Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Oxygenated Molecules measured with a Nitrate Chemical Ionization Mass Spectrometer

These files contain selected oxygenated compounds detected by chemical ionization mass spectrometry with nitrate reagent ion. Detected compounds were grouped by volatility and the time series of the most intense ions in each volatility class are provided here. Volatility (C*) in units of μg m^-3 was calculated using log_10(C*)=(n_ref -n_C)*b_C - (n_O - 3*n_N)*b_O - 2*(((n_O - 3n_N)*n_C) / (n_C + n_O - 3*n_N))*b_CO - n_N* b_N where n_ref = 25, b_c = 0.475m b_O = 0.2, b_N = -0.5, b_CO = 0.9, n_C is the number of carbon atoms in the ion formula, n_O is the number of oxygen atoms in the ion formula, and n_N is the number of nitrogen atoms in the ion formula. Volatility was calculated for each formula (with the nitrate anion excluded) and compounds were assigned into extremely low volatility (ELVOCs, C* < 10^−4.5 μg m^-3), low volatility (LVOCs, 10^−4.5 μg m^-3 ≤ C* < 10^−0.5 μg m^-3), or semi-volatile (SVOCs, 10^−0.5 μg m^-3 ≤ C* < 10^2.5 μg m^-3) bins. All ions were assumed to be detected with a collision-limited sensitivity and thus represent lower bound values. Values are reported as parts per trillion by volume mixing ratio.

Extremely low-volatility organic compounds↗

An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams

Several applications of external microbeam techniques demand a very accurate and controlled dose delivery. To satisfy these requirements when post-sample ion detection is not feasible, we constructed a transmission single-ion detector based on an ultra-thin diamond membrane. The negligible intrinsic noise provides an excellent signal-to-noise ratio and enables a hit-detection efficiency of close to 100%, even for energetic protons, while the small thickness of the membrane limits beam spreading. Moreover, because of the superb mechanical stiffness of diamond, this membrane can simultaneously serve as a vacuum window and allow the extraction of an ion microbeam into the atmosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Conceptual Approach for FT-ICR cell Harmonization Utilizing External Shim Electrodes

A key component of FT-ICR mass spectrometers is the trapped ion cell, where analyte ions are confined for excitation and detection. Recent advances in superconducting magnet technology make possible the construction of magnets with higher magnetic fields and regions of improved homogeneity, setting the stage for major advances in FT-ICR performance metrics. In particular, fitting next generation superconducting magnets with ICR cells incorporating harmonic trapping electric fields, suitably configured with electrodes for manipulating and detecting ions, will simultaneously improve resolving power, mass measurement accuracy, dynamic range and sensitivity of FT-ICR MS. Here, a focused conceptual approach for achieving cell harmonization is presented, using as a metric, the spatial uniformity of the radial electric field divided by radius. This new concept for cell harmonization utilizing external shims and two proof-of-principle examples for externally shimmed cell configurations developed using 3D potential calculations are described. These designs are based on a series of external electrodes that serve to generate the trapping potential and are electrically de-coupled from the detection and excitation electrodes. A nearly ideal 3D quadrupolar potential is achieved throughout the cell volume while simplifying electrical and mechanical connections for FT-ICR cells.

Environmental Molecular Sciences Laboratory↗

Extension of the Focusable Mass Range in Distance-of-Flight Mass Spectrometry with Multiple Detectors

Since the underlying theory of Distance-of-Flight Mass Spectrometry (DOFMS) was reported in 2007,[1] laboratory results[2, 3] have proven its practical viability. However, these previous implementations of DOFMS considered ion detection only over narrow DOF-detection windows, with 25-mm being the greatest detection length explored. These small mass windows cannot be used to evaluate how DOFMS focusing performs over greater DOF detection lengths and mass ranges. In the present study, we expand on previous studies by placing two spatially selective ion detectors along the detection plane of the DOFMS instrument. Ion signals are simultaneously collected from both DOF detectors in order to simulate DOFMS performance with a longer spatially selective ion detector.

Gundlach-Graham, Alexander W↗

Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

43 PARTICLE ACCELERATORS↗

Intensity-Field Correlation of Single-Atom Resonance Fluorescence

We report measurements of an intensity-field correlation function of the resonance fluorescence of a single trapped {sup 138}Ba{sup +} ion. Detection of a photon prepares the atom in its ground state, and we observe its subsequent evolution under interaction with a laser field of well-defined phase. We record the regression of the resonance fluorescence source field. This provides a direct measurement of the field of the radiating dipole of a single atom and exhibits its strong nonclassical behavior. In the setup, an interference measurement is conditioned on the detection of a fluorescence photon.

