Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Potential Indoor Worker Exposure From Handling Area Leakage: Dose Calculation Methodology and Example Consequence Analysis

The U.S. Department of Energy (DOE) is currently considering design options for preclosure facilities in a license application for a geologic repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain, Nevada. The Center for Nuclear Waste Regulatory Analyses (CNWRA) developed the PCSA Tool Version 3.0.0 software for the U.S. Nuclear Regulatory Commission (NRC) to aid in the regulatory review of a potential DOE license application. The objective of this paper is to demonstrate PCSA Tool modeling capabilities (i.e., a generic two-compartment, mass-balance model) for estimating radionuclide concentrations in air and radiological dose consequences to indoor workers in a control room from potential leakage of radioactively contaminated air from an adjacent handling area. The presented model computes internal and external worker doses from inhalation and submersion in a finite cloud of contaminated air in the control room and augments previous capabilities for assessing indoor worker dose. As a complement to the example event sequence frequency analysis in the companion paper, example consequence calculations are presented in this paper for the postulated event sequence. In conclusion: this paper presents a model for estimating radiological doses to indoor workers for the leakage of airborne radioactive material from handling areas. Sensitivity of model results to changes in various input parameters was investigated via illustrative example calculations. Indoor worker dose estimates were strongly dependent on the duration of worker exposure and the handling-area leakage flow rate. In contrast, doses were not very sensitive to handling-area exhaust ventilation flow rates. For the presented example, inhalation was the dominant radiological dose pathway. The two companion papers demonstrate independent analysis capabilities of the regulator for performing confirmatory calculations of frequency and consequence, which assist the assessment of worker safety during a risk-informed regulatory review of a potential DOE license application.

61 RADIATION PROTECTION AND DOSIMETRY↗

Indoor Radon Measurements from Residential Buildings with Basements in a Community with Potential LLRW Contamination - 19566

The Port Hope Area Initiative (PHAI) represents the Government of Canada's commitment to the cleanup and safe, local, long-term management of historic low-level radioactive waste (LLRW) in two Southern Ontario municipalities-Port Hope and Clarington. The PHAI (see reference for internet address) is based on community-recommended solutions for the cleanup and safe long-term management of approximately 1.7 million cubic meters of LLRW. It is currently one of Canada's largest environmental remediation projects at a cost of over one billion dollars. Canadian Nuclear Laboratories (CNL) is implementing the PHAI on behalf of Atomic Energy of Canada Limited, a Federal Crown Corporation. An initial characterization and remediation program in the urban area of Port Hope was conducted from 1976 to 1981. The waste is the result of radium and uranium processing in Port Hope by the former Federal Crown Corporation Eldorado Nuclear Limited between 1933 and 1988. One contaminant of concern in the LLRW is radium-226 (Ra-226) which may lead to elevated indoor levels of radon-222 (Rn-222) indoors. As part of CNL's implementation of the PHAI, Arcadis is conducting the Port Hope Project Property Radiological Survey of approximately 4,800 small-scale sites to identify 1) properties that have not been affected by historic operations and 2) properties that have residual historic low-level radioactive waste impacts requiring remediation either for soils or for interior contamination or both. Over the last six years, a component of the Small Scale Sites (SSS) characterization surveys have measured radon concentrations in essentially all buildings in Port Hope using alpha-track detectors. All properties had subsurface characterization including analytical characterization and lithology following the radon measurement reporting to measure if soil concentrations exceeded the PHAI Cleanup Criteria (PHAI CC) for Ra-226 of 0.29 Bq/g. Buildings with radon gas exceeding a trigger level of 200 becquerels per cubic meter (Bq/m{sup 3}) or those with ventilation systems required investigation of soil concentrations around the perimeter of the building. Ra-226 concentrations above the background level of 0.05 Bq/g due to LLRW sources were forwarded to create remedial action plans (RAPs) to remove the contamination near the building. The SSS surveys provide a substantive data set on the approximately 3,000 properties measured to date with interior Rn-222 gas measurements and descriptions of the physical characteristics of the buildings, the lithology of soils near the buildings and the measurements of Ra-226 concentration in the soils on the property. Consideration of the potential for contribution from non-LLRW Ra-226 from natural sources or coal ash was required on some properties. This paper describes the data and exploratory analysis of the relationship(s) between LLRW and non-LLRW factors that affect the variation in indoor radon concentrations. Historical information on the urban area, the measured Ra-226 concentration and the age of the building were correlated with radon concentrations. A large variety of native soils are found in the complex terrain and the type of native soil was correlated with the radon concentrations. A statistical analysis to address the impact of co-related explanatory variables to model indoor radon concentrations is planned when the SSS activities are complete. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Mixing on Acceptable Indoor Air Quality in Homes

