Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurements of stable isotope ratios in milk samples from a farm placed in the mountains of Transylvania

Product origin is of great importance for consumers especially because its association in consumer's perception with food quality, freedom from disease or pollution. Stable isotope ratio analysis is a powerful technique in food authenticity and traceability control which has been introduced within the European wine industry to ensure authenticity of wine provenance and to detect adulteration. Isotopic ratios measurements have also been successfully to other food commodities like: fruit juices, honey and dairy foods. The δ{sup 18}O and δ{sup 2}H content in milk water reflects the isotope composition of the ground water drunk by animals. Seasonal effects are also very important: in summer, milk water contains higher δ{sup 18}O and δ{sup 2}H values due to the fresh plants that are ate by animals. Relative carbon stable isotope abundances in total milk reflect the isotopic composition of the diet fed to the dairy cows. In this study the hydrogen, oxygen and carbon isotopic composition of 15 milk samples coming from a unit placed in the mountains of Transylvania was investigated. The distribution of the obtained isotopic values was than discussed taking into account that all the animals were feed with the same type of forage and consumed water was taken from the same source.

54 ENVIRONMENTAL SCIENCES↗

Improved sample utilization in thermal ionization mass spectrometry isotope ratio measurements: refined development of porous ion emitters for nuclear forensic applications

The precise and accurate determination of isotopic composition in nuclear forensic samples is vital for assessing origin, intended use and process history. Thermal ionization mass spectrometry (TIMS) is widely accepted as the gold standard for high performance isotopic measurements and has long served as the workhorse in the isotopic ratio determination of nuclear materials. Nuclear forensic and safeguard specialists have relied heavily on such methods for both routine and atypical e orts. Despite widespread use, TIMS methods for the assay of actinide systems continue to be hindered by poor ionization e ciency, often less than tenths of a percent; the majority of a sample is not measured. This represents a growing challenge in addressing nextgeneration nuclear detection needs by limiting the ability to analyze ultratrace quantities of high priority elements that could potentially provide critical nuclear forensic signatures. Porous ion emitter (PIE) thermal ion sources were developed in response to the growing need for new TIMS ion source strategies for improved ionization e ciency, PIEs have proven to be simple to implement, straightforward approach to boosting ion yield. This work serves to expand the use of PIE techniques for the analysis of trace quantities of plutonium and americium. PIEs exhibited superior plutonium and americium ion yields when compared to direct lament loading and the resin bead technique, one of the most e cient methods for actinide analysis, at similar mass loading levels. Initial attempts at altering PIE composition for the analysis of plutonium proved to enhance sample utilization even further. Preliminary investigations of the instrumental fractionation behavior of plutonium and uranium analyzed via PIE methods were conducted. Data collected during these initial trial indicate that PIEs fractionate in a consistent, reproducible manner; a necessity for high precision isotope ratio measurements. Ultimately, PIEs methods were applied for the age determination of various uranium isotopic standards. PIEs did not exhibit signi cant advantages for the determination of model ages when compared to traditional laments; however, this trial was able to provide valuable insight for guiding future investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Micropyrolyzer for Enhanced Isotope Ratio Measurement

This paper presents design, fabrication and testing of a micro scale reactor for the pyrolysis of organic compounds. The reactor system described here is suitable for use in enhanced isotope ratio measurement in a continuous flow mode. A characteristic of such a system is it can be utilized to pyrolyze organic compounds with sample size 20-50 times smaller than conventional. Results have shown that organic compounds, such as 1-butanol, ethanol, and ethanol amine, can be fully decomposed to desired products CO and H2, at temperature of 1200oC, which is 200oC lower than conventionally reported. Undesired products methane and CO2 are eliminated in the pyrolysis process. The proof-of-concept experimental results clearly demonstrate that the micro pyrolyzer can be readily integrated with isotope ratio mass spectrometer (IRMS) to differentiate between different sources of the same materials.

03 NATURAL GAS↗

Content and Isotope Ratios of Noble Gases in Congelation Ice of Lake Vostok

Isotope ratios of noble gases (He, Ne, Ar) were studied in samples collected by degassing of cores of water frozen over a glacier of Lake Vostok. The gases were collected into glass retorts during three days of degassing of cores, which have just been extracted from the borehole. Within the error, the isotope {sup 3}He/{sup 4}He ratios of 0.28 ± 0.08 R{sub A} (R{sub A} = 1.38 × 10{sup –6} is the ratio for air) correspond to those from [1]. The {sup 4}He/{sup 20}Ne and {sup 40}Ar/{sup 36}Ar ratios (12.4 ± 4.6 R{sub A} and 1.0074 ± 0.0023 R{sub A}, respectively) exceed their contents in air ({sup 4}He/{sup 20}Ne{sub A} = 0.29; {sup 40}Ar/{sup 36}Ar{sub A} = 298.6) and may indicate some contribution of terrigenous gas to the gaseous balance of the lake, as well as the high content of ancient ground waters in the lake. The {sup 3}He/{sup 4}He ratio of 0.28 R{sub A} means low mantle {sup 3}He flux typical of continental platforms far from active rift zones.

