Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IEEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

IEEE SusTech 2025 Presentation

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6\% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

42 - ENGINEERING↗

IEEE PES GM Poster - Cyber-Informed Engineering Approach to Mitigating BESS Supply Chain Concerns

Battery energy storage systems (BESS) are increasingly important to meet the needs of grid resilience and reliability. BESS provide critical grid services, maintaining stability of the grid with increased variable conditions. However, there are significant geopolitical and security concerns regarding their operation in critical infrastructure, due to lack of a domestic supply chain and prevalence of foreign entity of concern (FEOC) components in BESS and associated inverter-based resources. The supply chain challenge is dually exacerbated by a lack of alternative suppliers who can meet the economic targets for energy delivery and a potentially adversarial supply chain. Solutions are needed to secure components, addressing mixed layers of risk and engineering controls. This paper presents a specific application of Cyber-Informed Engineering (CIE) principles for BESS and recommends an alternative strategy to blocking the supply chain, ensuring that grid modernization targets can be met despite lack of a validated or secure supply chain. This study focuses on the United State (U.S.) use case, but the process can be applied globally to address supply chain security challenges. CIE practices represent the next step in functional assurance and risk mitigation, ensuring optimal resource allocation and enhancing security measures to safeguard the future of energy in the U.S. and beyond.

25 - ENERGY STORAGE↗

IEEE PAINE

Explore the source record for details and available documents.

Pattengale, Nicholas Dylan [Sandia National Labora↗

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Learning model combining convolutional deep neural network with a self-attention mechanism for AC optimal power flow

Alternating current optimal power flow (OPF) analysis is critical for efficient and reliable operation of power systems. For large systems or repetitive computations, the traditional methods such as the direct and gradient methods, or non-traditional methods, such as the genetic algorithm and simulating annealing, are time-consuming and unsuitable for real-time computing. The work in this paper proposes a novel framework to obtain the optimal solution of power flow in real-time using a combination of convolutional neural networks and a self-attention mechanism. All parameters of the power networks are rearranged in an image-like shape of a multi-channel image where each channel is a two-dimensional matrix. The proposed approach is adaptive with every input size of power systems as well as frequent variations of network topologies without intervention to the framework core. The encompassment of all power system contexts in which all parameters of internal elements, generation costs, and topology information are included, contributes to the higher accuracy of inference compared to other current machine-learning-based OPF-solving methods. Besides, the proposed framework established on ubiquitous platforms is effortlessly integrated into current infrastructures of power systems, and the great efficiency along with the computation speed may serve as a critical point for practical implications, such as enabling faster decision-making during real-time operations, predicting system contingencies, and remedial actions based on an offline pre-trained model. Furthermore, this supervised learning process is applied to the dataset of four case studies of meshed power systems: the IEEE 5-bus system (IEEE-5), the IEEE 30-bus system (IEEE-30), the IEEE 39-bus system (IEEE-39), and the IEEE 57-bus system (IEEE-57) to prove the efficacy of the proposed method.

42 ENGINEERING↗

Transformer Health Monitoring Using Dissolved Gas Analysis

As integral components of any power plant, transformers supply the generated electricity to the grid. However, a transformer’s cellulose-based paper insulation and the mineral oil in which it is immersed break down over time under standard operating conditions—or more rapidly due to potential faults within the system. As the transformer’s mineral oil breaks down, gases are released that can be measured and monitored. This technical brief exhibits a collection of diagnostic and prognostic techniques that utilities can adopt in lieu of labor-intensive periodic preventive maintenance routines. Furthermore, prognostic models have been incorporated using the latest version of the Institute of Electrical and Electronics Engineers (IEEE) standard (IEEE, 2019) for dissolved gas analysis (DGA), thus expanding it to include estimation of the time to maintenance. Overall, four different methodologies are explained, each of which aids in determining a transformer’s state of health. These methodologies include the Chendong model, the IEEE thermal life consumption model (IEEE, 2012), a diagnostic model for DGA, and a prognostic model for DGA that uses an autoregressive integrated moving average (ARIMA) model. An additional improvement for estimating missing system parameters by using monitoring data (i.e., a tool for parameter estimation utilizing Powell’s method) is presented, enabling the IEEE thermal life consumption model to benefit not only the collaborating power plant, but also the power industry at large.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