Ventilation reduces occupant exposure to indoor contaminants by diluting or removing them. In a multi-zone environment such as a house, every zone will have different dilution rates and contaminant source strengths. The total ventilation rate is the most important factor in determining occupant exposure to given contaminant sources, but the zone-specific distribution of exhaust and supply air and the mixing of ventilation air can play significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage, air distribution system, and contaminant source and occupant locations. Most U.S. and Canadian homes have central heating, ventilation, and air conditioning systems, which tend to mix the air; thus, the indoor air in different zones tends to be well mixed for significant fractions of the year. This article reports recent results of investigations to determine the impact of air mixing on exposures of residential occupants to prototypical contaminants of concern. We summarize existing literature and extend past analyses to determine the parameters than affect air mixing as well as the impacts of mixing on occupant exposure, and to draw conclusions that are relevant for standards development and for practitioners designing and installing home ventilation systems. The primary conclusion is that mixing will not substantially affect the mean indoor air quality across a broad population of occupants, homes, and ventilation systems, but it can reduce the number of occupants who are exposed to extreme pollutant levels. If the policy objective is to minimize the number of people exposed above a given pollutant threshold, some amount of mixing will be of net benefit even though it does not benefit average exposure. If the policy is to minimize exposure on average, then mixing air in homes is detrimental and should not be encouraged. We also conclude that most homes in the US have adequate mixing already, but that new, high-performance homes may require additional mixing. Also our results suggest that some differentiation should be made in policies and standards for systems that provide continuous exhaust, thereby reducing relative dose for occupants overall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Airborne Metagenome in an Indoor Urban Environment

The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters

This study explores the potential environmental and energy benefits of using activated carbon fiber (ACF) filters for air cleaning in HVAC systems. The parallel aims for the air cleaning system were to enable reduced indoor exposures to volatile organic compounds (VOCs) and to simultaneously allow reduced rates and energy consumption for outdoor-air ventilation. We evaluated the use of ACF media to adsorb VOCs from indoor air during repeated simulated 12-hour to 24-hour periods of occupancy. In a cyclic regeneration process, VOCs were desorbed from the ACF media and vented outdoors to enable the next cycle of air cleaning. The VOC removal efficiency of the ACF media was measured using a 9.5-cm 2 ACF specimen exposed to a mixture of VOCs that included toluene, benzene, o-xylene, 1-butanol, limonene, undecane and formaldehyde at 29 °C and 30 percent relative humidity. The concentrations of these model pollutants upstream of the ACF media were in the range 20 to 30 ppb, to simulate realistic conditions. Velocities through the ACF media were typical of those in normal particle filter systems (~ 0.5 m s -1 ). Initial tests were conducted to develop a modified multi-component Freundlich isotherm and estimate the maximum adsorption capacity of the media, which was determined to be 90 mg VOC per gram of ACF. Three different ACF regeneration methods were explored using relatively cleaner outdoor air under ambient conditions, with this air humidified, and with the filter heated. It was found that heating the ACF media to ~150 °C by circulation of a DC current through the fibers for a short period (15 minutes) yielded the best VOC removal results, allowing for subsequent consistent removal efficiencies of 70-80 percent for most VOCs. Regeneration with unheated outdoor air was also effective and used less energy (subsequent removal efficiency was 50-60 percent for most VOCs). ACF did not perform as well in eliminating formaldehyde, for which a maximum removal of 25-30 percent was achieved with heated regeneration. A mass balance model indicated that the combination of ACF air cleaning and a 50percent reduction in ventilation will decrease indoor concentrations of VOCs by 60 percent to 80 percent and reduce formaldehyde concentrations by 12 percent to 40 percent. Energy modeling indicated the potential to reduce the energy required for heating and cooling of ventilation air by 35 percent to almost 50 percent.

54 ENVIRONMENTAL SCIENCES↗

The impacts of building characteristics, social psychological and cultural factors on indoor environment quality productivity belief

Indoor environmental quality (IEQ) plays a key role in determining occupants' productivity at work; however, analyses of the interconnected factors among building physical, attitudinal, social and demographic components in one study are lacking. To fill this research gap, this study investigates these interconnected factors' influence on occupants’ IEQ-productivity belief, defined as a personal, subjective evaluation of the linkage between the impacts of five IEQ aspects (the quality of indoor temperature, air, natural and electric lighting, and acoustics) and productivity. A cross-sectional survey data was collected in university offices from six countries (Brazil, Italy, Poland, Switzerland, Taiwan and the U.S.). Results of multiple linear regression models indicate that IEQ satisfaction is the strongest positive predictor of the IEQ-productivity belief and this relationship is stronger in private offices. Country of residence is the second primary predictor. Several attitudinal-behavioral factors, including thermal comfort, perceived ease of controlling indoor environmental features, and attitudes toward sharing controls are all positively associated with IEQ-productivity belief. Interestingly, the level of control accessibility to light switches has the strongest impact as opposed to other controls. On the other hand, group norms and conformity intention are not significant predictors. Regarding demographics, men are more likely than women to perceive the IEQs to have positive impacts on their productivity, without considering other variables in the regression model; however, women are more likely than men to consider all IEQs as having positive impacts on productivity, after considering other variables. Furthermore, our findings provide suggestions for prioritizing wellness in the workplace since the early design stage.

99 GENERAL AND MISCELLANEOUS↗

Smart ventilation energy and indoor air quality performance in residential buildings: A review

To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and the Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2 , humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Outdoor and indoor air quality and cognitive ability in young children

Highlights: • Outdoor and indoor air quality and cognitive ability in early childhood is explored. • Long-term but not short-term effects of outdoor NO{sub 2} on verbal ability at age 3 found. • Exposure to indoor damp or condensation predicted lower cognitive ability at age 3. • Secondhand smoke exposure associated with lower cognitive ability at age 3. This study examined outdoor and indoor air quality at ages 9 months and 3 years and their association with cognitive ability at age 3 in England and Wales.

54 ENVIRONMENTAL SCIENCES↗

Indoor Radon Concentration Levels in Najran Region, Saudi Arabia

Measurement of indoor radon concentration was performed in Najran region in the south west of Saudi Arabia, using CR-39 dosimeter. Despite many previous studies on indoor radon concentrations in Saudi Arabia, the data available are still limited. The objective of this study, which is the first of its kind in the region, is to have preliminary data of radon in this region. Such measurement will contribute towards further studies in this region of Saudi Arabia. The indoor radon concentration was measured in the villages of Fara Al-Jabal and Badr Al-Janoob (about 2000 m above sea level), Hadadah and Al-Khanig (about 1700 m above sea level). It was found that radon distribution in these villages is normal skewed to the right, with a range of 9{+-}5 to 163{+-}32 Bqm{sup -3} and an average of 49{+-}2 Bqm{sup -3}. It was also found that the average radon concentration is independent of altitude. Our findings show that the values are below the safe limit of 150 Bqm{sup -3} set by the Environmental Protection Agency (EPA) of the USA

54 ENVIRONMENTAL SCIENCES↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Indoor Wireless Localization of Uncooperative Sources Using a Ray Tracing Model

Indoor geolocation of radio frequency (RF) trans- mitters is challenging due to site-specific multipath effects, especially when the sources are uncooperative. A source being uncooperative means that a-priori the transmit time, location, and power are unknown. It is proposed to use a site-specific ray tracing model to generate realistic indoor RF responses, perform geolocation using multiple methods, and compare their performance. This work will look at two types of geolocation algorithms: (1) time-difference of arrival (TDOA) and (2) re- ceived signal strength Indicator (RSSI) fingerprinting or pattern- matching-based methods. An indoor space will be simulated with a grid of fixed receivers and a grid of transmit locations using Remcom’s Wireless InSite. Using the output of the Wireless InSite simulation the response from any given transmit location can be generated and used to evaluate geolocation performance.

