Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Diffusion on Cu surfaces

Understanding surface diffusion is essential in understanding surface phenomena, such as crystal growth, thin film growth, corrosion, physisorption, and chemisorption. Because of its importance, various experimental and theoretical efforts have been directed to understand this phenomena. The Field Ion Microscope (FIM) has been the major experimental tool for studying surface diffusion. FIM have been employed by various research groups to study surface diffusion of adatoms. Because of limitations of the FIM, such studies are only limited to a few surfaces: nickel, platinum, aluminum, iridium, tungsten, and rhodium. From the theoretical standpoint, various atomistic simulations are performed to study surface diffusion. In most of these calculations the Embedded Atom Method (EAM) along with the molecular static (MS) simulation are utilized. The EAM is a semi-empirical approach for modeling the interatomic interactions. The MS simulation is a technique for minimizing the total energy of a system of particles with respect to the positions of its particles. One of the objectives of this work is to develop the EAM functions for Cu and use them in conjunction with the molecular static (MS) simulation to study diffusion of a Cu atom on a perfect as well as stepped Cu(100) surfaces. This will provide a test of the validity of the EAM functions on Cu(100) surface and near the stepped environments. In particular, we construct a terrace-ledge-kink (TLK) model and calculate the migration energies of an atom on a terrace, near a ledge site, near a kink site, and going over a descending step. We have also calculated formation energies of an atom on the bare surface, a vacancy in the surface, a stepped surface, and a stepped-kink surface. Our results are compared with the available experimental and theoretical results.

Karimi, Majid↗

Influence of the tensor force on the microscopic heavy-ion interaction potential

The tensor interaction is known to play an important role in the nuclear structure studies of exotic nuclei. However, most microscopic studies of low-energy nuclear reactions neglect the tensor force, resulting in a lack of knowledge concerning the effect of the tensor force on heavy-ion collisions. An accurate description of the heavy-ion interaction potential is crucial for understanding the microscopic mechanisms of heavy-ion fusion dynamics. Furthermore, the building blocks of the heavy-ion interaction potential in terms of the ingredients of the effective nucleon-nucleon interaction provides the physical underpinnings for connecting the theoretical results with experiment. The tensor force has never been incorporated for calculating the nucleus-nucleus interaction potential. The theoretical study of the influence of the tensor force on heavy-ion interaction potentials is required to further our understanding of the microscopic mechanisms entailed in fusion dynamics. The full Skyrme tensor force is implemented into the static Hartree-Fock and dynamic density-constrained time-dependent Hartree-Fock (DC-TDHF) theory to calculate both static (frozen density) and dynamic microscopic interaction potentials for reactions involving exotic and stable nuclei. The static potentials are found to be systematically higher than the dynamical results, which are attributed to the microscopic dynamical effects included in TDHF. We also show that the dynamical potential barriers vary more significantly by the inclusion of tensor force than the static barriers. The influence of isoscalar and isovector tensor terms is also investigated with the TIJ set of forces. For light systems, the tensor force is found to have an imperceptible effect on the nucleus-nucleus potential. However, for medium and heavy spin-unsaturated reactions, the potentials may change from a fraction of an MeV to almost 2 MeV by the inclusion of tensor force, indicating a strong impact of the tensor force on subbarrier fusion. The tensor force could indeed play a large role in the fusion of nuclei, with spin-unsaturated systems seeing a systematic increase in ion-ion barrier height and width. Furthermore, this fusion hindrance is partly due to static, ground-state effects from the inclusion of the tensor force, though additional hindrance appears when studying nuclear dynamics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic Heavy-Ion Theory: Final Report, February 2014-June 2015

The Vanderbilt nuclear theory group conducts research in the areas of low-energy nuclear reactions and in neutrino oscillations. Specially, we study dynamics of nuclear reactions microscopically, in particular for neutron-rich nuclei which will be accessible with current and future radioactive ion beam facilities. The neutrino work concentrates on constructing computational tools for analyzing neutrino oscillation data. The most important of these is the analysis of the Super K atmospheric data. Our research concentrates on the following topics which are part of the DOE Long-Range Plan: STUDIES OF LOW-ENERGY REACTIONS OF EXOTIC NUCLEI (Professors Umar and Oberacker), including sub-barrier fusion cross sections, capture cross sections for superheavy element production, and nuclear astrophysics applications. Our theory project is strongly connected to experiments at RIB facilities around the world, including NSCL-FRIB (MSU) and ATLAS-CARIBU (Argonne). PHENOMENOLOGY OF NEUTRINO OSCILLATIONS (Prof. Ernst), extracting information from existing neutrino oscillation experiments and proposing possible future experiments in order to better understand the oscillation phenomenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of New Experimental Methods for Correlated Operando Surface/Gas Characterization

