Novel Horn Designs for Power Ultrasonics

Ultrasonic horns are used in a variety of industrial and medical applications. At JPL a rock-sampling tool based on an ultrasonic horn was developed to drill, abrade and core rock samples including hard basalts. This device is an impact device, which uses ultrasonic vibratlons that occur at the horn tip to produce a sonic resonance with the aid of a loosely connected mass. Although standard horns are found in many current industrial designs they suffer from a few key limitations when used for USDC applications. Manufacturing a horn requires turning down stock material (e.g. Titanium) from the larger outer diameter to the horn tip diameter, and this process is both time consuming and wasteful. In this paper, we present novel horn designs that are specifically designed for impact applications as the USDC. One such design addressed the excasive length that is involved with the use of the horn limiting its applications when system dimensions are constrained. For this purpose, a folded horn design was conceived that reduces the overall length of the resonator (physical length) but maintains or increases the acoustic length. Initial experiments with horns having such P design indicate that the tip displacement can be further adjusted by phasing the bending displacements and the extensional displacements. Another conceived horn design is the 'dog bone' horn that uses an end mass on the horn tip io increase the impact efficiency of the horn. In this paper, the experimental results for these novel born designs are presented and compared to the results predicted by theory.

acutators↗

Computer-Based Procedures Among Older Adults: Findings from the Rancor Microworld Simulator

As with many industries worldwide, nuclear energy is experiencing an aging workforce; older than other energy sources and the national average. For example, while almost one in three nuclear industry professionals are 55+ years, for oil and gas that number is one in five. The challenges brought about by an aging workforce are one of the industry’s top concerns. However, the industry lacks for empirical research that examines the effects of developmental aging in older workers, as well as the interactions between aging and new digital technologies. We present the results of an experiment that tested three different computer-based procedures in a sample of 30 older adults (55+ years). While the industry has traditionally relied on paper-based procedures, these are being modernized by digital technology. Participants were randomly assigned to one of three procedure-types that varied by the level of digitalization, based on the IEEE Standard-1786. Type 1 essentially represents a digital representation of a paper-based procedure, Type 2 adds embedded indicators, and Type 3 adds soft controls. Participants performed two different operational scenarios (startup and loss of feedwater) on a simplified nuclear power plant simulator. Results revealed a weak signal that Type 2 may produce lower workload and lower completion times in some instances. However, there were no significant effects of procedure-type across any other outcomes, including simulator log data, situation awareness, and preference ratings. We discuss our findings in terms of optimal levels of digitalization/automation for an aging nuclear workforce and suggest pathways for future directions.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Prediction of swirling reacting flow in ramjet combustors

Numerical computations have been undertaken for a basic two-dimensional axisymmetric flowfield which is similar to that found in conventional gas turbine and ramjet combustors. A swirling flow enters a larger chamber via a sudden or gradual expansion. The calculation method involves a staggered grid system for axial and radial velocities, a line relaxation procedure for efficient solution of the equations, a two-equation turbulence energy-turbulence dissipation rate turbulence model, a stairstep boundary representation of the expansion flow, and realistic accommodation of swirl effects. The results include recirculation zone characterization and predicted mean streamline patterns. Predictions with and without chemical reaction are obtained. An associated isothermal experimental flow study is providing a useful data base. Successful outcomes of the work can be incorporated into the more combustion- and hardware-oriented activities of industrial concerns.

