Effects of test facility contaminants on supersonic hydrogen-air diffusion flames
Results are presented from an analytical assessment of the effects of NO and H2O in air on the ignition and reaction of hydrogen. Three flow models of the burning process were used, each including a 32 reaction chemistry mechanism. These models were a plug flow reactor to determine ignition and reaction times; a well-stirred reactor to assess flame stability or blow-off; and a parabolic Navier-Stokes code to examine the diffusion flame combustion. The diffusion flame was computed for a cold supersonic H2 jet coaxial with a supersonic air stream at a static temperature of 1100 K and a pressure of 1 atmosphere.