Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The energy spectrum of cosmic ray electrons between 9 and 300 GeV

The high-energy cosmic-ray electron spectrum between 9 and 300 GeV has been measured using an instrument consisting of a combination of a transition-radiation detector and a shower detector. The instrument has been calibrated at accelerators over the energy range 5-300 GeV and has been exposed in a balloon flight for 9.3 sq m sr hr. The design of the instrument and the data analysis procedures are described. It is found that the electron spectrum is significantly steeper than the proton spectrum. If the spectrum is fitted to a single power law, a spectral index of 3.35 is obtained. This suggests the influence of radiative energy losses on galactic electrons at low energies. The results are interpreted in the context of the homogeneous model for galactic cosmic rays.

Prince, T. A.↗

Thermal design and verification of an instrument cooling system for infrared detectors utilizing the Oxford Stirling cycle refrigerator

A detailed nodal computer model was developed to thermally represent the hardware, and sensitivity studies were performed to evaluate design parameters and orbital environmental effects of an instrument cooling system for IR detectors. Thermal-vacuum testing showed excellent performance of the system and a correspondence with math model predictions to within 3 K. Results show cold stage temperature sensitivity to cold patch backload, outer stage external surface emittance degradation, and cold stage emittance degradation, respectively. The increase in backload on the cold patch over the mission lifetime is anticipated to be less than 3.0 watts, which translates to less than a 3-degree increase in detector temperatures.

Werrett, Stephen↗

The Detector Subsystem for the SXS Instrument on the Astro-H Observatory

The Soft X-ray Spectrometer (SXS) instrument on the Astro-H observatory is based on a 36 pixel x-ray calorimeter array cooled to 50 mK in a sophisticated spaceflight cryostat. The SXS is a true spatial-spectral instrument, where each spatially discrete pixel functions as a high-resolution spectrometer. Here we discuss the SXS detector subsystem that includes the detector array, the anticoincidence detector, the first stage amplifiers, the thermal and mechanical staging of the detector, and the cryogenic bias electronics. The design of the SXS detector subsystem has significant heritage from the Suzaku/XRS instrument but has some important modifications that increase performance margins and simplify the focal plane assembly. Notable improvements include x-ray absorbers with significantly lower heat capacity, improved load resistors, improved thermometry, and a decreased sensitivity to thermal radiation. These modifications have yielded an energy resolution of 3.5-4.0 eV FWHM at 6 keV for representative devices in the laboratory, giving considerable margin against the 7 eV instrument requirement. We expect similar performance in flight

Porter, Frederick↗

Preliminary Design of the Continuous ADRs for the Primordial Inflation Explorer (PIXIE)

PIXIE is a recently proposed middle-class explorer mission designed to produce full-sky maps of polarization in the Cosmic Microwave Background (CMB). PIXIEs challenging science goals require not only measuring the extremely faint b-modes of the CMB, but distinguishing between true CMB signatures and 1) polarized light reflecting off local dust, and 2) signals arising from within the instrument. PIXIEs detectors will operate at 100 mK in order to achieve the required sensitivity. Instrument errors will be minimized in part by operating the telescope and optics at an average temperature close to that of the CMB (2.72 K) and systematically varying the temperature of various components by a small amount (10-20 mK). Signals appearing at the frequency of those variations can then be subtracted out. For this to be successful at the level required, it is necessary for the pattern of temperatures to be stable over very long time frames. Consequently, cooling of the detectors and telescope will be done using two 3-stage ADR assemblies that will produce continuous cooling, one at 100 mK and the other at approximately 2.65 K. The latter will act as the heat sink for 100 mK ADR and establish a base temperature from which the telescope and optics will be regulated. Its heat sink is a 4.5 K cryocooler. The design and operation of the ADRs will be discussed.

magnetic refrigeration↗

Design and Performance of the Astro-E/XRS Microcalorimeter Array and Anti-Coincidence Detector

The XRS instrument has an array of 32 micro-calorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of 9 eV at 3 keV and 11 eV at 6 keV. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, operating temperature, thermistor size, absorber choice, and means of attaching the absorber to the thermistor bearing element. We will present representative performance data, though a more detailed presentation of the results of the instrument calibration is presented elsewhere in these proceedings. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance in conjunction with the array.

