Combined Effects of Multi-Pulse Transient Plasma Ignition and Intake Heating on Lean Limits of Well-mixed E85 SI Engine Operation.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
A literature survey was conducted to determine the relation between aircraft ignition sources and inflammables. Available literature applicable to the problem of aircraft fire hazards is analyzed and discussed. Data pertaining to the effect of many variables on ignition temperatures, minimum ignition pressures, minimum spark-ignition energies of inflammables, quenching distances of electrode configurations, and size of openings through which flame will not propagate are presented and discussed. Ignition temperatures and limits of inflammability of gasoline in air in different test environments, and the minimum ignition pressures and minimum size of opening for flame propagation in gasoline-air mixtures are included; inerting of gasoline-air mixtures is discussed.
Ignition temperature and limiting fuel concentrations of mixtures of coal gas, methane, and air by hot gas jet ignition
After a decade of trying, the grand challenge problem of achieving hot spot ignition on NIF has not been achieved using indirect-drive of a high-convergence single shell capsule inside a hohlraum. Here, the alternate concept of obtaining volume-like ignition of liquid DT fuel via multi-shell implosion using laser polar direct drive (PDD) on NIF was assessed through theoretical analysis, computer simulation, fabrication development and implosion experiments on both the Laboratory for Laser Energetics’ (LLE) Omega laser and the National Ignition Facility (NIF). This research has shown that multi-shell ignition has merit and should be further advanced by the National ICF Program to determine its ultimate limitations for achieving ignition on NIF.
The Electric Particulate Suspension is a fire safety ignition test system being developed at Iowa State University with NASA support for evaluating combustion properties of powders, powder-gas mixtures, and pure gases in microgravity and gravitational atmospheres (quenching distance, ignition energy, flammability limits). A separate application is the use of EPS technology to control heat transfer in vacuum and space environment enclosures. In combustion testing, ignitable powders (aluminum, magnesium) are introduced in the EPS test cell and ignited by spark, while the addition of inert particles act as quenching media. As a combustion research tool, the EPS method has potential as a benchmark design for quenching powder flames that would provide NASA with a new fire safety standard for powder ignition testing. The EPS method also supports combustion modeling by providing accurate measurement of flame-quenching distance as an important parameter in laminar flame theory since it is closely related to characteristic flame thickness and flame structure. In heat transfer applications, inert powder suspensions (copper, steel) driven by electric fields regulate heat flow between adjacent surfaces enclosures both in vacuum (or gas) and microgravity. This simple E-field control can be particularly useful in space environments where physical separation is a requirement between heat exchange surfaces.
We irradiated Al/Pt nanolaminates with a bilayer thickness (tb, width of an Al/Pt pair-layer) of 164 nm with single laser pulses with durations of 10 ms and 0.5 ms at 189 W/cm 2 and 1189 W/cm 2 , respectively. The time to ignition was measured for each pulse, and shorter ignition times were observed for the higher power/shorter pulse width. While the shorter pulse shows uniform brightness, videographic images of the irradiated area shortly after ignition show a non-uniform radial brightness for the longer pulse. A diffusion-limited single step reaction mechanism was implemented in a finite element package to model the progress from reactants to products at both pulse widths. Finally, the model captures well both the observed ignition delay and qualitative observations regarding the non-uniform radial temperature.
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalyst are presented.
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalysts are presented.
Explore the source record for details and available documents.
Ignition of rich hydrogen-oxygen mixture in a monolithic catalytic reactor is studied using a transient combustion model. The model assumes a quasi-steady gas phase and a thermally-thin substrate. The ignition time lag is due to the thermal inertia of the substrate. One-step global chemical reaction is assumed both on the surface and in the gas phase. An effectiveness factor is introduced to account for the transition from a kinetically-limited catalytic surface reaction to a diffusion-limit one during ignition. Results presented include a catalytic ignition boundary, ignition delay time and the transient response in the catalytic bed.
Pivotal areas for needed combustion observations (available through space shuttle experimentation) include: (1) single- and two-phase premixed flame propagation and extinction limits; (2) noncoherent flame propagation and extinction; (3) autoignition of premixed single-phase and two-phase combustible reactants; (4) upper pressure limit combustion phenomena and ignition, propagation, and extinction processes in the neighborhood of such limits; (5) oscillatory combustion associated with the hydrocarbon-oxygen and with the carbon monoxide-oxygen systems; (6) two-phase flame spread and extinction involving lage liquid-gas or solid-gas interfaces; (7) radiative ignition of solids and liquids; (8) pool burning; (9) smoldering of solid combustibles and the associated transition to flaming or extinction; (10) laminar gas jet combustion; and (11) transient responses of combustible systems to time variation in gravitational field strengths. A number of these may be impacted by undesirably high g-jitter effects.
EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen. Shell 405 granular catalyst and a unique monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant inlet temperature, and back pressure were varied parametrically in testing to determine the operational limits of a catalytic igniter. The test results showed that the gaseous hydrogen/oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. The results of the experimental program and the established operational limits for a catalytic igniter using both the granular and monolithic catalysts are presented. The capabilities of a facility constructed to conduct the igniter testing and the advantages of a catalytic igniter over other ignition systems for gaseous hydrogen and oxygen are also discussed.
The Electric Particulate Suspension (EPS) is a combustion ignition system being developed at Iowa State University for evaluating quenching effects of powders in microgravity (quenching distance, ignition energy, flammability limits). Because of the high cloud uniformity possible and its simplicity, the EPS method has potential for "benchmark" design of quenching flames that would provide NASA and the scientific community with a new fire standard. Microgravity is expected to increase suspension uniformity even further and extend combustion testing to higher concentrations (rich fuel limit) than is possible at normal gravity. Two new combustion parameters are being investigated with this new method: (1) the particle velocity distribution and (2) particle-oxidant slip velocity. Both walls and (inert) particles can be tested as quenching media. The EPS method supports combustion modeling by providing accurate measurement of flame-quenching distance as a parameter in laminar flame theory as it closely relates to characteristic flame thickness and flame structure. Because of its design simplicity, EPS is suitable for testing on the International Space Station (ISS). Laser scans showing stratification effects at 1-g have been studied for different materials, aluminum, glass, and copper. PTV/PIV and a leak hole sampling rig give particle velocity distribution with particle slip velocity evaluated using LDA. Sample quenching and ignition energy curves are given for aluminum powder. Testing is planned for the KC-135 and NASA s two second drop tower. Only 1-g ground-based data have been reported to date.
We study the Kelvin–Helmholtz instability (KHI) for the general case of a compressible, nonhomogeneous, magnetized plasma flow. The study is limited to a vortex sheet interface with an imposed parallel magnetic field. We introduce a new formalism based on a convective Mach number M c , a convective Alfvénic Mach number M Ac , and a total convective Mach number that combines the two. We derive an analytic expression of the KHI growth rate for a homogeneous flow (i.e., zero Atwood number, A=0) that converges toward both the expression for unmagnetized compressible flow and Chandrasekhar's expression for magnetized incompressible flow. Otherwise, the dispersion relation is solved numerically and allows deriving general stability diagrams of magnetized KHI for the triplet (A, M c , β −plasma) parameters. We show these parameters uniquely define all configurations for a parallel magnetic field. We also construct diagrams with respect to the convective Alfvénic Mach number, the β − plasma parameter, or the magnetic field showing which magnetic field strength is required for stabilizing a given shear flow. The theoretical growth rates are compared with 18 simulations made with the GAMERA code, currently used for 3D magnetospheric simulations. Finally, we apply our results to the analysis of a past KHI experiment performed at the OMEGA laser facility, showing linear theory succeeds to provide accurate estimates of the growth rate at early times. We further discuss how our results can inform future experiments in the high-Mach magnetized regime at the National Ignition Facility. Possible limitations of the study due to resistive, mixing, or turbulence effects are discussed.
Laser-direct drive (LDD), along with laser indirect (X-ray) drive (LID) and magnetic drive with pulsed power, is one of the three viable inertial confinement fusion approaches to achieving fusion ignition and gain in the laboratory. The LDD programme is primarily being executed at both the Omega Laser Facility at the Laboratory for Laser Energetics and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. LDD research at Omega includes cryogenic implosions, fundamental physics including material properties, hydrodynamics and laser–plasma interaction physics. LDD research on the NIF is focused on energy coupling and laser–plasma interactions physics at ignition-scale plasmas. Limited implosions on the NIF in the ‘polar-drive’ configuration, where the irradiation geometry is configured for LID, are also a feature of LDD research. The ability to conduct research over a large range of energy, power and scale size using both Omega and the NIF is a major positive aspect of LDD research that reduces the risk in scaling from OMEGA to megajoule-class lasers. Furthermore, the paper will summarize the present status of LDD research and plans for the future with the goal of ultimately achieving a burning plasma in the laboratory.