indoor source localization, Wireless InSite, re- c↗

Probabilistic modeling of the indoor climates of residential buildings using EnergyPlus

The indoor air temperature and relative humidity in residential buildings significantly affect material moisture durability, HVAC system performance, and occupant comfort. Therefore, indoor climate data is generally required to define boundary conditions in numerical models that evaluate envelope durability and equipment performance. However, indoor climate data obtained from field studies is influenced by weather, occupant behavior and internal loads, and is generally unrepresentative of the residential building stock. Likewise, whole-building simulation models typically neglect stochastic variables and yield deterministic results that are applicable to only a single home in a specific climate. The

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Indoor risk factors for cough and their relation to wheeze and sensitization in Chilean young adults

We assessed the effects of indoor risk factors, including smoking, on different types of cough and on cough and wheeze in combination. Our sample was composed of 1232 men and women residing in a semi-rural area of Chile. We used a standardized questionnaire, sensitization to 8 allergens, and bronchial hyperresponsiveness to methacholine to assess cough and wheeze characteristics. Information was gathered on dampness, mold, ventilation, heating, housing quality, smoking, and environmental tobacco smoke exposure. Most exposures were associated with cough alone or cough in combination with wheeze. Smoking, past smoking, and environmental tobacco smoke exposure were strongly associated with dry cough and wheeze. The use of coal for heating was associated with dry cough. Leaks, mold, and lack of kitchen ventilation were associated with cough and wheeze. Nocturnal cough and productive cough were associated with specific types of sensitization, but dry cough was not. Productive cough was associated with hyperresponsiveness to methacholine. Several different types of indoor exposures, including environmental tobacco smoke exposure, are important contributors to morbidity associated with cough and wheeze. A vigorous preventive strategy designed to lower exposures to indoor risk factors would lower rates of respiratory morbidity.

01 COAL, LIGNITE, AND PEAT↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in the ZEBRAlliance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. Researchers have primarily addressed these two areas independently because of the assumption that their goals have to be mutually exclusive. This assumption is based on the fact that the typical mechanism to reduce the concentration of indoor air pollutants has been dilution through increased ventilation, which causes heating, ventilation and air conditioning (HVAC) units to consume more energy. High-performance homes aim to provide the essential energy end-uses (for example, water heating, refrigeration, space heating, and air conditioning) in an energy efficient manner. Given that IAQ is among these essential energy end-uses, we investigated means to optimize the concentration of indoor air pollutants and ventilation energy demands. To this end, we conducted tests in four houses located in Oak Ridge, TN, that were 11 to 20 months old, energy efficient (i.e., expected to consume 50% less energy than a house built per the 2006 International Residential Code), airtight (i.e., natural ventilation rate ~0.02 to 0.2 h -1 ), unoccupied, and unfurnished. Our evaluation consisted of identifying air pollutants of concern in these homes that could generally serve as indicators of IAQ, and conducting field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants.

formaldehyde↗

Indoor Environmental Quality Benefits of Apartment Energy Retrofits

Sixteen apartments serving low-income populations in three buildings were retrofit with the goal of simultaneously reducing energy consumption and improving indoor environmental quality (IEQ). Retrofit measures varied among apartments and included, among others, envelope sealing, installation of continuous mechanical ventilation systems, upgrading bathroom fans and range hoods, attic insulation, replacement of heating and cooling systems, and adding wall-mounted particle air cleaners. IEQ parameters were measured, generally for two one-week periods before and after the retrofits. The measurements indicate an overall improvement in IEQ conditions after the retrofits. Comfort conditions, bathroom humidity, and concentrations of carbon dioxide, acetaldehyde, volatile organic compounds, and particles generally improved. Formaldehyde and nitrogen dioxide levels decreased in the building with the highest concentrations, were unchanged in a second building, and increased in a third building. IEQ parameters other than particles improved more in apartments with continuous mechanical ventilation systems installed. In general, but not consistently, larger percent increases in air exchange rates were associated with larger percent decreases in indoor levels of the pollutants that primarily come from indoor sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