At least 91 records · Page 5

Adherens junction-associated pores mediate the intercellular transport of endosomes and cytoplasmic proteins

Highlights: • We demonstrated the presence of AJ-associated pores with MTs traversing through the pores. • Live imaging allows direct visualization of vesicles being transported through the AJ-associated pores. • The dimerized vesicle-kinesin complexes move across AJs into the neighboring cell. • Most epidermal cells form dorsoventral-oriented two-cell syncytia. Intercellular endosomes (IEs) are endocytosed vesicles shuttled through the adherens junctions (AJs) between two neighboring epidermal cells during Drosophila dorsal closure. The cell-to-cell transport of IEs requires DE-cadherin (DE-cad), microtubules (MTs) and kinesin. However, the mechanisms by which IEs can be transported through the AJs are unknown. Here, we demonstrate the presence of AJ-associated pores with MTs traversing through the pores. Live imaging allows direct visualization of IEs being transported through the AJ-associated pores. By using an optogenetic dimerization system, we observe that the dimerized IE-kinesin complexes move across AJs into the neighboring cell. The AJ-associated pores also allow intercellular movement of soluble proteins. Importantly, most epidermal cells form dorsoventral-oriented two-cell syncytia. Together, we present a model in which an AJ-associated pore mediates the intercellular transport of IEs and proteins between two cells in direct contact.

60 APPLIED LIFE SCIENCES↗

The effect of microhydration on ionization energies of thymine

A combined theoretical and experimental study of the effect of microhydration on ionization energies (IEs) of thymine is presented. The experimental IEs are derived from photoionization efficiency curves recorded using tunable synchrotron VUV radiation. The onsets of the PIE curves are 8.85+-0.05, 8.60+-0.05, 8.55+-0.05, and 8.40+-0.05 eV for thymine, thymine mono-, di-, and tri-hydrates, respectively. The computed (EOM-IP-CCSD/cc-pVTZ) AIEs are 8.90, 8.51, 8.52, and 8.35 eV for thymine and the lowest isomers of thymine mono-, di-, and tri-hydrates. Due to large structural relaxation, the Franck-Condon factors for the 0<-- 0 transitions are very small shifting the apparent PIE onsets to higher energies. Microsolvation strongly affects IEs of thymine -- addition of each water molecule reduces the first vertical IE by 0.10-0.15 eV. The adiabatic IE decreases even more (up to 0.4 eV). The magnitude of the effect varies for different ionized states and for different isomers. For the ionized states that are localized on thymine the dominant contribution to the IE reduction is the electrostatic interaction between the delocalized positive charge on thymine and the dipole moment of the water molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The stellar mass Fundamental Plane: the virial relation and a very thin plane for slow rotators

ABSTRACT Early-type galaxies – slow and fast rotating ellipticals (E-SRs and E-FRs) and S0s/lenticulars – define a Fundamental Plane (FP) in the space of half-light radius Re, enclosed surface brightness Ie, and velocity dispersion σe. Since Ie and σe are distance-independent measurements, the thickness of the FP is often expressed in terms of the accuracy with which Ie and σe can be used to estimate sizes Re. We show that: (1) The thickness of the FP depends strongly on morphology. If the sample only includes E-SRs, then the observed scatter in Re is $\sim 16{{\ \rm per\ cent}}$, of which only $\sim 9{{\ \rm per\ cent}}$ is intrinsic. Removing galaxies with M* < 1011 M⊙ further reduces the observed scatter to $\sim 13{{\ \rm per\ cent}}$ ($\sim 4{{\ \rm per\ cent}}$ intrinsic). The observed scatter increases to $\sim 25{{\ \rm per\ cent}}$ usually quoted in the literature if E-FRs and S0s are added. If the FP is defined using the eigenvectors of the covariance matrix of the observables, then the E-SRs again define an exceptionally thin FP, with intrinsic scatter of only 5 per cent orthogonal to the plane. (2) The structure within the FP is most easily understood as arising from the fact that Ie and σe are nearly independent, whereas the Re−Ie and Re−σe correlations are nearly equal and opposite. (3) If the coefficients of the FP differ from those associated with the virial theorem the plane is said to be ‘tilted’. If we multiply Ie by the global stellar mass-to-light ratio M*/L and we account for non-homology across the population by using Sérsic photometry, then the resulting stellar mass FP is less tilted. Accounting self-consistently for M*/L gradients will change the tilt. The tilt we currently see suggests that the efficiency of turning baryons into stars increases and/or the dark matter fraction decreases as stellar surface brightness increases.