74 ATOMIC AND MOLECULAR PHYSICS↗

The response of a fast scintillator screen (YAP:Ce) to low energy ions (0-40 keV) and its use to detect fast-ion-loss in stellarator TJ-II

A systematic study of scintillation materials was undertaken to improve the time resolution of the fast ion diagnostic currently installed at TJ-II stellarator. It was found that YAP:Ce (formula YAlO{sub 3}:Ce, Yttrium Aluminum Perovskite doped with Cerium) ionoluminescence offers better sensitivity and time response compared to the standard detector material, SrGa{sub 2}S{sub 4}:Eu (TG-Green), currently used in TJ-II. A comparison between both materials was carried out by irradiating them with H{sup +} ions of up to 40 keV using a dedicated laboratory setup. It is found that for the low energy ions of interest at TJ-II, YAP:Ce offers 20 times higher sensitivity than TG-Green and much faster decay time, 27 ns versus 540 ns. It is expected that the use of YAP:Ce in combination with a faster data acquisition and an ion counting software as part of the TJ-II ion luminescent probe will provide 20 times faster data on ion loss.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of ion emission of an extreme ultraviolet generating discharge produced Sn plasma

The ion emission of a Sn-based discharge produced extreme ultraviolet producing plasma is characterized with the combined use of different time-of-flight techniques. An electrostatic ion spectrometer is employed to measure the average charge distribution of the emitted Sn ions. A dedicated Faraday cup configuration is used to measure the total ion flux from the source for different discharge energies. High-energy Sn ions emitted by the plasma with energies up to 100 keV have been identified. The number of high-energy ions increases for higher electrical input energy into the plasma while the signal associated with the expanding plasma ions does not show such dependence. The ion energy distribution for a bulk of detected ions is calculated based on the Faraday cup measurements and compared with theoretical plasma expansion dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact molecular beam machine

We have developed a compact, low cost, modular, crossed molecular beam machine. The new apparatus utilizes several technological advancements in molecular beams valves, ion detection, and vacuum pumping to reduce the size, cost, and complexity of a molecular beam apparatus. We apply these simplifications to construct a linear molecular beam machine as well as a crossed-atomic and molecular beam machine. The new apparatus measures almost 50 cm in length, with a total laboratory footprint less than 0.25 m{sup 2} for the crossed-atomic and molecular beam machine. We demonstrate the performance of the apparatus by measuring the rotational temperature of nitric oxide from three common molecular beam valves and by observing collisional energy transfer in nitric oxide from a collision with argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

Detection Efficiency of a ToF Spectrometer from Heavy-Ion Elastic Recoil Detection

The detection efficiency of a time-of-flight system based on two micro-channel plates (MCP) time zero detectors plus a conventional silicon surface barrier detector was obtained from heavy ion elastic recoil measurements (this ToF spectrometer is mainly devoted to measurements of total fusion cross section of weakly bound projectiles on different mass-targets systems). In this work we have used beams of {sup 7}Li, {sup 16}O, {sup 32}S and {sup 35}Cl to study the mass region of interest for its application to measurements fusion cross sections in the {sup 6,7}Li+{sup 27}Al systems at energies around and above the Coulomb barrier (0.8V{sub B{<=}}E{<=}2.0V{sub B}). As the efficiency of a ToF spectrometer is strongly dependent on the energy and mass of the detected particles, we have covered a wide range of the scattered particle energies with a high degree of accuracy at the lowest energies. The different experimental efficiency curves obtained in that way were compared with theoretical electronic stopping power curves on carbon foils and were applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Suprathermal ions near the moon.

This paper reports some preliminary results from the suprathermal ion detectors deployed on the lunar surface by the Apollo 12 and 14 astronauts. Salient features of these results include: the possible observation of sporadic venting of gas from the lunar surface; evidence for a prompt ionization and acceleration mechanism operating in the lunar exosphere; and a preliminary measurement yielding approximately 1 month for the e-folding decay time for the heavier components of the exhaust gases from the Apollo lunar landing systems. Prominent phenomena from which these results have been derived are: (1) ion bursts of low to moderate energy seen in conjunction with lunar sunrise and sunset; (2) solar wind energy ions detected on the night side of the moon; (3) ions of several keV energy seen during the lunar sunset to midnight quadrant of the moon's orbit; (4) magnetosheath ion flux enhancements; (5) ion bursts generated by the lunar impact of the Apollo 13 Saturn upper stage; and (6) geomagnetic storm associated ion flux variations in the earth's magnetotail.

Freeman, J. W., Jr.↗

Ion velocities in a micro-cathode arc thruster

Ion velocities in the plasma jet generated by the micro-cathode arc thruster are studied by means of time-of-flight method using enhanced ion detection system (EIDS). The EIDS triggers perturbations (spikes) on arc current waveform, and the larger current in the spike generates denser plasma bunches propagating along with the mainstream plasma. The EIDS utilizes double electrostatic probes rather than single probes. The average Ti ion velocity is measured to be around 2 Multiplication-Sign 10{sup 4} m/s without a magnetic field. It was found that the application of a magnetic field does not change ion velocities in the interelectrode region while leads to ion acceleration in the free expanding plasma plume by a factor of about 2. Ion velocities of about 3.5 Multiplication-Sign 10{sup 4} m/s were detected for the magnetic field of about 300 mT at distance of about 100-200 mm from the cathode. It is proposed that plasma is accelerated due to Lorentz force. The average thrust is calculated using the ion velocity measurements and the cathode mass consumption rate, and its increase with the magnetic field is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel approach to increasing cocaine detection confidence utilizing ion mobility spectrometry

