Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INCIDENT RAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electroform replication of grazing incidence X-ray optics

Work to produce mirrors via electroform replication is reported. Work on small (6 cm by 9 cm) cylindrical pieces and on 40 cm long by 12 cm wide Wolter shaped mirrors is summarized. It is shown that electroforming is a viable technique for producing relatively inexpensive grazing incidence X-ray optics, as long as modest resolution (1 min of arc) and size (12 cm diameter by 40 cm long) are specified.

Ulmer, M. P.↗

Grazing incidence X-ray reflectivity - Studies for the AXAF observatory

The energy bandwidth and total throughput of a grazing incidence optics system is a strong function of the X-ray reflectivity of the surface coating. In support of the Advanced X-ray Astrophysics Facility (AXAF), studies are underway to evaluate and characterize the reflectivity of potential AXAF coatings. Here we report on results obtained for Au, Ir, and Ni coatings produced by electron-beam evaporation, evaporation with ion-assist, and sputtering. Effects of coating thickness and deposition angle have been evaluated at 6.4 and 8.1 keV; the highest reflectivities are those of the thinner, about 200 A vs about 700 A, coatings. While considerable variations exist, the best Ir samples have higher reflectivity than any of the Au coatings. Data results have been compared with models for theoretical reflectivity, particularly with regard to the effective density of the coatings. Independent measurements of the coating densities have been carried out for comparison with the reflectivity results.

Slane, P.↗

MaGIXS 2: Preparations for the Second Flight of the Marshall Grazing Incidence X-ray Spectrometer

Overview MaGIXS is a slitless soft X-ray (SXR) imaging spectrometer designed to observe solar active regions. - The instrument produces spatially resolved SXR spectra, known as “overlappograms.” (Athiray et al. 2019 & Champey et al., 2022) The first sounding rocket flight of the Marshall Grazing Incidence X-ray Spectrometer occurred on July 30, 2021 from the White Sands Missile Range, New Mexico. - Spectrally pure images of X-ray bright points were obtained through the inversion of overlappograms, e.g. Fig. 3 (Savage et al., 2022). MaGIXS 2 is a simplified version of the original design, less the spectrometer mirror pair. - Eliminating the spectrometer mirror pair improves spatial resolution, increases effective area and the field of view (Table 1). No field stop in this design, data will be an overlappogram with the same spatial and spectral plate scale.

x-ray spectrometer, x-ray optics, solar corona, so↗

An Overview of MaGIXS-2, The Second Flight of the Marshall Grazing Incidence X-ray Spectrometer

MaGIXS is a slitless soft X-ray (SXR) imaging spectrometer designed to observe solar active regions. - The instrument produces spatially resolved SXR spectra, known as “overlappograms.” (Athiray et al. 2019 & Champey et al., 2022) The first sounding rocket flight of the Marshall Grazing Incidence X-ray Spectrometer occurred on July 30, 2021 from the White Sands Missile Range, New Mexico. - Spectrally pure images of X-ray bright points were obtained through the inversion of overlappograms, e.g. Fig. 3 (Savage et al., 2022). MaGIXS 2 is a simplified version of the original design, less the spectrometer mirror pair. - Eliminating the spectrometer mirror pair improves spatial resolution, increases effective area and the field of view (Table 1). No field stop in this design, data will be an overlappogram with the same spatial and spectral plate scale.

x-ray spectrometer, x-ray optics, solar corona, so↗

Spherical mirror grazing incidence x-ray optics

An optical system for x-rays combines at least two spherical or near spherical mirrors for each dimension in grazing incidence orientation to provide the functions of a lens in the x-ray region. To focus x-ray radiation in both the X and the Y dimensions, one of the mirrors focusses the X dimension, a second mirror focusses the Y direction, a third mirror corrects the X dimension by removing comatic aberration and a fourth mirror corrects the Y dimension. Spherical aberration may also be removed for an even better focus. The order of the mirrors is unimportant.

Cash, Jr., Webster C.↗

Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard B.↗

Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

Zhang, William↗

A normal incidence X-ray telescope sounding rocket payload

Progress is reported on the following major activities on the X-ray telescope: (1) complete design of the entire telescope assembly and fabrication of all front-end components was completed; (2) all rocket skin sections, including bulkheads, feedthroughs and access door, were specified; (3) fabrication, curing and delivery of the large graphite-epoxy telescope tube were completed; (4) an engineering analysis of the primary mirror vibration test was completed and a decision made to redesign the mirror attachment system to a kinematic three-point mount; (5) detail design of the camera control, payload and housekeeping electronics were completed; and (6) multilayer mirror plates with 2d spacings of 50 A and 60 A were produced.

Golub, L.↗

A normal incidence X-ray telescope

The postflight performance evaluation of the X-ray telescope was summarized. All payload systems and subsystems performed well within acceptable limits, with the sole exception of the light-blocking prefilters. Launch, flight and recovery were performed in a fully satisfactory manner. The payload was recovered in a timely manner and in excellent condition. The prefilter performance analysis showed that no X-ray images were detected on the processed flight film. Recommendations for improved performance are listed.

Golub, Leon↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

Multilayer and grazing incidence X-ray/EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991

The present conference discusses the Advanced X-ray Astrophysics Facility (AXAF) calibration by means of synchrotron radiation and its X-ray reflectivity, X-ray scattering measurements from thin-foil X-ray mirrors, lobster-eye X-ray optics using microchannel plates, space-based interferometry at EUV and soft X-ray wavelengths, a water-window imaging X-ray telescope, a graded d-spacing multilayer telescope for high energy X-ray astronomy, photographic films for the multispectral solar telescope array, a soft X-ray ion chamber, and the development of hard X-ray optics. Also discussed are X-ray spectroscopy with multilayered optics, a slit aperture for monitoring X-ray experiments, an objective double-crystal spectrometer, a Ly-alpha coronagraph/polarimeter, tungsten/boron nitride multilayers for XUV optical applications, the evaluation of reflectors for soft X-ray optics, the manufacture of elastically bent crystals and multilayer mirrors, and selective photodevices for the VUV.

Hoover, Richard B.↗

A Normal Incidence X-ray Telescope (NIXT) Sounding Rocket Payload

The following two papers, summarizing scientific results from the NIXT rocket program, are presented: (1) 'The Solar X-ray Corona,' - an introduction to the physics of the solar corona, with a major portion concerning a summary of results from the series of NIXT sounding rocket flights; and (2) 'Difficulties in Observing Coronal Structure.'

Golub, Leon↗

A Normal Incidence X-ray Telescope (NIXT) Sounding Rocket Payload

The solar corona, and the coronae of solar-type stars, consist of a low-density magnetized plasma at temperatures exceeding 10(exp 6) K. The primary coronal emission is therefore in the UV and soft X-ray range. The observed close connection between solar magnetic fields and the physical parameters of the corona implies a fundamental role for the magnetic field in coronal structuring and dynamics. Variability of the corona occurs on all temporal and spatial scales - at one extreme, as the result of plasma instabilities, and at the other extreme driven by the global magnetic flux emergence patterns of the solar cycle.

Golub, Leon↗