Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Study on the Properties of Ionized Metal Plasma Methodology on Titanium

Ionized Metal Plasma (IMP) deposition was used in depositing metal interconnection of titanium metal film. Inductively coupled plasma (ICP) was attached to chamber wall where it creates an electromagnetic field, thus, ionizing the sputtered metal atoms from target. The film morphology was observed by scanning electron microscope (SEM). Acoustic measurement of titanium film thickness showed that there was a comparable result with film resistance measured by 4-point probe. Results show that higher plasma density would cause tensile properties on the film stress.

36 MATERIALS SCIENCE↗

Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics

A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

43 PARTICLE ACCELERATORS↗

Study on a negative hydrogen ion source with hot cathode arc discharge

A negative hydrogen (H{sup −}) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H{sup −} beam with ε {sub N,} {sub RMS} = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I{sub e{sup −}}/I{sub H{sup −}} were experimentally studied. The discussion on the result, and opinions to improve the source were given.

43 PARTICLE ACCELERATORS↗

An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

43 PARTICLE ACCELERATORS↗

Diagnosis of energy transport in iron buried layer targets using an extreme ultraviolet laser

We demonstrate the use of extreme ultra-violet (EUV) laboratory lasers in probing energy transport in laser irradiated solid targets. EUV transmission through targets containing a thin layer of iron (50 nm) encased in plastic (CH) after irradiation by a short pulse (35 fs) laser focussed to irradiances 3 × 10{sup 16} Wcm{sup −2} is measured. Heating of the iron layer gives rise to a rapid decrease in EUV opacity and an increase in the transmission of the 13.9 nm laser radiation as the iron ionizes to Fe{sup 5+} and above where the ion ionisation energy is greater than the EUV probe photon energy (89 eV). A one dimensional hydrodynamic fluid code HYADES has been used to simulate the temporal variation in EUV transmission (wavelength 13.9 nm) using IMP opacity values for the iron layer and the simulated transmissions are compared to measured transmission values. When a deliberate pre-pulse is used to preform an expanding plastic plasma, it is found that radiation is important in the heating of the iron layer while for pre-pulse free irradiation, radiation transport is not significant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancement of highly charged ion beam production by superconducting ECR ion source SECRAL (invited)

At Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), the superconducting Electron Cyclotron Resonance (ECR) ion source SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) has been put into operation for about 10 years now. It has been the main working horse to deliver intense highly charged heavy ion beams for the accelerators. Since its first plasma at 18 GHz, R&D work towards more intense highly charged ion beam production as well as the beam quality investigation has never been stopped. When SECRAL was upgraded to its typical operation frequency 24 GHz, it had already showed its promising capacity of very intense highly charged ion beam production. And it has also provided the strong experimental support for the so called scaling laws of microwave frequency effect. However, compared to the microwave power heating efficiency at 18 GHz, 24 GHz microwave heating does not show the ω{sup 2} scale at the same power level, which indicates that microwave power coupling at gyrotron frequency needs better understanding. In this paper, after a review of the operation status of SECRAL with regard to the beam availability and stability, the recent study of the extracted ion beam transverse coupling issues will be discussed, and the test results of the both TE{sub 01} and HE{sub 11} modes will be presented. A general comparison of the performance working with the two injection modes will be given, and a preliminary analysis will be introduced. The latest results of the production of very intense highly charged ion beams, such as 1.42 emA Ar{sup 12+}, 0.92 emA Xe{sup 27+}, and so on, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of surface insulated-standard hybrid tungsten planar wire array Z-pinches at “QiangGuang-I” facility

The experimental results of the insulated-standard hybrid wire array Z pinches carried out on “QiangGuang-I” facility at Northwest Institute of Nuclear Technology were presented and discussed. The surface insulating can impose a significant influence on the dynamics and radiation characteristics of the hybrid wire array Z pinches, especially on the early stage (t/t{sub imp} < 0.6). The expansion of insulated wires at the ablation stage is suppressed, while the streams stripped from the insulated wires move faster than that from the standard wires. The foot radiation of X-ray is enhanced by increment of the number of insulated wires, 19.6 GW, 33.6 GW, and 68.6 GW for shots 14037S, 14028H, and 14039I, respectively. The surface insulation also introduces nonhomogeneity along the single wire—the streams move much faster near the electrodes. The colliding boundary of the hybrid wire array Z pinches is bias to the insulated side approximately 0.6 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR

The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40 Ar 12+ 1.4 emA, 129 Xe 26+ 1.1 emA, 129 Xe 30+ 0.36 emA, and 209 Bi 31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40 Ar 16+ , 15 eμA 40 Ar 18+ , 146 eμA 86 Kr 28+ , 0.5 eμA 86 Kr 33+ , 53 eμA 129 Xe 38+ , and 17 eμA 129 Xe 42+ . Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb 3 Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