Stahle, C. K.↗

A new Fabry-Perot spectrometer for observations of diffuse near-infrared line emission

We describe a new Fabry-Perot spectrometer that is optimized for the detection of extended, low-surface-brightness line emission from 1.4 to 2.4 microns. The instrument combines high throughput and high sensitivity, yet limits the background radiation falling on the detector. The instrument has a single 20 sec - 200 sec beam and a resolving power lambda/delta(lambda) approximately 2500. The system is background shot-noise limited in the K window and limited by a combination of read noise, dark-current shot noise, and fluctuations in the OH airglow lines in the H window. We present sample data of some of the lowest-surface-brightness H2 line emission in the near infrared obtained to date.

Luhman, M. L.↗

James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

JWST Thermal Core 2 Test↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

Using Lunar Observations to Validate Pointing Accuracy and Geolocation, Detector Sensitivity Stability and Static Point Response of the CERES Instruments

Validation of in-orbit instrument performance is a function of stability in both instrument and calibration source. This paper describes a method using lunar observations scanning near full moon by the Clouds and Earth Radiant Energy System (CERES) instruments. The Moon offers an external source whose signal variance is predictable and non-degrading. From 2006 to present, these in-orbit observations have become standardized and compiled for the Flight Models -1 and -2 aboard the Terra satellite, for Flight Models-3 and -4 aboard the Aqua satellite, and beginning 2012, for Flight Model-5 aboard Suomi-NPP. Instrument performance measurements studied are detector sensitivity stability, pointing accuracy and static detector point response function. This validation method also shows trends per CERES data channel of 0.8% per decade or less for Flight Models 1-4. Using instrument gimbal data and computed lunar position, the pointing error of each detector telescope, the accuracy and consistency of the alignment between the detectors can be determined. The maximum pointing error was 0.2 Deg. in azimuth and 0.17 Deg. in elevation which corresponds to an error in geolocation near nadir of 2.09 km. With the exception of one detector, all instruments were found to have consistent detector alignment from 2006 to present. All alignment error was within 0.1o with most detector telescopes showing a consistent alignment offset of less than 0.02 Deg.

Daniels, Janet L.↗

Submillimeter and Far Infrared Experiment for SOFIA (SAFIRE): Progress and Prospects

SAFIRE/SOFIA is a versatile imaging Fabry-Perot spectrograph covering 100 less than lambda less than 655 microns, with spectral resolving power of approx. l0(exp 3). Selected as a "PI" instrument for the airborne Stratospheric Observatory for Infrared Astronomy (SOFIA), SAFIRE will apply two dimensional pop-up bolometer arrays to provide background limited imaging spectrometry. We describe the instrument design, its application to a range of astro- physical investigations, and current progress and results in the innovative detector and instrument design. SAFIRE/SOFIA is on track for availability in 2006.

Shafer, R. A.↗

Nuclear Spectroscopic Telescope Array (NuSTAR) Mission

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a National Aeronautics and Space Administration (NASA) Small Explorer mission that carried the first focusing hard X-ray (6-79 keV) telescope into orbit. It was launched on a Pegasus rocket into a low-inclination Earth orbit on June 13, 2012, from Reagan Test Site, Kwajalein Atoll. NuSTAR will carry out a two-year primary science mission. The NuSTAR observatory is composed of the X-ray instrument and the spacecraft. The NuSTAR spacecraft is three-axis stabilized with a single articulating solar array based on Orbital Sciences Corporation's LEOStar-2 design. The NuSTAR science instrument consists of two co-aligned grazing incidence optics focusing on to two shielded solid state CdZnTe pixel detectors. The instrument was launched in a compact, stowed configuration, and after launch, a 10-meter mast was deployed to achieve a focal length of 10.15 m. The NuSTAR instrument provides sub-arcminute imaging with excellent spectral resolution over a 12-arcminute field of view. The NuSTAR observatory will be operated out of the Mission Operations Center (MOC) at UC Berkeley. Most science targets will be viewed for a week or more. The science data will be transferred from the UC Berkeley MOC to a Science Operations Center (SOC) located at the California Institute of Technology (Caltech). In this paper, we will describe the mission architecture, the technical challenges during the development phase, and the post-launch activities.

