Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

L-C Measurement Acquisition Method for Aerospace Systems

This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

Woodard, Stanley E.↗

Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

Simons, Rainee N.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Individually Identifiable Surface Acoustic Wave Sensors, Tags and Systems

A surface-launched acoustic wave sensor tag system for remotely sensing and/or providing identification information using sets of surface acoustic wave (SAW) sensor tag devices is characterized by acoustic wave device embodiments that include coding and other diversity techniques to produce groups of sensors that interact minimally, reducing or alleviating code collision problems typical of prior art coded SAW sensors and tags, and specific device embodiments of said coded SAW sensor tags and systems. These sensor/tag devices operate in a system which consists of one or more uniquely identifiable sensor/tag devices and a wireless interrogator. The sensor device incorporates an antenna for receiving incident RF energy and re-radiating the tag identification information and the sensor measured parameter(s). Since there is no power source in or connected to the sensor, it is a passive sensor. The device is wirelessly interrogated by the interrogator.

Hines, Jacqueline H.↗

RFID-Enabled Angular Position Sensing System

An angular position sensing system includes a first support with ring-shaped elements disposed thereon and spaced apart from one another in a curvilinear arrangement. Each ring-shaped element includes an electrically-conductive ring and an RFID integrated circuit electrically coupled to its electrically-conductive ring. A second support has an antenna coupled thereto that defines an electrically-conductive path commensurate in size and shape to at least a portion of the electrically-conductive ring. An interrogator transmits a signal to the antenna wherein electric current is generated along the antenna's electrically-conductive path and electromagnetic energy emanates from the antenna. Any ring-shaped element and its RFID integrated circuit energized by the electromagnetic energy generates in response a data transmission for receipt by the interrogator. A processor coupled to the interrogator derives information related to an angular position of one of the first support and second support using the data transmission.

Fink, Patrick W.↗

Frequency Multiplexed Radio Frequency Identification

A radio frequency identification (RFID) system for frequency multiplexing includes, in an exemplary embodiment, an RFID interrogator configured for generating an RFID signal, wherein a channel frequency of the RFID signal changes over time within an operating bandwidth; and one or more electromagnetic transmissive elements each extending between a first end thereof and a second end thereof, each of the electromagnetic transmissive elements electrically coupled with the RFID interrogator at the first end thereof, each of the electromagnetic transmissive elements comprising a frequency dependent load at the second end thereof and configured for transmitting the RFID signal from the RFID interrogator to the frequency dependent load, wherein the frequency dependent load presents different electromagnetic characteristics to the RFID signal transmitted to the frequency dependent load depending on the channel frequency of the RFID signal. Other embodiments include a method for frequency multiplexing including similar components.

Fink, Patrick W.↗

Basic Theory and Operating Principles of Optical Frequency Domain Reflectometry Measurement Systems as Applied to Fiber Bragg Grating Sensors

Optical frequency domain reflectometer (OFDR) systems provide for the interrogation of hundreds of fiber Bragg gratings (FBGs) within a single optical fiber. The coupling of FBG sensors to an OFDR interrogator results in a highly distributed measurement system utilizing sensors that are lightweight, immune to electromagnetic interference, and low-profile. This paper presents and explores a basic derivation of OFDR-FBG signals, the processing of those signals, the assembly of a basic OFDR system, an example measurement scenario, and the effects of specific component and configuration changes on interrogator speed, resolution, and accuracy.

optical frequency domain reflectometry↗

Remote measurements by telephone

Inexpensive device permits measurement and remote interrogation of variables such as voltage, temperature, pressure, or humidity by standard telephone equipment. Remote interrogation of wind direction and velocity, humidity, or water levels on flood-prone river are other possible representative uses for this device.

Miller, R. L.↗

Control means for a solid state crossbar switch

A control system for a solid state crossbar switch which allows a plurality of switch control and interrogation functions to be implemented by time sharing related circuitry is described. The crossbar switch includes a plurality of X ports and Y ports, each X-Y port intersection designating a specific X-Y intersection latch which controls a plurality of associated switches for interconnecting one set of data lines associated with the X port to another set of data lines associated with the Y port. The control system continuously and sequentially addresses each of the X-Y intersection latches at a 10 megahertz rate. During this addressing, the control circuitry includes a capability for interrogating each intersection latch for determining which are in a set condition, ensuring that only one X-Y intersection latch is set on an X row and Y column defining that latch, resetting all of the X-Y intersection latches, and determining which of the X-Y intersection latches are in a set condition.

Anderson, T. O.↗

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗

Self-Identifying Reflecting Targets

Proposed scheme for target identification requires no radiation of energy by target itself. Instead, target alters light beam reflected from itself back to interrogating station in unique way. Interrogator then identifies target from its signature impressed on returned beam. Selfidentifying target useful in surveying, navigation, and remote monitoring (for example, of mountain-climbing parties.)

Frazer, R. E.↗

Nondestructive evaluation of structural ceramics by photoacoustic microscopy

A photoacoustic microscopy (PAM) digital imaging system was developed and utilized to characterize silicon nitride material at the various stages of the ceramic fabrication process. Correlation studies revealed that photoacoustic microscopy detected failure initiating defects in substantially more specimens than microradiography and ultrasonic techniques. Photoacoustic microscopy detected 10 to 100 micron size surface and subsurface pores and inclusions, respectively, up to 80 microns below the interrogating surface in machined sintered silicon nitride. Microradiography detected 50 micron diameter fracture controlling pores and inclusions. Subsurface holes were detected up to a depth of 570 microns and 1.00 mm in sintered silicon nitride and silicon carbide, respectively. Seeded voids of 20 to 30 micron diameters at the surface and 50 microns below the interrogating surface were detected by photoacoustic microscopy and microradiography with 1 percent X-ray thickness sensitivity. Tight surface cracks of 96 micron length x 48 micron depth were detected by photoacoustic microscopy. PAM volatilized and removed material in the green state which resulted in linear shallow microcracks after sintering. This significantly limits the use of PAM as an in-process NDE technique.