Bernardi, M.↗

Beyond Price-Taker: Multiscale Optimization of Wind and Battery Integrated Energy Systems

Integrating renewable energy into the electric grid is challenging due to the intermittency and variability of wind and other non-dispatchable resources. Integrated energy systems (IESs) combine multiple energy technologies (e.g., fossil, nuclear, renewables, storage) to reduce costs and improve flexibility and reliability. However, standard techno-economic analysis (TEA) methods often overestimate the benefits of IESs because they fail to account for energy market adjustments. This paper systematically studies the limitations of the prevailing price-taker assumption for TEA and optimization of hybrid energy systems. As an illustrative case study, we retrofit an existing wind farm in the RTS-GMLC test system (which loosely mimics the Southwest U.S.) with battery energy storage to form an IES. We show that the standard price-taker model overestimates the electricity revenue and the net present value (NPV) of the IES up to 178% and 30.4%, respectively, compared to our more rigorous multiscale optimization. These differences arise because introducing storage creates a more flexible resource that impacts the larger wholesale electricity market. Moreover, this work highlights the impact of the IES has on the market via various strategic bidding, and underscores the importance of moving beyond price-taker for optimal storage sizing and TEA of IESs. We conclude by discussing opportunities to generalize the proposed framework to other IESs, and highlight emerging research questions regarding the complex interactions between IESs and markets.

25 ENERGY STORAGE↗

Direct Nonlinear Approximation for Security Region Boundary of Integrated Energy Systems: A Polynomial Chaos Expansion Solution

The strong interdependence of electricity, gas, and heating systems can facilitate fault propagation within integrated energy systems (IESs), posing significant challenges to secure operation. This paper proposes a polynomial chaos expansion (PCE)-based approximation method to accurately characterize the IES security region boundary (IES–SRB). By integrating the Karush-Kuhn-Tucker conditions with PCE theory, the IES-SRB approximation problem is reformulated as a set of nonlinear equations concerning the approximation coefficients. Using the Galerkin projection method, these equations are further transformed into a system of projection equations that govern the polynomial approximation coefficients in the IES-SRB approximation. To reduce computational complexity while maintaining high approximation accuracy, a piecewise polynomial approximation method is proposed. Numerical studies on the E39-G20-H6 and E118-G96-H52 IES test systems demonstrate that the proposed method can accurately and effectively construct IES security regions.

Wu, Chenghao [Northeast Electric Power University]↗

Role of the blocking capacitor in control of ion energy distributions in pulsed capacitively coupled plasmas sustained in Ar/CF{sub 4}/O{sub 2}

