Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Far Ultraviolet Imaging from the Image Spacecraft: System Design - 1

Direct imaging of the magnetosphere by the IMAGE spacecraft A,ill be supplemented by observation of the global aurora, the footprint of magnetospheric regions. To assure the simultaneity of these observations and tile measurement of the magnetospheric back-round neutral gas density, the IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. In tile wavelength region 120-1 90 nm. a downward-viewing aurora imager is only minimally contaminated sunlight, scattered from clouds and ground, and radiance of the aurora observed in a nadir viewing geometry can be observed in the presence of the high-latitude day-low. Tile Wideband Imaging Camera (WIC) will provide broadband ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a monochromatic imager, will image different types of aurora, filtered by wavelength. By measuring the Doppler-shifted Lyman-alpha, the proton-induced component of the aurora will be imaged separately. Finally, the GEO instrument will observe the distribution of the geocoronal emission, which is a measure of the neutral background density source of the charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing tile aurora and the Earth during, each spin. Detailed descriptions of the WIC, Si, GEO, and their individual performance validations are discussed in companion papers. This paper summarizes the system requirements and system design approach taken to satisfy the science requirements. One primary requirement is to maximize photon collection efficiency and use efficiently tile short time available foe exposures. The FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, multiple images are taken and electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distortion-corrected in real time foe both WIC and Si prior to co-adding. The distortion correction is accomplished using high-speed look Lip tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers as described in the companion papers. Extensive -round-based testing was performed with visible and near UV simulators mounted oil a rotating platform to estimate their on-orbit performance. The predicted instrument system performance is summarized and some of the preliminary data formats are shown.

Mende, S. B.↗

SU-E-J-237: Image Feature Based DRR and Portal Image Registration

Purpose: Two-dimensional (2D) matching of the kV X-ray and digitally reconstructed radiography (DRR) images is an important setup technique for image-guided radiotherapy (IGRT). In our clinics, mutual information based methods are used for this purpose on commercial linear accelerators, but with often needs for manual corrections. This work proved the feasibility that feature based image transform can be used to register kV and DRR images. Methods: The scale invariant feature transform (SIFT) method was implemented to detect the matching image details (or key points) between the kV and DRR images. These key points represent high image intensity gradients, and thus the scale invariant features. Due to the poor image contrast from our kV image, direct application of the SIFT method yielded many detection errors. To assist the finding of key points, the center coordinates of the kV and DRR images were read from the DICOM header, and the two groups of key points with similar relative positions to their corresponding centers were paired up. Using these points, a rigid transform (with scaling, horizontal and vertical shifts) was estimated. We also artificially introduced vertical and horizontal shifts to test the accuracy of our registration method on anterior-posterior (AP) and lateral pelvic images. Results: The results provided a satisfactory overlay of the transformed kV onto the DRR image. The introduced vs. detected shifts were fit into a linear regression. In the AP image experiments, linear regression analysis showed a slope of 1.15 and 0.98 with an R2 of 0.89 and 0.99 for the horizontal and vertical shifts, respectively. The results are 1.2 and 1.3 with R2 of 0.72 and 0.82 for the lateral image shifts. Conclusion: This work provided an alternative technique for kV to DRR alignment. Further improvements in the estimation accuracy and image contrast tolerance are underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method to determine fault vectors in 4H-SiC from stacking sequences observed on high resolution transmission electron microscopy images

A new method has been developed to determine the fault vectors associated with stacking faults in 4H-SiC from their stacking sequences observed on high resolution TEM images. This method, analogous to the Burgers circuit technique for determination of dislocation Burgers vector, involves determination of the vectors required in the projection of the perfect lattice to correct the deviated path constructed in the faulted material. Results for several different stacking faults were compared with fault vectors determined from X-ray topographic contrast analysis and were found to be consistent. This technique is expected to applicable to all structures comprising corner shared tetrahedra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging local electric fields produced upon synchrotron X-ray exposure