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. In terms of unwarranted delays of vessels and possible property damage, the accuracy of the analytical determination is very important. Analytical accuracy becomes critical when the data may be used in court actions as evidence. For this purpose, the U.S. Coast Guard has been investigating several confirmatory ion mobility spectrometry (IMS) field methods for the detection and identification of cocaine. This paper presents the findings of our investigations on the use of catalytic pyrolysis and base hydrolysis as confirmatory methods. The catalytic effects of various metals on the pyrolysis reaction are reported. In addition, the effects of several different ion mobility spectrometer sample transfer mediums and varying laboratory conditions on the base hydrolysis of the cocaine molecule are also be reported.

Jadamec, J. Richard↗

Modeling the response of a fast ion loss detector using orbit tracing techniques in a neutral beam prompt-loss study on the DIII-D tokamak

A numerical model describing the expected measurements of neutral beam prompt-losses by a newly commissioned fast ion loss detector (FILD) in DIII-D is presented. This model incorporates the well understood neutral beam deposition profiles from all eight DIII-D beamlines to construct a prompt-loss source distribution. The full range of detectable ion orbit phase space available to the FILD is used to calculate ion trajectories that overlap with neutral beam injection footprints. Weight functions are applied to account for the level of overlap between these detectable orbits and the spatial and velocity (pitch) properties of ionized beam neutrals. An experimental comparison is performed by firing each neutral beam individually in the presence of a ramping plasma current. Fast ion losses determined from the model are in agreement with measured losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable Hydrazone-Linked Covalent Organic Frameworks Containing O,N,O'-Chelating Sites for Fe(III) Detection in Water

Two stable crystalline hydrazone-linked covalent organic frameworks (COFs) (Bth-Dha and Bth-Dma) containing functional O,N,O'-chelating sites have been designed and successfully synthesized by the Schiff-base condensation reactions between benzene-1,3,5-tricarbohydrazide (Bth) and 2,5-dihydroxyterephthalaldehyde (Dha) or 2,5-dimethoxyterephthal-aldehyde (Dma), respectively. Bth-Dma exhibits strong fluorescence in the solid state and in an aqueous dispersion, while no fluorescence can be observed for Bth-Dha. Interestingly, the as-synthesized Bth-Dma can be used as a turn-off fluorescence sensor for the Fe(III) ion in aqueous solution with outstanding selectivity and sensitivity. Here, the recognition process can be attributed to the coordination interaction between Fe(III) ion and the O,N,O'-chelating sites in the pore wall of Bth-Dma COF, as verified by X-ray photoelectron spectroscopy and 1 H NMR spectroscopy. To the best of our knowledge, this is the first report on the rational design of luminescent COF with predesigned O,N,O'-chelating sites as a fluorescence sensor for highly selective and sensitive metal ion detection. This work may pave the way for designing luminescent COF sensors with functional binding sites for detecting specific metal ions.

36 MATERIALS SCIENCE↗

The DREAM Endstation at the Linac Coherent Light Source

Free-electron lasers (FEL), with their ultrashort pulses, ultrahigh intensities, and high repetition rates at short wavelength, have provided new approaches to Atomic and Molecular Optical Science. One such approach is following the birth of a photo electron to observe ion dynamics on an ultrafast timescale. Such an approach presents the opportunity to decipher the photon-initiated structural dynamics of an isolated atomic and molecular species. It is a fundamental step towards understanding single- and non-linear multi-photon processes and coherent electron dynamics in atoms and molecules, ultimately leading to coherent control following FEL research breakthroughs in pulse shaping and polarization control. A key aspect for exploring photoinduced quantum phenomena is visualizing the collective motion of electrons and nuclei in a single reaction process, as dynamics in atoms/ions proceed at femtosecond (10 –15 s) timescales while electronic dynamics take place in the attosecond timescale (10 –18 s). Here, we report on the design of a Dynamic Reaction Microscope (DREAM) endstation located at the second interaction point of the Time-Resolved Molecular and Optical (TMO) instrument at the Linac Coherent Light Source (LCLS) capable of following the photon–matter interactions by detecting ions and electrons in coincidence. The DREAM endstation takes advantage of the pulse properties and high repetition rate of LCLS-II to perform gas-phase soft X-ray experiments in a wide spectrum of scientific domains. With its design ability to detect multi-ions and electrons in coincidence while operating in step with the high repetition rate of LCLS-II, the DREAM endstation takes advantage of the inherent momentum conservation of reaction product ions with participating electrons to reconstruct the original X-ray photon–matter interactions. In this report, we outline in detail the design of the DREAM endstation and its functionality, with scientific opportunities enabled by this state-of-the-art instrument.

47 OTHER INSTRUMENTATION↗