47 OTHER INSTRUMENTATION↗

SOLAR ENERGETIC-PARTICLE RELEASE TIMES IN HISTORIC GROUND-LEVEL EVENTS

Ground-level events (GLEs) are large solar energetic-particle events with sufficiently hard spectra for GeV protons to be detected by neutron monitors at ground level. For each of 30 well-observed historic GLEs from four solar cycles, extending back to 1973, I have plotted onset times versus velocity{sup -1} for particles observed on the IMP-7 and 8, ISEE-3, Wind, and GOES spacecraft and by neutron monitors. A linear fit on such a plot for each GLE determines the initial solar particle release (SPR) time, as the intercept, and the magnetic path length traversed, as the slope, of the fitted line. Magnetic path lengths and SPR times are well determined by the fits and cannot be used as adjustable parameters to make particle and photon emission times coincide. SPR times follow the onsets of shock-induced type II radio bursts and the coronal height of the coronal mass ejection (CME)-driven shock at SPR time can be determined for GLEs spanning an interval of solar longitude of approx140 deg. For a given GLE, all particle species and energies diverge from a single SPR point at a given coronal height and footpoint longitude of the field line to the Earth. These heights tend to increase with longitudinal distance away from the source, a pattern expected for shock acceleration. Acceleration for magnetically well-connected large GLEs begins at approx2 solar radii, in contrast to non-GLEs that have been found to be strongly associated with shocks above approx3 solar radii. The higher densities and magnetic field strengths at lower altitudes may be responsible for the acceleration of higher-energy particles in GLEs, while those GLEs that begin above 3R {sub S} may compensate by having higher shock speeds. These results support the joint dependence of maximum particle energy on magnetic field strength, injected particle density, and shock speed, all predicted theoretically.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FAR-INFRARED ROTATIONAL SPECTRUM OF ETHYLENE OXIDE

High-resolution FTIR spectra of ethylene oxide have been measured in the far-infrared region using synchrotron radiation. A total of 1182 lines between 15 and 73 cm{sup -1} were assigned, with J{sub max} = 64, expanding upon previous studies that had recorded spectra up to 12 cm{sup -1}, J{sub max} = 49. All available data were co-fitted to provide greatly imp- roved rotational constants for the ground vibrational state that are capable of predicting transitions up to 73 cm{sup -1}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of influence of radial matcher section end shape on RFQ cavity frequency

To investigate the feasibility of using a form cutter to machine the Radial Matcher Section (RMS) of the Radio Frequency Quadrupole (RFQ) for the Accelerator Driven System (ADS) project at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS), the influence of RMS end shape on the RFQ cavity frequency is studied in this paper. The results indicate that using a form cutter to machine the RMS of an RFQ will indeed influence the cavity frequency. The RMS end shape will give more influence to a shorter RFQ cavity. Finally, for the 4.2 m ADS RFQ, the influence is negligible, which means that a form cutter can be used to machine the RMS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraining explosive nucleosynthesis by indirect reaction methods at storage rings using unstable beams in batch mode

Nuclear reaction studies on unstable isotopes can strongly help in improving our understanding of nucleosynthesis in stars. Indirect approaches to determining astrophysical reaction rates are increasingly common-place and undergoing continuous refinement. Of particular interest is the use of such indirect techniques at storage rings, which, among other aspects, allow to recycle rare unstable beams. Here, we propose to investigate the reaction rates of astrophysical interest using indirect methods (surrogate, Trojan horse, etc.) in reverse kinematics at the IMP-CAS storage ring. Long lived radioactive ion beams, produced remotely, can be accelerated, and made to interact with light targets. The proposed reactions are 85 Kr(p, p’γ), 85 Kr(d, pγ), constraining the neutron flux in an s-process branching point, 79 Se(p, p’γ), 79 Se(d, pγ), constraining the temperature in s-process nucleosyntheses, and 59 Fe(d, pγ), constraining core collapse supernovae.