Electron-hole separation following hard X-ray absorption during diffraction analysis of soft materials under cryogenic conditions produces substantial local electric fields visualizable by second harmonic generation (SHG) microscopy. Monte Carlo simulations of X-ray photoelectron trajectories suggest the formation of substantial local electric fields in the regions adjacent to those exposed to X-rays, indicating a possible electric-field-induced SHG (EFISH) mechanism for generating the observed signal. In studies of amorphous vitreous solvents, analysis of the SHG spatial profiles following X-ray microbeam exposure was consistent with an EFISH mechanism. Within protein crystals, exposure to 12-keV (1.033-angstrom) X-rays resulted in increased SHG in the region extending similar to 3 mu m beyond the borders of the X-ray beam. Moderate X-ray exposures typical of those used for crystal centering by raster scanning through an X-ray beam were sufficient to produce static electric fields easily detectable by SHG. The X-ray-induced SHG activity was observed with no measurable loss for longer than 2 wk while maintained under cryogenic conditions, but disappeared if annealed to room temperature for a few seconds. These results provide direct experimental observables capable of validating simulations of X-ray-induced damage within soft materials. In addition, X-ray-induced local fields may potentially impact diffraction resolution through localized piezoelectric distortions of the lattice.

Dettmar, Christopher M.↗

Compressed Streak Imaging Beam Diagnostic

We are planning a new beam diagnostic based on Compressed Ultrafast Photography (CUP)1.A foil inserted in the beam path is used to generate a continuous optical image of the beam, which is the same technique used on the existing DARHT II beam imaging diagnostic. This existing diagnostic compresses the beam image with anamorphic lenses into four views that are streaked simultaneously on two streak cameras. In our new beam diagnostic design the anamorphic lenses are replaced with regular lenses and the beam image is stamped with a pseudo-random mask pattern. The full image is imaged onto a streak camera with its entrance slit expanded. Modifying the CUP technique, which uses a single streaked image, our design splits the image into four rotated copies and puts all four images on two streak cameras. A data cube of multiple image frames is reconstructed from the streak camera data through the use of the TwiST algorithm2 combined with total variation denoising3. The additional rotated images improve spatial resolution and reduce noise and image artifacts compared to using a single streaked image. In reconstructions of simulated data, fine detail in the beam profile can be seen and there is a remarkable absence of image artifacts compared to the existing DARHT II beam imaging diagnostic. Performance was evaluated using a pseudo-MTF derived from a simulated wave pattern test object.

Marks, Daniel G.↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Evaluation of the Use of Direct Electron Density CT Images in Radiation Therapy

Purpose: The current standard for calculation of photon and electron dose requires conversion of Hounsfield Units (HU) to Electron Density (ED) by applying a calibration curve specifically constructed for the corresponding CT tube voltage. This practice limits the use of the CT scanner to a single tube voltage and hinders the freedom in the selection of optimal tube voltage for better image quality. The objective of this study is to report a prototype CT reconstruction algorithm that provides direct ED images from the raw CT data independently of tube voltages used during acquisition. Methods: A tissue substitute phantom was scanned for Stoichiometric CT calibrations at tube voltages of 70kV, 80kV, 100kV, 120kV and 140kV respectively. HU images and direct ED images were acquired sequentially on a thoracic anthropomorphic phantom at the same tube voltages. Electron densities converted from the HU images were compared to ED obtained from the direct ED images. A 7-field treatment plan was made on all HU and ED images. Gamma analysis was performed to demonstrate quantitatively dosimetric change from the two schemes in acquiring ED. Results: The average deviation of EDs obtained from the direct ED images was −1.5%±2.1% from the EDs from HU images with the corresponding CT calibration curves applied. Gamma analysis on dose calculated on the direct ED images and the HU images acquired at the same tube voltage indicated negligible difference with lowest passing rate at 99.9%. Conclusion: Direct ED images require no CT calibration while demonstrate equivalent dosimetry compared to that obtained from standard HU images. The ability of acquiring direct ED images simplifies the current practice at a safer level by eliminating CT calibration and HU conversion from commissioning and treatment planning respectively. Furthermore, it unlocks a wider range of tube voltages in CT scanner for better imaging quality while maintaining similar dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Simultaneous neutron and x-ray imaging of inertial confinement fusion experiments along a single line of sight at Omega

Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. Thus, the technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

How to COAAD Images. II. A Coaddition Image that is Optimal for Any Purpose in the Background-dominated Noise Limit

