SEARCH · Engineering Papers
Results for “Ion beam analysis”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Insights into secondary ion formation during dynamic SIMS analysis: Evidence from sputtering of laboratory synthesized uranium compounds with a high-energy O− primary beam on a NanoSIMS 50L
Not Available
Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry
The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.
Thermal Stability and Ion Irradiation Response of Refined Grained V – 4Cr – 4Ti
Since the 1960’s, there has been interest in V-4Cr-4Ti and similar alloys as candidates for low activation structural materials for advanced nuclear reactors. V-4Cr-4Ti was produced using arc melting and subsequently subjected to large strain extrusion machining to produce a multimodal microstructure largely composed of nanocrystalline and ultrafine grain sizes. In-situ thermal stability of the multimodal V-4Cr-4Ti to 800 °C shows the formation of vanadium carbides with negligible grain growth. In-situ dual-beam 16 KeV He+ and 1 MeV Kr2+ ion irradiation performed at 700 °C to a final dose of ~5 displacements per atom show the formation of small He cavities well distributed throughout the system, with preferential clustering at grain boundaries. This work provides insight into how the increased fraction of grain boundaries affect the simultaneous dual beam ion irradiation response of multimodal V – 4 wt.% Cr – 4 wt.% Ti at elevated temperatures. Analysis of the cavities reveal an areal density of 0.024±0.007 cavities/nm2 and swelling of 0.236% after the dual-beam ion irradiation. Nanoindentation shows a ~50% increase in hardening after the ion irradiation at 700 °C.
Review of Multifunctional Separators: Stabilizing the Cathode and the Anode for Alkali (Li, Na, and K) Metal–Sulfur and Selenium Batteries
Alkali metal batteries based on lithium, sodium, and potassium anodes and sulfur-based cathodes are regarded as key for next-generation energy storage due to their high theoretical energy and potential cost effectiveness. However, metal–sulfur batteries remain challenged by several factors, including polysulfides’ (PSs) dissolution, sluggish sulfur redox kinetics at the cathode, and metallic dendrite growth at the anode. Functional separators and interlayers are an innovative approach to remedying these drawbacks. Here we critically review the state-of-the-art in separators/interlayers for cathode and anode protection, covering the Li–S and the emerging Na–S and K–S systems. The approaches for improving electrochemical performance may be categorized as one or a combination of the following: Immobilization of polysulfides (cathode); catalyzing sulfur redox kinetics (cathode); introduction of protective layers to serve as an artificial solid electrolyte interphase (SEI) (anode); and combined improvement in electrolyte wetting and homogenization of ion flux (anode and cathode). It is demonstrated that while the advances in Li–S are relatively mature, less progress has been made with Na–S and K–S due to the more challenging redox chemistry at the cathode and increased electrochemical instability at the anode. Throughout these sections there is a complementary discussion of functional separators for emerging alkali metal systems based on metal–selenium and the metal–selenium sulfide. The focus then shifts to interlayers and artificial SEI/cathode electrolyte interphase (CEI) layers employed to stabilize solid-state electrolytes (SSEs) in metal–sulfur solid-state batteries (SSBs). The discussion of SSEs focuses on inorganic electrolytes based on Li- and Na-based oxides and sulfides but also touches on some hybrid systems with an inorganic matrix and a minority polymer phase. The review then moves to practical considerations for functional separators, including scaleup issues and Li–S technoeconomics. The review concludes with an outlook section, where we discuss emerging mechanics, spectroscopy, and advanced electron microscopy (e.g. cryo-transmission electron microscopy (cryo-TEM) and cryo-focused ion beam (cryo-FIB))-based approaches for analysis of functional separator structure–battery electrochemical performance interrelations. Finally, throughout the review we identify the outstanding open scientific and technological questions while providing recommendations for future research topics.
Quantum process tomography of a Mølmer-Sørensen gate via a global beam
Here, we present a framework for quantum process tomography of two-ion interactions that leverages modulations of the trapping potential and composite pulses from a global laser beam to achieve individual-ion addressing. Tomographic analysis of identity and delay processes reveals dominant error contributions from laser decoherence and slow qubit frequency drift during the tomography experiment. We use this framework on two co-trapped 40 Ca + ions to analyze both an optimized and an overpowered Mølmer–Sørensen gate and to compare the results of this analysis to a less informative Bell-state tomography measurement and to predictions based on a simplified noise model. These results show that the technique is effective for the characterization of two-ion quantum processes and for the extraction of meaningful information about the errors present in the system. The experimental convenience of this method will allow for more widespread use of process tomography for characterizing entangling gates in trapped-ion systems.