Lilley, D. G.↗

Overview of the Capture, Containment, and Return System (CCRS)

The Mars Sample Return (MSR) campaign is one of the most ambitious and complex planetary exploration missions currently underway. With the participation of NASA, ESA, and a large number of industry partners, MSR aims to bring Martian soil, rock, and atmospheric samples back to Earth, in order to answer key questions about Mars’ biological evolution. To accomplish this goal the campaign relies on four coordinated missions, each fulfilling a fundamental role to bring the samples to Earth. The Mars Perseverance rover, the first of the four missions, landed safely on Mars on February 18, 2021 and has already acquired candidate samples for Earth return. A selection of the samples of Martian soil and atmosphere that Perseverance has captured during its mission will be recovered, launched into Mars orbit, and transported back to Earth. The Sample Fetch Rover and Mars Ascent System, both parts of the Sample Return Lander project, perform the Mars surface missions to retrieve the collected samples and launch them into Mars orbit. NASA’s Capture, Containment, and Return System (CCRS), hosted on ESA’s Earth Return Orbiter (ERO), brings the samples back to Earth from Mars orbit. These retrieval and return missions are currently in the planning and design stages of development. The NASA-provided CCRS is the payload of the ESA ERO and is the focus of this presentation. ERO will enter Mars orbit and provide communication relay to Earth for the other MSR elements. The Sample Return Lander systems will fetch the sample tubes and integrate them into a protective vessel – the Orbiting Sample (OS) system – which is then launched into low Mars orbit. ERO will perform rendezvous maneuvers, allowing its CCRS payload to capture the OS, contain it, and perform the first automated in-space assembly of a spacecraft, the Earth Entry System (EES), while in Mars orbit. ERO will then begin its journey back to Earth, with CCRS and its assembled EES spacecraft. Three days prior to arrival, CCRS will release the EES on an Earth entry trajectory from a distance beyond the orbit of the Moon. The passive EES spacecraft will then enter Earth’s atmosphere, flying on a ballistic trajectory, followed by a terminal descent (without a parachute) and landing at the Utah Test and Training Range (UTTR). This presentation will show the current design of the CCRS system and its concept of operations. ERO and CCRS will perform several firsts in planetary exploration: (a) orbital rendezvous and capture in Mars orbit, (b) in-space sterilization and containment, (c) on-orbit spacecraft assembly at Mars, and (d) fully-passive entry, descent, and landing sequence for sample return.

Carlie H. Zumwalt↗

Mars Sample Return and The Capture, Containment, and Return System New Design and Path To 2027 Launch

The Mars Sample Return (MSR) campaign is one of the most ambitious and complex exoplanet scientific exploration missions currently underway. With the participation of NASA, ESA, and a large number of industry partners, MSR aims to bring back Martian rock and atmosphere samples with the goal of answering key questions about Mars’ geological, climatological, and (potentially) biological evolution. To accomplish this ambitious goal, the campaign relies on three distinct flight elements and a ground element. The Earth Return Orbiter (ERO) mission that would host the Capture, Containment, and Return System (CCRS) is the last element of the trio. The mission would capture the orbiting sample in low Mars orbit (launched into orbit by another mission), contain it and return it to Earth, landing it at the Utah Test and Training Range (UTTR). The CCRS continues its development. Since its early architecture, several changes were adopted by the project in order to improve overall payload efficiency and reduce mass. CCRS is currently on track to achieve the next milestone, Critical Design Review, expected in late 2024. This paper will discuss the CCRS design, how the current architecture contributes to an improved mission baseline, and the next critical steps of the mission towards its launch.

Mars mission↗

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Degradable Biocomposite Thermoplastic Polyurethanes

