Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Impacts of Instrument Limitations on Estimated Raindrop Size Distribution, Radar Parameters, and Model Microphysics during Mei-Yu Season in East China

Instrumentation limitations on measured raindrop size distributions (DSDs) and their derived relations and physical parameters are studied through a comparison of the DSD measurements during mei-yu season in east China by four collocated instruments, that is, a two-dimensional video disdrometer (2DVD), a vertically pointing Micro Rain Radar (MRR), and two laser-optical OTT Particle Size Velocity (PARSIVEL) disdrometers (first generation: OTT-1; second generation: OTT-2). Among the four instruments, the 2DVD provides the most accurate DSD and drop velocity measurements, so its measured rainfall amount has the best agreement with the reference rain gauge. Other instruments tend to miss more small drops ( D < 1 mm), leading to inaccurate DSDs and a lower rainfall amount. The low rainfall estimation becomes significant during heavy rainfall. The impacts of instrument limitations on the microphysical processes (e.g., evaporation and accretion rates) and convective storm morphology are evaluated. This is important especially for mei-yu precipitation, which is dominated by a high concentration of small drops. Furthermore, the instrument limitations need to be taken into account in both QPE and microphysics parameterization.

47 OTHER INSTRUMENTATION↗

The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation: Report to the NNSA DOE Office of International Nuclear Safeguards (NA-241)

The U.S Department of Energy (DOE) National Nuclear Security Administration (NNSA) Next Generation Safeguards Initiative (NGSI) and the International Atomic Energy Agency (IAEA) convened a workshop on Software Sustainability for Safeguards Instrumentation in Vienna, Austria, May 6-8, 2014. Safeguards instrumentation software must be sustained in a changing environment to ensure existing instruments can continue to perform as designed, with improved security. The approaches to the development and maintenance of instrument software used in the past may not be the best model for the future and, therefore, the organizers’ goal was to investigate these past approaches and to determine an optimal path forward. The purpose of this report is to provide input for the DOE NNSA Office of International Nuclear Safeguards (NA-241) and other stakeholders that can be utilized when making decisions related to the development and maintenance of software used in the implementation of international nuclear safeguards. For example, this guidance can be used when determining whether to fund the development, upgrade, or replacement of a particular software product. The report identifies the challenges related to sustaining software, and makes recommendations for addressing these challenges, supported by summaries and detailed notes from the workshop discussions. In addition the authors provide a set of recommendations for institutionalizing software sustainability practices in the safeguards community. The term “software sustainability” was defined for this workshop as ensuring that safeguards instrument software and algorithm functionality can be maintained efficiently throughout the instrument lifecycle, without interruption and providing the ability to continue to improve that software as needs arise.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Atmospheric Sounder Spectrometer for Infrared Spectral Technology (ASSIST) Instrument Handbook

The Atmospheric Sounder Spectrometer for Infrared Spectral Technology (ASSIST) measures the absolute infrared (IR) spectral radiance (watts per square meter per steradian per wavenumber) of the sky directly above the instrument. More information about the instrument can be found through the manufacturer’s website. The spectral measurement range of the instrument is 3300 to 520 wavenumbers (cm -1 ) or 3-19.2 microns for the normal-range instruments and 3300 to 400 cm -1 or 3-25 microns, for the extended-range polar instruments. Spectral resolution is 1.0 cm -1 . Instrument field-of-view is 1.3 degrees. Calibrated sky radiance spectra are produced on cycle of about 141 seconds with a group of 6 radiance spectra zenith having dwell times of about 14 seconds each interspersed with 55 seconds of calibration and mirror motion. The ASSIST data is comparable to the Atmospheric Emitted Radiance Interferometer (AERI) data and can be used for 1) evaluating line-by-line radiative transport codes, 2) detecting/quantifying cloud effects on ground-based measurements of infrared spectral radiance (and hence is valuable for cloud property retrievals), and 3) calculating vertical atmospheric profiles of temperature and water vapor and the detection of trace gases.