Beam-ion Studies in NSTX and NSTX-U (Final Technical Report)
The confinement of high energy "fast ions" is crucial for the success of magnetic fusion as a practical energy source. The research performed by UC Irvine on NSTX and NSTX-U provided new information about this important topic in the configuration known as a "spherical tokamak." Injected neutral beams provided the fast ions (also known as "beam ions"). There were five overarching goals of the research. One objective was to measure the confinement of beam ions in order to ascertain if they were accomplishing their desired purpose of transferring their energy to the bulk plasma. A second goal was to better understand instabilities that are driven unstable by the fast ions. A related goal was to use the similarities and differences between NSTX and the DIII-D conventional tokamak to better understand the fast-ion driven instabilities. A fourth goal was to develop new instruments to measure fast ions and techniques that facilitate analysis of the data. The fifth objective was to measure and understand acceleration of beam ions by RF waves. Much was accomplished in all of these five areas. In the first, it was shown that the large magnetic moment of the beam ions did not harm confinement but instabilities known as the "sawtooth" and "long-lived mode" do. In the second area, much attention was devoted to the fast-ion instabilities known as "Alfvén eigenmodes." In particular, Alfvén eigenmode "avalanches" can cause ~ 30% of the fast ions to be lost in a single explosive burst. The comparative studies with DIII-D showed that an instability discovered on NSTX is also important in conventional tokamaks. In the fourth category, several instruments were developed, a number of effects that complicate interpretation of the data were understood, and progress toward a new method to infer the fast-ion distribution function from the data was made. In the fifth category, the measured profile of accelerated fast ions was initially much broader than theoretical predictions but subsequent improvements in the theoretical modeling achieved good agreement with the data.
The dominant micro-turbulence instabilities in the lower q 95 high β p plasmas on DIII-D and predict-first extrapolation
Large-radius internal transport barriers (ITB) are the signature of high β p scenarios on DIII-D. Previous studies show that a large Shafranov shift, rather the E x B shear, suppresses the turbulence and helps in the formation of the large-radius ITB. New gyrokinetic simulations suggest that the remaining micro-instabilities in lower q 95 (<7.0), high β p ITB plasmas are drift wave instabilities, including the collisionless trapped electron mode in the core and ITB peak gradient region, the electron temperature gradient mode in the ITB peak gradient region and at the ITB foot and the ion temperature gradient mode at the ITB foot. Gyrokinetic simulation results qualitatively agree with the density fluctuation analysis from beam emission spectroscopy, which suggests the existence of a low-k ion mode at the ITB foot. As a result, the gyrokinetic simulations also predict that a larger Shafranov shift can overwhelm the driving sources for turbulence from the profile gradients at higher β N , leading to stronger turbulence suppression and stronger ITBs in lower q 95 , high β p plasmas.
Surface Analysis and Hydrogen Permation Measurements for Super-Permeating Membrane Materials
In this report, we summarize preliminary surface characterization results for Nb surfaces, using low energy ion scattering, direct recoil spectrometry, and Auger electron spectroscopy. While most surface analysis tools cannot detect hydrogen, the low energy ion beam techniques described here are among the few techniques that are directly sensitive to it. For this study, we examined chemisorption using both molecular and atomic hydrogen (using an heated tungsten capillary to dissociate the hydrogen.) To complement these results, we have been performing ex-situ spectroscopic ellipsometry as a means of detecting the surface oxide.
Fast ion transport by sawtooth instability in the presence of ICRF-NBI synergy in JET plasmas
JET experiments have shown that the three-ion scenarios using waves in the ion cyclotron range of frequencies (ICRF) is an efficient way to build fast ion population through beam ion acceleration by radio frequency (RF) waves. Here, such a heating scheme is applied to plasmas with at least two thermal ion species. Analysis of mixed discharges with complex heating schemes requires a workflow that allows to model thermal and fast ion transport consistently. This paper is dedicated to modelling of a mixed plasma discharge with significant fraction of fast ions and contributes to development of fast ion transport models. For interpretive analysis with the TRANSP code a JET hydrogen-deuterium (HD) plasma discharge with neutral beam injection (NBI) and ICRF heating has been chosen. The task is complicated by NBI-ICRF synergy and plasma magnetohydrodynamic activity, like sawtooth crashes. D beam ions accelerated by RF waves form a high energy tail in fast ion distribution. Significant difference between the neutron rate computed by TRANSP and measured one is observed if the same diffusivity for electrons and ions is assumed. Sensitivity studies show that uncertainties in input plasma parameters and thermal ion transport models are crucial for modelling mixed plasma discharges and increased D transport is required to reach the plasma composition consistent with diagnostic measurements at the plasma edge. Fast ion redistribution by a sawtooth instability is characterised by non-resonant transport due to reconnection of magnetic field lines and resonant transport caused by resonance interaction between the instability and fast ions. With ORBIT simulations it has been shown that resonant interaction strongly affects fast ions of high energies, like beam ions accelerated by RF waves and fusion products. For the considered case, fast ion profiles simulated by ORBIT remain peaked after the sawtooth crashes.
Measurement of Boron by 3 He Nuclear Reaction Analysis
Reference samples with known boron coverage are needed for calibrating measurements of boron deposition in tokamaks where boron is used for wall conditioning to improve fusion plasma performance. This report summarizes recent work at the Sandia Ion Beam Laboratory to fabricate such reference samples. Rutherford backscattering and nuclear reaction analysis were used to determine the boron coverage on reference samples consisting of a thin layer of boron on a silicon substrate.