This presentation starts with the details of IEEE 2800-2022 requirements of IBR for balanced and unbalanced faults. Then, it shows how to design a droop based GFM control to be IEEE 2800-2022 compliant. An performance evaluation is carried out to see if three OEM GFM inverters 2800-2022 compliant or not. And finally we show how IEEE 2800-2022 complaint and non-compliant GFM inverter will impact the transmission line protection elements, such as directional element and FID. Finally, recommendations are made if the GFM is not IEEE 2800-2022 compliant to disable the protection elements that rely on reliable and regulated negative sequence current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

A Benchmark Case for the Grid Survivability Analysis

Among current priorities of the power system analysis is the development of metrics and computational tools for the resilience analysis during catastrophic events. New methods and tools are required for such an analysis and they have to be validated prior application to real systems. However, benchmark problems are not readily available due to the analysis novelty. The current paper presents a case based on the IEEE 14-bus system for this purpose. The grid is simplified to a graph with nodes representing generators, loads, and buses. Power inputs are imported from real-time simulations of the IEEE 14-bus system. Outcomes of all possible combinations of failed elements are presented in terms of probabilities for the grid to survive, partially survive, or fail. Only the power grid's ability to withstand adverse events (survivability) is analyzed. The grid's recoverability, the other part of the resilience analysis, is not considered.

power system↗

A Medium-/Low-Voltage Joint State Estimator Through Linear Uncertainty Propagation

Traditionally, distribution system state estimations (DSSE) are challenged by the lack of measurements at both primary and secondary sides of the system. The widely available cable television (CATV) voltage sensors installed in low-voltage (LV) networks bring opportunities to achieve higher quality DSSE covering a broader area of the distribution network. This study proposes a medium-/low-voltage (MV/LV) joint distribution system state estimation approach using the untapped CATV measurements. It aims at addressing the need for system situational awareness at the grid edge while improving the estimation accuracy at both the primary and secondary sides compared to its disjointed counterpart. Linearized measurement functions and boundary condition uncertainty propagation rules are derived to ensure the computational efficiency and accuracy of the joint state estimator. Numerical experiments are conducted on an IEEE test feeder to demonstrate the efficacy of the proposed method and the value of CATV measurements.

joint state estimation↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

New Approaches to Low-Cost Scalable Doping of Interdigitated back Contact Silicon Solar Cells (Final Report)