In this project, the team developed tough and degradable biocomposite thermoplastic polyurethanes (TPUs) by incorporating bacterial spores into TPUs as a biofunctional living filler. The team screened various bacteria and selected the Bacillus subtilis ATCC 6633 strain as the final candidate, primarily due to its genomic availability, sporulation ability and TPU assimilation activity. The heat-shock tolerance of ATCC 6633 spores was further improved through evolutionary engineering via Adaptive Laboratory Evolution (ALE), demonstrating a 17.7-fold enhanced germination efficiency post heat-shock treatment compared to the wild-type strain (WT). The team fabricated biocomposite TPUs by incorporating lyophilized powder of heat-shock tolerized (HST) spores during the hot melt extrusion (HME) of TPU at 135 °C. The baseline TPU used in this project is a commercially available soft-grade TPU (BCF45) manufactured by BASF. Colony forming unit (CFU) assays quantified that WT and HST spores in the TPU matrix retained approximately 20% and 100% survivability, respectively, after HME. Tensile testing demonstrated that the spores behaved as a polymer-reinforcing filler, positively affecting the overall tensile properties of the biocomposite TPU. For example, biocomposite TPU with WT and HST spores (BC TPU WT and BC TPU HST , respectively) exhibited up to 25% and 37% improved toughness, respectively, compared to TPU without spores. BC TPU HST showed remarkably improved disintegration in autoclaved compost (92% mass loss in 5 months), which simulated a microbially poor environment for TPU degradation. When compared to TPU without spores (44% mass loss in 5 months) the acceleration of degradation is marked. Respirometry confirmed that 72% of BC TPU HST was biomineralized into CO2 within 6 months, indicating that spores in the biocomposite TPU were germinated by utilizing nutrients in the autoclaved compost, facilitating TPU degradation at the end of the material's life. The team demonstrated the scale-up of biocomposite TPU fabrication using continuous extrusion and injection molding techniques. Processing conditions optimized in a lab-scale microcompounder were successfully transferred to a continuous extruder with a 30-fold increased throughput. Biocomposite TPUs prepared using these industry-relevant processes showed comparable toughness improvements to samples prepared in the lab-scale extruder. Excitingly, following compounding in the pilot-extruder the composite material could be injection molded, while retaining high spore viability and similar toughness improvements. The team also found that spores in biocomposite TPU served as antioxidants, preventing toughness decay during the recycled extrusion of BC TPU HST . Long-term storage tests over one year showed that the addition of spores had no negative effect on the longevity of the TPU. Furthermore, the team demonstrated the fabrication of spore-bearing biocomposite polymers with other polyesters such as PBAT, PLA, and PCL. We obtained promising preliminary data that showed overall toughness improvements for all polymers with spore addition. Finally, life cycle assessment (LCA) and techno-economic analysis (TEA) were carried out, which indicated minimal additional cost of fabrication. Overall, a tough and degradable biocomposite thermoplastic was successfully developed through this project, with all tasks completed successfully, achieving >100% of the objectives.

36 MATERIALS SCIENCE↗

Modeling Code Is Helping Cleveland Develop New Products

Master Builders, Inc., is a 350-person company in Cleveland, Ohio, that develops and markets specialty chemicals for the construction industry. Developing new products involves creating many potential samples and running numerous tests to characterize the samples' performance. Company engineers enlisted NASA's help to replace cumbersome physical testing with computer modeling of the samples' behavior. Since the NASA Lewis Research Center's Structures Division develops mathematical models and associated computation tools to analyze the deformation and failure of composite materials, its researchers began a two-phase effort to modify Lewis' Integrated Composite Analyzer (ICAN) software for Master Builders' use. Phase I has been completed, and Master Builders is pleased with the results. The company is now working to begin implementation of Phase II.

Source record↗

Aligned Carbon Nanotube Tape for Sensor Applications

For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical properties CNT tape as a strain gauge in Structural Health Monitoring will provide an excellent material to embed within composite structures

Tucker, Dennis S.↗

Evaluation of Surlyn 8920 as PHE Visor Material and Evaluations of New Adhesives for Improving Bonding Between Teflon and Stainless Steel at Cryogenic Temperature