The predictive understanding of catalytic surface reactions requires accurate microkinetic models, and while decades of work has been devoted to the elucidation of the reaction steps in these models, many open questions remain. One key issue is a lack of approaches enabling the local spatially resolved assessment of catalytic activity over a surface. In this report, we detail efforts to develop a new diagnostic approach to solve this problem. The approach is based upon laser resonance enhanced multiphoton ionization of reaction products emitted into the gas phase followed by spatially resolved imaging of the resultant ions or electrons. Ion imaging is pursued with a velocity-selected spatially resolved ion imaging microscope, while electron imaging was attempted in a low energy electron microscope. Successful demonstration of the ion imaging microscope coupled with the development of transport simulations shows promise for a revolutionary new tool to assess local catalytic activity

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Focused Ion Beam Scanning Electron Microscope Study of Microstructural Evolution of Single Tin Particle Anode for Li-Ion Batteries

Tin (Sn) is a potential anode material for high-energy density Li-ion batteries because of its high capacity, safety, abundance and low cost. However, Sn suffers from large volume change during cycling, leading to fast degradation of the electrode. For the first time, the microstructural evolution of micrometer-sized single Sn particle was monitored by focused-ion beam (FIB) polishing and scanning electron microscopy (SEM) imaging during electrochemical cycling by in situ FIB-SEM. Our results show the formation and evolution of cracks during lithiation, evolution of porous structure during delithiation and volume expansion/contraction during cycling. The electrochemical performance and the microstructural evolution of the Sn microparticle during cycling are directly correlated, which provides insights for understanding Sn-based electrode materials.

25 ENERGY STORAGE↗

Further investigation of the characteristics of nodular defects

To increase the understanding of the damage sensitivity of nodular defects and provide exact evidence for theoretical study, the structures and the damage behavior of nodular defects in electron-beam deposited mirrors of HfO2/SiO2 are systemically investigated with a double-beam microscope (focused ion beam, scanning electron microscope). Nodular defects are classified into two kinds. In one kind the boundaries between nodules and the surrounding layers have become continuous for the last deposited materials, and in the other there are discontinuous boundaries between nodules and the surrounding layers. Nodular defects of the first kind typically have low domes, and the second have high domes. Laser damage experiments show that nodular defects of the first kind usually have a high laser resistance, and the laser-induced damage thresholds are limited in the second class of nodules. The dominant parameter of nodular defects related to damage is the height of the nodular defect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new ion sensing deep atomic force microscope

Here we describe a new deep atomic force microscope (AFM) capable of ion sensing. A novel probe assembly incorporates a micropipette that can be used both for sensing ion currents and as the tip for AFM imaging. The key advance of this instrument over previous ion sensing AFMs is that it uses conventional micropipettes in a novel suspension system. This paper focuses on sensing the ion current passively while using force feedback for the operation of the AFM in contact mode. Two images are obtained simultaneously: (1) an AFM topography image and (2) an ion current image. As an example, two images of a MEMS device with a microchannel show peaks in the ion current as the pipette tip goes over the edges of the channel. This ion sensing AFM can also be used in other modes including tapping mode with force feedback as well as in non-contact mode by utilizing the ion current for feedback, as in scanning ion conductance microscopy. The instrument is gentle enough to be used on some biological samples such as plant leaves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thick beryllium coatings by magnetron sputtering

Thick (>150 {micro}m) beryllium coatings are studied as an ablator material of interest for fusion fuel capsules for the National Ignition Facility (NIF). As an added complication, the coatings are deposited on mm-scale spherical substrates, as opposed to flats. DC magnetron sputtering is used because of the relative controllability of the processing temperature and energy of the deposits. We used ultra small angle x-ray spectroscopy (USAXS) to characterize the void fraction and distribution along the spherical surface. We investigated the void structure using a combination focused ion beam (FIB) and scanning electron microscope (SEM), along with transmission electron microscopy (TEM). Our results show a few volume percent of voids and a typical void diameter of less than two hundred nanometers. Understanding how the stresses in the deposited material develop with thickness is important so that we can minimize film cracking and delamination. To that end, an in-situ multiple optical beam stress sensor (MOSS) was used to measure the stress behavior of thick Beryllium coatings on flat substrates as the material was being deposited. We will show how the film stress saturates with thickness and changes with pressure.

42 ENGINEERING↗

Ion and laser microprobes applied to the measurement of corrosion-produced hydrogen on a microscopic scale

An ion microprobe and a laser microprobe were used to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below the fracture surfaces of hot-salt stress-corroded titanium alloy specimens. This segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot-salt stress-corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress-corrosion and hydrogen embrittlement research, quality control, and field inspection applications.

