of quarks and their correlation. They are related to the spin structure and play a role in solving the proton spin puzzle. They provide access to the quarks? orbital angular momentum, a crucial puzzle piece. For this, measurements on the proton, already present, and neutron are necessary. This thesis aims to explore Compton scattering on the neutron with a deuterium target by measuring the spectator proton with the CLAS12 detector and the BONuS12 RTPC at Jefferson Lab. This work first describes the implementation, which I carried out, of a Kalman filter to reconstruct spectator protons in the BONuS12 detector. The second part of the manuscript is dedicated to the work on the analysis of DVCS on the neutron with the subtraction of background noises. Two different methods for the subtraction of ?0 will be detailed. Finally, the obtained results are presented and discussed

Ouillon, Mathieu↗

First Measurement of the Isospin-Dependence of Nuclear Structure Functions at 12 GeV Jefferson Lab

The structure functions of protons and neutrons provide crucial insight into how the strong nuclear force, as described by Quantum Chromodynamics (QCD), manifests at everyday energies, allowing us to better understand precisely how quarks and gluons interact to form the basic building blocks of almost all visible mass in our universe. Despite more than 40 years of experimental and theoretical effort, the EMC effect – the observation that nuclear structure functions appear to be modified from those of free nucleons – is still not fully understood. One open question that remains is whether or not the modification of quark distributions is the same for all quark flavors. Determining the flavor (isospin) dependence of the EMC effect, which is predicted by several models, is essential for coming to a complete understanding of how QCD manifests in nuclei. To this end, inclusive electron Deep Inelastic Scattering (DIS) from nuclei with approximately constant atomic mass number A and variable proton-to-neutron ratio N/Z was measured in Jefferson Lab experiment E12-10-008 to look for isospin-dependent modification of nuclear structure functions. The preliminary EMC ratios presented here cover a kinematic range of 2.8 < Q2 < 8.1 GeV2 and 0.18 < xBj < 1.0. The size of the EMC effect in these nuclei is extracted by calculating the slope of the EMC ratio as a function of Bjorken x (xBj ) over the ranges 0.3 < xBj < 0.6 and 0.3 < xBj < 0.7; these slopes then are compared with existing world data. Our preliminary results do not appear to indicate significant isospin-dependence of the EMC effect, though a more careful study is needed once all results are confirmed.

Cotton, Cameron William [Univ. of Virginia, Charlo↗

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗

Measuring the Neutron Spin Asymmetry A1n in the Valence Quark Region in Hall C at Jefferson Lab

The quest to understand how the nucleon spin is decomposed into its constituent quark and gluon spin and orbital angular momentum (OAM) components has been at the forefront of nuclear physics for decades. Due to the non-perturbative nature of Quantum Chromodynamics (QCD) - the theory describing how quarks and gluons bind together to form protons and neutrons - making absolute predictions of nucleon spin structure is generally difficult, especially as a function of its quark and gluon longitudinal momentum fraction x. Measurements involving nucleon spin structure serve as a sensitive test for QCD, including ab-initio lattice QCD calculations due to the advent of the quasi-PDF formalism, and various predictions that diverge at large-x. The neutron spin asymmetry An 1 at high?x is a key observable for probing nucleon spin structure. In the valence domain (x > 0.5), sea effects are expected to be negligible, and so the total nucleon spin is considered to be carried by the valence quarks. The valence region can therefore enable us to study the role of quark OAM and other non-perturbative effects of the strong force. An 1 was measured in the deep inelastic scattering region of 0.40 < x < 0.75 and 6 < Q2 < 10 GeV2 in Hall C at Jefferson Lab using a 10.4 GeV longitudinally polarized electron beam, upgraded polarized 3He target, and the High Momentum Spectrometer (HMS) and Super High Momentum Spectrometer (SHMS). E12- 06-110 provides the first precision data in the valence quark region above x = 0.60, and its preliminary results proved consistent with earlier data disqualifying a pQCD model that excluded quark OAM. Combined with previous world proton data, the ratio of the polarized-to-unpolarized up quark momentum distribution (?u + ?u)/(u + u) remained positive at large-x, and the down quark (?d + ?d)/(d + d) remained negative.

Rehfuss, Melanie↗

Probing the Isospin Composition of Short-Range Correlated Pairs at Jefferson Lab Hall B

Nucleons in short-range correlated (SRC) pairs, due to their close proximity and high relative momentum, can provide insight into the short-range part of the strong nuclear interaction. In particular, the prevalence of np pairs is due to the dominance of a tensor term for correlated nucleons with momenta of approximately 400?600 MeV/c. This dissertation comprises two studies advancing the community?s understanding of the isospin composition of SRC pairs. First, I performed a study of proton and neutron knockout from initially low-momentum and high-momentum states in 3He. Previous work has shown that protons are disproportionately represented in high-momentum states in neutron-rich nuclei. I demonstrate that spectral functions for the proton-rich nucleus 3He predict, in agreement with data, that neutrons are disproportionately represented in high-momentum states, but that 3He does not display the same strong prevalence of np pairs that is observed in larger nuclei. Second, Generalized Contact Formalism (GCF), a well-supported theory for predicting SRC behavior, predicts the transition from an isospin-dependent, tensor-dominant interaction at intermediate distances to a scalar-dominant, isospin-independent interaction at very short distances. This dissertation uses data from the CLAS12 Nuclear Targets Experiments in Hall B at Jefferson Lab to measure the relative abundances of pp and pn pairs for increasing relative momentum and decreasing separation. I provide an independent confirmation of the previously-observed increase in pp pairs at increasing momentum of the struck nucleon. I also contribute to the application of the new CLAS12 Central Neutron Detector by precisely measuring the neutron detection efficiency and developing a machine learning model for rejecting charged particle background.

Seroka, Erin↗

Deep Exclusive p 0 Electroproduction Measured in Hall A at Jefferson Lab with the Upgraded CEBAF

Our understanding of the proton's structure in terms of its fundamental degrees of freedom, quarks and gluons, is incomplete. Generalized Parton Distributions (GPDs) can enhance our understanding of the partonic structure of the proton as it includes the correlation between the momentum and transverse position of partons. Exclusive electroproduction of the pion (ep→e'p'π 0 ) is one of the potential channels to access the GPDs. GPDs are defined at the Bjorken limit where the total amplitude can be factorized in a hard scattering of the photon off the quark and a soft part described by the GPDs. At sufficiently high Q 2 , a factorization scheme for exclusive meson production processes exists but only for longitudinally polarized virtual photons. As long as the longitudinally polarized virtual photons dominate the cross-section, we can have factorization and extract the GPDs. But the existing data for π 0 production at low Q 2 and low x B show the dominance of transverse part of the cross-section over the longitudinal one. Some transversity GPD models have found that an effective way to factorize the contribution from transversely polarized virtual photons to explain the dominance of σ T over σ L , shown by existing data. The experiment E12-06-114 ran in experimental Hall A during 2014-2016. The primary goal of this experiment was to measure the DVCS cross-section but the experimental configuration also allows the measurement of deep exclusive π 0 production. Taking advantage of the upgraded CEBAF at Jefferson Lab, we explored the high Bjorken-x (0.60) and high Q 2 regime for the first time. The extracted cross-section terms for π 0 production helps us to test the validity of QCD factorization in our kinematic regime. Our π 0 production results can be used to test and improve the existing models of proton structure. Cross-section results will be presented at two different Q 2 values for fixed x B of 0.60.

Karki, Bishnu↗

Assembly of the MOLLER Toroidal Magnets at Jefferson Lab

The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.

Lamont, Joseph [Thomas Jefferson National Accelera↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