In plasma etching for microelectronics fabrication, the quality of the process is in large part determined by the ability to control the ion energy distribution (IED) onto the wafer. To achieve this control, dual frequency capacitively coupled plasmas (DF-CCPs) have been developed with the goal of separately controlling the magnitude of the fluxes of ions and radicals with the high frequency (HF) and the shape of the IED with the low frequency (LF). In steady state operation, plasma properties are determined by a real time balance between electron sources and losses. As such, for a given geometry, pressure, and frequency of operation, the latitude for controlling the IED may be limited. Pulsed power is one technique being investigated to provide additional degrees of freedom to control the IED. In one configuration of a DF-CCP, the HF power is applied to the upper electrode and LF power is applied to the lower electrode which is serially connected to a blocking capacitor (BC) which generates a self dc-bias. In the steady state, the value of the dc-bias is, in fact, constant. During pulsed operation, however, there may be time modulation of the dc-bias which provides an additional means to control the IED. In this paper, IEDs to the wafer in pulsed DF-CCPs sustained in Ar/CF{sub 4}/O{sub 2} are discussed with results from a two-dimensional plasma hydrodynamics model. The IED can be manipulated depending on whether the LF or HF power is pulsed. The dynamic range of the control can be tuned by the dc-bias generated on the substrate, whose time variation depends on the size of the BC during pulsed operation. It was found that high energy ions can be preferentially produced when pulsing the HF power and low energy ions are preferentially produced when pulsing the LF power. A smaller BC value which allows the bias to follow the change in charged particle fluxes produces a larger dynamic range with which to control IEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗

Comparative evaluation and selection of heat exchangers using multicriteria decision-making

Here, this study presents a well-structured method for comparing and selecting Heat Exchanger (HE) technologies for Integrated Energy Systems (IES). The decision to select a HE for a particular IES configuration can vary greatly depending not only on engineering requirements but also on customer’s specific demand. In other words, the HE selection for IES requires a multicriteria decision-making approach, taking into account diverse technical, economic, and safety aspects, as well as the relative priorities considered by energy users. This study employs a HE evaluation approach combining multicriteria decision-making techniques widely used in various industries: quality function deployment (QFD) and analytic hierarchy process (AHP) techniques. Of particular interest is the use of the proposed method to select a high-temperature HEs that couples advanced nuclear reactors and industrial processes. To build a practical basis for comparing HEs within the proposed framework, efforts were made to identify the various HEs requirements for IES purposes. In addition, leveraging the insights obtained from the literature review and the market survey of commercial HE suppliers, a knowledge base was built to facilitate the comparison of each requirement across various HE designs. Also, evaluation metrics were identified for HE requirements with robust rational to enhance the quality of decisions made throughout the proposed evaluation process. The evaluation procedure and knowledge base described in this study can provide a useful basis for those interested in screening the appropriate HE designs for various IES scenarios.

Analytic Hierarchy Process (AHP)↗

Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis

Background: The current diagnosis of infective endocarditis (IE) is based on the modified Duke criteria, which has approximately 80% sensitivity for the diagnosis of native valve endocarditis (NVE), with lower sensitivity for the diagnosis of prosthetic valve endocarditis (PVE) and culture-negative endocarditis. There is preliminary evidence that {sup 18}F-FDG PET/CT is an adjunctive diagnostic test with high accuracy reported in small studies to date. We therefore performed a meta-analysis of studies evaluating the use of PET/CT in the diagnosis of IE to establish a more precise estimate of accuracy. Methods: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov were searched from January 1990 to April 2017 for studies evaluating the accuracy of PET/CT for the evaluation of possible IE. Results: We identified 13 studies involving 537 patients that were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of IE was 76.8% (95% CI 71.8–81.4%; Q = 39.9, P < 0.01; I{sup 2} = 69.9%) and the pooled specificity was 77.9% (95% CI 71.9–83.2%; Q = 44.42, P < 0.01; I{sup 2} = 73.0%). Diagnostic accuracy was improved for PVE with sensitivity of 80.5% (95% CI 74.1–86.0%; Q = 25.5, P < 0.01; I{sup 2} = 72.5%) and specificity of 73.1% (95% CI 63.8–81.2%; Q = 32.1, P < 0.01; I{sup 2} = 78.2%). Additional extracardiac foci of infection were found on 17% of patients on whole body PET/CT. Conclusion: PET/CT is a useful adjunctive diagnostic tool in the evaluation of diagnostically challenging cases of IE, particularly in prosthetic valve endocarditis. It also has the potential to detect clinically relevant extracardiac foci of infection, malignancy, and other sources of inflammation leading to more appropriate treatment regimens and surgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water Exchange Rate Constant as a Biomarker of Treatment Efficacy in Patients With Brain Metastases Undergoing Stereotactic Radiosurgery

