Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Neutron Scattering Instrumentation Research and Development for High Spatial and Temporal Resolution Imaging at Oak Ridge National Laboratory

Neutron scattering facilities like those available at ORNL are enabling the discovery and development of advanced materials include those to be used for next generation energy storage systems. In spite of all the success that neutron imaging has enjoyed in recent years, even higher-impact research is limited by the current temporal and spatial resolution of neutron detection devices. In particular, the spatial resolution of all neutron imaging methods in use and under development is fundamentally limited by the variance introduced by the charged particles emitted from neutron absorption. Thus, we are investigating, designing and demonstrating an array of ~1 micron-sized glass scintillating fibers arranged via photonics-crystal-fiber patterning techniques-- with particle tracking (a must) so that position resolution can be finer than than that allowed by the charged particle ranges. The processes, knowledge and algorithms developed will allow for spatially (1 micron) and time resolved (<100 ns), high throughput neutron transmission imaging in large areas at reasonable costs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Novel Heating Technology for Ultra-High Resolution Imaging in Electron Microscopes

Capabilities for in-situ studies of materials at elevated temperatures and under gaseous environments have received increasing attention in recent years [1]. With the advent of electron microscopes that provide routine imaging at the atomic level (e.g. aberration-corrected TEM and STEM instruments), it is of particular interest to be able to record images at high temperatures while retaining the inherent resolution of the microscope; that is, the resolution is not limited by drift in the heating holder or other instabilities associated with its operation. Furthermore, there are a number of commercial and experimental heating devices that have been used over the years; some holders are designed with miniature furnaces that heat entire grids [2], while a more recent development used a tiny spiral filament coated with a carbon film as the heater element [3]. These devices, while very useful for some applications (particularly in environmental microscopes that employ differential pumping to allow gases at some elevated pressure to be injected around the specimen), are invariably not as stable as might be desired for sub- Angstrom imaging experiments. The speed at which the sample can be heated to temperature for stable operation also limits them. In collaboration with Protochips Inc. (Raleigh, NC), our laboratory is developing a novel new technology for in-situ heating experiments that overcomes a number of performance problems associated with standard heating stage technologies [4].

36 MATERIALS SCIENCE↗

First results from IRENI - Rapid diffraction-limited high resolution imaging across the mid-infrared bandwidth

First results from IRENI, a new beamline at the Synchrotron Radiation Center, demonstrate that synchrotron chemical imaging, which combines the characteristics of bright, stable, broadband synchrotron source with a multi-element detector, produces diffraction-limited images at all wavelengths simultaneously. A single cell of Micrasterias maintained in a flow cell has been measured, and results show high quality spectra and images demonstrating diffraction limited, and therefore wavelength-dependent, spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vision 20/20: Increased image resolution versus reduced radiation exposure

This is a review of methods, currently and potentially, available for significantly reducing x-ray exposure in medical x-ray imaging. It is stimulated by the radiation exposure implications of the growing use of helical scanning, multislice, x-ray computed tomography for screening, such as for coronary artery atherosclerosis and cancer of the colon and lungs. Screening requires high-throughput imaging with high spatial and contrast resolution to meet the need for high sensitivity and specificity of detection and classification of specific imaged features. To achieve this goal beyond what is currently available with x-ray imaging methods requires increased x-ray exposure, which increases the risk of tissue damage and ultimately cancer development. These consequences limit the utility of current x-ray imaging in screening of at-risk subjects who have not yet developed the clinical symptoms of disease. Current methods for reducing x-ray exposure in x-ray imaging, mostly achieved by increasing sensitivity and specificity of the x-ray detection process, may still have potential for an up-to-tenfold decrease. This could be sufficient for doubling the spatial resolution of x-ray CT while maintaining the current x-ray exposure levels. However, a spatial resolution four times what is currently available might be needed to adequately meet the needs for screening. Consequently, for the proposed need to increase spatial resolution, an additional order of magnitude of reduction of x-ray exposure would be needed just to keep the radiation exposure at current levels. This is conceivably achievable if refraction, rather than the currently used attenuation, of x rays is used to generate the images. Existing methods that have potential for imaging the consequences of refracted x ray in a clinical setting are (1) by imaging the edge enhancement that occurs at the interfaces between adjacent tissues of different refractive indices, or (2) by imaging the changes in interference patterns resulting from moving grids which alter the refraction of x rays, that have passed through the body, in a predictable fashion, and (3) theoretically, by an image generated from the change in time-of-flight of x-ray photons passing through the body. Imaging phase shift or change in time-of-flight, rather than attenuation, of x-ray photons through tissues presents formidable technological problems for whole-body 3D imaging. However, if achievable in a routine clinical setting, these approaches have the potential for greatly expanding the use of x-ray imaging for screening. This overview examines the increased contrast resolution and reduced radiation exposure that might be achievable by the above-mentioned methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HIGH-RESOLUTION IMAGING OF THE GEGENSCHEIN AND THE GEOMETRIC ALBEDO OF INTERPLANETARY DUST