Angelis, G. de [National Inst. of Nuclear Physics ↗

Dynamical eightfold way mesons in strongly coupled lattice QCD

We consider a 3+1 lattice QCD model with three quark flavors, local SU(3){sub c} gauge symmetry, global SU(3){sub f} flavor symmetry, in an imaginary-time formulation and with strong coupling (a small hopping parameter {kappa}>0 and a plaquette coupling {beta}>0, 0<{beta}<<{kappa}<<1). Associated with the model there is an underlying physical quantum mechanical Hilbert space H which, via a Feynman-Kac formula, enables us to derive spectral representations for correlations and obtain the low-lying energy-momentum spectrum exactly. Using the decoupling of hyperplane method and concentrating on the subspace H{sub e} subset of H of vectors with an even number of quarks, we obtain the one-particle spectrum showing the existence of 36 meson states from dynamical first principles, i.e. directly from the quark-gluon dynamics. The particles are detected by isolated dispersion curves w(p-vector) in the energy-momentum spectrum. Besides the SU(3){sub f} quantum numbers (total hypercharge, quadratic Casimir C{sub 2}, total isospin and its 3rd component), the basic excitations also carry spin labels. The total spin operator J and its z-component J{sub z} are defined using {pi}/2 rotations about the spatial coordinate axes and agree with the infinitesimal generators of the continuum for improper zero-momentum meson states. The eightfold way meson particles are given by linear combinations of these 36 states and can be grouped into three SU(3){sub f} nonets associated with the vector mesons (J=1, J{sub z}=0, {+-}1) and one nonet associated with the pseudoscalar mesons (J=0). Each nonet admits a further decomposition into a SU(3){sub f} singlet (C{sub 2}=0) and an octet (C{sub 2}=3). For {beta}=0, the particle dispersion curves are all of the form w(p-vector)=-2ln{kappa}-3{kappa}{sup 2}/2+(1/4){kappa}{sup 2}{sub j=1}{sup 3}2(1-cosp{sup j})+{kappa}{sup 4}r({kappa},p-vector), with p-vector(set-membership sign)(-{pi},{pi}]{sup 3} and |r({kappa},p-vector)|{<=}const. For the pseudoscalar mesons, r({kappa},p-vector) is jointly analytic in {kappa} and p{sup j}, for |{kappa}| and |Imp{sup j}| small. At {beta}=0 the meson masses are given by m({kappa})=-2ln{kappa}-3{kappa}{sup 2}/2+{kappa}{sup 4}r({kappa}), with r(0){ne}0 and r({kappa}) real analytic; for {beta}{ne}0 the nonsingular part of the mass, m({kappa},{beta})+2ln{kappa}, is jointly analytic in {kappa} and {beta}. For a fixed nonet, the mass of the vector mesons are independent of J{sub z} and are all equal within each octet. All singlet masses are also equal for the vector mesons. For {beta}=0, up to and including O({kappa}{sup 4}), for each nonet, the masses of the octet and the singlet are found to be equal. All members of each octet have identical dispersions. Other dispersion curves may differ. Indeed, there is a pseudoscalar, vector meson mass splitting (between J=0 and J=1) given by 2{kappa}{sup 4}+O({kappa}{sup 6}) at {beta}=0, analytic in {beta} and the splitting persists for {beta}<<{kappa}. Using a correlation subtraction method, we show the 36 meson states give the only spectrum in H{sub e} up to near the two-meson threshold of {approx_equal}-4ln{kappa}. Combining our present result with a similar one for baryons (of asymptotic mass -3ln{kappa}) shows that the model does exhibit confinement up to near the two-meson threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-direct-drive fusion target design with a high- Z gradient-density pusher shell

Laser-direct-drive fusion target designs with solid deuterium-tritium (DT) fuel, a high-Z gradient-density pusher shell (GDPS), and a Au-coated foam layer have been investigated through both 1D and 2D radiation-hydrodynamic simulations. Compared with conventional low-Z ablators and DT-push-on-DT targets, these GDPS targets possess certain advantages of being instability-resistant implosions that can be high adiabat (α ≥ 8) and low hot-spot and pusher-shell convergence (CR hs ≈ 22 and CR PS ≈ 17), and have a low implosion velocity (v imp < 3 × 10 7 cm/s). Using symmetric drive with laser energies of 1.9 to 2.5 MJ, 1D LILAC simulations of these GDPS implosions can result in neutron yields corresponding to >~50–MJ energy, even with reduced laser absorption due to the cross-beam energy transfer (CBET) effect. Two-dimensional DRACO simulations show that these GDPS targets can still ignite and deliver neutron yields from 4 to ~10 MJ even if CBET is present, while traditional DT-push-on-DT targets normally fail due to the CBET-induced reduction of ablation pressure. If CBET is mitigated, these GDPS targets are expected to produce neutron yields of >20 MJ at a driven laser energy of ~2 MJ. Here are the key factors behind the robust ignition and moderate energy gain of such GDPS implosions are as follows: (1) The high initial density of the high-Z pusher shell can be placed at a very high adiabat while the DT fuel is maintained at a relatively low-entropy state; therefore, such implosions can still provide enough compression ρR >1 g/cm 2 for sufficient confinement; (2) the high-Z layer significantly reduces heat-conduction loss from the hot spot since thermal conductivity scales as ~1/Z; and (3) possible radiation trapping may offer an additional advantage for reducing energy loss from such high-Z targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncovering Non-Fermi-Liquid Behavior in Hund Metals: Conformal Field Theory Analysis of an SU(2)×SU(3) Spin-Orbital Kondo Model