Two studies are presented, and in the first study, Surlyn 8920 (an ionic and amorphous low density polyethylene made by Dupont) was evaluated as a possible replacement of Plexyglass G as PHE visor material. Four formulations of the polymer were made by adding different amounts of UV stabilizer, energy quencher, and antioxident in a Brabender Plasticorder. The formulated polymers were molded in the form of sheets in a compression molder. Cut samples from the molded sheets were exposed in a weatherometer and tested on Instron Tensile Tester for strength and elongation. Specially molded samples of the formulated polymers were subjected to Charpy Impact Tests. In the second study, preliminary evaluations of adhesives for improvement of bonding between Teflon and stainless steel (SS) were performed. Kapton, a high temperature polyimide made by Dupont, and a rubber based adhesive made by Potter Paint Co., were evaluated against industrial quality epoxy, the current material used to bond Teflon and SS. The degreased surfaces of the SS discs were etched mechanically, with a few of these etched chemically. The surfaces of the SS discs were etched mechanically, with a few of these etched chemically. Bonding strengths were evaluated using lap shear tests on the Instron Tensile Tester for the samples bonded by Kapton and industrial quality epoxy. Bond strengths were also evaluated using a pull test on the Instron for the samples bonded by Potter adhesive (CWL-152) and industrial quality epoxy. Based on limited lap shear data, Kapton gave bond strength favorable compared to that of industrial epoxy. Based on limited pull test data, Kapton bonded and CWL-152 bonded samples showed poor strength compared to epoxy bonded sample.

Ray, Asit K.↗

Mars sample return, updated to a groundbreaking approach

During 2001, NASA issued contracts to four industry teams to conduct broad trade studies of what they envisioned to be the best implementation of MSR and subsequently tasked with focusing on a specific concept, fleshing-out a specific design concept.

Mars sample return↗

Gravitational macrosegregation in binary Pb-Sn alloy ingots

A space shuttle experiment employing the General Purpose (Rocket) Furnace (GPF) in its isothermal mode of operation is manifested on MSL-3, circa 1989. The central aim of this experiment is to investigate the effect of reduced gravity levels on the segregation behavior in a slowly, and isothermally, cooled sample of a binary Pb-15 wt% Sn alloy. This experiment should be able to simulate, in a small laboratory sample, some aspects of the segragation phenomena occurring in large industrial ingots. Ground-based experiments conducted in the single-cavity simulator of the GPF, in support of the microgravity experiment are described in detail. The results of the MSFC experiments are compared with other related experiments conducted at Case Western Reserve University (CWRS), wherein the isothermal constraints were relaxed. The isothermally processed samples indicate a small and gradual increase in fraction eutectic, and a corresponding increase in tin content, from the bottom to the top of the ingot. The radial variations are minimal near the ingot bottom, but there are large radial variations in the top half. In the CWRU experiments, more severe segregations, including segregation defects known as freckles. Follow up experiments employing the GPF without the isothermal constraints, or other suitably modified space shuttle hardware are suggested.

Laxmanan, V.↗

Gravitational macrosegregation in binary Pb-Sn alloy ingots

A space shuttle experiment employing the General Purpose (Rocket) Furnace (GPF) in its isothermal mode of operation is manifested on MSL-3, circa 1989. The central aim of this experiment is to investigate the effect of reduced gravity levels on the segregation behavior in a slowly, and isothermally, cooled sample of a binary Pb-15 wt pct Sn alloy. This experiment should be able to simulate, in a small laboratory sample, some aspects of the segregation phenomena occurring in large industrial ingots. Ground-based experiments conducted in the single-cavity simulator of the GPF, in support of the microgravity experiment are described in detail. The results of the MSFC experiments are compared with other related experiments conducted at Case Western Reserve University (CWRS), wherein the isothermal constraints were relaxed. The isothermally processed samples indicate a small and gradual increase in fraction eutectic, and a corresponding increase in tin content, from the bottom to the top of the ingot. The radial variations are minimal near the ingot bottom, but there are large radial variations in the top half. In the CWRU experiments, more severe segregations, including segregation defects known as freckles. Follow up experiments employing the GPF without the isothermal constraints, or other suitably modified space shuttle hardware are suggested.