We performed optical observations of the Gegenschein using a liquid-nitrogen-cooled wide-field camera, the Wide-field Imager of Zodiacal light with ARray Detector (WIZARD), between 2003 March and 2006 November. We found a narrow brightness enhancement superimposed on the smooth gradient of the Gegenschein at the exact position of the antisolar point. Whereas the Gegenschein morphology changed according to the orbital motion of the Earth, the maximum brightness coincided with the antisolar direction throughout the year. We compared the observed morphology of the Gegenschein with those of models in which the spatial density of the interplanetary dust cloud was considered and found that the volume scattering phase function had a narrow backscattering enhancement. The morphology was reproducible with a spatial distribution model for infrared zodiacal emission. It is likely that the zero-phase peak (the so-called opposition effect) was caused by coherent backscattering and/or shadow-hiding effects on the rough surfaces of individual dust particles. These results suggest that big particles are responsible for both zodiacal light and zodiacal emission. Finally, we derived the geometric albedo of the smooth component of interplanetary dust, assuming big particles, and obtained a geometric albedo of 0.06 {+-} 0.01. The derived albedo is in accordance with collected dark micrometeorites and observed cometary dust particles. We concluded that chondritic particles are dominant near Earth space, supporting the recent theoretical study by dynamical simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time atomic-resolution imaging of crystal growth process in water by phase modulation atomic force microscopy at one frame per second

Recent advancement in dynamic-mode atomic force microscopy (AFM) has enabled its operation in liquid with atomic-scale resolution. However, its imaging speed has often been too slow to visualize atomic-scale dynamic processes. Here, we propose a method for making a significant improvement in the operation speed of dynamic-mode AFM. In this method, we use a wideband and low-latency phase detector with an improved algorithm for the signal complexification. We demonstrate atomic-scale imaging of a calcite crystal growth process in water at one frame per second. The significant improvement in the imaging speed should enable various studies on unexplored atomic-scale interfacial processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localization of Nonblinking Point Sources Using Higher-Order-Mode Detection and Optical Heterodyning: Developing a Strategy for Extending the Scope of Molecular, Super-resolution Imaging

While the stochastic, “blinking” nature of fluorescent systems has enabled the super-resolution of their localization by the fitting of their point-spread functions (PSFs), this strategy cannot be exploited for similar resolution of “nonblinking” systems, such as those that might be encountered in a coherent Raman experiment. An alternative method for subdiffraction-limited imaging lies in the exploitation of optical heterodyning. For example, if a Gaussian PSF (a TEM00 mode) of a point emitter is displaced with respect to the origin of the optical system, photons in the higher-order TEM modes carry information about that displacement. Information concerning the displacement can be extracted from photons in these higher-order modes. These photons can be collected by optical heterodyning, which exploits the large gain in a detector’s response to an optical signal from an emitter coupled to a local oscillator, which is prepared in the TEM of interest, e.g., TEM10. We have generalized and developed the heterodyning technique to localize point emitters via the detection of higher-order spatial modes. We have developed a theoretical approach to find a practical estimation limit of the localization parameters using a realistic model that accounts for shot noise, background noise, and Gaussian noise. To demonstrate the applicability of the method, we designed experiments in which a laser is a surrogate for one and two point emitters. Using the Fisher information and its accompanying Cramér-Rao lower bound, we demonstrate super-resolution localization in these cases: we show that objects can be localized to roughly 2–3 orders of magnitude of their point-spread function’s size for a given optical system. Finally and most importantly, it is suggested that the results will ultimately be generalizable to multiple emitters and, most importantly, to “nonblinking” molecular systems, which will be essential for broadening the scope of super-resolution measurements beyond the limits of fluorescence-based techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution imaging of very low mass spectral binaries: Three resolved systems and detection of orbital motion in an L/T transition binary

We present high resolution Laser Guide Star Adaptive Optics imaging of 43 late-M, L and T dwarf systems with Keck/NIRC2. These include 17 spectral binary candidates, systems whose spectra suggest the presence of a T dwarf secondary. We resolve three systems: 2MASS J1341–3052, SDSS J1511+0607 and SDSS J2052–1609; the first two are resolved for the first time. All three have projected separations <8 AU and estimated periods of 14–80 years. We also report a preliminary orbit determination for SDSS J2052–1609 based on six epochs of resolved astrometry between 2005 and 2010. Among the 14 unresolved spectral binaries, 5 systems were confirmed binaries but remained unresolved, implying a minimum binary fraction of 47{sub −11}{sup +12}% for this sample. Our inability to resolve most of the spectral binaries, including the confirmed binaries, supports the hypothesis that a large fraction of very low mass systems have relatively small separations and are missed with direct imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple elastic scattering of core-loss electrons in atomic resolution imaging