High Resolution Multimodal Chemical Imaging Platform for Organics and Inorganics
Chemical analysis at the nanoscale is critical to advance our understanding of materials and systems from medicine and biology to material science and computing. Macroscale-observed phenomena in these systems are in the large part driven by processes that take place at the nanoscale and are highly heterogeneous. Therefore, there is a clear need to develop a new technology that enables correlative imaging of material functionalities with nanoscale spatial and chemical resolutions that will enable us to untangle the structure–function relationship of functional materials. As such, here, we report on the analytical figures of merit of the newly developed correlative chemical imaging technique of helium ion microscopy coupled with secondary ion mass spectrometry (HIM-SIMS) that enables multimodal topographical/chemical imaging of organic and inorganic materials at the nanoscale. In HIM-SIMS, a focused ion beam acts as a sputtering and ionization source for chemical analysis along with simultaneous high-resolution surface imaging, providing an unprecedented level of spatial resolution for gathering chemical information on organic and inorganic materials. In this work, we demonstrate HIM-SIMS as a platform for a next-generation tool for an in situ material design and analysis capable of down to 8 nm spatial resolution chemical imaging, layered metal structure imaging in depth profiling, single graphene layer detection, and spectral analysis of metals, metal oxides, and polymers.
Proton branching ratios in 22 Mg for X-ray bursts
Here, decay protons from 22 Mg energy levels populated through a previously reported 24 Mg(p, t) 22 Mg transfer reaction (Chae et al. in Phys Rev C 79:055804, 2009) have been analyzed for proton branching ratios as a follow-up analysis. The measurement was performed at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory by utilizing 41-MeV proton beams and 24 Mg solid targets. Decay protons and reaction tritons were simultaneously detected with a silicon detector array. By investigating the 24 Mg(p, t) 22 Mg*(p) 21 Na channels, the proton branching ratios of five 22 Mg excited states were obtained. The measured branching ratios provide constraints on the proton partial widths of the populated 22 Mg levels, which have implications for X-ray burst nucleosynthesis.
Evaluation of Lithium Metal Anode Volumetric Expansion through Laser Plasma Focused Ion Beam Cross-Sectional Imaging
Lithium metal is an ideal anode for high energy density batteries, however the implementation of lithium metal anodes remains challenging. Beyond the development of highly efficient electrolytes, degradation processes restrict cycle life and reduce practical energy density. Herein lithium volumetric expansion and degradation pathways are studied in half cells through coupling electrochemical analysis with cross-sectional imaging of the intact electrode stack using a cryogenic laser plasma focused ion beam and scanning electron microscope. Here, we find that the volumetric capacity is compromised as early as the first cycle, at best reaching values only half the theoretical capacity (1033 vs 2045 mAh cm -3 ). By the 101st electrodeposition, the practical volumetric capacity decreases to values ranging from 143 to 343 mAh cm -3 .
Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments
Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.
JuTrack: A Julia package for auto-differentiable accelerator modeling and particle tracking
Efficient accelerator modeling and particle tracking are key for the design and configuration of modern particle accelerators. In this work, we present JuTrack, a nested accelerator modeling package developed in the Julia programming language and enhanced with compiler-level automatic differentiation (AD). With the aid of AD, JuTrack enables rapid derivative calculations in accelerator modeling, facilitating sensitivity analyses and optimization tasks. Here we demonstrate the effectiveness of AD-derived derivatives through several practical applications, including sensitivity analysis of space-charge-induced emittance growth, nonlinear beam dynamics analysis for a synchrotron light source, and lattice parameter tuning of the future Electron-Ion Collider (EIC). Through the incorporation of automatic differentiation, this package opens up new possibilities for accelerator physicists in beam physics studies and accelerator design optimization.
The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS
The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.
Argon broad ion beam sectioning and high resolution scanning electron microscopy imaging of hydrated alite
Highlights: • The native fibrous outer and dense inner C-S-H structure are preserved by using low energy argon broad ion beam sectioning. • Possible artefacts of the preparation and imaging of hydrated alite are shown and discussed. • An approach for a semi automated pore analysis of the obtained high resolution images is demonstrated. Scanning electron microscopy (SEM) imaging is able to visualize micro- to nano-structures of cement and concrete. A prerequisite is that the sample preparation preserves the native structure of the specimen. In this study, argon broad ion beam (BIB) sectioning is compared to state-of-the-art sample preparation (resin embedding, polishing) for hydrated alite. Additionally, it is investigated if during BIB, sample cooling is beneficial to avoid deterioration of cement hydrates. The aim is to quantitatively measure pore size distributions in hardened alite pastes. Therefore, not only optimized sample preparation but also optimized imaging conditions are investigated. Finally, it is demonstrated that by image analysis pores down to a diameter of 5 nm in hydrated alite pastes can be quantitatively analysed.