Khandelwal, Pramod K.↗

Ferroelectric Memory Capacitors For Neural Networks

Thin-film ferroelectric capacitors proposed as nonvolatile analog memory devices. Intended primarily for use as synaptic connections in electronic neural networks. Connection strengths (synaptic weights) stored as nonlinear remanent polarizations of ferroelectric films. Ferroelectric memory and interrogation capacitors combined into memory devices in vertical or lateral configurations. Photoconductive layer modulated by light provides variable resistance to alter bias signal applied to memory capacitor. Features include nondestructive readout, simplicity, and resistance to ionizing radiation. Interrogated without destroying stored analog data. Also amenable to very-large-scale integration. Allows use of ac coupling, eliminating errors caused by dc offsets in amplifier circuits of neural networks.

Thakoor, Sarita↗

Electro-Optical High-Voltage Sensors

Electro-optical sensors for measuring high voltages developed for use in automatically controlled power-distribution systems. Sensors connected to optoelectronic interrogating equipment by optical fibers. Because sensitive material and optical fibers are all dielectric, no problem in electrically isolating interrogating circuitry from high voltage, and no need for voltage dividers. Sensor signals transmitted along fibers immune to electromagnetic noise at radio and lower frequencies.

Gottsche, Allan↗

Accurate GPS measurement of the location and orientation of a floating platform

This article describes the design and initial tests of the GPS portion of a system for making seafloor geodesy measurements. In the planned system, GPS antennas on a floating platform will be used to measure the location of an acoustic transducer, attached below the platform, which interrogates an array of transponders on the seafloor. Since the GPS antennas are necessarily some distance above the transducer, a short-baseline GPS interferometer consisting of three antennas is used to measure the platform's orientation. A preliminary test of several crucial elements of the system was performed. The test involved a fixed antenna on the pier and a second antenna floating on a buoy about 80 m away. GPS measurements of the vertical component of this baseline, analyzed independently by two groups using different software, agree with each other and with an independent measurement within a centimeter. The first test of an integrated GPS/acoustic system took place in the Santa Cruz Basin off the coast of southern California in May 1990. In this test a much larger buoy, designed and built at SIO, was equipped with three GPS antennas and an acoustic transducer that interrogated a transponder on the ocean floor. Preliminary analysis indicates that the horizontal position of the transponder can be determined with a precision of about a centimeter.

Purcell, G. H., Jr.↗

Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

In this Progress Report, we describe our continuing research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the inspection and characterization of complex composite structures. We explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize complex materials. As an initial step toward the application of linear array imaging technology to the interrogation of a wide range of complex composite structures, we present images obtained using an unmodified medical ultrasonic imaging system of two epoxy-bonded aluminum plate specimens, each with intentionally disbonded regions. These images are compared with corresponding conventional ultrasonic contact transducer measurements in order to assess whether these images can detect disbonded regions and provide information regarding the nature of the disbonded region. We present a description of a standoff/delay fixture which has been designed, constructed, and implemented on a Hewlett-Packard SONOS 1500 medical imaging system. This standoff/delay fixture, when attached to a 7.5 MHz linear array probe, greatly enhances our ability to interrogate flat plate specimens. The final section of this Progress Report describes a woven composite plate specimen that has been specially machined to include intentional flaws. This woven composite specimen will allow us to assess the feasibility of applying linear array imaging technology to the inspection and characterization of complex textile composite materials. We anticipate the results of this on-going investigation may provide a step toward the development of a rapid, real-time, and portable method of ultrasonic inspection and characterization based on linear array technology.

Miller, James G.↗

Determination of Elastic Moduli of Fiber-Resin Composites Using an Impulse Excitation Technique

The elastic moduli of graphite/epoxy and graphite/cyanate ester composite specimens with various laminate lay-ups was determined using an impulse excitation/acoustic resonance technique and compared to those determined using traditional strain gauge and extensometer techniques. The stiffness results were also compared to those predicted from laminate theory using uniaxial properties. The specimen stiffnesses interrogated ranged from 12 to 30 Msi. The impulse excitation technique was found to be a relatively quick and accurate method for determining elastic moduli with minimal specimen preparation and no requirement for mechanical loading frames. The results of this investigation showed good correlation between the elastic modulus determined using the impulse excitation technique, strain gauge and extensometer techniques, and modulus predicted from laminate theory. The flexural stiffness determined using the impulse excitation was in good agreement with that predicted from laminate theory. The impulse excitation/acoustic resonance interrogation technique has potential as a quality control test.

Viens, Michael J.↗

Research on the Problem of High-Precision Deployment for Large-Aperture Space-Based Science Instruments

The present paper summarizes results from an ongoing research program conducted jointly by the University of Colorado and NASA Langley Research Center since 1994. This program has resulted in general guidelines for the design of high-precision deployment mechanisms, and tests of prototype deployable structures incorporating these mechanisms have shown microdynamically stable behavior (i.e., dimensional stability to parts per million). These advancements have resulted from the identification of numerous heretofore unknown microdynamic and micromechanical response phenomena, and the development of new test techniques and instrumentation systems to interrogate these phenomena. In addition, recent tests have begun to interrogate nanomechanical response of materials and joints and have been used to develop an understanding of nonlinear nanodynamic behavior in microdynamically stable structures. The ultimate goal of these efforts is to enable nano-precision active control of micro-precision deployable structures (i.e., active control to a resolution of parts per billion).

Lake, Mark S.↗