Laxmanan, V.↗

Cybersonics: Tapping into Technology

With the assistance of Small Business Innovation Research (SBIR) funding from NASA's Jet Propulsion Laboratory, Cybersonics, Inc., developed an ultrasonic drill with applications ranging from the medical industry to space exploration. The drill, which has the ability to take a core sample of the hardest granite or perform the most delicate diagnostic medical procedure, is a lightweight, ultrasonic device made to fit in the palm of the hand. Piezoelectric actuators, which have only two moving parts and no gears or motors, drive the components of the device, enabling it to operate in a wide range of temperatures. The most remarkable aspect of the drill is its ability to penetrate even the hardest rock with minimal force application. The ultrasonic device requires 20 to 30 times less force than standard rotating drills, allowing it to be safely guided by hand during operation. Also, the drill is operable at a level as low as three watts of power, where conventional drills require more than three times this level. Potential future applications for the ultrasonic drill include rock and soil sampling, medical procedures that involve core sampling or probing, landmine detection, building and construction, and space exploration. Cybersonics, Inc. developed an ultrasonic drill with applications ranging from the medical industry to space exploration.

Source record↗

A Methodology for determining optimal milling parameters for low-taper microtensile sample production

Femtosecond lasers are beginning to see an increase in interest for industrial and high throughput microsample milling applications. Despite this, much of the literature regarding removal rate studies for ultrashort pulse laser milling continues to focus on single-pulse or similar experiments that have a very small time on target. The material volume removal rates of femtosecond milling can vary wildly depending on parameters like laser scan speed, hatch spacing, z-axis step size, and pulses on the material. Currently, there is no established methodology for determining the optimal values of these parameters for micromilling applications. This methodology was developed in this study. The methodology consists of a pulse study, a repeat study, and a z-step study that will return the milling parameters that resulted in the largest volume removal rate for the laser used for this research. The methodology was created for the laser system used in this study, and was tested on 316 Stainless Steel, but was developed in such a way that it may be adapted to any material, and with some tweaking of variables might be used in other laser systems. The laser system used in this study utilizes a novel positioning stage that introduces 6 degrees of freedom to the translation of laser samples, being able to tilt and move in all three axes. Using both the developed methodology and the unique capabilities of the laser microtensile samples were produced with taper angles of <1° in 316 Stainless Steel.

Barker, Zachary Wayne↗

Geochemical assessment of mineral sequestration of carbon dioxide in the midcontinent rift

Abstract This study examines the potential of Midcontinent Rift rocks to facilitate long‐term CO 2 sequestration by providing the necessary Ca and Mg for carbonate mineralization. Surface samples were collected from the Oronto and Bayfield‐Jacobsville Groups around Lake Superior and used for petrography and X‐ray diffraction to determine their mineral composition. Also, X‐ray fluorescence was also used to assess their bulk chemical composition. The samples were then exposed to CO 2 and deionized water in Teflon‐lined vessels at 90°C, and the resulting leachate fluids were analyzed for the cation released during the testing. SEM microscopy was used to examine the samples for potential mineralization of carbonate minerals. The Oronto Group sediments consist primarily of feldspathic to feldspathic lithic arenites with a chlorite‐dominated matrix, and the primary porosity is blocked by calcite and hematite cement. The Bayfield–Jacobsville sequences are porous quartz arenites to feldspathic quartz arenites that do not contain significant accumulation of Ca‐, Mg‐, and Fe‐bearing minerals. The leachate fluids obtained from Oronto Group samples exhibit a maximum Ca release rate (5.2 × 10 −4 mole/cm 2 .day), indicating rapid calcite cement dissolution and increased porosity and permeability. SEM/EDS microanalysis revealed areas where pore‐filling calcite was preferentially dissolved. Longer‐term rock‐water reactions resulted in induced carbonate mineralization, as evidenced by calcite crystals observed in a sample reacted for 102 days. © 2024 Society of Chemical Industry and John Wiley & Sons, Ltd.

Energy & Fuels↗