Engineering PapersSearch

SEARCH · Engineering Papers

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Computing virtual dark-field X-ray microscopy images of complex discrete dislocation structures from large-scale molecular dynamics simulations

Dark-field X-ray microscopy (DFXM) is a novel diffraction-based imaging technique that non-destructively maps the local deformation from crystalline defects in bulk materials. While studies have demonstrated that DFXM can spatially map 3D defect geometries, it is still challenging to interpret DFXM images of the high-dislocation-density systems relevant to macroscopic crystal plasticity. This work develops a scalable forward model to calculate virtual DFXM images for complex discrete dislocation structure(s) (DDS) obtained from atomistic simulations. Our new DDS-DFXM model integrates a non-singular formulation for calculating the local strain from the DDS and an efficient geometrical optics algorithm for computing the DFXM image from the strain field. We apply the model to complex DDS obtained from a large-scale mol­ecular dynamics simulation of compressive loading on single-crystal silicon. Simulated DFXM images exhibit prominent contrast for dislocation features between the multiple slip systems, demonstrating the potential of DFXM to resolve features from dislocation multiplication. In conclusion, the integrated DDS-DFXM model provides a toolbox for DFXM experimental design and image interpretation in the context of bulk crystal plasticity for a range of measurements across shock plasticity and the broader materials science community.

X-ray imaging

Investigation of the Anisotropy of Y-Ba-Cu-O Thin Films With Photoemission Electron Microscopy

Understanding the anisotropy in the electrical properties of YBa2Cu3O7-δ (YBCO) is important for understanding the fundamental mechanism of superconductivity in unconventional superconductors. Additionally it is also essential for achieving uniform and controllable critical currents and resistances in YBCO Josephson junctions. Here, this study correlates work function measurements of different intrinsic regions on YBCO thin films, obtained through PhotoEmission Electron Microscopy (PEEM), with in plane tunneling data and helium ion imaging. YBCO thin films, 40 nm in thickness, were selectively irradiated with 300 keV helium using a Pelletron to investigate the effects of irradiation compared to unirradiated regions. Post-irradiation PEEM images revealed distinct contrasts between irradiated and non-irradiated regions, suggesting a metal-to-insulator transition. In non-irradiated areas, a domain pattern was detected, showing a 25 meV difference in work function, attributed to CuO and BaO rich surface regions. A similar domain structure was observed using high-resolution helium ion imaging; however, the helium ion beam can damage the YBCO, making PEEM a valuable non-destructive alternative. This work highlights the correlation between PEEM measurements and in-plane tunneling properties of YBCO, providing insights into material orientation and its impact on Josephson junction performance. Furthermore, it offers a non-destructive approach to understanding the anisotropy of cuprate materials, its superconducting properties, and the factors affecting Josephson junction performance.

Qu, Rochelle Y. [Univ. of California, Riverside, C

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE

Pre-training Vision Models for the Classification of Alerts from Wide-field Time-domain Surveys

Modern wide-field time-domain surveys facilitate the study of transient, variable and moving phenomena by conducting image differencing and relaying alerts to their communities. Machine learning tools have been used on data from these surveys and their precursors for more than a decade, and convolutional neural networks (CNNs), which make predictions directly from input images, saw particularly broad adoption through the 2010s. Since then, continually rapid advances in computer vision have transformed the standard practices around using such models. It is now commonplace to use standardized architectures pre-trained on large corpora of everyday images (e.g., ImageNet). In contrast, time-domain astronomy studies still typically design custom CNN architectures and train them from scratch. Here, we explore the effects of adopting various pre-training regimens and standardized model architectures on the performance of alert classification. We find that the resulting models match or outperform a custom, specialized CNN like what is typically used for filtering alerts. Moreover, our results show that pre-training on galaxy images from Galaxy Zoo tends to yield better performance than pre-training on ImageNet or training from scratch. We observe that the design of standardized architectures are much better optimized than the custom CNN baseline, requiring significantly less time and memory for inference despite having more trainable parameters. On the eve of the Legacy Survey of Space and Time and other image-differencing surveys, these findings advocate for a paradigm shift in the creation of vision models for alerts, demonstrating that greater performance and efficiency, in time and in data, can be achieved by adopting the latest practices from the computer vision field.

79 ASTRONOMY AND ASTROPHYSICS

Magnetic force microscopy revealing long-range room temperature stable molecule bridge-induced magnetic ordering on magnetic tunnel junction (MTJ) pillars

Magnetic tunnel junctions (MTJs) can integrate novel single molecular device elements to overcome long-standing fabrication challenges, thus unlocking their novel potential. This study employs magnetic force microscopy (MFM) to demonstrate that organometallic molecules, when placed between two ferromagnetic electrodes along cross-junction shaped MTJ edges, dramatically altered the magnetic properties of the electrodes, affecting areas several hundred microns in size around the molecular junction vicinity at room temperature. These findings are supported by magnetic resonance and magnetometer studies on ∼7000 MTJ pillars. MFM on the pillar sample showed an almost complete disappearance of the magnetic contrast. The spatial magnetic image suggests that molecular channels significantly impacted the spin density of states in the ferromagnetic electrodes. This advancement in MTJ-based molecular devices paves the way for a new generation of commercially viable logic and memory devices controlled by molecular quantum states at near-room temperatures.

Tyagi, Pawan (ORCID:0000000275411344)

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION

Specifications of Legacy U(Pu)Zr Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Program has supported the creation of several databases with information describing the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data is one of the most important types of PIE data being collected, organized and stored in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three main sets of metallography data. The first set is the metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins measured in the Hot Fuel Examination Facility (HFEF); the second set is the metallography data from EBR-II irradiated fuel pins measured in the Alpha-Gamma Hot Cell Facility (AGHCF); the third set is the metallography data from transient tested fuel pins (the transients tests include the out-of-pile tests and TREAT tests) measured in AGHCF. Since both the second and third sets of data were measured in AGHCF, they are governed by the same specification. The metallography data in the databases are digital images scanned from either positive or negative photos. The quality of the images, including their resolution and contrast, relies on the preserved quality of the pictures and the scanning conditions. To analyze the microstructure of a fuel pin, a series of preparatory steps must be undertaken. These include sectioning, epoxy mounting, mechanical grinding and polishing, and often etching. The resulting samples were then transferred to a secondary hot cell, or glovebox (depending the strength of radiation field) for microscopy examination. The specifications provided herein focus on the metallography examinations. The sample grinding, polishing and etching processes are also discussed. The procedures involving sectioning and epoxy mounting are out of the scope of the current specification; details can be found in the corresponding operation manuals. If more data are collected and added to the ART Fast Reactor Databases, this specification will be updated to accommodate the additional data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE