Electron radiation effects on time-dependent dielectric breakdown in SiO2 films

An experiment testing the effect of ionizing radiation on breakdown characteristics of SiO2 films is presented. Silicon wafers were oxidized and metallized, and a capacitor array was etched into a control sample while the rest were first irradiated with 1 MeV electrons and then etched. Time-dependent dielectric tests were made on all the capacitors, and the average characteristics of 96 capacitors are illustrated graphically. The curves are consistent with the model of holes trapped in the SiO2 film during irradiation leading to a retarding field for positive ion emission and drift toward the interface. It is shown how an externally applied field is reduced by the trapped charge, and that changes in the dielectric breakdown properties of the SiO2 film after irradiation depend on the positive trapped charge near the metal interface.

Li, S. P.↗

The sunspot chromosphere-corona transition region

Data from simultaneous readings of the line intensities, Doppler shifts, and line widths of a sunspot ion emission lines between 1170-1700 A are reported. Subsonic and supersonic flows were observed in the same line of sight above the umbra. A reduction of coronal plasma over sunspots with an electron temperature exceeding 1,000,000 K was confirmed, concurrent with enhanced emission from the transition region plasma in the temperature range 200,000-1,000,000 K. The differential emission measure is noted to have been caused to shift because of the enhancement of the transition region plasma emission, where radiative losses dominated the energy balance. Calculations of the energy balance also indicated that a detected divergence in the enthalpy flux for the umbral downflows could balance the radiative losses in the electron temperature range 30,000-200,000 K.

Nicolas, K. R.↗

Outer satellite atmospheres: Their extended nature and planetary interactions

Model calculations for the brightness of the sodium cloud in Region A were performed to clarify the role played by the plasma torus sink in producing the east-west intensity asymmetry observed in the sodium D-lines. It was determined that the east-west electric field, proposed by Barbosa and Kievelson (1983) and Ip and Goertz (1983) to explain the dawn-dusk asymmetry in the torus ion emissions measured by the Voyager UVS instrument, could also produce the east-west sodium intensity asymmetry discovered earlier by Bergstralh et al. (1975, 1977). Model results for the directional features of the sodium cloud are also reported. The completion of the development of the Io potassium cloud model, progress in improving the Titan hydrogen torus model, and efforts in developing our model for hydrogen cometary atmospheres are also discussed.

Smyth, W. H.↗

Spectral observation of the soft X-ray background and of the North Polar Spur with solid state spectrometers

Soft X-ray diffuse background observations in the 0.3-1.5 keV interval of two sky regions, near the north galactic pole and the North Polar Spur (NPS) are reported. Data were taken with a solid-state spectrometer carried by a rocket. The near-polar region exhibited O VII ion emissions at 530 eV. A second component was not identified but was attributed to the Galactic Halo. Fe XVIII, Ne IX, and O VIII contributions were detected in the NPS, along with an enhancement at 1.35 keV from Mg XI lines. A two-temperature contour was fit to the spectra and chi-square confidence levels of 90 and 68 percent were obtained.

Rocchia, R.↗

Expected intensities of solar neon-like ions

A study of the expected intensities of the stronger solar neon-like ion emission lines, some not yet observed, is carried out to compare with the observational situation. The potential usefulness of the 2p5 3s(3P2) - 2p6 forbidden line as a density diagnostic is discussed, and new electric quadrupole lines in the soft X-ray range are noted. 'Observability diagrams' are presented as a convenient overview of the known and unobserved lines. The S VII resonance lines appear to have anomalous intensities.

Bhatia, A. K.↗

OH detection by Ford Motor Company

Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

Wang, Charles C.↗

Galileo Ultraviolet Spectrometer experiment

The Galileo ultraviolet spectrometer experiment uses data obtained by the Ultraviolet Spectrometer (UVS) mounted on the pointed orbiter scan platform and from the Extreme Ultraviolet Spectrometer (EUVS) mounted on the spinning part of the orbiter with the field of view perpendicular to the spin axis. The UVS is a Ebert-Fastie design that covers the range 113-432 nm with a wavelength resolution of 0.7 nm below 190 and 1.3 nm at longer wavelengths. The UVS spatial resolution is 0.4 deg x 0.1 deg for illuminated disk observations and 1 deg x 0.1 deg for limb geometries. The EUVS is a Voyager design objective grating spectrometer, modified to cover the wavelength range from 54 to 128 nm with wavelength resolution 3.5 nm for extended sources and 1.5 nm for point sources and spatial resolution of 0.87 deg x 0.17 deg. The EUVS instrument will follow up on the many Voyager UVS discoveries, particularly the sulfur and oxygen ion emissions in the Io torus and molecular and atomic hydrogen auroral and airglow emissions from Jupiter. The UVS will obtain spectra of emission, absorption, and scattering features in the unexplored, by spacecraft, 170-432 nm wavelength region. The UVS and EUVS instruments will provide a powerful instrument complement to investigate volatile escape and surface composition of the Galilean satellites, the Io plasma torus, micro- and macro-properties of the Jupiter clouds, and the composition structure and evolution of the Jupiter upper atmosphere.

Hord, C. W.↗

The Optical Spectrum of the Geminga Pulsar

We obtained an optical spectrum of the isolated pulsar Geminga at the Keck Observatory. The optical object is at the limit of spectroscopic capability of any telescope, with a continuum flux that is approx. 0.5% of the dark sky on Mauna Kea. With particular attention paid to the dominant systematics of sky subtraction in our observing and analysis methods, we attained approx. 0.1% systematics in heavily binned spectra. The resulting spectrum spanning 3700 - 8000 A has a flat power-law shape f(sub nu) proportional to nu(exp -0.8) and a broad dip over 6300 - 6500 A. Thermal radiation cannot explain the optical spectrum of Geminga. The dominant component can be modeled as either electron synchrotron emission and ion (proton) cyclotron absorption, or ion cyclotron emission, the latter in a 10(exp 11) G magnetic field.

Martin, Christopher↗

Two Types of Soft X-ray Spectra in Cataclysmic Variables

We present results of analyses of Chandra HETG soft X-ray spectra (Lambda = 1.5-25 A) of seven cataclysmic variables. We find that these spectra divide unambiguously into two distinct types. Spectra of the first type, consisting of EX Hya, V603 Aql, U Gem, and SS Cyg, are remarkably well fit by a simple cooling flow model, which assumes only steady-state isobaric radiative cooling. This model has only two free parameters, the maximum temperature, kT(sub max), which provides a rough measurement of the depth of the potential well, and the overall normalization, which provides a highly precise measurement of the total accretion rate. Spectra of the second type, consisting of V1223 Sgr, A Psc, and GK Per, are grossly inconsistent with a simple cooling flow model. They instead exhibit a hard continuum, and, in addition, show strong H-like and He-like ion emission but little Fe L-shell emission, which is consistent with expectations for line emission from a photoionized plasma. Using a simple photoionization model, we argue that the observed line emission for these sources can be driven entirely by the hard continuum. The physical significance of these two distinct types of X-ray spectra is also explored.

White, Nicholas E.↗

On the Isothermality of Solar Plasmas

Recent measurements have shown that the quiet unstructured solar corona observed at the solar limb is close to isothermal, at a temperature that does not appear to change over wide areas or with time. Some in dividual active loop structures have also been found to be nearly iso thermal both along their axis and across their cross-section. Even a complex active region observed at the solar limb has been found to be composed of three distinct isothermal plasmas. If confirmed, these r esults would pose formidable challenges to the current theoretical understanding of the thermal structure and heating of the solar corona. For example, no current theoretical model can explain the excess dens ities and lifetimes of many observed loops if the loops are in fact i sothermal. All of these measurements are based on the so-called emiss ion measure (EM) diagnostic technique that is applied to a set of opt ically thin lines under the assumption of isothermal plasma. It provi des simultaneous measurement of both the temperature and EM. However, no study has ever been carried out to quantify the uncertainties in the technique and to rigorously assess its ability to discriminate bet ween isothermal and multithermal plasmas. Such a study is the topic o f the present work. We define a formal measure of the uncertainty in the EM diagnostic technique that can easily be applied to real data. We here apply it to synthetic data based on a variety of assumed plas ma thermal distributions, and develop a method to quantitatively asse ss the degree of multithermality of a plasma.