Gray, H. R.↗

Electron backscatter diffraction studies of focused ion beam induced phase transformation in cobalt

A focused ion beam microscope was used to induce cubic to hexagonal phase transformation in a cobalt alloy, of similar composition to that of the binder phase in a hardmetal, in a controlled manner at 0°, 45° and 80° ion incident angles. The cobalt had an average grain size of ~ 20 μm, allowing multiple orientations to be studied, exposed to a range of doses between 6 × 10{sup 7} and 2 × 10{sup 10} ions/μm{sup 2}. Electron backscatter diffraction (EBSD) was used to determine the original and induced phase orientations, and area fractions, before and after the ion beam exposure. On average, less phase transformation was observed at higher incident angles and after lower ion doses. However there was an orientation effect where grains with an orientation close to (111) planes were most susceptible to phase transformation, and (101) the least, where grains partially and fully transformed at varying ion doses. - Highlights: •Ion-induced phase change in FCC cobalt was observed at multiple incidence angles. •EBSD was used to study the relationship between grain orientation and transformation. •Custom software analysed ion dose and phase change with respect to grain orientation. •A predictive capability of ion-induced phase change in cobalt was enabled.

36 MATERIALS SCIENCE↗

From ground to excited electronic state dynamics of electron and ion irradiated graphene nanomaterials

Microscopes utilizing convergent electron and ion beams are emerging as powerful tools for both imaging and manipulating two-dimensional materials with atomic resolution, allowing the ultimate limits of nanofabrication to be realized. In this chapter, we detail the use of time-dependent electronic structure theory to determine the excited state properties and reactivity of functionalized graphene nanostructures. A time-dependent density functional theory treatment of electronic excitations of materials is presented, with specific emphasis on predicting the position-dependent electronic response of two-dimensional nanomaterials to electron beams. The method is demonstrated in a study highlighting the important role that electronic excitation can play in opening reaction pathways relevant to atomically precise defect manipulation in graphene. Finally, we provide some perspective on future development directions for methods of simulating nonequilibrium electronic and vibrational dynamics induced by electron/ion beams.

Lingerfelt, David↗

Application of NSUF Capabilities Towards Understanding the Emulation of High Dose Neutron Irradiations with Ion Beams

Development of new materials for current nuclear power plants (NPPs) or materials for new NPPs requires extensive research, development, and deployment programs. Central to these efforts, particularly for core internals, are studies on the microstructural and mechanical changes due to neutron irradiation. These radiation effects studies are typically completed using materials test reactors followed by expensive and time-consuming post-irradiation examinations (PIE). This sluggish approach has severely limited the nuclear materials field to develop new materials or verify materials for new reactor design use. It is also very difficult to achieve the high levels of damage proposed for future reactors. A logical approach to accelerating the field is the application of ion beams to simulate neutron damage, especially for high dose applications. Ion beams have been used for decades to study radiation effects but not to emulate high dose reactor irradiations. In this regard, new (or renewed) methods for ion beam irradiations, new developments in materials characterization, and greater understanding on the governing mechanisms controlling observed radiation effects have led to a need for further studies to refine the technique. A primary challenge is the ability to determine the ion irradiation conditions that produce microstructures and mechanical properties relevant to in-core neutron irradiation conditions. A large, multi-disciplinary, multi-laboratory program deemed the High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation has been formed to assess and overcome the challenges associated with emulating high dose neutron irradiations using ion beams. Central to this program is the use of dual-beam ion irradiations and corresponding neutron irradiations within the BOR-60 fast reactor. These irradiations have produced hundreds of specimens for microstructural and mechanical characterization. A significant issue regarding the samples is the radioactivity of the neutron irradiated specimens as well as the need to characterize both irradiation types using the same equipment to maintain consistency and repeatability. The use of the Nuclear Science User Facilities (NSUF) has been central towards overcoming the mentioned issues and thereby enabling robust PIE in both the ion and neutron irradiated specimens of interest. In particular, the electron microscopes housed within the Low Activation Materials Development and Analysis (LAMDA) facility at Oak Ridge National Laboratory (ORNL) - an NSUF partner facility - has been instrumental in gathering high quality data for analysis. This paper will briefly highlight the PIE efforts using the NSUF capabilities within LAMDA.

36 MATERIALS SCIENCE↗

In situ nanomechanical testing in focused ion beam and scanning electron microscopes

The recent interest in size-dependent deformation of micro- and nanoscale materials has paralleled both technological miniaturization and advancements in imaging and small-scale mechanical testing methods. Here we describe a quantitative in situ nanomechanical testing approach adapted to a dual-beam focused ion beam and scanning electron microscope. A transducer based on a three-plate capacitor system is used for high-fidelity force and displacement measurements. Specimen manipulation, transfer, and alignment are performed using a manipulator, independently controlled positioners, and the focused ion beam. Gripping of specimens is achieved using electron-beam assisted Pt-organic deposition. Local strain measurements are obtained using digital image correlation of electron images taken during testing. Examples showing results for tensile testing of single-crystalline metallic nanowires and compression of nanoporous Au pillars will be presented in the context of size effects on mechanical behavior and highlight some of the challenges of conducting nanomechanical testing in vacuum environments.

36 MATERIALS SCIENCE↗