We consider the elastic scattering of a fast incident electron both prior and subsequent to its involvement in an atomic inner-shell ionization (core-loss) event in a crystal. By using numerical simulations, it is shown that elastic scattering subsequent to ionization can strongly affect the qualitative features of atomic resolution core-loss images of crystals recorded in the scanning transmission electron microscope (STEM). This conclusion holds even for a thin crystal foil and for a relatively large detector, which is matched to the probe-forming aperture in an aberration-corrected STEM. Such a conclusion is potentially very important for the interpretation of experimental core-loss images. We also introduce an approximate model that incorporates the effects of elastic scattering subsequent to ionization in the case of a small detector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison between beamforming and super resolution imaging algorithms for non-destructive evaluation

In this paper the performance of total focusing method is compared with the widely used time-reversal MUSIC super resolution technique. The algorithms are tested with simulated and experimental ultrasonic array data, each containing different noise levels. The simulated time domain signals allow the effects of array geometry, frequency, scatterer location, scatterer size, scatterer separation and random noise to be carefully controlled. The performance of the imaging algorithms is evaluated in terms of resolution and sensitivity to random noise. It is shown that for the low noise situation, time-reversal MUSIC provides enhanced lateral resolution when compared to the total focusing method. However, for higher noise levels, the total focusing method shows robustness, whilst the performance of time-reversal MUSIC is significantly degraded.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FIRST SCIENCE RESULTS FROM SOFIA/FORCAST: SUPER-RESOLUTION IMAGING OF THE S140 CLUSTER AT 37 {mu}m

We present 37 {mu}m imaging of the S140 complex of infrared sources centered on IRS1 made with the FORCAST camera on SOFIA. These observations are the longest wavelength imaging to resolve clearly the three main sources seen at shorter wavelengths, IRS 1, 2, and 3, and are nearly at the diffraction limit of the 2.5 m telescope. We also obtained a small number of images at 11 and 31 {mu}m that are useful for flux measurement. Our images cover the area of several strong submillimeter sources seen in the area-SMM 1, 2, and 3-that are not coincident with any mid-infrared sources and are not visible in our longer wavelength imaging either. Our new observations confirm previous estimates of the relative dust optical depth and source luminosity for the components in this likely cluster of early B stars. We also investigate the use of super-resolution to go beyond the basic diffraction limit in imaging on SOFIA and find that the van Cittert algorithm, together with the 'multi-resolution' technique, provides excellent results.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra‐Flexible Pixelated Perovskite Photodetectors Enabled by Honeycomb Polymer Grids for High‐Resolution Imaging

Abstract A nature‐inspired fabrication method based on a photolithography‐free flexible polymer grid is reported for high‐resolution pixelation of perovskite photodiode arrays with exceptional mechanical ductility and a morphology resembling that of natural compound eyes. The resulting pixelated perovskite photosensitive layer has a ≈1 µm pixel size with 2000 Pixels per inch (PPI) resolution when fully assembled as a photodetector array, delivering a detectivity of >10 13 Jones while providing cross‐talk free imaging. Using a polymer grid effectively releases stress on the perovskite platform, greatly increasing the mechanical agility of the otherwise brittle perovskite film. This novel fabrication methodology and device design offer new possibilities for applications in robotics, biomedical imaging, and virtual and augmented reality.

Zheng, Ding [Department of Chemistry and the Mater↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