Hund metals have attracted attention in recent years due to their unconventional superconductivity, which supposedly originates from non-Fermi-liquid (NFL) properties of the normal state. When studying Hund metals using dynamical mean-field theory, one arrives at a self-consistent “Hund impurity problem” involving a multiorbital quantum impurity with nonzero Hund coupling interacting with a metallic bath. If its spin and orbital degrees of freedom are screened at different energy scales, T sp < T orb , the intermediate energy window is governed by a novel NFL fixed point, whose nature had not yet been clarified. We resolve this problem by providing an analytical solution of a paradigmatic example of a Hund impurity problem, involving two spin and three orbital degrees of freedom. To this end, we combine a state-of-the-art implementation of the numerical renormalization group, capable of exploiting non-Abelian symmetries, with a generalization of Affleck and Ludwig’s conformal field theory (CFT) approach for multichannel Kondo models. We characterize the NFL fixed point of Hund metals in detail for a Kondo model with an impurity forming an SU ( 2 ) × SU ( 3 ) spin-orbital multiplet, tuned such that the NFL energy window is very wide. The impurity’s spin and orbital susceptibilities then exhibit striking power-law behavior, which we explain using CFT arguments. We find excellent agreement between CFT predictions and numerical renormalization group results. Our main physical conclusion is that the regime of spin-orbital separation, where orbital degrees of freedom have been screened but spin degrees of freedom have not, features anomalously strong local spin fluctuations: the impurity susceptibility increases as χ sp imp ~ ω – γ , with γ > 1 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Horizontal transfer of a pathway for coumarate catabolism unexpectedly inhibits purine nucleotide biosynthesis

A microbe’s ecological niche and biotechnological utility are confirmed by its specific set of co-evolved metabolic pathways. The acquisition of new pathways, through horizontal gene transfer or genetic engineering, can have unpredictable consequences. In this work, we show that two different pathways for coumarate catabolism failed to function when initially transferred into Escherichia coli . Using laboratory evolution, we elucidated the factors limiting activity of the newly acquired pathways and the modifications required to overcome these limitations. Both pathways required host mutations to enable effective growth with coumarate, but the necessary mutations differed. In one case, a pathway intermediate inhibited purine nucleotide biosynthesis, and this inhibition was relieved by single amino acid replacements in IMP dehydrogenase. A strain that natively contains this coumarate catabolism pathway, Acinetobacter baumannii , is resistant to inhibition by the relevant intermediate, indicating that natural pathway transfers have faced and overcome similar challenges. Molecular dynamics simulation of the wild type and a representative single-residue mutant provide insight into the structural and dynamic changes that relieve inhibition. These results reflect how deleterious interactions can limit pathway transfer, that these interactions can be traced to specific molecular interactions between host and pathway, and how evolution or engineering can alleviate these limitations.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-I-28: Evaluating the Organ Dose From Computed Tomography Using Monte Carlo Calculations

Purpose: To evaluate organ doses from computed tomography (CT) using Monte Carlo (MC) calculations. Methods: A Philips Brilliance CT scanner (64 slice) was simulated using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The X-ray spectra and a bowtie filter for MC simulations were determined to coincide with measurements of half-value layer (HVL) and off-center ratio (OCR) profile in air. The MC dose was calibrated from absorbed dose measurements using a Farmer chamber and a cylindrical water phantom. The dose distribution from CT was calculated using patient CT images and organ doses were evaluated from dose volume histograms. Results: The HVLs of Al at 80, 100, and 120 kV were 6.3, 7.7, and 8.7 mm, respectively. The calculated HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 3%. For adult head scans (CTDIvol) =51.4 mGy), mean doses for brain stem, eye, and eye lens were 23.2, 34.2, and 37.6 mGy, respectively. For pediatric head scans (CTDIvol =35.6 mGy), mean doses for brain stem, eye, and eye lens were 19.3, 24.5, and 26.8 mGy, respectively. For adult chest scans (CTDIvol=19.0 mGy), mean doses for lung, heart, and spinal cord were 21.1, 22.0, and 15.5 mGy, respectively. For adult abdominal scans (CTDIvol=14.4 mGy), the mean doses for kidney, liver, pancreas, spleen, and spinal cord were 17.4, 16.5, 16.8, 16.8, and 13.1 mGy, respectively. For pediatric abdominal scans (CTDIvol=6.76 mGy), mean doses for kidney, liver, pancreas, spleen, and spinal cord were 8.24, 8.90, 8.17, 8.31, and 6.73 mGy, respectively. In head scan, organ doses were considerably different from CTDIvol values. Conclusion: MC dose distributions calculated by using patient CT images are useful to evaluate organ doses absorbed to individual patients.

60 APPLIED LIFE SCIENCES↗

SU-F-207-01: Comparison of Beam Characteristics and Organ Dose From Four Commercial Multidetector Computed Tomography Scanners

Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chamber and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.

60 APPLIED LIFE SCIENCES↗