Telescope↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

Zodiacal light dynamics experiment: A wideband imaging Fabry-Perot interferometer

The Solar Probe will provide an ideal platform from which to study dynamics of dust particles near the sun by measuring the detailed character of the Fraunhofer structure of the zodiacal light. The suggested instrument is a wideband imaging Fabry-Perot interferometer with state of the art technology in both the optics and the detector. The instrument would function as a high-resolution imaging device providing wavelength resolution of 0.03 A over about a 20 A range. The wideband imaging capability would provide sky maps of the zodiacal light on a despun spacecraft without mechanical scanning. The Solar Probe mission would allow the velocity distribution of the dust to be mapped along most of the trajectory of the spacecraft.

Torr, D. G.↗

Data inversion algorithm development for the hologen occultation experiment

The successful retrieval of atmospheric parameters from radiometric measurement requires not only the ability to do ideal radiometric calculations, but also a detailed understanding of instrument characteristics. Therefore a considerable amount of time was spent in instrument characterization in the form of test data analysis and mathematical formulation. Analyses of solar-to-reference interference (electrical cross-talk), detector nonuniformity, instrument balance error, electronic filter time-constants and noise character were conducted. A second area of effort was the development of techniques for the ideal radiometric calculations required for the Halogen Occultation Experiment (HALOE) data reduction. The computer code for these calculations must be extremely complex and fast. A scheme for meeting these requirements was defined and the algorithms needed form implementation are currently under development. A third area of work included consulting on the implementation of the Emissivity Growth Approximation (EGA) method of absorption calculation into a HALOE broadband radiometer channel retrieval algorithm.

Gordley, Larry L.↗

Imaging Technique for High Precision Measurement of Detector Stability for the Ocean Color Instrument

One of the new projects by NASA to explore environmental change is the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft. The primary instrument aboard the PACE spacecraft is the Ocean Color Instrument (OCI), an advanced optical spectrometer that will measure the color of the ocean from the ultraviolet to shortwave infrared range for the purpose of observing and monitoring ocean and coastal biology. As part of the optical alignment testing that must be completed before the instrument is built, the measurement stability of the detectors at space flight operating temperatures must be determined to ensure alignment is maintained. Therefore, this project focuses on the development of an imaging technique that adheres to testing requirements and can be used to determine the stability of the OCI detector. The movements of targets affixed to a high-precision stage were analyzed through an image processing program to test the ability of the imaging technique to detect very small (under 10 micrometers) movements. It was found that movements as small as half a pixel (~6 microns) and 1 pixel (~12 microns) were able to be accurately and consistently detected with this imaging technique. This project found that the designed image analysis technique fulfills testing and measurement requirements and will be an effective metrology technique for the OCI detector stability test.

Optics↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

MSL-RAD Cruise Operations Concept

The Mars Science Laboratory (MSL) payload includes the Radiation Assessment Detector (RAD) instrument, intended to fully characterize the radiation environment for the MSL mission. The RAD instrument operations concept is intended to reduce impact to spacecraft resources and effort for the MSL operations team. By design, RAD autonomously performs regular science observations without the need for frequent commanding from the Rover Compute Element (RCE). RAD operates with pre-defined "sleep" and "observe" periods, with an adjustable duty cycle for meeting power and data volume constraints during the mission. At the start of a new science observation, RAD performs a pre-observation activity to assess count rates for selected RAD detector elements. Based on this assessment, RAD can enter "solar event" mode, in which instrument parameters (including observation duration) are selected to more effectively characterize the environment. At the end of each observation period, RAD stores a time-tagged, fixed length science data packet in its non-volatile mass memory storage. The operating cadence is defined by adjustable parameters, also stored in non-volatile memory within the instrument. Periodically, the RCE executes an on-board sequence to transfer RAD science data packets from the instrument mass storage to the MSL downlink buffer. Infrequently, the RAD instrument operating configuration is modified by updating internal parameter tables and configuration entries.

Mars Science Laboratory (MSL)↗

Experiments D004 and D007: Celestial radiometry and space object radiometry

Two interferometer spectrometers and a multichannel spectroradiometer were used as sensing instruments during the Gemini 5 and 7 missions. The selection of the instruments and of the particular detectors in the instruments was based upon the spectral bands to be investigated in each flight and upon the nature of the intended measurements. The instrument characteristics were a compromise among optimization for a particular type of measurement, a need for a broad selection of spectral information, and performance and other pertinent characteristics of the spacecraft. Data were collected on earth background, sky background, rocket exhaust plumes, celestial bodies, man made objects in space, weather phenomena, and spectral calibrations.

Lovett, J.↗