The goal of this project was to develop novel approaches to patterning of dopants in the rear fingers of interdigitated back contact (IBC) Si solar cells to reduce the cost of manufacturing this high-efficiency-potential cell architecture. The work throughout this project can be divided into four categories: (a) development of dopant patterning technique using laser scribed Si contacts masks that are mechanically aligned with ~10 μm resolution to the underlying Si substrate; (b) measuring dopant spreading profiles in the isolation region between n- and p-type dopant fingers during plasma-enhanced chemical vapor deposition (PECVD) of doped hydrogenated amorphous silicon (a-Si:H) via shadow masks, and dopant desorption and re-adsorption during high-temperature annealing; (c) understanding the role of dopant compensation on the shunt resistance in contaminated isolation regions through analysis of defect-enhanced compensation; and (d) simulation and fabrication of passivated two-sided grid and back-contact solar cells to demonstrate the use of direct dopant patterning in cell fabrication. For the passivated two-sided grid solar cells, masked deposition was used to demonstrate an improvement in the blue response of the cell by creating a shallow front emitter. During development of the masked PECVD patterning process, we measured 3-D dopant profiles using secondary ion mass spectrometry. After deposition, in the masked region, the phosphorus dopant tail was >100 µm at concentrations >10 19 cm -3 while the boron dopant tail was shorter. During high-temperature crystallization of doped a-Si:H films to polycrystalline Si (poly-Si), phosphorus atoms spread by desorbing from the poly-Si surface and re-adsorbing onto intrinsic poly-Si on adjacent wafers that were separated by several millimeters. These contamination mechanisms resulted in a decrease in resistivity from ~10 5 Ω·cm for intrinsic poly-Si to ~10 -1 Ω·cm for contaminated poly-Si. Mitigation strategies for each contamination mechanism were developed to maintain a resistivity of ~10 5 Ω·cm between doped fingers. During fabrication of the 209 cells created during this project, it was found that despite contamination of the IBC gap through the abovementioned mechanisms, high shunt resistances and FF ~75% were still reached. Investigation into this led to the discovery of defect-enhanced compensation which exists within highly defective poly-Si when net doping concentrations reach the value of defect density (~10 18 cm -3 for many poly-Si films). Simulations guided us in the fabrication of IBCs and the cells fabricated were able to meet the year-end goals for BP 2 and 3 of 15% and 17% IBC cell efficiency, as well as the BP 4 goal of a 1% absolute increase in efficiency for PERC-like devices. However, the most efficient cell created during this project of 18.6% fell short of the 21% final project target. While the champion device fell short in V oc and J sc , many devices fabricated were able to reach the necessary goals of ~40 mA/cm 2 , ~700 mV, and ~75% FF required for a 21% device. The results generated from this project were disseminated through 11 conference presentations and proceedings. Presentations included oral talks at 2019 IEEE PVSC, 2019 MRS Fall Meeting, 2020 PVSEC-30 and 2021 IEEE PVSC, as well as poster presentations at 2020 IEEE PVSC and 2021 SiPV. The project resulted in 2 peer reviewed publications – one published in IEEE Journal of Photovoltaics and one in ACS Applied Energy Materials. The information gained in this project will aid in development of improved processes for fabrication of high-efficiency solar cells and other areas of the semiconductor device industry as well. The IBC cells will also pave the way for higher efficiency tandem devices. Through further manufacturing of high-efficiency solar cells, more of the world’s energy demands can be met through renewable sources, helping to stave off the worst effects that may come about from global climate change.

14 SOLAR ENERGY↗

Universal Utility Data Exchange (UUDEX): Information Exchange Models for Solar DER (Rev. 1)

This report describes how the Universal Utility Data Exchange (UUDEX) can encapsulate and exchange information about distributed energy resources (DER) within UUDEX-formatted JSON documents. It proposes to use the existing extensible markup language (XML) information exchange format described in IEEE Std 2030.5, IEEE Standard for Smart Energy Profile Application Protocol but not other information exchange provisions of IEEE 2030.5, rather, relying on equivalent mechanisms in UUDEX. This will allow adoption of the UUDEX exchanges with minimal changes to the structure of the information exchanged and will not require a modification to the UUDEX documentation if IEEE 2030.5 makes changes to the information models.

14 SOLAR ENERGY↗

Universal Utility Data Exchange (UUDEX): Information Exchange Models for Solar DER

This report describes how the Universal Utility Data Exchange (UUDEX) can encapsulate and exchange information about distributed energy resources (DER) within UUDEX-formatted JSON documents. It proposes to use the existing extensible markup language (XML) information exchange format described in IEEE Std 2030.5, IEEE Standard for Smart Energy Profile Application Protocol but not other information exchange provisions of IEEE 2030.5, rather, relying on equivalent mechanisms in UUDEX. This will allow adoption of the UUDEX exchanges with minimal changes to the structure of the information exchanged and will not require a modification to the UUDEX documentation if IEEE 2030.5 makes changes to the information models.

42 ENGINEERING↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

ECAR-7517 Rev 1 MARVEL I&C Failure Modes and Effects Analysis

The purpose of this document is to perform a single-failure analysis through the use of a Failure Modes and Effects Analysis (FMEA) for the Safety Related components of the MARVEL Instrumentation and Control (I&C) System. The intent is that this document will meet the requirements for a single-failure analysis described in IEEE-379, “IEEE Standard for Application of the Single-Failure Criterion to Nuclear Power Generating Station Safety Systems”, to verify that this design does indeed meet the single failure criterion. Principles of IEEE-352, “IEEE Guide for General Principles of Reliability Analysis of Nuclear Power Generating Station Safety Systems” are followed to ensure the analysis is consistent with industry standards.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