HIGH-RESOLUTION IMAGING OF SOLAR FLARE RIBBONS AND ITS IMPLICATION ON THE THICK-TARGET BEAM MODEL

We report on high-resolution optical and hard X-ray observations of solar flare ribbons seen during the GOES X6.5 class white-light flare of 2006 December 6. The data consist of imaging observations at 430 nm (the Fraunhofer G band) taken by the Hinode Solar Optical Telescope with the hard X-rays observed by the Reuven Ramaty High Energy Solar Spectroscopic Imager. The two sets of data show closely similar ribbon structures, strongly suggesting that the flare emissions in white light and in hard X-rays have physically linked emission mechanisms. While the source structure along the ribbons is resolved at both wavelengths (length {approx} 30''), only the G-band observations resolve the width of the ribbon, with values between {approx}0.''5 and {approx}1.''8. The unresolved hard X-ray observations reveal an even narrower ribbon in hard X-rays (the main footpoint has a width perpendicular to the ribbon of <1.''1 compared to the G-band width of {approx}1.''8) suggesting that the hard X-ray emission comes from the sharp leading edge of the G-band ribbon. Applying the thick-target beam model, the derived energy deposition rate is >5 x 10{sup 12} erg s{sup -1} cm{sup -2} provided by an electron flux of 1 x 10{sup 20} electrons s{sup -1} cm{sup -2} above 18 keV. This requires that the beam density of electrons above 18 keV be at least 1 x 10{sup 10} cm{sup -3}. Even if field lines converge toward the chromospheric footpoints, the required beam in the corona has too high a density to be described as a dilute tail population on top of a Maxwellian core. We discuss this issue and others associated with this extreme event, which poses serious questions to the standard thick target beam interpretation of solar flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Sputter-Coated Metal Screening for Small Molecule Analysis and High-Spatial Resolution Imaging in Laser Desorption Ionization Mass Spectrometry

Nanoparticles are efficient matrices in laser desorption/ionization (LDI) mass spectrometry (MS), especially for the profiling or imaging of small molecules. Recently, solvent-free physical vapor desorption (PVD), or sputter coating, was adopted as a homogenous method to rapidly apply metal nanoparticles (NPs) in situ to samples prior to LDI MS or MS imaging analysis. However, there has been no systematic study comparing different metal targets for the analysis of a variety of small molecule metabolites. Here, we present a screening and optimization of various sputter-coated metals, including Ag, Au, Cu, Pt, Ni, and Ti, for LDI analysis of small molecules in both positive and negative ion modes. Optimized sputter coating is then applied to high-spatial resolution LDI mass spectrometry imaging (MSI) of maize root and seed cross-sections. Noble metals, Ag, Au, and Pt, are found to be much more efficient than transition metals and organic matrices for most small metabolites. Sputter-coated metals are efficient for neutral lipids, such as triacylglycerols and diacylglycerols, but are very inefficient for most phospholipids. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution images of diffuse neutral clouds in the milky way. I. Observations, imaging, and basic cloud properties

A set of diffuse interstellar clouds in the inner Galaxy within a few hundred parsecs of the Galactic plane has been observed at an angular resolution of ≈1 and farcm;0 combining data from the NRAO Green Bank Telescope and the Very Large Array. At the distance of the clouds, the linear resolution ranges from ∼1.9 to ∼2.8 pc. These clouds have been selected to be somewhat outside of the Galactic plane, and thus are not confused with unrelated emission, but in other respects they are a Galactic population. They are located near the tangent points in the inner Galaxy, and thus at a quantifiable distance: 2.3⩽R⩽6.0 kpc from the Galactic Center and −1000⩽z⩽+610 pc from the Galactic plane. These are the first images of the diffuse neutral H i clouds that may constitute a considerable fraction of the interstellar medium (ISM). Peak H i column densities lie in the range N{sub H i} = 0.8–2.9 × 10{sup 20} cm{sup −2}. Cloud diameters vary between about 10 and 100 pc, and their H i mass spans the range from less than a hundred to a few thousands M{sub ⊙}. The clouds show no morphological consistency of any kind, except that their shapes are highly irregular. One cloud may lie within the hot wind from the nucleus of the Galaxy, and some clouds show evidence of two distinct thermal phases as would be expected from equilibrium models of the ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry

Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. In our research, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We further describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution imaging of Hg/Se aggregates in the brain of small Indian mongoose, a wild terrestrial species: insights into intracellular Hg detoxification

Human activities result in the emission of 2000 metric tons of mercury compounds annually. Mercury (Hg) biomagnification has been characterized in marine mammals and predatory fish; however, little is known about mercury accumulation in brains of wild terrestrial species. Elevated Hg content, of 1.27 μg/g wet wt.—found in the brain of wild small Indian mongoose, prompted us to use synchrotron X-ray fluorescence imaging for simultaneous, quantitative mapping of biologically relevant and neurotoxic elements with high spatial resolution. X-ray fluorescence combined with immunohistochemistry revealed ~0.5–1.9 micron Hg-rich aggregates in cells of the choroid plexus and astrocytes of the subventricular wall in the mongoose brain. Hg content within aggregates correlated with selenium. Hg aggregates did not co-localize with lysosomes. The low Hg density inside aggregates indicated diffuse Hg binding to a Se-containing biomolecule, rather than much denser HgSe nanoparticles proposed to form in other species. Our data show the susceptibility of the small Indian mongoose population to Hg pollution and highlight the vulnerability of the brain as an organ targeted by mercury. Data also provide evidence on the adaptation in the form of a Se-based detoxification mechanism sequestering Hg into intracellular aggregates.

36 MATERIALS SCIENCE↗