54 ENVIRONMENTAL SCIENCES↗

Along-strike magma mixing beneath mid-ocean ridges - Effects on isotopic ratios

The effects of mixing processes on the isotopic variability of midocean ridge basalts are studied. The processes considered are porous flow dispersion and convective mixing in magma chambers. Porous flow dispersion is capable of mixing magmas over distances of only a few tens of meters. Convective mixing, on the other hand, is found to produce continuous magma chambers, where mixing is limited by convective processes, and for discontinuous chambers, where mixing is limited by chamber size. Preliminary comparison of the calculations with observations along the midocean ridges shows that the calculations are consistent with the existence of a correlation between bathymetry and isotopic ratio at long, but not at short, wavelengths. They are also capable of explaining a decrease in isotopic variability with increasing spreading rate.

Kenyon, P. M.↗

Evaluation of micromilling/conventional isotope ratio mass spectrometry and secondary ion mass spectrometry of δ 18 O values in fish otoliths for sclerochronology

Stable oxygen isotope ratios (δ 18 O values) measured in fish otoliths can provide valuable detailed information on fish life history, fish age determination, and ocean thermography. Traditionally, otoliths are sampled by micromilling followed by isotope ratio mass spectrometry (IRMS), but direct analysis by secondary ion mass spectrometry (SIMS) is becoming more common. However, these two methods have not been compared to determine which, if either, is better for fish age validation studies. Hence, the goals were to: (1) determine if the δ 18 O signatures from the two different methods are similar, (2) determine which method is better for fish age validation studies, and (3) examine biogeographic and migration history. Both analytical techniques, micromilling/IRMS and SIMS, were used to measure δ 18 O values in six Pacific cod (Gadus macrocephalus) otoliths. A series of measurements was made from the center of each otolith to its edge to develop a life-history δ 18 O signature for each fish. The sampling resolution of SIMS analyses was 2–3 times greater than that obtained by micromilling/IRMS. We found an offset between SIMS and micromilling/IRMS δ 18 O values, about 0.5‰ on average, with SIMS yielding lower values. However, the δ 18 O patterns from both methods (i.e., the number of δ 18 O maxima) correspond to the estimated age determined by otolith growth-zone counts, validating fish age determination methods. Both techniques resolved δ 18 O life-history signatures and showed patterns consistent with seasonal variation in temperatures and changes due to fish migration. When otoliths are large, micromilling/IRMS can provide adequate resolution for fish age validation. Finally, SIMS is the better option if greater sampling resolution is required, such as when otoliths are small or specimens are longer lived and have compact growth zones.

54 ENVIRONMENTAL SCIENCES↗

Rapid measurements of 235 U fission product isotope ratios using an online, high-pressure ion chromatography inductively coupled plasma mass spectrometry protocol with comparison to isotopic depletion models

An automated online separation–direct analysis method, RAPID (rapid analysis of post-irradiation debris), has been developed for the measurement of the concentration and isotopic composition of over 40 elements down to the low-picogram level. Here we discuss the application of RAPID to irradiated highly-enriched uranium, demonstrating that it has the sensitivity required to achieve precise, low-level analyses of non-natural isotopes, even in the presence of a bulk uranium matrix. As a result, isotopic ratios have been successfully measured at the low-picogram level, and the accuracy of these ratios was confirmed using an isotopic depletion and decay modeling software to within 1–2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Unified Interpretation of Variability in Precipitation Isotope Ratios