Image coaddition is one of the most basic operations that astronomers perform. In Paper I, we presented the optimal ways to coadd images in order to detect faint sources and to perform flux measurements under the assumption that the noise is approximately Gaussian. Here, we build on these results and derive from first principles a coaddition technique that is optimal for any hypothesis testing and measurement (e.g., source detection, flux or shape measurements, and star/galaxy separation), in the background-noise-dominated case. This method has several important properties. The pixels of the resulting coadded image are uncorrelated. This image preserves all the information (from the original individual images) on all spatial frequencies. Any hypothesis testing or measurement that can be done on all the individual images simultaneously, can be done on the coadded image without any loss of information. The PSF of this image is typically as narrow, or narrower than the PSF of the best image in the ensemble. Moreover, this image is practically indistinguishable from a regular single image, meaning that any code that measures any property on a regular astronomical image can be applied to it unchanged. In particular, the optimal source detection statistic derived in Paper I is reproduced by matched filtering this image with its own PSF. This coaddition process, which we call proper coaddition, can be understood as the maximum signal-to-noise ratio measurement of the Fourier transform of the image, weighted in such a way that the noise in the entire Fourier domain is of equal variance. This method has important implications for multi-epoch seeing-limited deep surveys, weak lensing galaxy shape measurements, and diffraction-limited imaging via speckle observations. The last topic will be covered in depth in future papers. We provide an implementation of this algorithm in MATLAB.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian image reconstruction - The pixon and optimal image modeling

In this paper we describe the optimal image model, maximum residual likelihood method (OptMRL) for image reconstruction. OptMRL is a Bayesian image reconstruction technique for removing point-spread function blurring. OptMRL uses both a goodness-of-fit criterion (GOF) and an 'image prior', i.e., a function which quantifies the a priori probability of the image. Unlike standard maximum entropy methods, which typically reconstruct the image on the data pixel grid, OptMRL varies the image model in order to find the optimal functional basis with which to represent the image. We show how an optimal basis for image representation can be selected and in doing so, develop the concept of the 'pixon' which is a generalized image cell from which this basis is constructed. By allowing both the image and the image representation to be variable, the OptMRL method greatly increases the volume of solution space over which the image is optimized. Hence the likelihood of the final reconstructed image is greatly increased. For the goodness-of-fit criterion, OptMRL uses the maximum residual likelihood probability distribution introduced previously by Pina and Puetter (1992). This GOF probability distribution, which is based on the spatial autocorrelation of the residuals, has the advantage that it ensures spatially uncorrelated image reconstruction residuals.

Pina, R. K.↗

Digital camera with apparatus for authentication of images produced from an image file

A digital camera equipped with a processor for authentication of images produced from an image file taken by the digital camera is provided. The digital camera processor has embedded therein a private key unique to it, and the camera housing has a public key that is so uniquely based upon the private key that digital data encrypted with the private key by the processor may be decrypted using the public key. The digital camera processor comprises means for calculating a hash of the image file using a predetermined algorithm, and second means for encrypting the image hash with the private key, thereby producing a digital signature. The image file and the digital signature are stored in suitable recording means so they will be available together. Apparatus for authenticating at any time the image file as being free of any alteration uses the public key for decrypting the digital signature, thereby deriving a secure image hash identical to the image hash produced by the digital camera and used to produce the digital signature. The apparatus calculates from the image file an image hash using the same algorithm as before. By comparing this last image hash with the secure image hash, authenticity of the image file is determined if they match, since even one bit change in the image hash will cause the image hash to be totally different from the secure hash.

Friedman, Gary L.↗

Far Ultraviolet Imaging from the Image Spacecraft

Direct imaging of the magnetosphere by the IMAGE spacecraft will be supplemented by observation of the global aurora. The IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. The Wideband Imaging Camera (WIC) will provide broad band ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a novel form of monochromatic imager, will image the aurora, filtered by wavelength. The proton-induced component of the aurora will be imaged separately by measuring the Doppler-shifted Lyman-a. Finally, the GEO instrument will observe the distribution of the geocoronal emission to obtain the neutral background density source for charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing the aurora and the Earth during each spin. To maximize photon collection efficiency and use efficiently the short time available for exposures the FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, the set of multiple images are electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distort ion-corrected in real time. The distortion correction is accomplished using high speed look up tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers. Extensive ground-based testing was performed with visible and near UV simulators mounted on a rotating platform to emulate their performance on a rotating spacecraft.

Mende, S. B.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arc minute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arcminute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