Purpose: This study was designed to evaluate whether changes in metastatic brain tumors after stereotactic radiosurgery (SRS) can be seen with quantitative MRI early after treatment. Methods and Materials: Using contrast-enhanced MRI, a 3-water-compartment tissue model consisting of intracellular (I), extracellular-extravascular (E), and vascular (V) compartments was used to assess the intra–extracellular water exchange rate constant (k{sub IE}), efflux rate constant (k{sub ep}), and water compartment volume fractions (M{sub 0,I}, M{sub 0,E}, M{sub 0,V}). In this prospective study, 19 patients were MRI-scanned before treatment and 1 week and 1 month after SRS. The change in model parameters between the pretreatment and 1-week posttreatment scans was correlated to the change in tumor volume between pretreatment and 1-month posttreatment scans. Results: At 1 week k{sub IE} differentiated (P<.001) tumors that had partial response from tumors with stable and progressive disease, and a high correlation (R=−0.76, P<.001) was observed between early changes in the k{sub IE} and tumor volume change 1 month after treatment. Other model parameters had lower correlation (M{sub 0,E}) or no correlation (k{sub ep}, M{sub 0,V}). Conclusions: This is the first study that measured k{sub IE} early after SRS, and it found that early changes in k{sub IE} (1 week after treatment) highly correlated with long-term tumor response and could predict the extent of tumor shrinkage at 1 month after SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing Reactivity of Gold Atoms with Acetylene and Ethylene with VUV Photoionization Mass Spectrometry and Ab Initio Studies

Reaction of gold atoms with acetylene and ethylene in a laser ablation source produces a number of gold-containing species. Their photoionization efficiency (PIE) curves are measured using tunable vacuum ultraviolet (VUV) radiation at the Advanced Light Source. Their structures are assigned by comparing the experimental ionization energies and PIE curves to those of potential isomers calculated at the CAM-B3LYP/aug-cc-pVTZ level. For smaller molecules, the contribution of ionization to excited electronic states of the cation is also included using photoionization cross sections calculated using ePolyScat . Reaction with acetylene produces adducts Au(C 2 H 2 ) and Au(C 2 H 2 ) 2 , as well as HAu(C 4 H 2 ). Reaction with ethylene leads to adducts Au(C 2 H 4 ), Au(C 2 H 4 ) 2 , an adduct with a gold dimer, Au 2 (C 2 H 4 ), as well as the gold hydrides AuH, HAu(C 2 H 4 ), and HAu(C 4 H 4 ). [Au,C4,H7] is also observed, and it likely corresponds to a gold alkyl, H 2 C$=$C(H)-Au(C 2 H 4 ). Reactions leading to production of odd-hydrogen species are endothermic and are likely due to translationally or electronically excited gold atoms. These measurements provide the first directly measured ionization energy for gold hydride, IE(AuH) = 10.25 ± 0.05 eV. Combining this value with the dissociation energy of AuH + gives a dissociation energy D 0 (AuH) = 3.15 ± 0.12 eV. Several other ionization energies are measured: IE(Au 2 (C 2 H 4 )) = 8.42 ± 0.05 eV, IE(HAu(C 2 H 4 )) = 9.35 ± 0.05 eV, IE(HAu(C 4 H 2 )) = 8.8 ± 0.1 eV, and IE(HAu(C 4 H 4 )) = 8.8 ± 0.1 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and control of nuclear–renewable integrated energy systems: Dynamic system model for green electricity and hydrogen production