47 OTHER INSTRUMENTATION↗

Sulfur Dioxide Analyzer Instrument Handbook

The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO 2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO 2 + hυ1 →SO 2 *→SO 2 + hυ2 The emitted light is proportional to the concentration of SO 2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumentation Framework for Molten Salt Reactors

This report provides an overview of the specialized instrumentation necessary to operate and maintain liquid-fueled molten salt reactors (MSRs). The report does not include non-specialized industrial process control instrumentation, fissile material tracking instrumentation, or digital control/communication technologies. The report focuses on identifying MSR measurement technology gaps, and recommending research, development, and demonstration (RD&D) activities to close the identified gaps. To a large extent modern MSRs can rely on the instrumentation demonstrated during prior MSR development efforts. No fundamental technology gaps have been identified that would prevent operating or maintaining MSRs. However, improved instrumentation technology combined with the integration of modern process modeling and simulation could significantly improve the reliability and decrease the operating costs of future plants. The largest potential impact of new instrumentation technologies is in the integration of maintenance automation into reactor operations. Flow measurement has the largest technology hurdles remaining for to enable deployment of robust systems. Also, the technology for reliable, on-line fuel salt sample acquisition remains at relatively low technology readiness.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Intercomparison of Integrated Water Vapor Measurements at High Latitudes from Co-Located and Near-Located Instruments

Data from global positioning system (GPS) ground-based receivers, ground-based microwave radiometers (MWRs), and radiosondes (RS) at two high-latitude sites were compared. At one site, the North Slope of Alaska (NSA), Barrow, Alaska (USA), the instruments were co-located, while at the other site, the second ARM Mobile Facility (AMF2), Hyytiälä, Finland, the GPS receiver was located about 20 km away from the MWRs and RS. Differences between the GPS-derived integrated water vapor (IWV) and the other three instruments were analyzed in terms of mean differences and standard deviation. A comparison of co-located and near-located independently calibrated instruments allowed us to isolate issues that may be specific to a single system and, to some extent, to isolate the effects of the distance between the GPS receiver and the remaining instruments. The results showed that at these two high-latitude sites, when the IWV was less than 15 kg/m 2 , the GPS agreed with other instruments within 0.5–0.7 kg/m 2 . When the variability of water vapor was higher, mostly in the summer months, the GPS agreed with other instruments within 0.8–1 kg/m 2 . The total random uncertainty between the GPS and the other systems was of the order of 0.6–1 kg/m 2 and was the dominant effect when the IWV was higher than 15 kg/m 2 .

47 OTHER INSTRUMENTATION↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

60 APPLIED LIFE SCIENCES↗

TH-A-17A-01: Innovation in PET Instrumentation and Applications

Innovation in PET instrumentation has led to the new millennium revolutionary imaging applications for diagnosis, therapeutic guidance, and development of new molecular imaging probes, etc. However, after several decades innovations, will the advances of PET technology and applications continue with the same trend and pace? What will be the next big thing beyond the PET/CT, PET/MRI, and Time-of-flight PET? How will the PET instrumentation and imaging performance be further improved by novel detector research and advanced imaging system development? Or will the development of new algorithms and methodologies extend the limit of current instrumentation and leapfrog the imaging quality and quantification for practical applications? The objective of this session is to present an overview of current status and advances in the PET instrumentation and applications with speakers from leading academic institutes and a major medical imaging company. Presenting with both academic research projects and commercial technology developments, this session will provide a glimpse of some latest advances and challenges in the field, such as using semiconductor photon-sensor based PET detectors to improve performance and enable new applications, as well as the technology trend that may lead to the next breakthrough in PET imaging for clinical and preclinical applications. Both imaging and image-guided therapy subjects will be discussed. Learning Objectives: Describe the latest innovations in PET instrumentation and applications Understand the driven force behind the PET instrumentation innovation and development Learn the trend of PET technology development for applications.

60 APPLIED LIFE SCIENCES↗

DMS Instrument Directory Scanner

This program examines the source folder on instrument computers to find files and folders. It creates a tab-delimited text file for each instrument, listing the names of the files and folders found. The text files for the instruments are stored in a central location, and are made made visible via the DMS website to allow instrument operators to see the instrument data files on the instrument computer.

Monroe, Matthew↗

Learning Team Breach of a Posted Barricade to Connect an Instrument to Power

On February 15, 2017, a DESHF-STO HPFC (health physics field coordinator) was asked by an NEN-1 employee if they could move an instrument, a radiation dosimetry system, from A166A to another lab at TA-35 Building 2. The HPFC walked the job down and discovered the instrument was connected to power. The instrument had not been connected to power previously. See photo 1. The instrument is located within an RCA (radiological control area). Entry to connect the instrument to power the instrument requires contacting RP. RP personnel had not been contacted as required as stated in the RCA posting.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Southern Great Plains (SGP) Aerosol Observing System (AOS) Instrument Handbook

The ARM AOSs are not instruments in and of themselves, but rather each is a collection of instruments that make up what is termed the “ARM Baseline Instrumentation”. The AMF3 AOS consists of the instruments listed above as well as any “guest” instruments that may be present during any given intensive operational period (IOP). A series of subsystems operate in the background and are essential to the operation of the instruments and the AOS as a whole.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Sensors and Instrumentation Issue 10

The Advanced Sensors and Instrumentation (ASI) program, on its seventh fiscal year, continues to address key technology gaps for future nuclear energy systems. ASI’s goal is to enable the advanced instrumentation and control (I&C) technologies essential to the Office of Nuclear Energy’s research and development (R&D) efforts needed to realize its mission goals. Information on our projects can be found in our ASI annual awards summaries, annual review webinars, and newsletters posted in the Office of Nuclear Energy website (energy.gov/ne). This year, we have initiated three newly awarded projects in the area of data analytics. We also initiated a project to develop and demonstrate a prototype passive wireless sensor network. This sensor will use advanced manufacturing and printing, and be tested and demonstrated at a U.S. nuclear power plant facility. In addition, we are developing a sensor database to capture advanced sensor and instrumentation technology that is applicable to nuclear power plants. Under the In-Pile Instrumentation program, we continue to develop unique in-pile sensors and instrumentation to provide real-time, accurate, and spatially resolved information regarding the performance of fuels and materials. Due to the closure of the Halden reactor, we are focusing our near-term research in providing equivalent capability for the instrumentation of irradiation experiments in the U.S. that are needed by the nuclear industry. As the ASI program continues to award projects through competitive solicitations, we encourage the I&C community to visit our website for current funding opportunity announcements, especially for the industry-focused solicitation entitled, “U.S. Industry Opportunities for Advanced Nuclear Technology Development.”

99 GENERAL AND MISCELLANEOUS↗

Neutron Instruments for Research in Coordination Chemistry

Here, neutron diffraction and spectroscopies offer unique insight into structures and properties of solids and molecular materials. All neutron instruments located at the various neutron sources are distinct, even if their designs are based on similar principles, and thus, are usually less familiar to the community than commercial X–ray diffractometers and optical spectrometers. Major neutron instruments in the USA, which are open to scientists around the world, and examples of their use in coordination chemistry research are presented here, along with a list of similar instruments at main neutron facilities in other countries. The reader may easily and quickly find from this mini–review an appropriate neutron instrument for research. The instruments include single–crystal and powder diffractometers to determine structures, inelastic neutron scattering (INS) spectrometers to probe magnetic and vibrational excitations, and quasielastic neutron scattering (QENS) spectrometers to study molecular dynamics such as methyl rotation on ligands. Key and unique features of the diffraction and neutron spectroscopies that are relevant to inorganic chemistry are reviewed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced Instrumentation for Transient Testing

A fuel safety research program centered on in-pile transient testing experiments is being developed to support assessment and qualification of advanced nuclear fuel systems using the recently restarted Transient Reactor Test (TREAT) facility at the Idaho National Laboratory (INL). While resumption of transient testing at TREAT is crucial to enable these programs, full recovery and cutting-edge transient testing capability also requires a well-coordinated and innovative instrumentation development and qualification program to support near-term and future objectives. This paper summarizes the experimental approach of transient testing to focus on measuring the response of nuclear fuel to off-normal (or power-cooling mismatch) conditions for modern and advanced reactor environments requiring capabilities extending over wide measurement and environment conditions. It also highlights unique attributes of transient testing of importance to in-pile instruments including relatively low total neutron fluence, high gamma heating, and the need for well-defined and possibly short time response. Historical approaches to instrumentation for transient testing are also reviewed to provide context to the modern instrument strategy. The instrumentation needs of a modern transient testing are detailed while summarizing several ongoing R&D activities are supporting the development of state-of-the-art and ‘advanced’ measurement technologies that will provide baseline capability for Light Water Reactor (LWR) and Sodium-Cooled Fast Reactor (SFR) experiment objectives, while extending to other advanced reactor needs and advanced sensing technology opportunities. Examples of specific sensors planned for near-term deployment with ongoing development includes prompt-response self-powered neutron detectors (SPND), miniature fission chambers, optical-fiber-coupled infrared pyrometer, cladding surface thermocouples, electrical-impedance based boiling detector, and Linear Variable Differential Transformer (LVDT) based sensors for fuel elongation and pressure measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