Abstract Several mechanisms have been proposed to explain why the isotope ratios of precipitation vary in space and time and why they correlate with other climate variables like temperature and precipitation. Here, we argue that this behavior is best understood through the lens of radiative transfer, which treats the depletion of atmospheric vapor transport by precipitation as analogous to the attenuation of light by absorption or scattering. Building on earlier work by Siler et al., we introduce a simple model that uses the equations of radiative transfer to approximate the two-dimensional pattern of the oxygen isotope composition of precipitation ( δ p ) from monthly mean hydrologic variables. The model accurately simulates the spatial and seasonal variability in δ p within a state-of-the-art climate model and permits a simple decomposition of δ p variability into contributions from gradients in evaporation and the length scale of vapor transport. Outside the tropics, δ p is mostly controlled by gradients in evaporation, whose dependence on temperature explains the positive correlation between δ p and temperature (i.e., the temperature effect). At low latitudes, δ p is mostly controlled by gradients in the transport length scale, whose inverse relationship with precipitation explains the negative correlation between δ p and precipitation (i.e., the amount effect). This suggests that the temperature and amount effects are both mostly explained by the variability in upstream rainout, but they reflect distinct mechanisms governing rainout at different latitudes. Significance Statement The isotopic composition of precipitation has long been used to make inferences about past climates based on its observed relationship with precipitation in the tropics and with temperature at higher latitudes. These relationships—known as the “amount effect” and “temperature effect,” respectively—have been attributed to many different mechanisms, most of which are thought to operate at either high or low latitudes but not both. Here, we present a unified framework for interpreting the isotope variability that can explain the latitude dependence of the temperature and amount effects despite making no distinction between high and low latitudes. Although our results are generally consistent with certain interpretations of the amount effect, they suggest that the temperature effect is widely misunderstood.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Non-traditional Isotopic Ratios by Mass Spectrometry for Analysis of Nuclear Activities: Annual Report Year 2

The objective of this work is to identify isotopic ratios suitable for analysis via mass spectrometry that distinguish between commercial nuclear reactor fuel cycles, fuel cycles for weapons grade plutonium, and products from nuclear weapons explosions. Methods will also be determined to distinguish the above from medical and industrial radionuclide sources. Mass spectrometry systems will be identified that are suitable for field measurement of such isotopes in an expedient manner. Significant progress has been made with this project within the past year: (1) Isotope production from commercial nuclear fuel cycles and nuclear weapons fuel cycles have been modeled with the ORIGEN and MCNPX codes. (2) MCNPX has been utilized to calculate isotopic inventories produced in a short burst fast bare sphere reactor (to approximate the signature of a nuclear weapon). (3) Isotopic ratios have been identified that are good for distinguishing between commercial and military fuel cycles as well as between nuclear weapons and commercial nuclear fuel cycles. (4) Mass spectrometry systems have been assessed for analysis of the fission products of interest. (5) A short-list of forensic ratios have been identified that are well suited for use in portable mass spectrometry systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chlorine Isotope Effects from Isotope Ratio Mass Spectrometry Suggest Intramolecular C-Cl Bond Competition in Trichloroethene (TCE) Reductive Dehalogenation

Chlorinated ethenes are prevalent groundwater contaminants. To better constrain (bio)chemical reaction mechanisms of reductive dechlorination, the position-specificity of reductive trichloroethene (TCE) dehalogenation was investigated. Selective biotransformation reactions (i) of tetrachloroethene (PCE) to TCE in cultures of Desulfitobacterium sp. strain Viet1; and (ii) of TCE to cis-1,2-dichloroethene (cis-DCE) in cultures of Geobacter lovleyi strain SZ were investigated. Compound-average carbon isotope effects were -19.0‰ ± 0.9‰ (PCE) and -12.2‰ ± 1.0‰ (TCE) (95% confidence intervals). Using instrumental advances in chlorine isotope analysis by continuous flow isotope ratio mass spectrometry, compound-average chorine isotope effects were measured for PCE (-5.0‰ ± 0.1‰) and TCE (-3.6‰ ± 0.2‰). In addition, position-specific kinetic chlorine isotope effects were determined from fits of reactant and product isotope ratios. In PCE biodegradation, primary chlorine isotope effects were substantially larger (by -16.3‰ ± 1.4‰ (standard error)) than secondary. In TCE biodegradation, in contrast, the product cis-DCE reflected an average isotope effect of -2.4‰ ± 0.3‰ and the product chloride an isotope effect of -6.5‰ ± 2.5‰, in the original positions of TCE from which the products were formed (95% confidence intervals). A greater difference would be expected for a position-specific reaction (chloride would exclusively reflect a primary isotope effect). These results therefore suggest that both vicinal chlorine substituents of TCE were reactive (intramolecular competition). This finding puts new constraints on mechanistic scenarios and favours either nucleophilic addition by Co(I) or single electron transfer as reductive dehalogenation mechanisms.