The need for decarbonization and diversification of energy resources has led to the development of integrated energy systems (IESs), where multiple resources supply more than one energy sector. Here, one such IES with small modular nuclear reactors and renewables (wind and solar) as generating resources, catering to the demand of the electric grid while producing hydrogen for industries, is modeled in this paper. The physics-based component models are represented using the Modelica language and interconnected to form the IES. The control and coordination of the overall system are ensured by designing a suitable control architecture composed of individual subsystem-level controls and supervisory control. The dynamic performance and the load-following capability of the IES are evaluated, while satisfying the safe operational limits of the components. Different configurations and modes of IES operation are considered, where the adaptability of the control system in the presence of varying demands and renewable generations is validated. The simulation results indicate that hydrogen as a flexible load facilitates the supply of varying grid demand. Additionally, the renewables are also accommodated into the IES owing to the flexibility of the balance of plant associated with the nuclear reactors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review and Modeling of Integrated Energy Systems with Nuclear Reactor Coupled Desalination and District Heating

Detailed reviews of a past advanced nuclear reactor based integrated energy system, as well as other nuclear reactor and fossil fuel based integrated energy systems have been performed for this work. Review of the utilization of heat from nuclear reactors for various applications and cogeneration has been done. The heat can be utilized by extraction of the steam from the turbine while the steam is still at a desired temperature. While use of nuclear process heat for district heating in countries like Finland, France, China, Poland, and elsewhere is discussed, more focus of the review has been given on nuclear desalination processes. Integrated energy systems (IES) where distinct types of reactors like PWR, BWR, sodium cooled fast reactor, heavy water reactor and other advanced reactors are coupled with various nuclear desalination processes like multi-effect distillation (MED), multi-stage flashing (MSF) and reverse osmosis (RO) methods have been discussed. The nuclear desalination plant at Aktau has been discussed in more detail due to its decades of successful operation. The IES of the Aktau plant coupled with 5-effect MED desalination plant has been taken as a reference for modeling the Open Modelica (OM) based IES of this work. Here, the OM IES model shows good agreement with the MED plant output of Aktau and can be extended for future applications of IES.

42 ENGINEERING↗

Hybrid Simulation Framework

HYBRID is a modeling toolset to assess the economic viability of Nuclear-Renewable Integrated Energy Systems (N-R IES). The frameworks enabling this toolset are INL’s RAVEN, its CashFlow plugin and the Modelica language. The toolset includes sample RAVEN workflows performing economic assessments. These workflows consist of: generation of stochastic time series and application of probabilistic analysis and optimization algorithms (RAVEN); a library of Modelica models representing the physical behavior of N-R IES; and the CashFlow plugin mapping physical performance to economic performance. The toolset allows assembling existing and new models such as nuclear reactors, renewable energy sources, energy storage, gas turbines, industrial processes, etc. into an N-R IES. The toolset workflows evaluate the dynamics of the N-R IES responding to stochastic conditions (electricity demand, price, etc.) and optimize the dispatch economics as well as N-R IES capacity planning.

Epiney, Aaron↗

Dependencies of Four Mechanisms of Secondary Ice Production on Cloud-Top Temperature in a Continental Convective Storm

Various mechanisms of secondary ice production (SIP) cause multiplication of numbers of ice particle, after the onset of primary ice. A measure of SIP is the ice enhancement ratio (“IE ratio”) defined here as the ratio between number concentrations of total ice (excluding homogeneously nucleated ice) and active ice-nucleating particles (INPs). A convective line observed on 11 May 2011 over the Southern Great Plains in the Mesoscale Continental Convective Cloud Experiment (MC3E) campaign was simulated with the “Aerosol–Cloud” (AC) model. AC is validated against coincident MC3E observations by aircraft, ground-based instruments, and satellite. Four SIP mechanisms are represented in AC: the Hallett–Mossop (HM) process of rime splintering, and fragmentation during ice–ice collisions, raindrop freezing, and sublimation. The vertical profile of the IE ratio, averaged over the entire simulation, is almost uniform (10 2 to 10 3 ) because fragmentation in ice–ice collisions dominates at long time scales, driving the ice concentration toward a theoretical maximum. The IE ratio increases with both the updraft (HM process, fragmentation during raindrop freezing, and ice–ice collisions) and downdraft speed (fragmentation during ice–ice collisions and sublimation). As reported historically in aircraft sampling, IE ratios were predicted to peak near 10 3 for cloud-top temperatures close to the −12°C level, mostly due to the HM process in typically young clouds with their age less than 15 min. Here, at higher altitudes with temperatures of −20° to −30°C, the predicted IE ratios were smaller, ranging from 10 to 10 2 , and mainly resulted from fragmentation in ice–ice collisions.

