Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Isotope Production at the Jefferson Lab LERF Facility

The project initially proceeded well, meeting all of the Milestones. However, the need to create a new irradiation area in the LERF (the initial proposal was to use the CEBAF Injector) used up a larger fraction of the budget than foreseen. A further problem arose when the hot-cell became unavailable at VCU, followed by VCU dropping out of the collaboration. This meant that we were unable to separate the 67 Cu from the gallium. We replaced this by carrying out detailed gamma spectroscopy to determine the quantity of 67 Cu produced. This work was published as presentations in November of 2021 by the two doctoral students (Geno Santistevan and Robert Bentley) and proceedings articles for American Nuclear Society’s topical meeting AccApp21 (https://www.ans.org/pubs/proceedings/issue-3206/), as well as in invited, expanded versions in the peer-reviewed journal “Nuclear Science and Engineering”. Geno and Robert have subsequently successfully leveraged this research to achieve “doctoral candidacy” status and are expected to defend their dissertations in the Fall of 2023.

07 ISOTOPE AND RADIATION SOURCES↗

Rapid measurements of 235 U fission product isotope ratios using an online, high-pressure ion chromatography inductively coupled plasma mass spectrometry protocol with comparison to isotopic depletion models

An automated online separation–direct analysis method, RAPID (rapid analysis of post-irradiation debris), has been developed for the measurement of the concentration and isotopic composition of over 40 elements down to the low-picogram level. Here we discuss the application of RAPID to irradiated highly-enriched uranium, demonstrating that it has the sensitivity required to achieve precise, low-level analyses of non-natural isotopes, even in the presence of a bulk uranium matrix. As a result, isotopic ratios have been successfully measured at the low-picogram level, and the accuracy of these ratios was confirmed using an isotopic depletion and decay modeling software to within 1–2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inorganic resins enable the increased purification efficiency of 82 Sr from rubidium targets for use in PET imaging isotope production

The 82 Sr/ 82 Rb generator system has found use in positron emission tomography (PET) imaging of myocardial perfusion. 82 Sr is produced by proton irradiation of Rb metal/RbCl salt followed by chemical separation. Inorganic ion-exchangers were synthesized by hydrothermal methods and evaluated for the purification of accelerator-produced 82Sr from a RbCl target and co-produced impurities like 75 Se, Fe, Cr, and Ni. A process consisting of removal of bulk RbCl using sodium nonatitanate (SNT), then removal of remaining tracers of Rb and Se using poorly crystalline silicotitanate (pCST) is suitable for 82 Sr separation and achieves higher purity of 82 Sr vs. commonly used organic resins.

43 PARTICLE ACCELERATORS↗

WOSMIP II- Workshop on Signatures of Medical and Industrial Isotope Production

Medical and industrial radioisotopes are fundamental tools used in science, medicine and industry with an ever expanding usage in medical practice where their availability is vital. Very sensitive environmental radionuclide monitoring networks have been developed for nuclear-security-related monitoring [particularly Comprehensive Test-Ban-Treaty (CTBT) compliance verification] and are now operational.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mo-99 Stripping Results and Column Designs for Mini-Medical Isotope Production System (MIPS)

Results from the column tests performed by using small volumes of irradiated solutions as tracers for depleted uranium (DU) solutions containing stable molybdenum (Mo) as Na 2 MoO 4 forced us to investigate the stripping parameters needed to obtain full Mo recovery. In an effort to optimize the stripping conditions, several column runs were done by using either 1 M NaOH or NH 4 OH as the stripping agent at different velocities. Overall, we obtained very inconsistent results that suggest stripping velocity does not affect Mo recovery as much as originally believed. In addition, we generated 0.1 M HNO 3 breakthrough curves after each run to determine if the performance of the column was changing. Future experiments will utilize columns packed with fresh sorbent after each run. The column designs for the mini-MIPS 5-liter (L) and 20-L experiments employed data obtained from using several different S80 columns at different loading, washing, and stripping velocities. Data were input into the VERSE code, and plant-scale column designs were generated. The mini-MIPS column designs and parameters are a direct downscale of the plant operation, where full Mo adsorption and recovery are expected.

Youker, Amanda J.↗

Long Baseline Neutrino Experiment (LBNE) Target Material Radiation Damage from Energetic Protons of the Brookhaven Linear Isotope Production (BLIP) Facility

In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) various grades of graphite were irradiated with 140-180 MeV protons to fluence up to ~6 10 20 cm -2 and irradiation temperatures in the range of 100-200oC. The objective of the irradiation experiment was to assess the radiation induced changes in the graphite onset by its interaction with energetic protons and deduce some measure of performance and survivability under the design conditions of LBNF. A multi-faceted post-irradiation evaluation was conducted to both qualify and quantify the induced material property changes. These studies included dimensional stability and thermal expansion, damage annealing via thermal cycling, high temperature post-irradiation annealing to mimic irradiation at elevated temperatures, stress-strain behavior, oxidation contribution to the postirradiation analysis, potential influence of the argon atmosphere under which irradiation took place, and lattice evolution. Dilatometry-based techniques were coupled with ultrasound-based annealing methodologies as well as DSC and TGA analyses. X-ray diffraction experiments assessed the lattice parameter changes and SEM analyses were used to study the different graphite grade structures. The multi-faceted post-irradiation evaluation, in conjunction with off-beam analyses, revealed some important facts regarding the choice of a graphite grade. Specifically, it was observed that the microstructure of a grade plays an important role in its dimensional stability. X-ray diffraction data indicated variability in basal plane spacing prior to irradiation with POCO d 002 =3.3833 Å, IG-430 d 002 =3.36814 Å and R7650 d 002 =3.37944 Å. Isotropic graphite grades such as POCO and IG-430 are confirmed to undergo microstructural shrinking under irradiation. All four irradiated graphite grades experience irradiation-induced creep leading to increased Young’s modulus with changes as high as 50% that varies with microstructure. X-ray diffraction on irradiated graphite confirmed previously made observations where under both energetic protons as well as fast neutrons of fluence > 5 10 20 cm -2 and at temperatures around 200°C acceleration of the effects on both the micro-and macrostructure is observed. Amongst the irradiated grades POCO graphite showed tendency to increase crystallinity order but also shows turbostratic state resulting from the interaction of its lattice with protons. This report presents and discusses the details of the irradiation experiment and the results of the postirradiation evaluation with main objective the assessment of the applicability and survivability of the selected four graphite grades as high-power accelerators pion production targets where the structural integrity, density reduction, dimensional and physical property stability are of paramount importance.

43 PARTICLE ACCELERATORS↗