organohalide respiration↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

THE RISE OF THE AGB IN THE GALACTIC HALO: Mg ISOTOPIC RATIOS AND HIGH PRECISION ELEMENTAL ABUNDANCES IN M71 GIANTS

High-resolution (R{approx} 100,000), high signal-to-noise spectra of M71 giants have been obtained with High Resolution Echelle Spectrometer at the Keck I telescope in order to measure their Mg isotopic ratios, as well as elemental abundances of C, N, O, Na, Mg, Al, Si, Ca, Ti, Ni, Zr, and La. We demonstrate that M71 has two populations, the first having weak CN, normal O, Na, Mg, and Al, and a low ratio of {sup 26}Mg/Mg ({approx}4%) consistent with models of galactic chemical evolution with no contribution from asymptotic giant branch (AGB) stars. The Galactic halo could have been formed from the dissolution of globular clusters prior to their intermediate-mass stars reaching the AGB. The second population has enhanced Na and Al accompanied by lower O and by higher {sup 26}Mg/Mg ({approx}8%), consistent with models which do incorporate ejecta from AGB stars via normal stellar winds. All the M71 giants have identical [Fe/H], [Si/Fe], [Ca/Fe], [Ti/Fe], and [Ni/Fe] to within {sigma} = 0.04 dex (10%). We therefore infer that the timescale for formation of the first generation of stars we see today in this globular cluster must be sufficiently short to avoid a contribution from AGB stars, i.e., less than {approx}0.3 Gyr. Furthermore, the Mg isotopic ratios in the second M71 population, combined with their elemental abundances for the light elements, demonstrate that the difference must be the result of adding in the ejecta of intermediate-mass AGB stars. Finally, we suggest that the low amplitude of the abundance variations of the light elements within M71 is due to a combination of its low mass and its relatively high Fe-metallicity.

99 GENERAL AND MISCELLANEOUS↗

Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

Freeman, K. H.↗

Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry

The performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.

NASA Discipline Exobiology↗

Carbon isotopic ratios in some low-delta N-15 lunar breccias

Lunar soil breccias 10018, 79035 and 79135 were analyzed for carbon and nitrogen contents and isotopic compositions by vacuum pyrolysis, with a 500 C pre-combustion step in some cases. The combustion was used to remove carbon of terrestrial origin. Nitrogen isotopic ratios for the breccias are very low and are in agreement with results in the literature. Nitrogen yields in two cases were lower than literature values, a result attributable to heterogeneous mixing of implanted and implantation-free components in the breccias. Carbon isotopic ratios were found to be low in these breccias, even when reasonable account is taken of terrestrial carbon contamination. The results are consistent with the idea that low-delta N-15 values in lunar soils and breccias are accompanied by low-delta C-13 values, and imply that any secular variation which occurred in the delta N-15 of nitrogen implanted in lunar soils was accompanied by a similar but smaller variation in the delta C-13 of implanted carbon.

Becker, R. H.↗

Atmospheric Trace Gas Abundances and Stable Isotope Ratios via IR-LIF

We propose to develop new technologies with support provided by PIDDP that will enable the in situ measurements of abundances and stable isotope ratios in important radiatively and biogenically active gases such as carbon dioxide, carbon monoxide, water, methane, nitrous oxide, and hydrogen sulfide to very high precision (0.1 per mil or better for the isotopic ratios, for example). Such measurements, impossible at present, could provide pivotal new constraints on the global (bio)geochemical budgets of these critical species, and could also be used to examine the dynamics of atmospheric transport on Mars, Titan, and other solar system bodies. We believe the combination of solid state light sources with imaging of the IR laser induced fluorescence (IR-LIF) via newly available detector arrays will make such in situ measurements possible for the first time. Even under ambient terrestrial conditions, the LIF yield from vibrational excitation of species such as water and carbon dioxide should produce emission measures well in excess of ten billion photons/sec from samples volumes of order 1 c.c. These count rates can, in principle, yield detection limits into the sub-ppt range that are required for the in situ isotopic study of atmospheric trace gases. While promising, such technologies are relatively immature, but developing rapidly, and there are a great many uncertainties regarding their applicability to in situ IR-LIF planetary studies. We therefore feel PIDDP support will be critical to developing these new tools, and propose a three-year program to combine microchip near-IR lasers with low background detection axes and state-of-the-art HgCdTe detectors developed for astronomical spectroscopy to investigate the sensitivity of IR-LIF under realistic planetary conditions, to optimize the optical pumping and filtering schemes for important species, and to apply the spectrometer to the non-destructive measurement of stable isotopes in a variety of test samples. These studies form the necessary precursors to the development of compact, lightweight stable isotope/trace gas sensors for future planetary missions.

Blake, Geoffrey A.↗