Aerosols↗

Crystalline Silicotitanate ion exchange media long-term storage evaluation

Crystalline Silicotitanate a (CST) ion exchange media is produced in an engineered form, known as IONSIV™ IE-911. This material has been tested extensively for use in removing 137 Cs from Savannah River Site (SRS) and Hanford site tank waste. This inorganic material is highly selective for removing cesium ions, even in the presence of high concentrations of sodium and potassium ions and is tolerant of the harsh conditions of the varying tank chemistries. A batch of caustic washed IE-911 that had been produced by the supplier and received at SRS in 2001 was tested to verify that it was still in good condition after the extended storage. This testing involved standard batch contacts to measure the removal of Cs from simulated tank waste. This report describes the results of testing performed to verify that the IE-911 matches the performance of previous batches of this media. To confirm that the performance of IE-911 is similar to previous batches and that no degradation had occurred during storage, batch contact testing was performed using SRNL’s standard methodology using a non-radioactive SRS Average Waste Simulant composition utilized in previous studies. Batch contact kinetics testing was also conducted to determine cesium loading on this batch versus time. The cesium equilibrium loading isotherm in SRS simulant at 23°C was compared to ZAM isotherm model predictions and previous test results with IE-911 media. The measured and predicted distribution coefficients and cesium loading (“Q”) are shown in Table ES-1. The physical properties of the material were also determined, including density, moisture content, and particle size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal Project CST Simulant Cesium Batch Contact Kinetics Test Results and Column Performance Predictions

To evaluate the cesium removal capabilities of the caustic-washed R9120-B version of crystalline silicotitanate (CST) ion exchange media from Savannah River Site (SRS) waste during Tank Closure Cesium Removal (TCCR) column processing, batch contact kinetics tests were performed at 23 °C in SRS Average simulant. Cesium loading kinetics data was also collected (in current and previous testing; King, et al., 2018a) using the same simulant for an older CST sample (IE- 911) which was caustic-washed by the vendor many years ago and was recently retrieved from drums stored at SRS. (Note that R9120-B and IE-911 are believed to be identical materials, after the R9120-B was caustic washed by SRNL, and differ only by particle size and manufacturing date, and thus can be considered different batches). Although cesium loading kinetics testing can be conducted more rigorously using dynamic column tests, the batch contact method requires less simulant and considerably less experimental effort. Average percent removal data for batch contact samples for the two CST batches are provided in Table ES-1. Faster cesium uptake was observed with IE-911, although the loading rates for the two media batches were similar. After 5.5 hours of CST contact, 81% cesium removal was observed with R9120-B versus 86% removal with IE-911. Although these differences are small, the trend is consistent across the timed results, with the larger bead material always loading slower. These seemingly small differences in percent removal are believed to have a large impact on the column performance. Cesium loading curves for the two CST batches are provided in Figure ES-1 below. Faster cesium loading with IE-911 CST is presumed to be associated with the smaller average particle diameter (408 μm mean volume diameter) versus R9120-B (572 μm diameter). Cesium loading kinetic data was needed to conduct column performance comparisons (i.e., model predictions) for the two CST batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